Kontak Kami

KONTAK KAMI : Telpon : 02126071413 Hp/WhatsApp : 081212269831 Perwakilan Jakarta : Gedung LTC Glodok Lantai 1 Blok C30 No.31 Jl.Hayam Wuruk No.127 Jakarta , Indonesia

Jumat, 12 Juni 2020

PLC OMRON CP2E Reduced development time with function blocks (FBs) programming


Diverse range of functions for your machine

Efficient solution for a flexible production, traceability and monitoring of machine key assets, to respond to operational excellence.
Improved connectivity to networking and serial devices.
Reduced development time with function blocks (FBs) programming.
Battery-free operation increases robustness and reduces maintenance. The extended operating temperature range increase reliability for special applications.







CP2E-N-type/Network model
Number of
points
SpecificationsModel
Power
Supply
InputsOutputsOutput
type
Program
capacity
Data
memory
capacity
Current
consumption
5 VDC24 VDC
CPU Units with
14 points
3777_lu_2_1
100 to
240 VAC
8
points
6
points
Relay10K steps
(FB
capacity:
10K steps)
16K
words
0.15 A0.05 ACP2E-N14DR-A
Transistor
(sinking)
0.21 A0.02 ACP2E-N14DT-A
24 VDCRelay0.15 A0.05 ACP2E-N14DR-D
Transistor
(sinking)
0.21 A0.02 ACP2E-N14DT-D
Transistor
(sourcing)
0.22 A0.02 ACP2E-N14DT1-D
CPU Units with
20 points
3777_lu_2_2
100 to
240 VAC
12
points
8
points
Relay0.17 A0.06 ACP2E-N20DR-A
Transistor
(sinking)
0.27 A0.02 ACP2E-N20DT-A
24 VDCRelay0.17 A0.06 ACP2E-N20DR-D
Transistor
(sinking)
0.27 A0.02 ACP2E-N20DT-D
Transistor
(sourcing)
0.26 A0.02 ACP2E-N20DT1-D
CPU Units with
30 points
3777_lu_2_3
100 to
240 VAC
18
points
12
points
Relay0.41 A0.07 ACP2E-N30DR-A
Transistor
(sinking)
0.52 A0.03 ACP2E-N30DT-A
24 VDCRelay0.37 A0.07 ACP2E-N30DR-D
Transistor
(sinking)
0.51 A0.03 ACP2E-N30DT-D
Transistor
(sourcing)
0.51 A0.03 ACP2E-N30DT1-D
CPU Units with
40 points
3777_lu_2_4
100 to
240 VAC
24
points
16
points
Relay0.39 A0.09 ACP2E-N40DR-A
Transistor
(sinking)
0.59 A0.03 ACP2E-N40DT-A
24 VDCRelay0.39 A0.09 ACP2E-N40DR-D
Transistor
(sinking)
0.59 A0.03 ACP2E-N40DT-D
Transistor
(sourcing)
0.59 A0.03 ACP2E-N40DT1-D
CPU Units with
60 points
3777_lu_2_5
100 to
240 VAC
36
points
24
points
Relay0.44 A0.13 ACP2E-N60DR-A
Transistor
(sinking)
0.71 A0.03 ACP2E-N60DT-A
24 VDCRelay0.41 A0.13 ACP2E-N60DR-D
Transistor
(sinking)
0.71 A0.03 ACP2E-N60DT-D
Transistor
(sourcing)
0.71 A0.03 ACP2E-N60DT1-D

CP2E-S-type/Standard model

Number of
points
SpecificationsModel
Power
Supply
InputsOutputsOutput
type
Program
capacity
Data
memory
capacity
Current
consumption
5 VDC24 VDC
CPU Units with
30 points
3777_lu_3_1
100 to
240 VAC
18
points
12
points
Relay8K steps
(FB
capacity:
8K steps)
8K words0.12 A0.07 ACP2E-S30DR-A
24 VDCTransistor
(sinking)
0.28 A0.02 ACP2E-S30DT-D
Transistor
(sourcing)
CP2E-S30DT1-D
CPU Units with
40 points
3777_lu_3_2
100 to
240 VAC
24
points
16
points
Relay0.13 A0.09 ACP2E-S40DR-A
24 VDCTransistor
(sinking)
0.34 A0.02 ACP2E-S40DT-D
Transistor
(sourcing)
CP2E-S40DT1-D
CPU Units with
60 points
3777_lu_3_3
100 to
240 VAC
36
points
24
points
Relay0.16 A0.13 ACP2E-S60DR-A
24 VDCTransistor
(sinking)
0.48 A0.02 ACP2E-S60DT-D
Transistor
(sourcing)
CP2E-S60DT1-D

CP2E-E-type/Essential model

Number of
points
SpecificationsModel
Power
Supply
InputsOutputsOutput
type
Program
capacity
Data
memory
capacity
Current
consumption
5 VDC24 VDC
CPU Units with
14 points
3777_lu_4_1
100 to
240 VAC
8 points6 pointsRelay4K steps
(FB
capacity:
4K steps)
4K words0.06 A0.04 ACP2E-E14DR-A
CPU Units with
20 points
3777_lu_4_2
12 points8 pointsRelay0.08 A0.06 ACP2E-E20DR-A
CPU Units with
30 points
3777_lu_4_3
18 points12 pointsRelay0.12 A0.07 ACP2E-E30DR-A
CPU Units with
40 points
3777_lu_4_4
24 points16 pointsRelay0.13 A0.09 ACP2E-E40DR-A
CPU Units with
60 points
3777_lu_4_5
36 points24 pointsRelay0.16 A0.13 ACP2E-E60DR-A

Optional Products

Battery

Product nameSpecificationsModel
Battery
3777_lu_5_1
Mounted in an N/S[][]-type CPU Unit.
Mount the Battery when using the clock function.
A Battery cannot be mounted to an E[][]-type CPU Unit.
CP2W-BAT02

Option Board

Product nameSpecificationsCurrent
consumption
Model
5 VDC24 VDC
RS-232C Option
Board
3777_lu_6_1
Mounted in the option slot of an N[][]-type CPU Unit and
can be used as an RS-232C port.
Maximum transmission distance: 15 m
0.04 A---CP1W-CIF01
Non-isolated
RS-422A/485
Option Board
3777_lu_6_2
Mounted in the option slot of an N[][]-type CPU Unit and
can be used as an RS-422A/485 port.
Maximum transmission distance: 50 m
0.04 A---CP1W-CIF11
Isolated
RS-422A/485
Option Board
3777_lu_6_3
Mounted in the option slot of an N[][]-type CPU Unit and
can be used as an RS-422A/485 port.
Maximum transmission distance: 500 m
0.04 A---CP1W-CIF12-V1
RS-232C&RS-232C
Option Board
3777_lu_6_4
Mounted in the option slot of an N[][]-type CPU Unit and
can be used as two RS-232C ports.
Maximum transmission distance: 15 m
0.04 A---CP2W-CIFD1
RS-232C&RS-485
Option Board
3777_lu_6_5
Mounted in the option slot of an N[][]-type CPU Unit and
can be used as one RS-232C port and one isolated
RS-485 port.
Maximum transmission distance:
15 m (RS-232C)
500 m (RS-485)
0.06 A---CP2W-CIFD2
RS-485&RS-485
Option Board
3777_lu_6_6
Mounted in the option slot of an N[][]-type CPU Unit and
can be used as two isolated RS-485 ports.
Maximum transmission distance: 500 m
0.08 A---CP2W-CIFD3
Analog Input Option
Board
3777_lu_6_7
Mounted in the option slot of an N[][]-type CPU Unit and
can be used as an analog input module.
• 2 analog inputs
0 to 10 V (Resolution: 1/4000)
0 to 20 mA (Resolution: 1/2000)
0.02 A---CP1W-ADB21
Analog Output
Option Board
3777_lu_6_8
Mounted in the option slot of an N[][]-type CPU Unit and
can be used as an analog output module.
• 2 analog outputs
0 to 10 V (Resolution: 1/4000)
0.06 A---CP1W-DAB21V
Analog Input/Output
Option Board
3777_lu_6_9
Mounted in the option slot of an N[][]-type CPU Unit and
can be used as an analog input/output module.
• 2 analog inputs
0 to 10 V (Resolution: 1/4000)
0 to 20 mA (Resolution: 1/2000)
• 2 analog outputs
0 to 10 V (Resolution: 1/4000)
0.08 A---CP1W-MAB221
Note: 1. Maximum one Analog Option Board can be mounted on an N[][]-type CPU Unit.
         2. The CP1W-ME05M Memory Cassette, CP1W-DAM01 LCD Option Board, and CP1W-CIF41 Ethernet Option Board
             cannot be used with the CP2E CPU Unit.
         3. Option Boards cannot be used with the E/S[][]-type CPU Unit.

Expansion I/O Units and Expansion Units (for E30/40/60, S30/40/60, or N30/40/60 CPU Units)

E14/20 or N14/20 CPU Units do not support Expansion I/O Units and Expansion Units.
Unit typeProduct
name
SpecificationsCurrent
consumption
(A)
Model
In-
puts
Out-
puts
Output type5 V24 V
CP1W
Expansion
I/O Units
Input Unit
3777_lu_7_1
8---24 VDC Input0.018---CP1W-8ED
Output Units
3777_lu_7_2
---8Relay0.0260.044CP1W-8ER
Transistor (sinking)0.075---CP1W-8ET
Transistor (sourcing)0.075---CP1W-8ET1
---16Relay0.0420.090CP1W-16ER
Transistor (sinking)0.076---CP1W-16ET
Transistor (sourcing)0.076---CP1W-16ET1
---32Relay0.0490.131CP1W-32ER
Transistor (sinking)0.113---CP1W-32ET
Transistor (sourcing)0.113---CP1W-32ET1
I/O Units
3777_lu_7_3
128Relay0.1030.044CP1W-20EDR1
Transistor (sinking)0.130---CP1W-20EDT
Transistor (sourcing)0.130---CP1W-20EDT1
2416Relay0.0800.090CP1W-40EDR
Transistor (sinking)0.160---CP1W-40EDT
Transistor (sourcing)0.160---CP1W-40EDT1
CP1W
Expansion
Units
Analog Input
Unit
3777_lu_7_4
4CH---Input range: 0 to 5 V,
1 to 5 V, 0 to 10 V, ±10 V,
0 to 20 mA, or 4 to 20 mA.
Resolution:
1/6000
0.1000.090CP1W-AD041
Resolution:
1/12000
0.1000.050CP1W-AD042
Analog Output
Unit
3777_lu_7_5
---2CHOutput range:
1 to 5 V, 0 to 10 V, ±10 V,
0 to 20 mA, or 4 to 20 mA.
Resolution:
1/6000
0.0400.095CP1W-DA021
---4CHResolution:
1/6000
0.0800.124CP1W-DA041
Resolution:
1/12000
0.0700.160CP1W-DA042
Analog I/O Unit
3777_lu_7_6
4CH4CHInput range: 0 to 5 V,
1 to 5 V, 0 to 10 V, ±10 V,
0 to 20 mA, or 4 to 20 mA.
Output range:
1 to 5 V, 0 to 10 V, ±10 V,
0 to 20 mA, or 4 to 20 mA.
Resolution:
1/12000
0.1200.170CP1W-MAD44
4CH2CHResolution:
1/12000
0.1200.120CP1W-MAD42
2CH1CHResolution:
1/6000
0.0830.110CP1W-MAD11
Temperature
Sensor Unit
3777_lu_7_7
2CH---Sensor type: Thermocouple (J or K)0.0400.059CP1W-TS001
4CH---Sensor type: Thermocouple (J or K)0.0400.059CP1W-TS002
2CH---Sensor type: Platinum resistance
thermometer (Pt100 or JPt100)
0.0540.073CP1W-TS101
4CH---Sensor type: Platinum resistance
thermometer (Pt100 or JPt100)
0.0540.073CP1W-TS102
4CH---Sensor type:
Thermocouple (J or K)
2channels can be used
as analog input.
Input range: 1 to 5 V, 0 to
10 V, 4-20 mA
Resolution:
1/12000
0.0700.030CP1W-TS003
12CH---Sensor type: Thermocouple (J or K)0.0800.050CP1W-TS004

I/O Connecting Cable

Product nameSpecificationsModel
I/O Connecting Cable80 cm (for CP1W Expansion I/O Units and Expansion Units)
Only one I/O Connecting Cable can be used in each PLC.
CP1W-CN811

Recommended Ethernet Communications Cables

For the Ethernet communications cable specifications, refer to Catalog
ItemRecommended
manufacturer
Cable
length (m)
Model
Wire Gauge and
Number of Pairs:
AWG26, 4-pair Cable
Cable Sheath material:
LSZH *2
Cable with Connectors on
Both Ends (RJ45/RJ45)
Standard RJ45 plug type *1
Cable color: Yellow *3
3777_lu_11_1
OMRON0.3XS6W-6LSZH8SS30CM-Y
0.5XS6W-6LSZH8SS50CM-Y
1XS6W-6LSZH8SS100CM-Y
2XS6W-6LSZH8SS200CM-Y
3XS6W-6LSZH8SS300CM-Y
5XS6W-6LSZH8SS500CM-Y
Wire Gauge and
Number of Pairs:
AWG22, 2-pair cable
Cable with Connectors on
Both Ends (RJ45/RJ45)
Rugged RJ45 plug type *1
Cable color: Light blue
3777_lu_11_2
OMRON0.3XS5W-T421-AMD-K
0.5XS5W-T421-BMD-K
1XS5W-T421-CMD-K
2XS5W-T421-DMD-K
5XS5W-T421-GMD-K
10XS5W-T421-JMD-K
*1. Cables with standard RJ45 plugs are available in the following lengths: 0.2 m, 0.3 m, 0.5 m, 1 m, 1.5 m, 2 m, 3 m, 5 m,
  7.5 m, 10 m, 15 m, 20 m.
  Cables with rugged RJ45 plugs are available in the following lengths: 0.3 m, 0.5 m, 1 m, 2 m, 3 m, 5 m, 10 m, 15 m.
  For details, refer to the Industrial Ethernet Connectors Catalog (Cat. No. G019).
*2. The lineup features Low Smoke Zero Halogen cables for in-cabinet use and PUR cables for out-of-cabinet use.
  Although the LSZH cable is single shielded, its communications and noise characteristics meet the standards.
*3. Cable colors are available in yellow, green, and blue.
*4. For details, contact your OMRON representative.

RS-232C Connecting Cable

NameSpecificationsModel
PT-to-PLC
Connecting Cable
Connection cable with programmable terminal NB / NS
For CP2E-N+CP1W-CIF01
Length: 2 mXW2Z-200T
Length: 5 mXW2Z-500T
Connection cable with programmable terminal NB / NS
For CP2E-S/E, CP2E-N+CP2W-CIFD1/CIFD2
Length: 2 mXW2Z-200T-3
Length: 5 mXW2Z-500T-3

DIN Track Accessories

NameSpecificationsModel
DIN TrackLength: 0.5 m; Height: 7.3 mmPFP-50N
Length: 1 m; Height: 7.3 mmPFP-100N
Length: 1 m; Height: 16 mmPFP-100N2
End PlateA stopper to secure the Units on the DIN Track.PFP-M

Programming Devices

Software

Product
name
SpecificationsModel
Number of
licenses
Media
FA Integrated
Tool Package
CX-One Lite
Ver.4.[]
CX-One Lite is a subset of the complete CX-One package
that provides only the Support Software required for micro
PLC applications.
CX-One Lite runs on the following OS.
OS: Windows XP (Service Pack 3 or higher, 32-bit
version) / Windows Vista (32-bit/64-bit version) / Windows
7 (32-bit/64-bit version) / Windows 8 (32-bit/64-bit
version) / Windows 8.1 (32-bit/64-bit version) / Windows
10 (32-bit/64-bit version)
CX-One Lite Ver. 4.[] includes Micro PLC Edition
CX-Programmer Ver.9.[].
1 licenseDVDCXONE-LT01D-V4
FA Integrated
Tool Package
CX-One
Package
Ver. 4.[]
CX-One is a comprehensive software package that
integrates Support Software for OMRON PLCs and
components. CX-One runs on the following OS.
OS: Windows XP (Service Pack 3 or higher, 32-bit
version) / Windows Vista (32-bit/64-bit version) / Windows
7 (32-bit/64-bit version) / Windows 8 (32-bit/64-bit
version) / Windows 8.1 (32-bit/64-bit version) / Windows
10 (32-bit/64-bit version)
CX-One Ver. 4.[] includes CX-Programmer Ver. 9.[].
1 license
*1
DVDCXONE-AL01D-V4
Note: 1. CP2E CPU Units are supported by CX-One version 4.51 or higher and CX-Programmer version 9.72 or higher.
         2. The CX-One and CX-One Lite cannot be simultaneously installed on the same computer.
         3. For details, refer to the CX-One Catalog (Cat. No. R134).
*1. Multi licenses (3, 10, 30, or 50 licenses) and DVD media without licenses are also available for the CX-One.