Kontak Kami

KONTAK KAMI : Telpon : 02126071413 Hp/WhatsApp : 081212269831 Perwakilan Jakarta : Gedung LTC Glodok Lantai 1 Blok C30 No.31 Jl.Hayam Wuruk No.127 Jakarta , Indonesia
Tampilkan postingan dengan label CJ1W-NC881. Tampilkan semua postingan
Tampilkan postingan dengan label CJ1W-NC881. Tampilkan semua postingan

Kamis, 27 Juli 2017

CJ1W-NC[]81 / []82 CJ-series Position Control Units with EtherCAT interface: CJ1W-NC281,CJ1W-NC481,CJ1W-NC881,CJ1W-NCF81,CJ1W-NC482,CJ1W-NC882,CJ1W-NCF82


- CJ1 CPU Bus Units, Position Control Units with Ether Cat interface, Control output interface control commands executed by EtherCAT Communications positioning function Memory operation Direct operation by ladder programming, No of axes 2 axes, No unit numbers allocated 1, Current Consumption (A) 5 V 0.46   : CJ1W-NC281
- CJ1 CPU Bus Unit, Position Control Units with Ether CAT interface, Control output interface Control commands executed by EtherCAT communications positioning Function Memory operation Direct Operation by ladder Programming, No of axes 4 axes, No of unit numbers allocated 1, Current consumption (A) 5 V 0.46  : CJ1W-NC481
- CJ1 CPU Bus Unit, Position Control Units with EtherCAT interface, Control output interface Control commands  executed by EtherCAT communications positioning Functions Memory operation Direct operation by ladder programming, No of axes 8 axes, No f unit numbers allocated 1, Current Consumption (A) 5 V 0.46  : CJ1W-NC881
- CJ1 CPU Bus Units, Position Control Units with EtherCAT interface, Control output interface Control commands executed EtherCAT communications positioning function Memory operation Direct operation by ladder programming, No of axes 16 axes, No of unit numbers allocated 1, Current consumption (A) 5 V 0,46   : CJ1W-NCF81
- CJ1 CPU Bus Unit, Position Control Units with EtherCAT interface, Control output interface Control commands executed by EtherCAT communications Positioning function Memory operation Direct operation by ladder programming I/O communications 64 nodes, No of axes 4 axes, No of unit numbers allocated 1, Current Consumption (A) 5 V  0,46  : CJ1W-NC482
- CJ1 CPU Bus Units , Position Control Units with EtherCAT interface, Control output interface Control commands executed by EtherCAT communications Positioning function Memory operation Direct operation by ladder programming I/O communications 64 nodes, No of axes 8 axes, No of unit numbers allocated 1, Current Consumption (A) 5 V 0.46  : CJ1W-NC882
- CJ1 CPU Bus Units, Position Control units with EtherCAT interface, Control output interface Control commands executed by EtherCAT positioning function Memory operation Direct operation by ladder programmingI/O communication 64 nodes, No of axes 16 axes, No of unit numbers allocated 1, Current consumption (A) 5 V 0.46  : CJ1W-NCF82