Spesifications
- Manufacturer: Mitsubishi Electric
- RS-232C for communication special adapter (MODBUS corresponding) FX3U-232ADP-MB
- Transmission standard : RS-232C compliant
- Insulation method : Photocoupler
- Transmission distance : Up to 15m
- External device connection method : D-SUB 9Pin connector (male)
- Communication system : Full-duplex bi-directional
- Communication procedure : · MODBUS communication (master or slave) - No-protocol communication , computer link (dedicated protocol format 1, dedicated protocol format 4) programming communication
- communication speed MODBUS communication : 300/600/1200/2400/4800/9600/19200/38400/57600/115200 (bps) corresponds to 38400/57600 / 115200bps from products manufactured on or after July 2012. (Serial number: 127 **** or later)
- No-protocol communication, computer link : 300/600/1200/2400/4800/9600/19200/38400 (Bps) FX3U, FX3UC is, later Ver.2.41, it supports 38400bps.
- Programming communication : 9600/19200/38400/57600/115200 (bps)
- Display (LED) : RD, SD, POWER
- O occupied points : 0 points (no relation to the maximum input and output points of the sequencer)
- Apply sequencer : [FX3S]
V1.00 and later: corresponding to all the communication function
[FX3G]
V1.00 and later: communication functions other than the MODBUS communication to the corresponding
V1.30 and later: corresponds to the MODBUS communication function
[FX3U]
V2.20 and later: other than MODBUS communication communication function to the corresponding of
V2.40 and later: corresponds to the MODBUS communication function
[FX3GC]
V1.40 and later: corresponding to all the communication function
[FX3UC]
V1.00 and later: corresponds to the communication functions other than the MODBUS communication
V2.40 and later: MODBUS corresponding to the communication function - connection to FX3S is required FX3S-CNV-ADP.
Connection to the FX3G is required FX3G-CNV-ADP.
FX3U, connection to the FX3UC-32MT-LT (-2), you must have the function expansion board. - mass : 0.08kg
- Power Specifications :
- Power supply : DC5V 30mA (internal power supply from the sequencer)
- Ambient temperature : 0 ~ 55 °C ····· operation, -25 ~ 75 °C ····· during storage
- Relative humidity : 5 ~ 95% RH (non-condensing) ...... operation
- Vibration resistance When the DIN rail mounting Frequency: 10 ~ 57Hz Half amplitude: 0.035mm X, Y, Z each direction 10 times (for a total of each 80 minutes)
- Frequency: 57 ~ 150Hz Acceleration: 4.9m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes)
- Direct mounting at the time Frequency: 10 ~ 57Hz Half amplitude: 0.075mm X, Y, Z each direction 10 times (for a total of each 80 minutes)
- Frequency: 57 ~ 150Hz Acceleration: 9.8m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes)
- Impact : 147m / s2, duration of action 11ms, X at half-sine pulse, Y, Z directions 3 times each
- Anti-noise : Noise voltage 1,000Vp-p, noise width 1μs, due to rising 1ns, cycle 30 ~ 100Hz of noise simulator
- Withstand voltage : D-SUB 9Pin connector and between the ground terminal of the basic unit: AC500V 1 minute
- Insulation resistance : D-SUB 9Pin connector and between the ground terminal of the basic unit: DC500V 5MΩ more in insulation resistance tester
- Use atmosphere : Corrosive, there is no flammable gas, conductive dust (dust) that is not terribly
- Advanced use : 2000m or less
can not be used in the pressurized environment to more than atmospheric pressure. There is a possibility of failure. - Shipping Weight: 1 Kg
Tidak ada komentar:
Posting Komentar