International Standards
- The standards are availabled as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
- Contact your OMRON representative for further details and applicable conditions for these standards.
Programmable Terminals
Product name | Specifications | Model | Standards | |||
---|---|---|---|---|---|---|
Effective display area | Number of dots | Ethernet | Case color | |||
NS5-V2 *1 | 5.7-inch *2 TFT color LED backlight | 320 × 240 dots | No | Ivory | NS5-SQ10-V2 | UC1, CE, N, L, UL Type4 |
Black | NS5-SQ10B-V2 | |||||
Yes | Ivory | NS5-SQ11-V2 | ||||
Black | NS5-SQ11B-V2 | |||||
5.7-inch *2 High-luminance TFT color LED backlight | No | Ivory | NS5-TQ10-V2 | |||
Black | NS5-TQ10B-V2 | |||||
Yes | Ivory | NS5-TQ11-V2 | ||||
Black | NS5-TQ11B-V2 | |||||
NS8-V2 | 8.4-inch *2 TFT LED backlight | 640 × 480 dots | No | Ivory | NS8-TV00-V2 | UC1, CE, N, L |
Black | NS8-TV00B-V2 | |||||
Yes | Ivory | NS8-TV01-V2 | ||||
Black | NS8-TV01B-V2 | |||||
NS10-V2 | 10.4-inch *2 TFT LED backlight | 640 × 480 dots | No | Ivory | NS10-TV00-V2 | UC1, CE, N, L, UL Type4 |
Black | NS10-TV00B-V2 | |||||
Yes | Ivory | NS10-TV01-V2 | ||||
Black | NS10-TV01B-V2 | |||||
NS12-V2 | 12.1-inch *2 TFT LED backlight | 800 × 600 dots | No | Ivory | NS12-TS00-V2 | |
Black | NS12-TS00B-V2 | |||||
Yes | Ivory | NS12-TS01-V2 | ||||
Black | NS12-TS01B-V2 | |||||
NS15-V2 | 15-inch TFT | 1,024 × 768 dots | Yes | Silver | NS15-TX01S-V2 | |
Black | NS15-TX01B-V2 | |||||
NSH5-V2 *1 Hand-held | 5.7-inch TFT | 320 × 240 dots | No | Black (Emergency stop button: Red) | NSH5-SQR10B-V2 | UC, CE |
Black (Stop button: Gray) | NSH5-SQG10B-V2 |
*1. As of July 2008, the image memory has been increased to 60 MB.
*2. Lot No. 15Z0 or later of NS5 color-type models, Lot No. 28X1 or later of NS8 models, Lot No. 11Y1 or later of NS10
models, Lot No. 14Z1 or later of NS12 models, Lot No. 31114K or later of NS15 models.
*2. Lot No. 15Z0 or later of NS5 color-type models, Lot No. 28X1 or later of NS8 models, Lot No. 11Y1 or later of NS10
models, Lot No. 14Z1 or later of NS12 models, Lot No. 31114K or later of NS15 models.
NS-Runtime
Product name | Specifications | Media | Model | Standards | |
---|---|---|---|---|---|
NS-Runtime | NS-Runtime Installer, PDF manual, hardware key * | 1 license | CD | NS-NSRCL1 | --- |
3 licenses | NS-NSRCL3 | ||||
10 licenses | NS-NSRCL10 |
Note: A hardware key (USB dongle) is required for NS-Runtime operation.
System Requirements
Item | Specifications |
---|---|
OS | Windows XP (Service Pack 3 or higher), Vista, 7 or 8 (Support 64-bit version for Windows 7 and Windows 8.) |
CPU | Celeron, 1.3 GHz or higher (Recommended) |
Memory size | HDD: 50 MB min., RAM: 512 MB min. (Windows 7: 1 GB min.). 50 MB is required for the Runtime alone. (An additional 280 MB is required if CX-Server is not already installed.) |
Software
How to Select Required Support Software for Your Controller
The required Support Software depends on the Controller to connect. Please check the following table when purchasing the Support Software.
Item | Omron PLC System | Omron Machine Automation Controller System |
---|---|---|
Controller | CS, CJ, CP, and other series | NJ-series and NX-series |
Programmable Terminals | NS-series | NS-series with an Ethernet port |
Software | FA Integrated Tool Package CX-One | Automation Software Sysmac Studio |
FA Integrated Tool Package CX-One
Product name | Specifications | Model | Stand- ards | ||
---|---|---|---|---|---|
Number of licenses | Media | ||||
FA Integrated Tool Package CX-One Ver.4.[] | The CX-One is a comprehensive software package that integrates Support Software for OMRON PLCs and components. CX-One runs on the following OS. Windows XP (Service Pack 3 or higher, 32-bit version)/Windows Vista (32-bit/64-bit version)/ Windows 7 (32-bit/64-bit version)/Windows 8 (32-bit/64-bit version)/Windows 8.1 (32-bit/ 64-bit version) CX-One Version 4.[] includes CX-Designer Ver.3.[]. For details, refer to the CX-One catalog (Cat. No. R134) | license * | DVD | CXONE-AL01D-V4 | --- |
* Multi licenses are available for the CX-One (3, 10, 30, or 50 licenses).
Automation Software Sysmac Studio
Please purchase a DVD and required number of licenses the first time you purchase the Sysmac Studio. DVDs and licenses are available individually. Each model of licenses does not include any DVD.
Product name | Specifications | Model | Stand- ards | ||
---|---|---|---|---|---|
Number of licenses | Media | ||||
Sysmac Studio Standard Edition Ver.1.[] | The Sysmac Studio provides an integrated development environment to set up, program, debug, and maintain NJ/NX Series Controllers and other Machine Automation Controllers, as well as EtherCAT slaves. Sysmac Studio runs on the following OS. Windows XP (Service Pack 3 or higher, 32-bit version)/ Windows Vista (32-bit version)/Windows 7 (32-bit/64-bit version)/Windows 8 (32-bit/64-bit version)/Windows 8.1 (32-bit/64-bit version)/Windows 10 (32-bit/64-bit version) The Sysmac Studio Standard Edition DVD includes Support Software to set up EtherNet/IP Units, DeviceNet slaves, Serial Communications Units, and Support Software for creating screens on HMIs (CX- Designer). For details, refer to the Sysmac Integrated Catalogue (P072). | - (Media only) | DVD | SYSMAC-SE200D | --- |
1 license * | --- | SYSMAC-SE201L | --- |
Note: To connect the NJ5 Controller, NS system version 8.5 or higher is required. CX-Designer version 3.3 or higher is
also required.
To connect the NJ1/NJ3 Controller, NS system version 8.61 or higher is required. CX-Designer version 3.4 or higher
is also required.
To connect the NX7 Controller, NS system version 8.9 or higher is required. CX-Designer version 3.64 or higher is
also required.
* Multi licenses are available for the Sysmac Studio (3, 10, 30, or 50 licenses).
also required.
To connect the NJ1/NJ3 Controller, NS system version 8.61 or higher is required. CX-Designer version 3.4 or higher
is also required.
To connect the NX7 Controller, NS system version 8.9 or higher is required. CX-Designer version 3.64 or higher is
also required.
* Multi licenses are available for the Sysmac Studio (3, 10, 30, or 50 licenses).
Cable
Product name | Specifications | Model | Stand- ards | ||
---|---|---|---|---|---|
Cable *1 | Screen transfer cable for DOS/V (CX-Designer ↔ PT) | Length: 2 m | XW2Z-S002 | --- | |
USB-Serial Conversion Cable | Length: 0.5 m | CS1W-CIF31 | N | ||
USB relay cable | Length: 1 m | NS-USBEXT-1M | --- | ||
NSH5 Cables | RS-422A cable (loose wires + D-Sub 9-pin) | Length: 10 m | NSH5-422CW-10M | ||
RS-232C cable (loose wires + D-Sub 9-pin) | Length: 3 m | NSH5-232CW-3M | |||
RS-232C cable (loose wires + D-Sub 9-pin) | Length: 10 m | NSH5-232CW-10M | |||
UL-compliant NSH5 Cable | RS-422A cable (loose wires) | Length: 10 m | NSH5-422UL-10M | CU | |
RS-232C cable (loose wires + relay cable) | Length: 3 m | NSH5-232UL-3M | |||
RS-232C cable (loose wires + relay cable) | Length: 10 m | NSH5-232UL-10M | |||
PT-to-PLC Connecting Cable *2 | PT connection: 9 pins PLC connection: 9 pins | Length: 2 m | XW2Z-200T | --- | |
Length: 5 m | XW2Z-500T | ||||
PT connection: 9 pins PLC peripheral port | Length: 2 m | XW2Z-200T-2 | |||
Length: 5 m | XW2Z-500T-2 | ||||
NSH5 Removable Box Cable | RS-232C Cable (connectors) | Length: 3 m | NSH5-232CN-3M | ||
Length: 10 m | NSH5-232CN-10M | ||||
NSH5 Removable Box | --- | NSH5-AL001 | |||
NSH5 Wall-mounting Bracket | --- | NSH5-ATT02 | |||
NSH5 Visor | --- | NSH5-ATT01 |
*1. Use a standard USB Type A male to Type B type male Cable to connect the NS series PT to a personal computer
(CX-Designer).
Use a standard USB cable to connect the NS series PT to a PictBridge-compatible printer. USB cable type depends
on the printer.
*2. To connect the NS series PT to NJ series Controller, using a commercially available 10/100-BASE-TX twisted-pair
cable.
For detail, refer to the NS series SETUP MANUAL (Cat. No.V083).
(CX-Designer).
Use a standard USB cable to connect the NS series PT to a PictBridge-compatible printer. USB cable type depends
on the printer.
*2. To connect the NS series PT to NJ series Controller, using a commercially available 10/100-BASE-TX twisted-pair
cable.
For detail, refer to the NS series SETUP MANUAL (Cat. No.V083).
Options
Product name | Specifications | Model | Stand- ards | ||
---|---|---|---|---|---|
Video Input Unit | Inputs: 4 channels Signal type: NTSC/PAL | NS-CA001 | UC1, CE | ||
Input channels: 2 video channels and 1 RGB channel *1 Signal type: NTSC/PAL | NS-CA002 | ||||
Controller Link Interface Unit | For Controller Link Communications | NS-CLK21 | UC1, CE | ||
RS-422A Adapter | Transmission distance: 500 m total length Note: Use this model when connecting PT models without a V[] suffix. Note: PT models with the V[] suffix can also be connected. | NS-AL002 | --- | ||
Transmission distance: 50 m total length Note: Only PT models with a suffix of V[] are connectable. Use the NS-AL002 to connect models without a V[] suffix. | CJ1W-CIF11 | UC1, N, L, CE | |||
Sheet/ Cover *2 | Anti-reflection Sheets (5 surface sheets) | NS15 | NS15-KBA04 | --- | |
NS12/10 | NS12-KBA04 | ||||
NS8 | NS7-KBA04 | ||||
NS5 | NT30-KBA04 | ||||
Protective Covers (5 pack) (anti-reflection coating) | NS12/10 | NS12-KBA05 | |||
NS8 | NS7-KBA05 | ||||
NS5 | NT31C-KBA05 | ||||
Protective Covers (1 cover included) (Transparent) | NS15 | NS15-KBA05N | |||
Protective Covers (5 covers included) (Transparent) | NS12/10 | NS12-KBA05N | |||
NS8 | NS7-KBA05N | ||||
NS5 | NT31C-KBA05N | ||||
Attachment | NT625C/631/631C Series to NS12/10 Series | NS12-ATT01 | |||
NT625C/631/631C Series to NS12/NS10 Series (Black) | NS12-ATT01B | ||||
NT610C Series to NS12/10 Series | NS12-ATT02 | ||||
NT620S/620C/600S Series to NS8 Series | NS8-ATT01 | ||||
NT600M/600G/610G/612G Series to NS8 Series | NS8-ATT02 | ||||
Memory Card | 128 MB | HMC-EF183 | |||
256 MB | HMC-EF283 | ||||
512 MB | HMC-EF583 | ||||
Memory Card Adapter | --- | HMC-AP001 | CE | ||
Replacement Battery | Battery life: 5 years (at 25°C) | CJ1W-BAT01 | --- | ||
Bar Code Reader | CCD handheld bar code reader (RS-232C interface) | V520-RH21-6 |
*1. One screen cannot display two video inputs simultaneously.
*2. A Chemical-resistant Cover (NT30-KBA01) is available only for the NS5.
*2. A Chemical-resistant Cover (NT30-KBA01) is available only for the NS5.
CX ONE OMRON
BalasHapusCX ONE OMRON
CLICK SKIP AD
CX ONE OMRON
BalasHapusCX ONE OMRON
CLICK SKIP AD