An extensive line-up lets you easily configure machines and production lines to meet your needs
SYSMAC CPM2A
Every CPM2A CPU comes equipped with an RS-232C interface as standard, e.g. to provide easy connection with a programmable Terminal for fast and easy machine monitoring, temperature setting, etc. Simple positioning with the pulse I/O function is another example of the many advanced functions is and high added value that the CPM2A brings to compact machines. Removable terminal blocks ensure easy maintenance , and the CPM2A uses the same Expansion I/O Units as the CPM1A for easy and economical sharing of system components.
CPU Units with AC Power supply
Relay Output CPU Unit
CPM2A-20CDR-A
Input points; 12 , DC input
Output points: 8
Relay Output CPU Unit
CPM2A-40CDR-A
Input points: 24, DC input
Output points 16
Relay Output CPU Unit
CPM2A-30CDR-A
Input points: 18, DC input
Output points: 12
Relay Output CPU Unit
CPM2A-60CDR-A
Input points: 36, DC input
Output points: 24
CPU Units with DC Power Supply
Relay Output CPU Unit
CPM2A-20CDR-D
Transistor Output CPU Units
CPM2A-20CDT-D (Sink)
CPM2A-20CDT1-D (Source)
Input points: 12, DC input
Output points: 8
Relay Output CPU Unit
CPM2A-40CDR-D
Transistor Output CPU Units
CPM2A-40CDT-D (Sink)
CPM2A-40CDT1-D (source)
Input points: 24, DC input
Output points : 16
Relay Output CPU Unit
CPM2A-30CDR-D
Transistor Output CPU Units
CPM2A-30CDT-D (Sink)
CPM2A-30CDT1-D (Source)
Input points: 18, DC input
Output points: 12
Relay Output CPU Unit
CPM2A-60CDR-D
Transistor Output CPU Units
CPM2A-60CDT-D (Sink)
CPM2A-60CDT1-D (Source)
Input points: 36, DC input\
Output points: 24
Expansion I/O Units
CPM1A-8ED
Input pouint: 8, DC input
CPM1A-8ER
Output point: 8 ,RY output
CPM1A-8ET
Output pointts: 8, TR output (Sink)
CPM1A-8ET1
Output points: 8, TR output (Source)
CPM1A-20EDR1
Input point: 12, DC input
Output point: 8, RY output
CPM1A-20EDT
Input point: 12, DC input
Output point: 8, TR output (Sink)
CPM1A-20EDT1
Input points: 12, DC input
Output points: 8, TR output (Source)
Analog I/O Units
CPM1A-MAD01
(Resolution:256)
CPM1A-MAD11
2 inputs + 1 output
CPM1A-AD041 (4 inputs)
CPM1A-DA041 (4 outputs)
DeviceNet
CPM1A-DRT21
I/O Link
inputs: 32
I/O Link o
output: 32
PROFIBUS-DP
CPM1A-PRT21
I/O Link
inputs: 16
I/O Link
Outputs: 16
CompoBus/S
CompoBus/S
I/O Unit
CPM1A-SRT21
I/O Link inputs: 8
I/O Link outputs: 8
Temperature Sensor Units
CPM1A-TS001
Thermocouple inputs:2
CPM1A-TS002
Thermocouple Inputs: 4
CPM1A-TS101
Pt 100 inputs: 2
CPM1A-TS-101-DA
Pt100 inputs: 1
CPM1A-TS102
Pt100 inputs: 4
Tidak ada komentar: