Kontak Kami

KONTAK KAMI : Telpon : 02126071413 Hp/WhatsApp : 081212269831 Perwakilan Jakarta : Gedung LTC Glodok Lantai 1 Blok C30 No.31 Jl.Hayam Wuruk No.127 Jakarta , Indonesia

Kamis, 26 April 2018

OMRON CP1E : CP1E-E10DR-A,CP1E-E10DR-D,CP1E-EDT-A,CP1E-E14DR-A,CP1E-E14SDR-A,CP1E-E20DR-A,CP1E-E20SDR-A,CP1E-E30DR-A,CP1E-E30SDR-A,CP1E-E40DR-A,CP1E-E40SDR-A,CP1E-E60SDR-A

CP1E-E10DR-A
CP1E-E10DR-D
CP1E-EDT-A
CP1E-E14DR-A
CP1E-E14SDR-A
CP1E-E20DR-A
CP1E-E20SDR-A
CP1E-E30DR-A
CP1E-E30SDR-A
CP1E-E40DR-A
CP1E-E40SDR-A
CP1E-E60SDR-A

MITSUBISHI Module Q Seri : Q00CPU,Q00JCPU,Q00UCPU,Q01UCPU,Q02CPU,Q02HCPU,Q02UCPU,Q03UDCPU,Q03UDECPU,Q04UDEHCPU,Q04UDHCPU,Q06HCPU,Q06UDEHCPU,Q06UDHCPU,Q35B,Q38B,Q38BL,Q52B,Q55B,Q62P,Q63B

Q00CPU
Q00JCPU
Q00UCPU
Q01UCPU
Q02CPU
Q02HCPU
Q02UCPU
Q03UDCPU
Q03UDECPU
Q04UDEHCPU
Q04UDHCPU
Q06HCPU
Q06UDEHCPU
Q06UDHCPU
Q35B
Q38B
Q38BL
Q52B
Q55B
Q62P
Q63B
Q65B
Q68B
Q6BAT
QX10
QX28
QX40
QX40-S1
QX41
QX41-S1
QX41-S2
QX50
QX70
QX71
QX72
QX80
QX81
QX81-S2
QX82
QX82-S1
QY10
QY10-TS
QY22
QY23L
QY40P-TS
QY41H
QY41P
QY42P
QY50
QY70
QY71
QY80
QY81P
QY82P


MITSUBISHI MR-J4 : MR-J4-10A,MR-J4-10B,MR-J4-20A,MR-J4-20B,MR-J4-40A,MR-J4-40B,MR-J4-60A,MR-J4-60B,MR-J4-70A,MR-J4-70B MR-J4-100A,MR-J4-100B,MR-J4-200A,MR-J4-200B,MR-J4-350A,MR-J4-350B,MR-J4-500A,MR-J4-500B,MR-J4-700A,MR-J4-700B

MR-J4-10A
MR-J4-10B
MR-J4-20A
MR-J4-20B
MR-J4-40A
MR-J4-40B
MR-J4-60A
MR-J4-60B
MR-J4-70A
MR-J4-70B
MR-J4-100A
MR-J4-100B
MR-J4-200A
MR-J4-200B
MR-J4-350A
MR-J4-350B
MR-J4-500A
MR-J4-500B
MR-J4-700A
MR-J4-700B

MITSUBISHI MR-J3 : MR-J3-10A,MR-J3-10B,MR-J3-20A,MR-J3-20B,MR-J3-40A,MR-J3-40B,MR-J3-60A,MR-J3-60B,MR-J3-70A,MR-J3-70B,MR-J3-100A,MR-J3-100B,MR-J3-350A,MR-J3-350B,MR-J3-500A,MR-J3-500B,MR-J3-700A,MR-J3-700B,MR-J3-BAT

MR-J3-10A
MR-J3-10B
MR-J3-20A
MR-J3-20B
MR-J3-40A
MR-J3-40B
MR-J3-60A
MR-J3-60B
MR-J3-70A
MR-J3-70B
MR-J3-100A
MR-J3-100B
MR-J3-350A
MR-J3-350B
MR-J3-500A
MR-J3-500B
MR-J3-700A
MR-J3-700B
MR-J3-BAT

MITSUBISHI FX5U : FX5U-32MR/ES,FX5U-32MT/ES,FX5U-64MR/ES,FX5U-64MT/ES,FX5U-80MR/ES,FX5U-80MT/ES

FX5U-32MR/ES
FX5U-32MT/ES
FX5U-64MR/ES
FX5U-64MT/ES
FX5U-80MR/ES
FX5U-80MT/ES
FX5UC-32MT/D
FX5UC-64MT/D
FX5UC-96MT/D

MITSUBISHI FX3U : FX3U-16MR/ES-A,FX3U-16MT/ES-A,FX3U-32MR/ES-A,FX3U-32MT/ES-A,FX3U-48MR/ES-A,FX3U-48MT/ES-A,FX3U-64MR/ES-A,FX3U-64MT/ES-A,FX3U-80MR/ES-A,FX3U-80MT/ES-A

FX3U-16MR/ES-A
FX3U-16MT/ES-A
FX3U-32MR/ES-A
FX3U-32MT/ES-A
FX3U-48MR/ES-A
FX3U-48MT/ES-A
FX3U-64MR/ES-A
FX3U-64MT/ES-A
FX3U-80MR/ES-A
FX3U-80MT/ES-A

MITSUBISHI FX3S : FX3S-14MR/ES,FX3S-14MT/ES,FX3S-20MR/ES,FX3S-20MT/ES,FX3S-30MR/ES,FX3S-30MT/ES

FX3S-14MR/ES
FX3S-14MT/ES
FX3S-20MR/ES
FX3S-20MT/ES
FX3S-30MR/ES
FX3S-30MT/ES

MITSUBISHI FX3G : FX3G-14MR/ES-A,FX3G-14MT/ES-A,FX3G-24MR/ES-A,FX3G-24MT/ES-A,FX3G-40MR/ES-A,FX3G-40MT/ES-A,FX3G-60MR/ES-A,FX3G-60MT/ES-A

FX3G-14MR/ES-A
FX3G-14MT/ES-A
FX3G-24MR/ES-A
FX3G-24MT/ES-A
FX3G-40MR/ES-A
FX3G-40MT/ES-A
FX3G-60MR/ES-A
FX3G-60MT/ES-A

MITSUBISHI FR-F840-[][]K-1 : FR-F840-0.75K-1,FR-F840-1.5K-1,FR-F840-2.2K-1,FR-F840-3.7K-1,FR-F840-5.5K-1,FR-F840-7.5K-1,FR-F840-11K-1,FR-F840-15K-1,FR-F840-18.5K-1,FR-F840-22K-1,FR-F840-30K-1,FR-F840-37K-1,FR-F840-45K-1,FR-F840-55K-1,FR-F840-75K-1,FR-F840-90K-1,FR-F840-110K-1,FR-F840-132K-1,FR-F840-160K-1,FR-F840-185K-1,FR-F840-220K-1,FR-F840-250K-1,FR-F840-280K-1,FR-F840-315K-1

FR-F840-0.75K-1
FR-F840-1.5K-1
FR-F840-2.2K-1
FR-F840-3.7K-1
FR-F840-5.5K-1
FR-F840-7.5K-1
FR-F840-11K-1
FR-F840-15K-1
FR-F840-18.5K-1
FR-F840-22K-1
FR-F840-30K-1
FR-F840-37K-1
FR-F840-45K-1
FR-F840-55K-1
FR-F840-75K-1
FR-F840-90K-1
FR-F840-110K-1
FR-F840-132K-1
FR-F840-160K-1
FR-F840-185K-1
FR-F840-220K-1
FR-F840-250K-1
FR-F840-280K-1
FR-F840-315K-1

MITSUBISHI FR-A840-[][]K-1 : FR-A840-0.4K-1,FR-A840-0.75K-1,FR-A840-1.5K-1,FR-A840-2.2K-1,FR-A840-3.7K-1,FR-A840-5.5K-1,FR-A840-7.5K-1,FR-A840-11K-1,FR-A840-15K-1,FR-A840-18.5K-1,FR-A840-22K-1,FR-A840-30K-1,FR-A840-37K-1,FR-A840-45K-1,FR-A840-55K-1,FR-A840-75K-1,FR-A840-90K-1,FR-A840-110K-1,FR-A840-132K-1,FR-A840-160K-1,FR-A840-185K-1,FR-A840-220K-1,FR-A840-250K-1,FR-A840-280K-1

FR-A840-0.4K-1
FR-A840-0.75K-1
FR-A840-1.5K-1
FR-A840-2.2K-1
FR-A840-3.7K-1
FR-A840-5.5K-1
FR-A840-7.5K-1
FR-A840-11K-1
FR-A840-15K-1
FR-A840-18.5K-1
FR-A840-22K-1
FR-A840-30K-1
FR-A840-37K-1
FR-A840-45K-1
FR-A840-55K-1
FR-A840-75K-1
FR-A840-90K-1
FR-A840-110K-1
FR-A840-132K-1
FR-A840-160K-1
FR-A840-185K-1
FR-A840-220K-1
FR-A840-250K-1
FR-A840-280K-1

MITSUBISHI FR-F820-[][]K-1: FR-F820-0.75K-1,FR-F820-1.5K-1,FR-F820-2.2K-1,FR-F820-3.7K-1,FR-F820-5.5K-1,FR-F820-7.5K-1,FR-F820-11K-1,FR-F820-15K-1,FR-F820-18.5K-1,FR-F820-22K-1,FR-F820-30K-1,FR-F820-37K-1,FR-F820-45K-1,FR-F820-55K-1,FR-F820-75K-1,FR-F820-90K-1,FR-F820-110K-1

FR-F820-0.75K-1
FR-F820-1.5K-1
FR-F820-2.2K-1
FR-F820-3.7K-1
FR-F820-5.5K-1
FR-F820-7.5K-1
FR-F820-11K-1
FR-F820-15K-1
FR-F820-18.5K-1
FR-F820-22K-1
FR-F820-30K-1
FR-F820-37K-1
FR-F820-45K-1
FR-F820-55K-1
FR-F820-75K-1
FR-F820-90K-1
FR-F820-110K-1

MITSUBISHI FR-A820-[][]K-1 : FR-A820-0.4K-1,FR-A820-0.75K-1,FR-A820-1.5K-1,FR-A820-2.2K-1,FR-A820-3.7K-1,FR-A820-5.5K-1,FR-A820-7.5K-1,FR-A820-11K-1,FR-A820-15K-1,FR-A820-18.5K-1,FR-A820-22K-1,FR-A820-30K-1,FR-A820-37K-1,FR-A820-45K-1,FR-A820-55K-1,FR-A820-75K-1,FR-A820-90K-1

FR-A820-0.4K-1
FR-A820-0.75K-1
FR-A820-1.5K-1
FR-A820-2.2K-1
FR-A820-3.7K-1
FR-A820-5.5K-1
FR-A820-7.5K-1
FR-A820-11K-1
FR-A820-15K-1
FR-A820-18.5K-1
FR-A820-22K-1
FR-A820-30K-1
FR-A820-37K-1
FR-A820-45K-1
FR-A820-55K-1
FR-A820-75K-1
FR-A820-90K-1

MITSUBISHI FX1N : FX1N-20MR-ES/UL,FX1N-24MR-ES/UL,FX1N-40MR-ES/UL,FX1N-60MR-ES/UL

FX1N-20MR-ES/UL
FX1N-24MR-ES/UL
FX1N-40MR-ES/UL
FX1N-60MR-ES/UL

Jumat, 13 April 2018

MITSUBISHI MR-J2S-60A



  • Power Supply (Voltage/frequency): 3-phase 200-230VAC, 50/60Hz; 1-phase 230VAC, 50/60Hz
  • Power Supply (Permissible voltage fluctuation): 3-phase 200-230VAC, 170-253VAC 

  • Power Supply (Permissible frequency fluctuation): ±5%
  • Control System: Sinusoidal PWM control/current control system
  • Dynamic brake: Built-in
  • Speed frequency response: 550 Hz or more
  • Protective functions: Overcurrent shutdown, regeneration overvoltage shutdown, overload shutdown (electronic thermal), servomotor overheat protection, encoder fault protection, regeneration fault protection, undervoltage/sudden power outage protection,overspeed protection, excess error protection
  • Maximum input pulse frequency (Position control mode): 500 kpps- when using differential receiver, 200 kpps- when using open collector
  • Positioning feedback pulse (Position control mode): Resolution per encoder/servo motor rotation (131072 pulse/revolution)
  • Positioning complete width setting (Position control mode): 0 - ±10VDC
  • Excess error (Position control mode): ±10 rotations
  • Torque limit input (Position control mode): Set by parameters or external analog input (0-±10VDC / maximum torque)
  • Speed control range (Speed control mode): Analog speed command 1:2000, internal speed command 1:5000
  • Analog speed command input (Speed control mode): 0-±10VDC / rated speed
  • Speed fluctuation rate (Speed control mode): ±0.01% max.(load fluctuation 0-100%), 0% (power fluctuation ±10%), ±0.2% max. (ambient temperature 25°C ± 10°C), when using external analog speed command
  • Torque limit (Speed control mode): Set by parameters or external analog input (0-±10VDC / maximum torque)
  • Torque command input (Torque control specifications): 0-±8VDC / maximum torque (input impedance 10 to 12kΩ)
  • Speed limit (Torque control specifications): Set by parameters or external analog input (0-±10VDC, rated speed)
  • Structure: Self-cooling, open (IP00) 
  • Shipping Weight: 2.6 kg

MITSUBISHI MR-J2S-200A




  • Power Supply (Voltage/frequency): 3-phase 200-230VAC, 50/60Hz
  • Power Supply (Permissible voltage fluctuation): 3-phase 170-253VAC
  • Power Supply (Permissible frequency fluctuation): ±5%
  • Control System: Sinusoidal PWM control/current control system
  • Dynamic brake: Built-in
  • Speed frequency response: 550 Hz or more
  • Protective functions: Overcurrent shutdown, regeneration overvoltage shutdown, overload shutdown (electronic thermal), servomotor overheat protection, encoder fault protection, regeneration fault protection, undervoltage/sudden power outage protection,overspeed protection, excess error protection
  • Maximum input pulse frequency (Position control mode): 500 kpps- when using differential receiver, 200 kpps- when using open collector
  • Positioning feedback pulse (Position control mode): Resolution per encoder/servo motor rotation (131072 pulse/revolution)
  • Positioning complete width setting (Position control mode): 0 - ±10VDC
  • Excess error (Position control mode): ±10 rotations
  • Torque limit input (Position control mode): Set by parameters or external analog input (0-±10VDC / maximum torque)
  • Speed control range (Speed control mode): Analog speed command 1:2000, internal speed command 1:5000
  • Analog speed command input (Speed control mode): 0-±10VDC / rated speed
  • Speed fluctuation rate (Speed control mode): ±0.01% max.(load fluctuation 0-100%), 0% (power fluctuation ±10%), ±0.2% max. (ambient temperature 25°C ± 10°C), when using external analog speed command
  • Torque limit (Speed control mode): Set by parameters or external analog input (0-±10VDC / maximum torque)
  • Torque command input (Torque control specifications): 0-±8VDC / maximum torque (input impedance 10 to 12kΩ)
  • Speed limit (Torque control specifications): Set by parameters or external analog input (0-±10VDC, rated speed)
  • Structure: Fan-cooling, open (IP00) 
  • Shipping Weight: 3.1 kg

MITSUBISHI MR-J2S-100A



  • Power Supply (Voltage/frequency): 3-phase 200-230VAC, 50/60Hz
  • Power Supply (Permissible voltage fluctuation): 3-phase 170-253VAC
  • Power Supply (Permissible frequency fluctuation): ±5%
  • Control System: Sinusoidal PWM control/current control system
  • Dynamic brake: Built-in
  • Speed frequency response: 550 Hz or more
  • Protective functions: Overcurrent shutdown, regeneration overvoltage shutdown, overload shutdown (electronic thermal), servomotor overheat protection, encoder fault protection, regeneration fault protection, undervoltage/sudden power outage protection,overspeed protection, excess error protection
  • Maximum input pulse frequency (Position control mode): 500 kpps- when using differential receiver, 200 kpps- when using open collector
  • Positioning feedback pulse (Position control mode): Resolution per encoder/servo motor rotation (131072 pulse/revolution)
  • Positioning complete width setting (Position control mode): 0 - ±10VDC
  • Excess error (Position control mode): ±10 rotations
  • Torque limit input (Position control mode): Set by parameters or external analog input (0-±10VDC / maximum torque)
  • Speed control range (Speed control mode): Analog speed command 1:2000, internal speed command 1:5000
  • Analog speed command input (Speed control mode): 0-±10VDC / rated speed
  • Speed fluctuation rate (Speed control mode): ±0.01% max.(load fluctuation 0-100%), 0% (power fluctuation ±10%), ±0.2% max. (ambient temperature 25°C ± 10°C), when using external analog speed command
  • Torque limit (Speed control mode): Set by parameters or external analog input (0-±10VDC / maximum torque)
  • Torque command input (Torque control specifications): 0-±8VDC / maximum torque (input impedance 10 to 12kΩ)
  • Speed limit (Torque control specifications): Set by parameters or external analog input (0-±10VDC, rated speed)
  • Structure: Self-cooling, open (IP00) 
  • Shipping Weight: 3 Kg

MITSUBISHI MR-J2S-100B





  • Manufacturer : Mitsubishi Electric
  • Power Supply (Voltage/frequency): 3-phase 200-230VAC, 50/60Hz
  • Power Supply (Permissible voltage fluctuation): 3-phase 170-253VAC
  • Power Supply (Permissible frequency fluctuation): ±5%
  • Control System: Sinusoidal PWM control/current control system
  • Dynamic brake: Built-in
  • Speed frequency response: 550 Hz or more
  • Protective functions: Overcurrent shutdown, regeneration overvoltage shutdown, overload shutdown (electronic thermal), servomotor overheat protection, encoder fault protection, regeneration fault protection, undervoltage/sudden power outage protection,overspeed protection, excess error protection
  • Structure: Self-cooling, open (IP00)
  • Ambient temperature: Operation:0-55°C (no freezing), Storage: -20-65°C (no freezing)
  • Ambient humidity: Operation:90% RH max. (no condensation), Storage:90% RH max. (no condensation) 
  • Atmosphere: Inside control panel; no corrossive gas, no flammable gas, no oil mist, no dust
  • Elevation: 1000m or less above sea level
  • oscillation: 5.9 m/s max.
  • Shipping Weight: 2.5 Kg

MITSUBISHI MR-J2S-70A



  • Power Supply (Voltage/frequency): 3-phase 200-230VAC, 50/60Hz; 1-phase 230VAC, 50/60Hz
  • Power Supply (Permissible voltage fluctuation): 3-phase 200-230VAC, 170-253VAC 

  • Power Supply (Permissible frequency fluctuation): ±5%
  • Control System: Sinusoidal PWM control/current control system
  • Dynamic brake: Built-in
  • Speed frequency response: 550 Hz or more
  • Protective functions: Overcurrent shutdown, regeneration overvoltage shutdown, overload shutdown (electronic thermal), servomotor overheat protection, encoder fault protection, regeneration fault protection, undervoltage/sudden power outage protection,overspeed protection, excess error protection
  • Maximum input pulse frequency (Position control mode): 500 kpps- when using differential receiver, 200 kpps- when using open collector
  • Positioning feedback pulse (Position control mode): Resolution per encoder/servo motor rotation (131072 pulse/revolution)
  • Positioning complete width setting (Position control mode): 0 - ±10VDC
  • Excess error (Position control mode): ±10 rotations
  • Torque limit input (Position control mode): Set by parameters or external analog input (0-±10VDC / maximum torque)
  • Speed control range (Speed control mode): Analog speed command 1:2000, internal speed command 1:5000
  • Analog speed command input (Speed control mode): 0-±10VDC / rated speed
  • Speed fluctuation rate (Speed control mode): ±0.01% max.(load fluctuation 0-100%), 0% (power fluctuation ±10%), ±0.2% max. (ambient temperature 25°C ± 10°C), when using external analog speed command
  • Torque limit (Speed control mode): Set by parameters or external analog input (0-±10VDC / maximum torque)
  • Torque command input (Torque control specifications): 0-±8VDC / maximum torque (input impedance 10 to 12kΩ)
  • Speed limit (Torque control specifications): Set by parameters or external analog input (0-±10VDC, rated speed)
  • Structure: Self-cooling, open (IP00) 
  • Shipping Weight: 3 kg

MITSUBISHI MR-J2S-100A




  • Power Supply (Voltage/frequency): 3-phase 200-230VAC, 50/60Hz
  • Power Supply (Permissible voltage fluctuation): 3-phase 170-253VAC
  • Power Supply (Permissible frequency fluctuation): ±5%
  • Control System: Sinusoidal PWM control/current control system
  • Dynamic brake: Built-in
  • Speed frequency response: 550 Hz or more
  • Protective functions: Overcurrent shutdown, regeneration overvoltage shutdown, overload shutdown (electronic thermal), servomotor overheat protection, encoder fault protection, regeneration fault protection, undervoltage/sudden power outage protection,overspeed protection, excess error protection
  • Maximum input pulse frequency (Position control mode): 500 kpps- when using differential receiver, 200 kpps- when using open collector
  • Positioning feedback pulse (Position control mode): Resolution per encoder/servo motor rotation (131072 pulse/revolution)
  • Positioning complete width setting (Position control mode): 0 - ±10VDC
  • Excess error (Position control mode): ±10 rotations
  • Torque limit input (Position control mode): Set by parameters or external analog input (0-±10VDC / maximum torque)
  • Speed control range (Speed control mode): Analog speed command 1:2000, internal speed command 1:5000
  • Analog speed command input (Speed control mode): 0-±10VDC / rated speed
  • Speed fluctuation rate (Speed control mode): ±0.01% max.(load fluctuation 0-100%), 0% (power fluctuation ±10%), ±0.2% max. (ambient temperature 25°C ± 10°C), when using external analog speed command
  • Torque limit (Speed control mode): Set by parameters or external analog input (0-±10VDC / maximum torque)
  • Torque command input (Torque control specifications): 0-±8VDC / maximum torque (input impedance 10 to 12kΩ)
  • Speed limit (Torque control specifications): Set by parameters or external analog input (0-±10VDC, rated speed)
  • Structure: Self-cooling, open (IP00) 
  • Shipping Weight: 3 Kg

MITSUBISHI MR-J2S-40A



  • Power Supply (Voltage/frequency): 3-phase 200-230VAC, 50/60Hz; 1-phase 230VAC, 50/60Hz
  • Power Supply (Permissible voltage fluctuation): 3-phase 200-230VAC, 170-253VAC 

  • Power Supply (Permissible frequency fluctuation): ±5%
  • Control System: Sinusoidal PWM control/current control system
  • Dynamic brake: Built-in
  • Speed frequency response: 550 Hz or more
  • Protective functions: Overcurrent shutdown, regeneration overvoltage shutdown, overload shutdown (electronic thermal), servomotor overheat protection, encoder fault protection, regeneration fault protection, undervoltage/sudden power outage protection,overspeed protection, excess error protection
  • Maximum input pulse frequency (Position control mode): 500 kpps- when using differential receiver, 200 kpps- when using open collector
  • Positioning feedback pulse (Position control mode): Resolution per encoder/servo motor rotation (131072 pulse/revolution)
  • Positioning complete width setting (Position control mode): 0 - ±10VDC
  • Excess error (Position control mode): ±10 rotations
  • Torque limit input (Position control mode): Set by parameters or external analog input (0-±10VDC / maximum torque)
  • Speed control range (Speed control mode): Analog speed command 1:2000, internal speed command 1:5000
  • Analog speed command input (Speed control mode): 0-±10VDC / rated speed
  • Speed fluctuation rate (Speed control mode): ±0.01% max.(load fluctuation 0-100%), 0% (power fluctuation ±10%), ±0.2% max. (ambient temperature 25°C ± 10°C), when using external analog speed command
  • Torque limit (Speed control mode): Set by parameters or external analog input (0-±10VDC / maximum torque)
  • Torque command input (Torque control specifications): 0-±8VDC / maximum torque (input impedance 10 to 12kΩ)
  • Speed limit (Torque control specifications): Set by parameters or external analog input (0-±10VDC, rated speed)
  • Structure: Self-cooling, open (IP00) 
  • Shipping Weight: 3 Kg

MITSUBISHI MR-J2S-700A




  • Power Supply (Voltage/frequency): 3-phase 200-230VAC, 50/60Hz
  • Power Supply (Permissible voltage fluctuation): 3-phase 170-253VAC
  • Power Supply (Permissible frequency fluctuation): ±5%
  • Control System: Sinusoidal PWM control/current control system
  • Dynamic brake: Built-in
  • Speed frequency response: 550 Hz or more
  • Protective functions: Overcurrent shutdown, regeneration overvoltage shutdown, overload shutdown (electronic thermal), servomotor overheat protection, encoder fault protection, regeneration fault protection, undervoltage/sudden power outage protection,overspeed protection, excess error protection
  • Maximum input pulse frequency (Position control mode): 500 kpps- when using differential receiver, 200 kpps- when using open collector
  • Positioning feedback pulse (Position control mode): Resolution per encoder/servo motor rotation (131072 pulse/revolution)
  • Positioning complete width setting (Position control mode): 0 - ±10VDC
  • Excess error (Position control mode): ±10 rotations
  • Torque limit input (Position control mode): Set by parameters or external analog input (0-±10VDC / maximum torque)
  • Speed control range (Speed control mode): Analog speed command 1:2000, internal speed command 1:5000
  • Analog speed command input (Speed control mode): 0-±10VDC / rated speed
  • Speed fluctuation rate (Speed control mode): ±0.01% max.(load fluctuation 0-100%), 0% (power fluctuation ±10%), ±0.2% max. (ambient temperature 25°C ± 10°C), when using external analog speed command
  • Torque limit (Speed control mode): Set by parameters or external analog input (0-±10VDC / maximum torque)
  • Torque command input (Torque control specifications): 0-±8VDC / maximum torque (input impedance 10 to 12kΩ)
  • Speed limit (Torque control specifications): Set by parameters or external analog input (0-±10VDC, rated speed)
  • Structure: Fan-cooling, open (IP00) 
  • Shipping Weight: 8.6 kg

MITSUBISHI MR-J2S-500B



  • Power Supply (Voltage/frequency): 3-phase 200-230VAC, 50/60Hz
  • Power Supply (Permissible voltage fluctuation): 3-phase 170-253VAC
  • Power Supply (Permissible frequency fluctuation): ±5%
  • Control System: Sinusoidal PWM control/current control system
  • Dynamic brake: Built-in
  • Speed frequency response: 550 Hz or more
  • Protective functions: Overcurrent shutdown, regeneration overvoltage shutdown, overload shutdown (electronic thermal), servomotor overheat protection, encoder fault protection, regeneration fault protection, undervoltage/sudden power outage protection,overspeed protection, excess error protection
  • Structure: Fan-cooling, open (IP00)
  • Ambient temperature: Operation:0-55°C (no freezing), Storage: -20-65°C (no freezing)
  • Ambient humidity: Operation:90% RH max. (no condensation), Storage:90% RH max. (no condensation) 
  • Atmosphere: Inside control panel; no corrossive gas, no flammable gas, no oil mist, no dust
  • Elevation: 1000m or less above sea level
  • Oscillation: 5.9 m/s max.
  • Shipping Weight: 6.1 kg

MITSUBISHI MR-J2S-500A



  • Power Supply (Voltage/frequency): 3-phase 200-230VAC, 50/60Hz
  • Power Supply (Permissible voltage fluctuation): 3-phase 170-253VAC
  • Power Supply (Permissible frequency fluctuation): ±5%
  • Control System: Sinusoidal PWM control/current control system
  • Dynamic brake: Built-in
  • Speed frequency response: 550 Hz or more
  • Protective functions: Overcurrent shutdown, regeneration overvoltage shutdown, overload shutdown (electronic thermal), servomotor overheat protection, encoder fault protection, regeneration fault protection, undervoltage/sudden power outage protection,overspeed protection, excess error protection
  • Maximum input pulse frequency (Position control mode): 500 kpps- when using differential receiver, 200 kpps- when using open collector
  • Positioning feedback pulse (Position control mode): Resolution per encoder/servo motor rotation (131072 pulse/revolution)
  • Positioning complete width setting (Position control mode): 0 - ±10VDC
  • Excess error (Position control mode): ±10 rotations
  • Torque limit input (Position control mode): Set by parameters or external analog input (0-±10VDC / maximum torque)
  • Speed control range (Speed control mode): Analog speed command 1:2000, internal speed command 1:5000
  • Analog speed command input (Speed control mode): 0-±10VDC / rated speed
  • Speed fluctuation rate (Speed control mode): ±0.01% max.(load fluctuation 0-100%), 0% (power fluctuation ±10%), ±0.2% max. (ambient temperature 25°C ± 10°C), when using external analog speed command
  • Torque limit (Speed control mode): Set by parameters or external analog input (0-±10VDC / maximum torque)
  • Torque command input (Torque control specifications): 0-±8VDC / maximum torque (input impedance 10 to 12kΩ)
  • Speed limit (Torque control specifications): Set by parameters or external analog input (0-±10VDC, rated speed)
  • Structure: Fan-cooling, open (IP00) 
  • Shipping Weight: 6 kg

MITSUBISHI MR-J2S-350B




  • Power Supply (Voltage/frequency): 3-phase 200-230VAC, 50/60Hz
  • Power Supply (Permissible voltage fluctuation): 3-phase 170-253VAC
  • Power Supply (Permissible frequency fluctuation): ±5%
  • Control System: Sinusoidal PWM control/current control system
  • Dynamic brake: Built-in
  • Speed frequency response: 550 Hz or more
  • Protective functions: Overcurrent shutdown, regeneration overvoltage shutdown, overload shutdown (electronic thermal), servomotor overheat protection, encoder fault protection, regeneration fault protection, undervoltage/sudden power outage protection,overspeed protection, excess error protection
  • Structure: Fan-cooling, open (IP00)
  • Ambient temperature: Operation:0-55°C (no freezing), Storage: -20-65°C (no freezing)
  • Ambient humidity: Operation:90% RH max. (no condensation), Storage:90% RH max. (no condensation) 
  • Atmosphere: Inside control panel; no corrossive gas, no flammable gas, no oil mist, no dust
  • Elevation: 1000m or less above sea level
  • oscillation: 5.9 m/s max.
  • Shipping Weight: 2.5 kg

MITSUBISHI MR-J2S-200B




  • Power Supply (Voltage/frequency): 3-phase 200-230VAC, 50/60Hz
  • Power Supply (Permissible voltage fluctuation): 3-phase 170-253VAC
  • Power Supply (Permissible frequency fluctuation): ±5%
  • Control System: Sinusoidal PWM control/current control system
  • Dynamic brake: Built-in
  • Speed frequency response: 550 Hz or more
  • Protective functions: Overcurrent shutdown, regeneration overvoltage shutdown, overload shutdown (electronic thermal), servomotor overheat protection, encoder fault protection, regeneration fault protection, undervoltage/sudden power outage protection,overspeed protection, excess error protection
  • Structure: Fan-cooling, open (IP00)
  • Ambient temperature: Operation:0-55°C (no freezing), Storage: -20-65°C (no freezing)
  • Ambient humidity: Operation:90% RH max. (no condensation), Storage:90% RH max. (no condensation) 
  • Atmosphere: Inside control panel; no corrossive gas, no flammable gas, no oil mist, no dust
  • Elevation: 1000m or less above sea level
  • oscillation: 5.9 m/s max.
  • Shipping Weight: 2.5 kg

MITSUBISHI MR-J2S-70B




  • Power Supply (Voltage/frequency): 3-phase 200-230VAC, 50/60Hz; 1-phase 230VAC, 50/60Hz
  • Power Supply (Permissible voltage fluctuation): 3-phase 200-230VAC, 170-253VAC 

  • Power Supply (Permissible frequency fluctuation): ±5%
  • Control System: Sinusoidal PWM control/current control system
  • Dynamic brake: Built-in
  • Speed frequency response: 550 Hz or more
  • Protective functions: Overcurrent shutdown, regeneration overvoltage shutdown, overload shutdown (electronic thermal), servomotor overheat protection, encoder fault protection, regeneration fault protection, undervoltage/sudden power outage protection,overspeed protection, excess error protection
  • Maximum input pulse frequency (Position control mode): 500 kpps- when using differential receiver, 200 kpps- when using open collector
  • Positioning feedback pulse (Position control mode): Resolution per encoder/servo motor rotation (131072 pulse/revolution)
  • Positioning complete width setting (Position control mode): 0 - ±10VDC
  • Excess error (Position control mode): ±10 rotations
  • Torque limit input (Position control mode): Set by parameters or external analog input (0-±10VDC / maximum torque)
  • Speed control range (Speed control mode): Analog speed command 1:2000, internal speed command 1:5000
  • Analog speed command input (Speed control mode): 0-±10VDC / rated speed
  • Speed fluctuation rate (Speed control mode): ±0.01% max.(load fluctuation 0-100%), 0% (power fluctuation ±10%), ±0.2% max. (ambient temperature 25°C ± 10°C), when using external analog speed command
  • Torque limit (Speed control mode): Set by parameters or external analog input (0-±10VDC / maximum torque)
  • Torque command input (Torque control specifications): 0-±8VDC / maximum torque (input impedance 10 to 12kΩ)
  • Speed limit (Torque control specifications): Set by parameters or external analog input (0-±10VDC, rated speed)
  • Structure: Self-cooling, open (IP00) 
  • Shipping Weight: 3 kg

MITSUBISHI MR-J2S-40B



  • Power Supply (Voltage/frequency): 3-phase 200-230VAC, 50/60Hz; 1-phase 230VAC, 50/60Hz
  • Power Supply (Permissible voltage fluctuation): 3-phase 200-230VAC, 170-253VAC
  • Power Supply (Permissible frequency fluctuation): ±5%
  • Control System: Sinusoidal PWM control/current control system
  • Dynamic brake: Built-in
  • Speed frequency response: 550 Hz or more
  • Protective functions: Overcurrent shutdown, regeneration overvoltage shutdown, overload shutdown (electronic thermal), servomotor overheat protection, encoder fault protection, regeneration fault protection, undervoltage/sudden power outage protection,overspeed protection, excess error protection
  • Structure: Self-cooling, open (IP00)
  • Ambient temperature: Operation: 0-55°C (no freezing), Storage: -20-65°C (no freezing)
  • Ambient humidity: Operation: 90% RH max. (no condensation), Storage:90% RH max. (no condensation) 
  • Atmosphere: Inside control panel; no corrossive gas, no flammable gas, no oil mist, no dust
  • Elevation: 1000m or less above sea level
  • Oscillation: 5.9 m/s max.
  • Shipping Weight: 2.1 kg

MITSUBISHI MR-J2S-20B






Mitsubishi servo motor and amplifier MR-J2S-20B (New Original) in Stock


Mitsubishi general ac servo amplifier series is J2S - MR in MR - J2 series on the basis of the development of higher performance and higher functions of servo system, ac servo amplifier MR - J2S series is the control mode, speed control and the position control torque control and switch control ways to choose the servo amplifier is widely used in mechanical, not only can work with general industrial machinery and high precision and stable position control of speed control, can also be used to speed control and tension control field, the products have RS - 232 and RS - 422 serial communication function, through the installation has set the personal computer software server can be to set parameters, commissioning, state display and gain adjustment with ac servo amplifiers, MR J2S - the servo motor encoder supporting series adopts resolution for 131072 pulse/turn the encoder, so than ac servo amplifier series on J2S - with MR higher accuracy control ability, using high-performance CPU, greatly improving product response speed loop frequency response to various series of 550HZ, servo motor control and motor ADAPTS to different needs of ABS mode, supported encoder in servo amplifier, the battery can be added, use of absolute position system is more convenient, excellent mechanical properties, the automatic resonance, can easily analysis function of mechanical vibration suppression, gain search function, can automatically identify the best gain value

MITSUBISHI HG-SR352J



Mitsubishi Servo Motor HG-SR352J MR-JE Series 3-phase 200 VAC to 240 VAC
Combinations of Servo Amplifier and Servo Motor
AmplifierServo MotorStocked Item
HG-KN SeriesHG-SN Series
MR-JE-10B/MR-JE-10AHG-KN13J-S
MR-JE-20B/MR-JE-20AHG-KN23J-S
MR-JE-40B/MR-JE-40AHG-KN43J-S
MR-JE-70B/MR-JE-70AHG-KN73JHG-SN52JS
MR-JE-100B/MR-JE-100A-HG-SN102JS
MR-JE-200B/MR-JE-200A-HG-SN152J
HG-SN202J
S
MR-JE-300B/MR-JE-300A-HG-SN302JS

Servo Amplifier Model MR-JE-10A20A40A70A100A200A300A
Stocked ItemSSSSSSS
OutputRated Voltage3-phase 170 VAC
Rated Current (A)1.11.52.85.86.011.011.0
Power Supply InputVoltage/Frequency (*1)3-phase or 1-phase 200 VAC to 240 VAC, 50 Hz/60 Hz3-phase 200 VAC to 240 VAC, 50 Hz/60 Hz
Rated Current (A) (*7)0.91.52.63.85.010.514.0
Permissible Voltage Fluctuation3-phase or 1-phase 170 VAC to 264 VAC3-phase 170 VAC to 264 VAC
Permissible Frequency Fluctuation±5% maximum
Interface Power Supply24 V DC ± 10% (required current capacity: 0.3 A)
Control MethodSine-wave PWM control/current control method
Tolerable Regenerative Power of the Built-In Regenerative Resistor (W) (*2, 3)--102020100100
Dynamic BrakeBuilt-in (*4)
Communication FunctionUSB: Connect a personal computer (MR Configurator2 compatible)
RS-422: Connect a controller (1:n communication up to 32 axes) (*6)
Encoder Output PulseCompatible (A/B/Z-phase pulse)
Analog Monitor2 channels
Position Control ModeMaximum Input Pulse Frequency4 Mpulses/s (when using differential receiver), 200 kpulses/s (when using open-collector)
Positioning Feedback PulseEncoder resolution: 131072 pulses/rev
Command Pulse Multiplying FactorElectronic gear A/B multiple, A: 1 to 16777215, B: 1 to 16777215, 1/10 < A/B
< 4000
Positioning Complete Width Setting0 pulse to ±65535 pulses (command pulse unit)
Error Excessive±3 rotations
Torque LimitSet by parameters or external analog input (0 V DC to +10 V DC/maximum torque)
Speed Control ModeSpeed Control RangeAnalog speed command 1:2000, internal speed command 1:5000
Analog Speed Command Input0 V DC to ±10 VDC/rated speed (Speed at 10 V is changeable with [Pr. PC12].)
Speed Fluctuation Rate±0.01% maximum (load fluctuation 0% to 100%), 0% (power fluctuation: ±10%)
±0.2% maximum (ambient temperature: 25 °C ± 10 °C) only when using analog speed command
Torque LimitSet by parameters or external analog input (0 V DC to +10 V DC/maximum torque)
Torque Control ModeAnalog Torque Command Input0 VDC to ±8 VDC/maximum torque (input impedance: 10 kΩ to 12 kΩ)
Speed LimitSet by parameters or external analog input (0 V DC to ± 10 V DC/rated speed)
Servo FunctionAdvanced vibration suppression control II, adaptive filter II, robust filter, auto tuning, one-touch tuning, tough drive function, drive recorder function, machine diagnosis function, power monitoring function, lost motion compensation function.
Protective FunctionsOvercurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal), servo motor overheat protection, encoder error protection, regenerative error protection, undervoltage protection, instantaneous power failure protection,
overspeed protection, error excessive protection
Compliance to StandardsEN 61800-3, EN 61800-5-1, RoHS compliant, UL: UL 508C, KC compliant
Structure (IP Rating)Natural cooling, open (IP20)Force cooling, open (IP20)
Close MountingPossible (*5)
EnvironmentAmbient Temperature0 °C to 55 °C (non-freezing), storage: -20 °C to 65 °C (non-freezing)
Ambient Humidity90 %RH maximum (non-condensing), storage: 90 %RH maximum (non-condensing)
AmbienceIndoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust
Altitude1000 m or less above sea level
Vibration Resistance5.9 m/s² at 10 Hz to 55 Hz (directions of X, Y and Z axes)
Weight (kg)0.80.80.81.51.52.12.1

MITSUBISHI HF-SN202J-S100



Mitsubishi Servo Motor HF-SN202J-S100 MR-JE Series 3-phase 200 VAC to 240 VAC
Combinations of Servo Amplifier and Servo Motor
AmplifierServo MotorStocked Item
HG-KN SeriesHG-SN Series
MR-JE-10B/MR-JE-10AHG-KN13J-S
MR-JE-20B/MR-JE-20AHG-KN23J-S
MR-JE-40B/MR-JE-40AHG-KN43J-S
MR-JE-70B/MR-JE-70AHG-KN73JHG-SN52JS
MR-JE-100B/MR-JE-100A-HG-SN102JS
MR-JE-200B/MR-JE-200A-HG-SN152J
HG-SN202J
S
MR-JE-300B/MR-JE-300A-HG-SN302JS

Servo Amplifier Model MR-JE-10A20A40A70A100A200A300A
Stocked ItemSSSSSSS
OutputRated Voltage3-phase 170 VAC
Rated Current (A)1.11.52.85.86.011.011.0
Power Supply InputVoltage/Frequency (*1)3-phase or 1-phase 200 VAC to 240 VAC, 50 Hz/60 Hz3-phase 200 VAC to 240 VAC, 50 Hz/60 Hz
Rated Current (A) (*7)0.91.52.63.85.010.514.0
Permissible Voltage Fluctuation3-phase or 1-phase 170 VAC to 264 VAC3-phase 170 VAC to 264 VAC
Permissible Frequency Fluctuation±5% maximum
Interface Power Supply24 V DC ± 10% (required current capacity: 0.3 A)
Control MethodSine-wave PWM control/current control method
Tolerable Regenerative Power of the Built-In Regenerative Resistor (W) (*2, 3)--102020100100
Dynamic BrakeBuilt-in (*4)
Communication FunctionUSB: Connect a personal computer (MR Configurator2 compatible)
RS-422: Connect a controller (1:n communication up to 32 axes) (*6)
Encoder Output PulseCompatible (A/B/Z-phase pulse)
Analog Monitor2 channels
Position Control ModeMaximum Input Pulse Frequency4 Mpulses/s (when using differential receiver), 200 kpulses/s (when using open-collector)
Positioning Feedback PulseEncoder resolution: 131072 pulses/rev
Command Pulse Multiplying FactorElectronic gear A/B multiple, A: 1 to 16777215, B: 1 to 16777215, 1/10 < A/B
< 4000
Positioning Complete Width Setting0 pulse to ±65535 pulses (command pulse unit)
Error Excessive±3 rotations
Torque LimitSet by parameters or external analog input (0 V DC to +10 V DC/maximum torque)
Speed Control ModeSpeed Control RangeAnalog speed command 1:2000, internal speed command 1:5000
Analog Speed Command Input0 V DC to ±10 VDC/rated speed (Speed at 10 V is changeable with [Pr. PC12].)
Speed Fluctuation Rate±0.01% maximum (load fluctuation 0% to 100%), 0% (power fluctuation: ±10%)
±0.2% maximum (ambient temperature: 25 °C ± 10 °C) only when using analog speed command
Torque LimitSet by parameters or external analog input (0 V DC to +10 V DC/maximum torque)
Torque Control ModeAnalog Torque Command Input0 VDC to ±8 VDC/maximum torque (input impedance: 10 kΩ to 12 kΩ)
Speed LimitSet by parameters or external analog input (0 V DC to ± 10 V DC/rated speed)
Servo FunctionAdvanced vibration suppression control II, adaptive filter II, robust filter, auto tuning, one-touch tuning, tough drive function, drive recorder function, machine diagnosis function, power monitoring function, lost motion compensation function.
Protective FunctionsOvercurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal), servo motor overheat protection, encoder error protection, regenerative error protection, undervoltage protection, instantaneous power failure protection,
overspeed protection, error excessive protection
Compliance to StandardsEN 61800-3, EN 61800-5-1, RoHS compliant, UL: UL 508C, KC compliant
Structure (IP Rating)Natural cooling, open (IP20)Force cooling, open (IP20)
Close MountingPossible (*5)
EnvironmentAmbient Temperature0 °C to 55 °C (non-freezing), storage: -20 °C to 65 °C (non-freezing)
Ambient Humidity90 %RH maximum (non-condensing), storage: 90 %RH maximum (non-condensing)
AmbienceIndoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust
Altitude1000 m or less above sea level
Vibration Resistance5.9 m/s² at 10 Hz to 55 Hz (directions of X, Y and Z axes)
Weight (kg)0.80.80.81.51.52.12.1