Spesifications

  • Manufacturer: Mitsubishi Electric 
  • FX3U-485ADP-MB
  • Transmission standard: RS-485 standard, conform to the RS-422 standard 
  • Insulation method:Photocoupler 
  • Transmission distance: The total length 500m or less
    (to the equipment to be connected FX2N-485-BD, FX1N- 485-BD, FX3U-485-BD, following the total length 50m if it contains a FX3G-485-BD) 
  • External device connection method: Europe terminal block 
  • Communication system: Half-duplex bi-directional 
  • Communication procedure: . MODBUS (master or slave) - No-protocol communication, computer link (dedicated protocol format 1, dedicated protocol format 4), parallel link and simple PC-to-PC link inverter communication 
  • communication speed MODBUS communication: 300/600/1200/2400/4800/9600/19200/38400/57600/115200 (bps)
    corresponds to 38400/57600 / 115200bps from products manufactured on or after July 2012. (Serial number: 127 **** or later) 
  • No-protocol, the computer link: 300/600/1200/2400/4800/9600/19200/38400 (Bps)
    FX3U, FX3UC is, later Ver.2.41, it supports 38400bps. 
  • Parallel link: 115200 (bps) 
  • Simple PC-to-PC link: 38400 (bps) 
  • Inverter communication: 4800/9600/19200/38400 (Bps)
    FX3U, FX3UC is, later Ver.2.41, it supports 38400bps. 
  • Display (LED): RD, SD, POWER 
  • O occupied points: 0 points (no relation to the maximum input and output points of the sequencer) 
  • Apply sequencer: [FX3S]
    V1.00 and later: corresponding to all the communication function 
  • [FX3G]
    V1.00 and later: MODBUS, corresponding to the communication functions other than the inverter communication
    V1.10 and later: inverter communication function to the corresponding
    V1.30 and later: in MODBUS communication function correspondence 
  • [FX3U]
    V2.20 and later: communication functions other than the MODBUS communication to the corresponding
    V2.40 and later: corresponds to the MODBUS communication function 
  • [FX3GC]
    V1.40 and later: corresponding to all the communication function 
  • [FX3UC]
    V1.00 and later: MODBUS communication communication function to the corresponding non-
    V2.40 and later: corresponds to the MODBUS communication function.
  • connection to FX3S is required FX3S-CNV-ADP. 
  • Connection to the FX3G is required FX3G-CNV-ADP. 
  • FX3U, connection to the FX3UC-32MT-LT (-2), you must have the function expansion board. 
  • mass: 0.08kg 
  • Power Specifications: 
  • Power supply: DC5V 20mA (internal power supply from the sequencer) 
  • Ambient temperature: 0 ~ 55 °C ..... operation, -25 ~ 75 °C ..... during storage 
  • Relative humidity: 5 ~ 95% RH (non-condensing) ...... operation 
  • Vibration resistance When the DIN rail mounting : Frequency: 10 ~ 57Hz: Half amplitude: 0.035mm X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • When the DIN rail mounting : Frequency: 57 ~ 150Hz: Acceleration: 4.9m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Direct mounting at the time : Frequency: 10 ~ 57Hz: Half amplitude: 0.075mm X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Direct mounting at the time : Frequency: 57 ~ 150Hz: Acceleration: 9.8m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Impact: 147m / s2, duration of action 11ms, X at half-sine pulse, Y, Z directions 3 times each 
  • Anti-noise: Noise voltage 1,000Vp-p, noise width 1μs, due to rising 1ns, cycle 30 ~ 100Hz of noise simulator 
  • Withstand voltage: External terminals and between the PLC main unit of the ground terminal: AC500V 1 minute 
  • Insulation resistance: External terminals and between the PLC main unit of the ground terminal: DC500V 5MΩ more in insulation resistance tester 
  • Use atmosphere: Corrosive, there is no flammable gas, conductive dust (dust) that is not terribly 
  • Advanced use: 2000m or less can not be used in the pressurized environment to more than atmospheric pressure. 
  • There is a possibility of failure. 