Since 2001, CJ1M-series PLCs are in control of a wide variety of applications worldwide. The accumulated experience and advancements in technology now result in CJ2M; fully compatible, yet fully new.
International Standards
- The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
- Contact your OMRON representative for further details and applicable conditions for these standards.
CJ2M CPU Units (Built-in EtherNet/IP)
Product name | Specifications | Current consump- tion (A) | Model | Stand- ards | ||||||
---|---|---|---|---|---|---|---|---|---|---|
I/O capacity/ Mountable Units (Expansion Racks) | Pro- gram ca- pacity | Data memory capacity | LD instruc- tion exe- cution time | EtherNet/ IP function | Option board slot | 5 V | 24 V | |||
CJ2M (Built-in EtherNet/ IP) CPU Units | 2,560 points/ 40 Units (3 Expansion Racks max.) | 60K steps | 160K words (DM: 32K words, EM: 32K words × 4 banks) | 0.04 μs | YES | YES | 0.7 * | - | CJ2M-CPU35 | UC1, N, L, CE |
30K steps | CJ2M-CPU34 | |||||||||
20K steps | 64K words (DM: 32K words, EM: 32K words × 1 bank) | CJ2M-CPU33 | ||||||||
10K steps | CJ2M-CPU32 | |||||||||
5K steps | CJ2M-CPU31 |
* Add 0.005A, 0.030A and 0.075A when using Serial Communications Option Boards (CP1W-CIF01/11/12), respectively.
Add 0.15A/Unit when using NT-AL001 RS-232C/RS-422A Adapters.
Add 0.04A/Unit when using CJ1W-CIF11 RS-422A Adapters.
Add 0.20A/Unit when using NV3W-M[]20L(-V1) Programmable Terminals.
Add 0.15A/Unit when using NT-AL001 RS-232C/RS-422A Adapters.
Add 0.04A/Unit when using CJ1W-CIF11 RS-422A Adapters.
Add 0.20A/Unit when using NV3W-M[]20L(-V1) Programmable Terminals.
CJ2M CPU Units
Product name | Specifications | Current consump- tion (A) | Model | Stand- ards | ||||||
---|---|---|---|---|---|---|---|---|---|---|
I/O capacity/ Mountable Units (Expansion Racks) | Pro- gram ca- pacity | Data memory capacity | LD instruc- tion exe- cution time | EtherNet/ IP function | Option board slot | 5 V | 24 V | |||
CJ2M CPU Units | 2,560 points/ 40 Units (3 Expansion Racks max.) | 60K steps | 160K words (DM: 32K words, EM: 32K words × 4 banks) | 0.04 μs | - | - | 0.5 * | - | CJ2M-CPU15 | UC1, N, L, CE |
30K steps | CJ2M-CPU14 | |||||||||
20K steps | 64K words (DM: 32K words, EM: 32K words × 1 bank) | CJ2M-CPU13 | ||||||||
10K steps | CJ2M-CPU12 | |||||||||
5K steps | CJ2M-CPU11 |
* Add 0.15A/Unit when using NT-AL001 RS-232C/RS-422A Adapters.
Add 0.04A/Unit when using CJ1W-CIF11 RS-422A Adapters.
Add 0.20A/Unit when using NV3W-M[]20L(-V1) Programmable Terminals.
Add 0.04A/Unit when using CJ1W-CIF11 RS-422A Adapters.
Add 0.20A/Unit when using NV3W-M[]20L(-V1) Programmable Terminals.
Serial Communications Option Boards (Only CJ2M-CPU3[])
The serial communications port can be equipped by installing the serial communications option board to the option board slot in front of CPU unit.
Product name | Specifications | Serial communications mode | Current consump- tion (A) | Model | Stand- ards | |
---|---|---|---|---|---|---|
5 V | 24 V | |||||
RS-232C Option Board | One RS-232C port Connector: D-Sub, 9 pin, female Maximum transmission distance: 15m One RS-232C connector (D-Sub, 9 pin, male) is included. | Host Link, 1:N NT Link, Noprotocol, Serial PLC Link Slave, Serial PLC Link Master, Serial Gateway converted to CompoWay/F, and Tool Bus * | 0.005 | --- | CP1W-CIF01 | UC1, N, L, CE |
RS-422A/485 Option Board | One RS-422A/485 port Terminal block: using ferrules Maximum transmission distance: 50m | 0.03 | --- | CP1W-CIF11 | ||
RS-422A/485 Isolated-type Option Board | One RS-422A/485 port (Isolated) Terminal block: using ferrules Maximum transmission distance: 500m | 0.075 | --- | CP1W-CIF12 |
Note: It is not possible to use a CP-series Ethernet Option Board (CP1W-CIF41), LCD Option Board (CP1W-DAM01) with
a CJ2M CPU Unit.
* The following modes cannot be used: 1:1 NT Link, Serial Gateway converted to Host Link FINS, 1:1 Link Master, and
1:1 Link Slave.
a CJ2M CPU Unit.
* The following modes cannot be used: 1:1 NT Link, Serial Gateway converted to Host Link FINS, 1:1 Link Master, and
1:1 Link Slave.
Pulse I/O Modules (Only CJ2M CPU Unit with Unit Version 2.0 or Later)
Optional Pulse I/O Modules can be mounted to enable pulse I/O. Up to two Pulse I/O Modules can be mounted to the left side of a CJ2M CPU Unit.
Product name | Specifications | Current consumption (A) | Model | Stand- ards | |
---|---|---|---|---|---|
5 V | 24 V | ||||
Pulse I/O Modules | Sinking outputs, MIL connector 10 inputs (including four interrupt/quickresponse inputs and two high-speed counter inputs) 6 outputs (including two pulse outputs and two PWM outputs) | 0.08 | --- | CJ2M-MD211 | UC1, N, L, CE |
Sourcing outputs, MIL connector CE 10 inputs (including four interrupt/quickresponse inputs and two high-speed counter inputs) 6 outputs (including two pulse outputs and two PWM outputs) | 0.08 | --- | CJ2M-MD212 |
Note: Connectors are not provided with Pulse I/O Modules. Purchase the following Connector, an OMRON Cable with
Connectors for Connector Terminal Block Conversion Units, or an OMRON Cable with Connectors for Servo Relay
Units.
Connectors for Connector Terminal Block Conversion Units, or an OMRON Cable with Connectors for Servo Relay
Units.
Connecting to Pulse I/O Modules
Product name | Specifications | Model | Stand- ards | ||
---|---|---|---|---|---|
Applicable Connector | MIL Flat Cable Connectors (Pressure-fitted Connectors) | XG4M-4030-T | --- | ||
Connector- Terminal Block Conversion Units | Phillips screw (M3 screw terminals, 40-terminals) | XW2R-J40G-T | --- | ||
Slotted screw (M3 European type, 40-terminals) | XW2R-E40G-T | ||||
Push-in spring (Clamp 40-terminals) | XW2R-P40G-T | ||||
Cable for Connector- Terminal Block Conversion Unit | Cable length: 0.25 m | XW2Z-C25K | |||
Cable length: 0.5 m | XW2Z-C50K | ||||
Cable length: 1 m | XW2Z-100K | ||||
Cable length: 1.5 m | XW2Z-150K | ||||
Cable length: 2 m | XW2Z-200K | ||||
Cable length: 3 m | XW2Z-300K | ||||
Cable length: 5 m | XW2Z-500K | ||||
Servo Relay Units | Servo Relay Unit for 1 axis | XW2B-20J6-8A | --- | ||
Servo Relay Unit for 2 axes | XW2B-40J6-9A | ||||
Cables for Servo Relay Units | OMNUC G5/G Series | Cable for Pulse I/O Modules | Cable length: 0.5 m | XW2Z-050J-A33 | --- |
Cable length: 1 m | XW2Z-100J-A33 | ||||
Servo Driver Connecting Cables | Cable length: 1 m | XW2Z-100J-B31 | |||
Cable length: 2 m | XW2Z-200J-B31 | ||||
SMARTSTEP2 | Cable for Pulse I/O Modules | Cable length: 0.5 m | XW2Z-050J-A33 | ||
Cable length: 1 m | XW2Z-100J-A33 | ||||
Servo Driver Connecting Cables | Cable length: 1 m | XW2Z-100J-B32 | |||
Cable length: 2 m | XW2Z-200J-B32 | ||||
SMARTSTEP Junior | Cable for Pulse I/O Modules | Cable length: 1 m | XW2Z-100J-A26 | ||
Servo Driver Connecting Cables | Cable length: 1 m | XW2Z-100J-B17 | |||
Cable length: 2 m | XW2Z-200J-B17 | ||||
SMARTSTEP A Series | Cable for Pulse I/O Modules | Cable length: 1 m | XW2Z-100J-A26 | ||
Servo Driver Connecting Cables | Cable length: 1 m | XW2Z-100J-B5 | |||
Cable length: 2 m | XW2Z-200J-B5 |
Accessories
The following accessories come with CPU Unit:
Item | Specification |
---|---|
Battery | CJ1W-BAT01 |
End Cover | CJ1W-TER01 (necessary to be mounted at the right end of CPU Rack) |
End Plate | PFP-M (2 pcs) |
Serial Port (RS-232C) Connector * | Connector set for serial port connection (D-SUB 9-pin male connector) |
* Connector is provided with CJ2M-CPU1[].