The smallest gets integrated...
Easy network integration
The RS-485 Modbus is built into the RS-485 port in the inverter front, making it very easy to add inverters into the network without any extra option boards. Therefore, saving money and space.
Easy communications setting
Modbus commands are implemented even in low end CP1 PLC family by Modbus-RTU Easy Master functionality, making it easier than ever to integrate the inverters into the network.
Noise Measures for Peripheral Equipment
As a noise measure, a built-in radio noise filter is a standard feature on every model* that saves on costs and space compared with the standard external filter solution.
* Excluding single-phase/three-phase 200-V models.
* Excluding single-phase/three-phase 200-V models.
No additional devices required
Even advanced functionality such as PID control is standard with the JX inverter making it a convenient solution for applications such as pumps & fans where pressure, flow and other processes need controlling.
Automatic Energy-saving Function
This function automatically minimizes the Inverter output power during constant speed operation. It has a large energy-saving effect when used with fans and pumps.
Side-by-side Mounting Saves Space
When several Inverters are to be mounted in a control panel, side-by-side mounting makes it possible to mount them closely together, thus saving space.
Note: Some models have restrictions in the ambient temperature, carrier frequency, and output current.
Note: Some models have restrictions in the ambient temperature, carrier frequency, and output current.
3G3JX Inverter Models
Rated voltage | Enclosure rating | Max. applicable motor capacity | Model |
---|---|---|---|
3-phase 200 V AC | IP20 | 0.2 kW | 3G3JX-A2002 |
0.4 kW | 3G3JX-A2004 | ||
0.75 kW | 3G3JX-A2007 | ||
1.5 kW | 3G3JX-A2015 | ||
2.2 kW | 3G3JX-A2022 | ||
3.7 kW | 3G3JX-A2037 | ||
5.5 kW | 3G3JX-A2055 | ||
7.5 kW | 3G3JX-A2075 | ||
1/3-phase 200 V AC | 0.2 kW | 3G3JX-AE002 | |
0.4 kW | 3G3JX-AE004 | ||
0.75 kW | 3G3JX-AE007 | ||
1.5 kW | 3G3JX-AE015 | ||
2.2 kW | 3G3JX-AE022 | ||
3-phase 400 V AC | 0.4 kW | 3G3JX-A4004 | |
0.75 kW | 3G3JX-A4007 | ||
1.5 kW | 3G3JX-A4015 | ||
2.2 kW | 3G3JX-A4022 | ||
3.7 kW | 3G3JX-A4037 | ||
5.5 kW | 3G3JX-A4055 | ||
7.5 kW | 3G3JX-A4075 |
Related Options
Name | Specifications | Model | |
---|---|---|---|
Regenerative Braking Units | 3-phase 200 VAC | General purpose with Braking resistor | 3G3AX-RBU21 |
High Regeneration purpose with Braking resistor | 3G3AX-RBU22 | ||
3-phase 400 VAC | General purpose with Braking resistor | 3G3AX-RBU41 | |
Braking Resistor | Compact type | Resistor 120 W, 180 Ω | 3G3AX-RBA1201 |
Resistor 120 W, 100 Ω | 3G3AX-RBA1202 | ||
Resistor 120 W, 50 Ω | 3G3AX-RBA1203 | ||
Resistor 120 W, 35 Ω | 3G3AX-RBA1204 | ||
Standard type | Resistor 200 W, 180 Ω | 3G3AX-RBB2001 | |
Resistor 200 W, 100 Ω | 3G3AX-RBB2002 | ||
Resistor 300 W, 50 Ω | 3G3AX-RBB3001 | ||
Resistor 400 W, 35 Ω | 3G3AX-RBB4001 | ||
Medium capacity type | Resistor 400 W, 50 Ω | 3G3AX-RBC4001 | |
Resistor 600 W, 35 Ω | 3G3AX-RBC6001 | ||
Resistor 1200 W, 17 Ω | 3G3AX-RBC12001 |
Regenerative Braking Unit and Braking Resistor Combination
(1) Inverter specifications (choose voltage, capacity, and model)
The content noted in the table assumes the case of combining one Inverter and one motor of the same capacity.
(2) Select the %ED.
Use the %ED that is equivalent to or lower than the value shown.
(3) This shows the model and number of regenerative braking units and braking resistors.
(4) This provides a summary of the connection configuration of the regenerative braking unit and braking resistor.
Refer to the "Connection configuration"
(5) The specified conditions contain restrictions. Make sure there are not any issues
The content noted in the table assumes the case of combining one Inverter and one motor of the same capacity.
(2) Select the %ED.
Use the %ED that is equivalent to or lower than the value shown.
(3) This shows the model and number of regenerative braking units and braking resistors.
(4) This provides a summary of the connection configuration of the regenerative braking unit and braking resistor.
Refer to the "Connection configuration"
(5) The specified conditions contain restrictions. Make sure there are not any issues
Inverter | Usage conditions | Regenerative braking unit | Braking resistor | Con- nec- tion con- figu- ration | Restrictions | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Volt- age | Max. appli- cable motor ca- pacity (kW) | Mode | %ED *1 (%) | Ap- proxi- mate braking torque (% *2) | Model | Num- ber of units | Model | Num- ber of units | Allowa- ble contin- uous braking time (s) | Min. con- nect- able resis- tance (Ω) | |
200-V Class | 0.2 | 3G3JX- A2002 3G3JX- AE002 | 3.0% | 220% | 3G3AX- RBU21 | 1 | Built-in Inverter | --- | 10 | 10 | 17 |
10.0% | 220% | 1 | 10 | 10 | 17 | ||||||
0.4 | 3G3JX- A2004 3G3JX- AE004 | 3.0% | 220% | 3G3AX- RBU21 | 1 | Built-in Inverter | --- | 10 | 10 | 17 | |
10.0% | 220% | 1 | 10 | 10 | 17 | ||||||
0.75 | 3G3JX- A2007 3G3JX- AE007 | 3.0% | 120% | 3G3AX- RBU21 | 1 | Built-in Inverter | --- | 10 | 10 | 17 | |
10.0% | 120% | 1 | 10 | 10 | 17 | ||||||
1.5 | 3G3JX- A2015 3G3JX- AE015 | 2.5% | 110% | 3G3AX- RBU21 *3 | 1 | 3G3AX-RBA1202 | 1 | 11 | 12 | 17 | |
10.0% | 215% | 1 | 3G3AX-RBC4001 | 1 | 11 | 10 | 17 | ||||
2.2 | 3G3JX- A2022 3G3JX- AE022 | 3.0% | 150% | 3G3AX- RBU21 *3 | 1 | 3G3AX-RBB3001 | 1 | 11 | 30 | 17 | |
10.0% | 150% | 1 | 3G3AX-RBC4001 | 1 | 11 | 10 | 17 | ||||
3.7 | 3G3JX- A2037 | 3.0% | 125% | 3G3AX- RBU21 *3 | 1 | 3G3AX-RBB4001 | 1 | 11 | 20 | 17 | |
10.0% | 125% | 1 | 3G3AX-RBC6001 | 1 | 11 | 10 | 17 | ||||
5.5 | 3G3JX- A2055 | 3.0% | 120% | 3G3AX- RBU21 *3 | 1 | 3G3AX-RBB3001 | 2 | 12 | 30 | 17 | |
10.0% | 120% | 1 | 3G3AX-RBC4001 | 2 | 12 | 10 | 17 | ||||
7.5 | 3G3JX- A2075 | 3.0% | 125% | 3G3AX- RBU21 *3 | 1 | 3G3AX-RBB4001 | 2 | 12 | 20 | 17 | |
10.0% | 130% | 1 | 3G3AX-RBC12001 | 1 | 11 | 10 | 17 | ||||
400-V Class | 0.4 | 3G3JX- A4004 | 3.0% | 220% | 3G3AX- RBU41 *3 | 1 | Built-in Inverter | --- | 21 | 10 | 34 |
10.0% | 220% | 1 | 21 | 10 | 34 | ||||||
0.75 | 3G3JX- A4007 | 3.0% | 220% | 3G3AX- RBU41 *3 | 1 | Built-in Inverter | --- | 21 | 10 | 34 | |
10.0% | 220% | 1 | 21 | 10 | 34 | ||||||
1.5 | 3G3JX- A4015 | 3.0% | 120% | 3G3AX- RBU41 *3 | 1 | Built-in Inverter | --- | 21 | 10 | 34 | |
10.0% | 120% | 1 | 21 | 10 | 34 | ||||||
2.2 | 3G3JX- A4022 | 2.5% | 150% | 3G3AX- RBU41 *3 | 1 | 3G3AX-RBA1202 | 2 | 13 | 12 | 34 | |
10.0% | 220% | 1 | 3G3AX-RBC4001 | 2 | 13 | 10 | 34 | ||||
3.7 | 3G3JX- A4037 | 3.0% | 175% | 3G3AX- RBU41 *3 | 1 | 3G3AX-RBB3001 | 2 | 13 | 30 | 34 | |
10.0% | 175% | 1 | 3G3AX-RBC4001 | 2 | 13 | 10 | 34 | ||||
5.5 | 3G3JX- A4055 | 3.0% | 120% | 3G3AX- RBU41 *3 | 1 | 3G3AX-RBB3001 | 2 | 13 | 30 | 34 | |
10.0% | 120% | 1 | 3G3AX-RBC4001 | 2 | 13 | 10 | 34 | ||||
7.5 | 3G3JX- A4075 | 3.0% | 125% | 3G3AX- RBU41 *3 | 1 | 3G3AX-RBB4001 | 2 | 13 | 20 | 34 | |
10.0% | 125% | 1 | 3G3AX-RBC6001 | 2 | 13 | 10 | 34 |
*1 %ED shows the ratio that can be used for braking (deceleration time) among operating time of one task period.
*2 Approximate breaking torque is shown in % of rating torque of the motor (100%).
*3 Please remove the built-in resistor.
Note: When the torque more than the approximate braking torque is required or it is necessary to use more frequently
than %ED, the selection including the load calculation instead of the combination list is required.
*2 Approximate breaking torque is shown in % of rating torque of the motor (100%).
*3 Please remove the built-in resistor.
Note: When the torque more than the approximate braking torque is required or it is necessary to use more frequently
than %ED, the selection including the load calculation instead of the combination list is required.
Name | Specifications of Inverter | Model | |
---|---|---|---|
Voltage class | Applicable capacity (kW) | ||
Radio Noise Filter | 3-phase 200 VAC | 0.2 | 3G3AX-ZCL2 |
0.4 | |||
0.75 | |||
1.1 | |||
2.2 | |||
3 | |||
5.5 | 3G3AX-ZCL1 (3G3AX-ZCL2) | ||
7.5 | |||
1/3-phase 200 VAC | 0.2 | 3G3AX-ZCL2 | |
0.4 | |||
0.55 | |||
1.1 | |||
2.2 | |||
3-phase 400 VAC | 0.75 | 3G3AX-ZCL2 (3G3AX-ZCL1) | |
1.5 | |||
2.2 | |||
3 | |||
4 | |||
5.5 | |||
7.5 | |||
Input Noise Filter | 3-phase 200 VAC | 0.2 to 0.75 | 3G3AX-NFI21 |
1.5 | 3G3AX-NFI22 | ||
2.2, 3.7 | 3G3AX-NFI23 | ||
5.5 | 3G3AX-NFI24 | ||
7.5 | 3G3AX-NFI25 | ||
3-phase 400 VAC | 0.4 to 2.2 | 3G3AX-NFI41 | |
3.7 | 3G3AX-NFI42 | ||
5.5, 7.5 | 3G3AX-NFI43 | ||
EMC-compatible Noise Filter | 1-phase 200 VAC | 0.2, 0.4 | 3G3AX-EFIB1 |
0.75 | 3G3AX-EFIB2 | ||
1.5, 2.2 | 3G3AX-EFIB3 | ||
3-phase 200 VAC | 0.2, 0.4 | 3G3AX-EFI21 | |
0.75 | 3G3AX-EFI22 | ||
1.5, 2.2 | 3G3AX-EFI23 | ||
3.7 | 3G3AX-EFI24 | ||
5.5, 7.5 | 3G3AX-EFI25 | ||
0.4, 0.75 | 3G3AX-EFI41 | ||
1.5 | 3G3AX-EFI42 | ||
2.2, 3.7 | 3G3AX-EFI43 | ||
5.5 | 3G3AX-EFI44 | ||
7.5 | 3G3AX-EFI45 | ||
3-phase 200/400 VAC | 0.4 to 1.5 | 3G3AX-EFI22 | |
2.2, 3.7 | 3G3AX-EFI23 | ||
5.5, 7.5 | 3G3AX-EFI25 | ||
0.4 to 2.2 | 3G3AX-EFI41 | ||
3.7 | 3G3AX-EFI42 | ||
5.5, 7.5 | 3G3AX-EFI43 | ||
Output Noise Filter | 3-phase 400 VAC | Applicable motor 200-V Class: to 0.75 400-V Class: to 2.2 | 3G3AX-NFO01 |
Applicable motor 200-V Class: 1.5, 2.2 400-V Class: 3.7 | 3G3AX-NFO02 | ||
Applicable motor 200-V Class: 3.7, 5.5 400-V Class: 5.5, 7.5 | 3G3AX-NFO03 | ||
Applicable motor 200-V Class: 7.5 | 3G3AX-NFO04 | ||
DC Reactor | 1/3-phase 200 VAC | 0.2 | 3G3AX-DL2002 |
0.4 | 3G3AX-DL2004 | ||
0.75 | 3G3AX-DL2007 | ||
1.5 | 3G3AX-DL2015 | ||
2.2 | 3G3AX-DL2022 | ||
3.7 | 3G3AX-DL2037 | ||
5.5 | 3G3AX-DL2055 | ||
7.5 | 3G3AX-DL2075 | ||
3-phase 400 VAC | 0.4 | 3G3AX-DL4004 | |
0.75 | 3G3AX-DL4007 | ||
1.5 | 3G3AX-DL4015 | ||
2.2 | 3G3AX-DL4022 | ||
3.7 | 3G3AX-DL4037 | ||
5.5 | 3G3AX-DL4055 | ||
7.5 | 3G3AX-DL4075 | ||
AC Reactor | 3-phase 200 VAC | 0.2 to 1.5 | 3G3AX-AL2025 |
2.2, 3.7 | 3G3AX-AL2055 | ||
5.5, 7.5 | 3G3AX-AL2110 | ||
3-phase 400 VAC | 0.4 to 1.5 | 3G3AX-AL4025 | |
2.2, 3.7 | 3G3AX-AL4055 | ||
5.5, 7.5 | 3G3AX-AL4110 |
External Digital Operator
Name | Cable length | Model |
---|---|---|
Digital Operator | --- | 3G3AX-OP01 |
Connection cable | 1 m | 3G3AX-OPCN1 |
3 m | 3G3AX-OPCN3 |
Software
Name | Specifications | Model | ||
---|---|---|---|---|
Number of licenses | Media | |||
FA Integrated Tool Package CX-One Ver. 4.[] | The CX-One is a comprehensive software package that integrates Support Software for OMRON PLCs and components. CX-One runs on following OS. Windows XP (Service Pack 3 or higher, 32-bit version) / Windows Vista (32-bit/64-bit version) / Windows 7 (32-bit/64-bit version) / Windows 8(32-bit/64-bit version) / Windows 8.1(32-bit/64-bit version) CX-One Version.4.[] includes CX-Drive Ver.2.[]. For details, refer to the CX-One catalog (Cat. No.R134) | 1 license *1 | DVD *2 | CXONE-AL01D-V4 |
*1 Multi licenses are available for the CX-One (3, 10, 30, or 50 licenses).
*2 The CX-One is also available on CD (CXONE-AL[][]C-V4).
*2 The CX-One is also available on CD (CXONE-AL[][]C-V4).
Communications Cable
Name | Specifications | Model |
---|---|---|
Communications cable for CX-Drive | USB Cable for JX and RX series (2m) | 3G3AX-PCACN2 |