Kontak Kami

KONTAK KAMI : Telpon : 02126071413 Hp/WhatsApp : 081212269831 Perwakilan Jakarta : Gedung LTC Glodok Lantai 1 Blok C30 No.31 Jl.Hayam Wuruk No.127 Jakarta , Indonesia

Selasa, 24 Mei 2016

NT11 / NT21

NT11 / NT21 Features 1 NT11_NT21_Feature
Please click image to enlarge (open in a new window)

NT11

ProductSpecificationModel
Programmable
Terminal*
Host link direct connection,
NT link method
Ten-key type (frame color: beige)NT11-SF121-EV1
Ten-key type (frame color: black)NT11-SF121B-EV1
Support SoftwareCD-ROM (for Windows 95, 98,
Me, XP, NT, 2000)
NT-ZJCAT1-EV4
Function key sheet10 sheets for replacement for beigeNT11-CKF01
10 sheets for replacement for blackNT11-CKF01B
* The PT body incorporated the communication interface, screen memory, and a flash ROM that downloads the system 
   program. 
* Connecting cables with the PLC and NTST are the same as those for the NT21.

NT21

ProductSpecificationModel number
NT21
Programmable
Terminal
Monochrome STNFrame color: beigeNT21-ST121-E
Frame color: blackNT21-ST121B-E
Support ToolWindows 95, 98, Me, NT, or 2000CD-ROMNT-ZJCAT1-EV4
CablesFor screen transferXW2Z-S002
For
PLC
connection
PT: 9-pin
PLC: 9-pin
Cable length: 2 mXW2Z-200T
Cable length: 5 mXW2Z-500T
PT: 9-pin
PLC: 25-pin
Cable length: 2 mXW2Z-200S
Cable length: 5 mXW2Z-500S
PT: 9-pin
PLC: Mini-peripheral
Cable length: 2 mXW2Z-200T-2
Cable length: 5 mXW2Z-500T-2
OptionsReflection Protective SheetsDisplay area only (5 sheets)NT20M-KBA04
Chemical-resistive CoverSilicon coverNT20S-KBA01
BatteryFor alarm lists/historiesC500-BAT08
Memory UnitFor screen and system
data transfer
NT-MF161
RS-232C/422A AdapterNS-AL002
Connector KitXM2S-0911-S003

NT11

General Specifications

ItemSpecification
Power supply voltage24 VDC
allowable power
supply voltage range
20.4 to 27.6 VDC (24 VDC-15%, +15%)
Power consumption10 W max.
Noise resistanceConforms to IEC61000-4-4, 2K (power lines)
Vibration resistance10 to 57 Hz with 0.075 mm amplitude and 57 to 150 Hz with
9.8 m/s2 acceleration for 30 min in each of X, Y, and Z directions
Shock resistance147 m/s2 3 times in each of X, Y, and Z directions
ambient operating
temperature
0 to +50°C
Ambient operating
humidity
35 to 85% RH (with no condensation)
Operating
environment
No corrosive gasses.
Storage temperature-20 to +70°C (with no freezing)
Enclosure ratingsFront panel: Equivalent to IP65, NEMA4
Weight1.0 kg max.

Display/Panel Specifications

Note: In order to improve the performance of displays, liquid crystal devices may be changed without notice.
ItemSpecification
Display screenDot matrix of STN liquid
crystal display panel
Number of dots: 160 x 64
Effective display area:
100 x 40 mm
Life expectancy: 50,000 hours
minimum
View angle (left/right direction):
±20°
Backlight
LED
Life expectancy: 50,000 hours
minimum
Automatic turn-off: can be set
to turn off in 10 minutes or
1 hour, or to remain on.
IndicatorsPOWER indicator (Green LDE): Lit while power is being supplied.
RUN indicator (Green LED): Lit during operation
Switch22 switches
Life expectancy: 1 million operations minimum

Display Capacity

Note: In order to improve the performance of displays, liquid crystal devices may be changed without notice.
ItemSpecification
Display charactersNormal characters (8 x 16 dots): Alphanumerics and symbols
Marks (8 x 16 dots): User-defined, 64 max.
Number of characters displayedNormal-size: 20 horizontally x 4 lines vertically max.
Eniargement functionDouble width
Display
elements
Characterstring
displays
8 positions per screen
Numeral displays8 positions per screen
Graph displays4 positions per screen
Numeral settings8 positions per screen
Screen
attributes
Display historyOrder of frequency, 256 screens
Password screenEnsures security: screens for which this attribute is set can only be displayed if the correct password is input.
Menu screenFour items per screen
Screen typesNormal screen: Displays screen registered as normal.
Max. number of registered screens250
Screen registration methodTransfer screen data created using an IBM PC/AT personal computer to the PT.
Screen saving methodSaved to flash memory: 32 KB (downloading method)

NT21

General Specifications

ItemSpecification
Power supply voltage24 VDC 15%
Power consumption7 W max.
Noise resistanceConforms to IEC61000-4-4. Power supply line: 2 kV
Vibration resistance10 to 57 Hz with 0.075-mm single amplitude, 
57 to 150 Hz with 9.8 m/s2 acceleration, 
for a total of 60 min in X, Y, and Z directions
Shock resistancePeak acceleration 15 G, 
3 times each in X, Y, and Z directions
Ambient operating temperature0 to 50°C (with no icing)
Storage temperature-20 to +70°C (with no icing)
Ambient operating humidity35% to 85% (with no condensation) (0 to 40°C) 
35% to 55% (with no condensation) (40 to 50°C)
Dimensions190 x 110 x 53.5 mm (W x H x D) (thickness inside panel: 49.0 mm)
Enclosure ratingsFront panel operating section: Equivalent to IP65F, NEMA 4.*
Weight0.6 kg max.
* Usage may not be possible in places where the unit would be exposed to oil for long periods.

Display Capacity

ItemSpecification
Display
elements
Fixed displaysA total of 65,535 per screen
(Graphics: Continuous straight lines, rectangles, circles, polygons, arcs, sectors)
With overlapping screens,
the total is 524,280 per screen
Fixed character strings
Graphics
Marks
Numeral displays256 positions per screen, max. 10-digit display (2 words)
Character string
displays
256 positions per screen, max.
1,024 display elements for overlapping screens
Graph displays50 positions per screen, capable of displaying signs and percentages
Analog meters50 positions per screen, capable of displaying signs and percentages
Trend graphsOne frame per screen, 50 items per frame
(8 items max. for data logging)
Broken line graphsOne frame per screen, 256 items per frame,
260 points per item
Lamps256 positions per screen
Image library images256 positions per screen
Touch switches256 positions per screen, max. 256 meshes
Numeral settings256 positions per screen
(numerical key pad)
Total of 256 positions for both numerical and thumbwheel settings
Thumbwheel settings26 positions per screen
Character string settings256 positions per screen
Temporary inputsOne position per screen
Alarm lists/historiesFour groups per screen
Screen
types
RecipesOne position per screen
Normal screensDisplays screens registered as normal
Overlapping screensA maximum of eight screens can be displayed overlapping each other.
WindowsUp to three window screens can be displayed.
Display history screensOrder of occurrence (1,024 screens max.), order of frequency (255 times max.)
System startup screenDisplayed when powering ON (or resetting ) the PT,and when switching to RUN mode.and when switching to RUN mode.
Programming Console screenEmulates PLC Programming Console functions, capable of being called from RUN mode.
Screen attributesBuzzer, display history, normal background colors,
backlight mode, local windows
Number of
screens
Max. number of registered screens3999
Screen number0: No display
1 to 3999: User registered screens
(normal, overlapping, windows)
9000: System startup screen
9001: Display history screens, order of occurrence
9002: Display history screens, order of frequency
9020: Programming Console screen
9999: Return to previous screen designation
Screen registration methodBy transferring screen data from the NT Support Tool to the PT via serial communications
By mounting the Memory Unit and downloading
(automatic/manual transfer) data to the PT
Saving screen dataFlash memory (PT internal image memory)

Display Specifications

ItemSpecification
Display panelDisplay deviceMonochrome STN LCD
Number of dots (resolution)260 dots horizontally x 140 dots vertically
Effective display area117 mm horizontally x 63 mm vertically
Viewing angleLeft/right direction:30°, up/down:30°
Display colorBlack & white (with blue mode)
Service life50,000 hours min. (until contrast reduced to 50%)
Automatic turn-OFFCan be set to turn OFF in 1 to 255 min or to
remain ON with screen saver
Backlight
(white cold cathode tube)
Service life50,000 hours min. (at room temperature,
until brightness is reduced to 50%)
ReplacementNon-replaceable

Panel Specifications

ItemSpecification
Touch panelNumber of switches91 (13 horizontally x 7 vertically)
InputPressure-sensitive
Threshold force for operation1 N max.
Life expectancy1 million operations min.

External Interface Specifications

Communications methodSerial port ASerial port B
NT Support ToolSupportedSupported
PLCHost LinkSupportedSupported
1:1 NT LinkSupportedSupported
1:N NT LinksSupportedSupported
NT Link, PT Programming Console functionSupportedSupported
SBC/personal computerMemory LinksSupportedNot supported
Bar Code ReaderSupportedNot supported
* Connection via RS-422A/485 is possible using the NS-AL002 RS-232C/422A Adapter (connector), which can be 
   connected only to serial port B. (RS-485 connections must use 1:N NT Links.)

Tidak ada komentar: