Item Model |
|
|
|
Appearance
|
| | |
Power supply and capacity
|
Three-phase 200 V
|
0.2 to 7.5 kW
|
0.1 to 15 kW
|
0.4 to 55 kW
|
Single-phase/three-phase 200 V
|
0.2 to 2.2 kW
|
0.1 to 2.2 kW
|
None
|
Three-phase 400 V
|
0.4 to 7.5 kW
|
0.4 to 15 kW
|
0.4 to 132 kW
|
Control method
|
V/f control
|
•
|
•
|
•
|
Sensorless vector control
|
|
•
|
•
|
Vector control with a PG
|
|
|
•
|
Input/output
|
No. of multi-function I/O points
|
• 5 inputs • 1 transistor output • 1 relay output
|
• 7 inputs
• 2 transistor outputs
• 1 relay output
|
• 9 inputs (1 RUN (FWD) input + 8 multi-function inputs)
• 5 transistor outputs
• 1 relay output
|
Analog I/O
|
• 1 input (0 to 10 V, 4 to 20 mA)
• 1 output (0 to 10 V)
|
• 2 inputs (0 to 10 V, 4 to 20 mA)
• 1 output (0 to 10 V)
|
• 2 inputs
(1) 0 to 10 V, 4 to 20 mA
(2) 0 to ±10 V
• 2 outputs
(1) 0 to 10 V
(2) 4 to 20 mA
• 1 PWM voltage output
|
Safety
| Dual STO output | |
•
| |
EDM output | |
•
| |
Braking
|
Braking resistor connection
|
|
•
|
• (22 kW max.)
|
Regenerative Braking Unit connection
|
•
|
•
|
•
|
Regenerative Braking Unit + braking resistor connection
|
•
|
•
|
•
|
Frequency
|
Frequency setting range
|
0.5 to 400 Hz
|
0.1 to 400 Hz
|
0.1 to 400 Hz
|
Frequency output method
|
Line-to-line sine wave PWM
|
Installation and wiring
|
Side-by-side mounting
|
•
|
•
|
|
Removable terminal block
| | |
•
|
Power supply and motor wiring
|
Top/bottom wiring
|
Bottom wiring
|
Noise counter-measures
|
Radio noise filter
|
Standard feature (built-in)
|
Optional (external)
|
Standard feature (built-in)
|
I/O noise filter
|
Optional (external)
|
EMC filter
|
Optional (external)
|
Standard feature (built-in)
|
Operation
|
Digital Operator
|
Fixed Digital Operator (with adjustment dial)
|
Fixed Digital Operator (without adjustment dial)
|
Removable Digital Operator (without adjustment dial)
|
Autotuning
|
|
•
|
•
|
Main functions
|
Multistep speed control
|
16 steps + jog
|
Carrier frequency setting
|
2 to 12 kHz (default setting: 3 kHz)
|
2 to 15 kHz (default setting: 10 kHz)
|
2 to 15 kHz (default setting: 5 kHz)
|
Torque assist function
|
Manual + auto torque assist
|
Auto (simple)/manual torque assist
|
Auto/manual torque assist
|
PID function
|
•
|
•
|
•
|
Absolute value positioning
|
|
•
|
•
|
Emergency shutoff
|
•
|
•
|
•
|
0-Hz domain sensorless vector control
|
| |
•
|
Tripless function
|
•
|
•
|
•
|
Momentary power interruption restart
|
•
|
•
|
•
|
Automatic energy saving
|
•
| |
•
|
Communications
|
MODBUS-RTU
|
•
|
•
|
•
|
RoHS
|
•
|
•
|
•
|
Safety standards
|
CE
|
•
|
•
|
•
|
UL/cUL
|
•
|
•
|
•
|
PLd
| |
•
(ISO 13849-1: 2006)
|
Tidak ada komentar: