Dirancang untuk kinerja yang sangat baik dan sangat mudah untuk digunakan.
1-phase 100V | 0.4kW, 0.75kW |
1-phase 200V | 0.1 - 2.2kW |
3-phase 200V | 0.1 - 15kW |
3-phase 400V | 0.4 - 15kW |
Models WJ200 Series
1 phase 100V
- WJ200-001SF(0.1 kW)
- WJ200-002SF(0.2 kW)
- WJ200-004SF(0.4 kW)
- WJ200-007SF(0.75 kW)
- Wj200-015SF(1.5 kW)
- WJ200-022SF(2.2 kW)
- WJ200-001LF(3-phase 200V 0.1 kW)
- WJ200-002LF(3-phase 200V 0.2 kW)
- WJ200-004LF(3-phase 200V 0.4 kW)
- WJ200-007LF(3-phase 200V 0.75 kW)
- WJ200-015LF(3-phase 200V 1.5 kW)
- WJ200-022LF(3-phase 200V 2.2 kW)
- WJ200-037LF(3-phase 200V 3.7 kW)
- WJ200-055LF(3-phase 200V 5.5 kW)
- WJ200-075LF(3-phase 200V 7.5 kW)
- WJ200-110LF(3-phase 200V 11 kW)
- WJ200-150LF(3-phase 200V 15 kW)
- WJ200-004HF(3-phase 400V 0.4kW)
- WJ200-007HF(3-phase 400V 0.75kW)
- Wj200-015HF(3-phase 400V 1.5kW)
- WJ200-022HF(3-phase 400V 2.2kW
- WJ200-030HF(3-phase 400V 3kW)
- WJ200-040HF(3-phase 400V 4kW)
- WJ200-055HF(3-phase 400V 5.5kW)
- WJ200-075HF(3-phase 400V 7.5kW)
- WJ200-110HF(3-phase 400V 11kW)
- WJ200-150HF(3-phase 400V 15kW)
Fungsi auto-tuning yang terintegrasi untuk sensor pengendalian vektor dengan mudah didapatkan torsi tinggi cocok untuk aplikasi yang memerlukan torsi tinggi seperti crane hoists, lift, elevator, dll.
Auto-tuning untuk melakukan kontrol vektor tanpa sensor sekarang dapat dengan mudah dilakukan.
Auto-tuning untuk melakukan kontrol vektor tanpa sensor sekarang dapat dengan mudah dilakukan.
- High starting torque and dramatically improved speed stability thanks to advanced sensorless vector control
- Simplified autotuning procedure
- Easy setup and operation via standard integral keypad, optional enhanced keypad or via PC software
- Dynamic braking transistor in all models
- EasySequence (EzSQ) PLC-like functionality built in
- Simple position control capability
- Capable of driving permanent magnet as well as standard induction motors
- Dual rated for CT/VT applications
- New and more effective trip avoidance functions, safe-stop function and much more…
Hitachi Inverter WJ200 Series dapat dengan mudah dioperasikan dengan operator digital yang disediakan sebagai standar.
(1) | POWER LED | Turns ON (Green) while the inverter is powered up.to the drive is ON. |
---|---|---|
(2) | ALARM LED | Turns ON (Red) when the inverter trips. |
(3) | Program LED> | Turns ON (Green) when the display shows changeable parameter. |
(4) | RUN LED | Turns ON (Green) when the inverter is driving the motor. |
(5) | Monitor LED [Hz] | Turns ON (Green) when the displayed data is frequency related. |
(6) | Monitor LED [A] | Turns ON (Green) when the displayed data is current related. |
(7) | Run command LED | Turns ON (Green) when a Run command is set to the operator. (Run key is effective.) |
(8) | 7-seg LED | Shows each parameter, monitors etc. |
(9) | RUN key | Makes inverter run. |
(10) | Stop/reset key | Makes inverter decelerates to a stop. |
(11) | Escape key | Go to the top of next function group, when a function mode is shown |
(12) | Up key | Press up or down to sequence through parameters and functions shown on the display, and increment/decrement values. |
(13) | Down key | |
(14) | Set key | Function code: It moves to the data display. Data code: Press to write the new value to the EEPROM. |
(15) | USB connector | Connect USB connector (mini-B) for using PC communication |
(16) | RJ45 onnector | Connect RJ45 jack for remote operator |
Tidak ada komentar:
Posting Komentar