CJ-series Serial Communications Units CJ1W-SCU

International Standards

  • The standards are abbreviated as follows: U: UL, U1: UL(Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
  • Contact your OMRON representative for further details and applicable conditions for these standards.
Unit
type
Product
name
SpecificationsNo. of
unit
numbers
allocated
Current
consumption
(A)
ModelStand-
ards
Communications
Interface
Communications
functions
5V24V
CJ1
CPU
Bus
Units
Serial
Communi-
cations Units
(High-speed
type)
2 RS-232C portsThe following functions
can be selected for each
port with an CJ-system:
Protocol macro
Host Link
NT Links (1:N mode)
Serial Gateway
No-protocol *3
Modbus-RTU Slave

The following functions
can be selected for each
port with an NJ-system:
Protocol macro
Serial Gateway
No-protocol
Modbus-RTU Slave
10.28
*1
-CJ1W-SCU22 *2UC1, N,
L, CE
2 RS-422A/485 ports0.4-CJ1W-SCU32 *2
1 RS-232C port and
1 RS-422A/485 port
0.36
*1
-CJ1W-SCU42 *2
CJ1
CPU
Bus
Units
Serial
Communi-
cations Units
2 RS-232C portsThe following functions
can be selected for each
port:
Protocol macro *4
Host Link
NT Links (1:N mode)
Serial Gateway *5
No-protocol *6
Modbus-RTU Slave *7
10.28
*1
-CJ1W-SCU21-V1 *8UC1, N,
L, CE
2 RS-422A/485 ports0.38-CJ1W-SCU31-V1 *8
1 RS-232C port and
1 RS-422A/485 port
0.38
*1
-CJ1W-SCU41-V1 *8
*1. When an NT-AL001 RS-232C/RS-422A Conversion Unit is used, this value increases by 0.15 A/Unit. 
*2. Sinple Backup Function and Interrupt notification function cannot be used with an NJ-system. 
*3. A Serial Communications Unit with unit version 2.1 or later, a CPU Unit with unit version 1.03 orlater, and Sysmac 
       Studio version 1.04 or higher are required to use the SerialRcvNoClear instruction. 
*4. You can activate Protocol macro trace function when the CPU Unit is set to the RUN/MONITOR mode. (MONITOR 
       mode is not available with the NJ-series CPU Units.) 
*5. The Serial Gateway function is enabled only for Serial Communications Units of unit version 1.2 and later. 
*6. The no-protocol function is enabled only for Serial Communications Units of unit version 1.2 and later (and a CPU Unit 
       of unit version 3.0 or later is also required). 
*7. The Modbus-RTU Slave function is enabled only for Serial Communications Units of unit version 1.3 and later. 
*8. This unit cannot be used, with the Machine Automation Controller NJ-series.

Accessories

ModelAccessoriesSpecifications
CJ1W-SCU222 Serial Port (RS-232C) ConnectorConnector set for serial port connection (D-SUB 9-pin male connector)
CJ1W-SCU322 Serial Port (RS-422A/485) ConnectorTerminal Block Connector (FMC1.5/5-STF-3.5AU by Phoenix Contact)
CJ1W-SCU421 Serial Port (RS-232C) ConnectorConnector set for serial port connection (D-SUB 9-pin male connector)
1 Serial Port (RS-422A/485) ConnectorTerminal Block Connector (FMC1.5/5-STF-3.5AU by Phoenix Contact)
CJ1W-SCU21-V1
CJ1W-SCU31-V1
CJ1W-SCU41-V1
2 Serial Port (RS-232C) ConnectorConnector set for serial port connection (D-SUB 9-pin male connector)