Brand: MITSUBISHI
Name: Open collector output
Model: QD75P1
1 axes, open collector output type.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis.
Maximum pulse output: 200Kpps.
40 pin connector.
Positioning module.
Open collector output.
Differential driver output.
Based on the use of open collector outputs and differential drive output type 2 types.
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control.
(the command pulse of the open collector positioning module is highest 200kpps.)
Input / output points: 4096 points.
Number of input and output elements: 8192.
Program capacity: 100 K step.
Processing speed: 0.0095 s.
Program memory capacity: 400 KB.
Support USB and RS232.
Support installed memory card.
Providing high speed communication between multiple CPU.
High speed and high precision data processing MITSUBISHI QD75P1.
The processing speed of the real number (floating point) arithmetic has been greatly improved,
Addition instruction reached 0 QD75P1 014 mu s,
Therefore, it can support the request of high-speed, high-precision processing data processing.
In addition, the new addition of double precision floating point arithmetic instructions,
Simplify the programming, reduces the computational error when executing complex formula MITSUBISHI QD75P1.
Shorten the fixed scan interrupt time, high precision device.
The minimum interval of the fixed period interrupt program is reduced to 100 s.
The high speed signal can be accurately obtained, which makes the contribution to the higher precision of the device.5 slots.
Requires 1 power modules.
Used to install large Q series modules.
Reduce system downtime recovery time MITSUBISHI QD75P1.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance MITSUBISHI Open collector output.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown MITSUBISHI Open collector output.
Wider application range, more advanced.
Leading in the era of the Q series CPU products.
Q series CPU products a wide range of applications,
Provide programmable controller, process, redundancy, C language, movement, manipulator, CNC all kinds of CPU,
In order to meet the needs of various control MITSUBISHI Open collector output.
Through the multi CPU configuration, can be based on the use of the scale, purpose,
Construction of the best system to meet the requirements of all kinds of control.
In addition, the high reliability system can be constructed by the redundant system,
Even if a fault occurs, the system can continue to run.Input / output points: 4096 points.
You can use the CF card.
Version OS:VxWorks 5.4.
Automatically transfer the record file to the FTP server,
Simply by recording the configuration tool to carry out a simple setup,
A data record file stored on the SD memory card can be sent to the FTP server.
Because the record server can handle multiple files, it can reduce the task of management and maintenance.
When a failure occurs, it can quickly respond to.
Simply extract the data associated with the problem, do not have to spend a lot of time to filter a large number of diagnostic data,
So it can quickly deterrmine the cause of the failure, and make the solution QD75P1.
Simply insert the SD memory card, you can automatically record.
Simply insert the SD in the CPU to save the record setting file, you can automatically start recording.
Even wheen remote data collection is required,
After receiving a record setting file by mail and copy it to the SD memory card,
Can immediately start recording MITSUBISHI QD75P1.