FR-F700P
Features Series
- Great CO2 emission reduction with energy-saving drive.
Optimum excitation control continuously adjusts the highest motor efficiency leading to substantial energy savings. This Series can drive both a general-purpose motor and an IPM motor. Switching between the two motor controls is simple-just a single parameter
- Easy-to-use
The following functions provide the ideal operation for fans and pumps: variable torque acceleration/deceleration patterns, PID control, commercial power supply switching, adjustable 5 points V/F, continuous avoidance function, etc.
- Environmentally friendly
The newly developed built-in EMC filter reduces electromagnetic noise generated from the inverter.
- Improved reliability and easy maintenance
The lives of the cooling fan and capacitor have been extended. Using the self-diagnosis function, the part live warning can be output and the degree of deterioration can be monitored to prevent malfunction . The removable control terminal block and the cooling fan cassette make it easy to replace.
Model
FR-F720P-3.7K
Specifications
Control Method : Soft-PWM control, high carrier frequency PWM control (V/F control and Optimum excitation control, Simple magnetic flux vector control, and IPM motor control can be selected)
Starting torque General motor control : 120% 3Hz, with Simple magnetic flux vector control and slip compensation.
Starting torque IPM motor control : 50%
Output frequency range General-purpose motor control : 0.5 to 400Hz
Output frequency range IPM motor control : MM-EF : 0 to 135Hz (30K or lower) / 0 to 160Hz (90K or higher) MM-EFS*1 : 0 to 112.5Hz (15K or lower) / 0 TO 150Hz (18K or higher)
Regenerative braking torque (Maximum value/permissible duty) General-purpose motor control : 0.75K to 55K ....15% continuous, 75K or higher.....10% continuos .
Regenerative braking torque (Maximum value/permissible duty) IPM motor control : Approximately 5% (1.5 or lower....Approximately 10%)
Acceleration/deceleration time setting : 0 to 3600s (up to two types of accelerations and decelerations can be set individually)
Multi-speed : 15 Speeds
Speed command : 0 to 5VDC . 0 to 10VDC , 0 to+5VDC , 0 to 10+VDC, 4 to 20mA, digital set with operation panel or parameter unit, 4-digit BCD or 16-bit binary (when using optional FR-A7AX)
Alarm output : 1 changeover contact (230VAC, 0.3A, 30VDC, 0.3A), open collector output, alarm code (4-bit) output
Output Signal : Five types of open collector output and two types of contacts outputs (changeover contact) can be selected from inverter running, up to frequency, instantaneous power failure (under voltage), frequency detection, operation ready, overload ready, overload warning, error output and alarm, etc.
Monitor function : One monitored item can be selected from output frequency, motor current (steady or peak value), output voltage, operation speed, converter output voltage, input power, output power and load meter, etc.
Restart after instantaneous power failure : Available (reduced voltage method (frequency search selectable))
Removable terminal block : Used for control circuit terminals
Communication function : RS-485 supported (Modbus-RTU) as standard, CC-Link , PROFIBUS-DP , DeviceNet, LonWorks, and FL remote options removable.