International Standards
- The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
- Contact your OMRON representative for further details and applicable conditions for these standards.
Controller Link Units
Unit clas- sifica- tion | Product name | Specifications | No. of unit numbers allocated | Current consumption (A) | Model | Stand- ards | ||||
---|---|---|---|---|---|---|---|---|---|---|
Communi- cations cable | Communi- cations type | Duplex support | Max. Units mountable per CPU Unit | 5 V DC | 24 V DC | |||||
CJ1 CPU Bus Unit | Controller Link Unit | Wired shielded twisted-pair cable * | Data links and message service | No | 8 | 1 | 0.35 | --- | CJ1W-CLK23 | UC1, N, L, CE |
Note: This unit cannot be used with the Machine Automation Controller NJ-series.
* Use the following special cable for shielded, twisted-pair cable.
• ESVC0.5×2C-13262 (Bando Electric Wire: Japanese Company)
• ESNC0.5×2C-99-087B (JMACS Japan Co., Ltd.: Japanese Company)
• ESPC 1P×0.5mm2 (Nagaoka Electric Wire Co.,Ltd.: Japanese Company)
• Li2Y-FCY2×0.56qmm (Kromberg & Schubert, Komtec Department: German Company)
• 1×2×AWG-20PE+Tr.CUSN+PVC (Draka Cables Industrial: Spanish Company)
• #9207 (Belden: US Company)
* Use the following special cable for shielded, twisted-pair cable.
• ESVC0.5×2C-13262 (Bando Electric Wire: Japanese Company)
• ESNC0.5×2C-99-087B (JMACS Japan Co., Ltd.: Japanese Company)
• ESPC 1P×0.5mm2 (Nagaoka Electric Wire Co.,Ltd.: Japanese Company)
• Li2Y-FCY2×0.56qmm (Kromberg & Schubert, Komtec Department: German Company)
• 1×2×AWG-20PE+Tr.CUSN+PVC (Draka Cables Industrial: Spanish Company)
• #9207 (Belden: US Company)
Accessories
There is no accessory for the CJ series Controller Link Unit.
Controller Link Support Boards
Product name | Specifications | Accessories | Model | Standards | |
---|---|---|---|---|---|
Communications cable | Communications type | ||||
Controller Link Support Board for PCI Bus | Wired shielded twisted-pair cable | Data links and message service | CD-ROM x 1 * INSTALLATION GUIDE (W467) x 1 Communications connector x 1 | 3G8F7-CLK23-E | CE |
* The CD-ROM contains the following software.
• Controller Link (PCI) Driver
• FinsGateway Version 2003 (PCI-CLK Edition)
• FinsGateway Version 3 (PCI-CLK Edition)
• Setup Diagnostic Utility
• C Library
• Controller Link (PCI) Driver
• FinsGateway Version 2003 (PCI-CLK Edition)
• FinsGateway Version 3 (PCI-CLK Edition)
• Setup Diagnostic Utility
• C Library
Repeater Units
Name | Specifications | Model | Standards |
---|---|---|---|
Controller Link Repeater Unit | Wire-to-Wire Model | CS1W-RPT01 | UC1, CE |
Wire-to-Optical (H-PCF) Model *1 | CS1W-RPT02 | ||
Wire-to-Optical (GI) Model *2 | CS1W-RPT03 |
Using Repeater Units enables T-branches and long-distance wiring for Wired Controller Link networks, 62-node configurations, and converting part of the network to optical cable.
*1. When using wire-to-optical (H-PCF) cable, use a H-PCF cable (for both Controller Link and SYSMAC LINK) or a H-PCF
optical fiber cable with connector.
*2. When using wire-to-optical (GI) cable, use a GI optical cable (for Controller Link).
*1. When using wire-to-optical (H-PCF) cable, use a H-PCF cable (for both Controller Link and SYSMAC LINK) or a H-PCF
optical fiber cable with connector.
*2. When using wire-to-optical (GI) cable, use a GI optical cable (for Controller Link).
Relay Terminal Block
Name | Specifications | Model | Standards |
---|---|---|---|
Relay Terminal Block for Wired Controller Link Units | Used for Wired Controller Link Units (set of 5) | CJ1W-TB101 | --- |
Controller Link Units can be replaced without stopping the communications of the entire network if a Relay Terminal Block is installed in advance on the Unit in a Wired Controller Link network. Relay Terminal Blocks cannot be used on Controller Link Support Boards.
H-PCF Cables and Optical Connectors
Name | Application/construction | Specifications | Model | Standards | |||
---|---|---|---|---|---|---|---|
Optical Fiber Cables | Controller Link, SYSMAC LINK, SYSBUS | 1. Optical fiber single-core cord 2. Tension member (plastic-sheathed wire) 3. Filler (plastic) 4. Filler surrounding signal wires (plastic, yarn, or fiber) 5. Holding tape (plastic) 6. Heat-resistant PV sheath | Two-core optical cable with tension member | Black 10 m | S3200-HCCB101 | --- | |
Black 50 m | S3200-HCCB501 | ||||||
Black 100 m | S3200-HCCB102 | ||||||
Black 500 m | S3200-HCCB502 | ||||||
Black 1000 m | S3200-HCCB103 | ||||||
Orange 10 m | S3200-HCCO101 | ||||||
Orange 50 m | S3200-HCCO501 | ||||||
Orange 100 m | S3200-HCCO102 | ||||||
Orange 500 m | S3200-HCCO502 | ||||||
Orange 1000 m | S3200-HCCO103 | ||||||
Optical Connectors (Crimp-cut) | CS1W-RPT02 | Half lock | S3200-COCF2571 | ||||
Full lock | S3200-COCF2071 |
H-PCF Optical Fiber Cables with Connectors (Black Composite Cables with Two-Optical Lines and Two Power Supply Lines)
Application | Appearance | Model | Standards |
---|---|---|---|
Controller Link, SYSMAC LINK | S3200-CN[][][]-20-20 | --- | |
S3200-CN[][][]-20-25 | |||
S3200-CN[][][]-25-25 |
Optical connectors for H-PCF Optical Cables with Connectors are adhesive polished.
Cable Length
The following cable lengths are available: 2 m, 5 m, 15 m, 20 m. For lengths of 21 m or more, contact your OMRON sales representative.
Model Numbers
Optical Connector Assembly Tool
Name | Applicable Unit | Model | Manufacturer | Standards |
---|---|---|---|---|
Optical Fiber Assembly Tool * | This tool is used on site for mounting crimp-cut connectors and hard plastic-clad silica optical fiber for optical transmission systems of SYSMAC C-series SYSBUS, SYSMAC LINK, and Controller Link. | CAK-0057 | Sumitomo Electric Industries, Ltd. | --- |
* There is a risk of quality problems when using cables assembled by typical users, so we recommend purchasing
cables with preattached connectors or having a qualified technician assemble the cables.
cables with preattached connectors or having a qualified technician assemble the cables.