FX3G-422-BD


Spesifications

  • Manufacturer: Mitsubishi Electric 
  • FX3G-422-BD 
  • RS-422 communication function expansion board FX3G-422-BD 
  • Transmission standard : It conforms to the RS-422 standard 
  • Insulation method : Non-insulated (between the communication line and the CPU) 
  • Transmission distance : Up to 50m 
  • External device connection method : MINI DIN 8pin (female) 
  • Communication system : Half-duplex bi-directional 
  • Communication procedure : Programming communication 
  • communication speed : 9600/19200/38400/57600/115200 (bps) 
  • O occupied points : 0 points (no relation to the maximum input and output points of the sequencer) 
  • Apply sequencer : FX3S, FX3G
    FX3S when connected, can not be used in conjunction function expansion board and FX3S-CNV-ADP. 
  • Ambient temperature : 0 ~ 55 °C ····· operation, -25 ~ 75 °C ····· during storage 
  • Relative humidity : 5 ~ 95% RH (non-condensing) ...... operation 
  • Vibration resistance When the DIN rail mounting Frequency: 10 ~ 57Hz : Half amplitude: 0.035mm X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Frequency: 57 ~ 150Hz : Acceleration: 4.9m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Direct mounting at the time Frequency: 10 ~ 57Hz : Half amplitude: 0.075mm X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Frequency: 57 ~ 150Hz : Acceleration: 9.8m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Impact : 147m / s2, duration of action 11ms, X at half-sine pulse, Y, Z directions 3 times each 
  • Anti-noise : Noise voltage 1,000Vp-p, noise width 1μs, due to rising 1ns, cycle 30 ~ 100Hz of noise simulator 
  • Withstand voltage : Non-isolated between communication line and the PLC main unit
    (Please do not withstand voltage test) 
  • Insulation resistance : Non-isolated between communication line and the PLC main unit
    (Please do not insulation resistance test) 
  • Use atmosphere : Corrosive, there is no flammable gas, conductive dust (dust) that is not terribly 
  • Advanced use : 2,000m or less
    can not be used under the pressurized environment to more than atmospheric pressure. There is a possibility of failure. 
  • Shipping Weight : 1 Kg