CJ1W-PA / PD CJ-series Power Supply Unit: CJ1W-PA205C,CJ1W-PA205R,CJ1W-PA202,CJ1W-PD025,CJ1W-PD022
- AC Power Supply Unit, Power supply Voltage 100 to 240 VAC, Output capacity 5-VDC output capacity 5 A 24-VDC output capacity 0,8 A Total power consumption 25 W, Options 24-VDC service power supply No RUN output No Maintenance forecast monitor Yes : CJ1W-PA205C
- AC Power Supply Unit, Power Supply Voltage 100 to 240 VAC, 5-VDC output Capacity 5 A 24-VDC output capacity 0,8 A Total Consumption 25 W, Options 24-VDC service power supply No, RUN output No, Maintenance forecast monitor Yes : CJ1W-PA205R
- AC Power Supply Unit, Power Supply Voltage 100 to 240 VAC, Output capacity 5-VDC output capacity 2,8 A 24-VDC output capacity 0,4 A Total Power consumption 14 W, Options 24-VDC service power supply No RUN output No Maintenance forecast monitor No : CJ1W-PA202
- DC Power Supply Unit, Power supply Voltage 24 VDC, Output capacity 5-VDC Output capacity 5 A 24-VDC Output capacity 0,8 A Total power Consumption 25 W, Options 24 VDC Service power supply No RUN output No Maintenance forecast monitor No : CJ1W-PD025
- DC Power Supply Unit, Power supply Voltage 24 VDC, Output Capacity 5-VDC Output capacity 2 A 24-VDC output capacity 0,4 A Total Power Consumption 19,6 W, Options 24-VDCservice power supply No, RUN output No Maintenance forecast monitor No : CJ1W-PD022
Selasa, 25 Juli 2017
CJ-series Power Supply Unit CJ1W-PA / PD : CJ1W-PA205C,CJ1W-PA205R,CJ1W-PA202,CJ1W-PD025,CJ1W-PD022
- Power supply voltage, 100 to 240 VAC, 5-VDC ouput capacity 5 A, 24-VDC output capacity 0.8 A, Total service power supply No, RUN output No, Maintenance forecast monitor Yes : CJ1W-PA205C
- Power supply voltage 100 to 240 VAC, 5-VDC output capacity 5 A, 24-VDC output capacity 0.8 A, Total power conpsumption25 W, 24-VDC service power supply No, RUN output Yes , Maintenance forcast monitor No : CJ1W-PA205R
- Power supply 100 to 240 VAC, 5-VDC output capacity 2.8 A, 24-VDC outptu capacity 0.4 A,Total power consumption 14 W, 24 service power supply voltage No, RUN capacity No : CJ1W-PA202
- Power supply voltage 24 VDC, 5-VDC output capacity 5A, 24-VDC output capacity 0.8 A, Total power consumpition 25 W, 24-VDC service power supply No, RUN output No, Maintenance forecast monitor No : CJ1W-PD025
- Poower supply voltage 24 VDC, 5-VDC output capacity 2 A, 24-VDC output capacity 0.4 A, 24-VDC output capacity 0.4 A, Total power conusmption 19.6 W , Service power supply No, Maintenance forecast monitor No : CJ1W-PD022
Jumat, 13 Januari 2017
Jual Power Supply Omron CJ1W-PA205R
DescriptionAC Supply Unit - OMRON (CJ1W-PA) - (AC) 100-240V supply voltage - (Output; 5Vdc) 5A - (24 VDC output capacity) 0.8A - (Output capacity) 25W - 1
Specifications
Supply voltage
(AC) 100-240 V
Rated current
(Output; 5Vdc) 5 A
(24 VDC output capacity) 0.8 A
Rated power
(Output capacity) 25 W
Power consumption
100 VA
Compliant with standard(s)
cULus Class I Division 2
NK
Lloyd
EC Directives
Digital outputs quantity
1
Digital outputs
(RUN output) SPST-NO (Single Pole Single Throw - Normally Open)
Primary brand
OMRON
Range name
CJ1W-PA
Jumat, 30 Desember 2016
Jual Power Supply Unit CJ-series
CJ1W-PA/PD
Equipped with the RUN output for checking the operation status, as well as the replacement notification function for easy maintenance. Lineup of five models including the AC power supply (25W).
The replacement notification function can prevent an overflow of the system due to the power lifetime. (CJ1W-PA205C only)
Power Supply Unit provides wide variations according to the system scale up to maximum 25 W.
Power Supply Unit provides wide variations according to the power supply (100 to 240 V AC/ 24 V DC) status.
The output contact during operation enables you to check the CPU operation. (CJ1W-PA205R only)
Conforming to the SEMI-F47 Standard. *
*AC input type, 200 V min. input.
Power Supply Unit provides wide variations according to the system scale up to maximum 25 W.
Power Supply Unit provides wide variations according to the power supply (100 to 240 V AC/ 24 V DC) status.
The output contact during operation enables you to check the CPU operation. (CJ1W-PA205R only)
Conforming to the SEMI-F47 Standard. *
*AC input type, 200 V min. input.
Specifications :
Item | Specifications | ||
Model | CJ1W-PA205R | CJ1W-PA205C | CJ1W-PA202 |
Supply voltage | 100 to 240 V AC (wide-range), 50/60 Hz | ||
Operating voltage and frequency ranges | 85 to 264 V AC, 47 to 63 Hz | ||
Power consumption | 100 VA max. | 50 VA max. | |
Inrush current *1 | At 100 to 120 V AC: 15 A/8 ms max. for cold start at room temperature At 200 to 240 V AC: 30 A/8 ms max. for cold start at room temperature | At 100 to 120 V AC: 20 A/8 ms max. for cold start at room temperature At 200 to 240 V AC: 40 A/8 ms max. for cold start at room temperature | |
Output capacity *7 | 5.0 A, 5 V DC (including supply to CPU Unit) | 2.8 A, 5 V DC (including supply to CPU Unit) | |
0.8 A, 24 V DC | 0.4 A, 24 V DC | ||
Total: 25 W max. | Total: 14 W max. | ||
Output terminal (service supply) | Not provided. | ||
RUN output *2 | Contact configuration: SPST-NO Switch capacity: 250 V AC, 2 A (resistive load) 120 V AC, 0.5 A (inductive load), 24 V DC, 2A (resistive load) 24 V DC, 2 A (inductive load) | Not provided. | |
Replacement notification function | Not provided. | With Alarm output (open-collector output) 30 V DC max., 50 mA max. | Not provided. |
Insulation resistance | 20 MΩ min. (at 500 V DC) between AC external and GR terminals *3 | 20 MΩ min. (at 500 V DC) between all external terminals and GR terminal *3, and between all alarm output terminals. 20 MΩ 1 min. (at 250 V DC) between all alarm output terminals and GR terminal *3. | 20 MΩ min. (at 500 V DC) between AC external and GR terminals *3 |
Dielectric strength *4 | 2,300 V AC 50/60 Hz for 1 min between AC external and GR terminals *3 Leakage current: 10 mA max. | 2,300 VAC, 50/60 Hz for 1 min between all external terminals and GR terminal *3 and between all alarm output terminals with a leakage current of 10 mA max. 1,000 V AC, 50/60 Hz for 1 min between all alarm output terminals and GR terminal *3 with a leakage current of 10 mA max. | 2,300 V AC 50/60 Hz for 1 min between AC external and GR terminals *3 Leakage current: 10 mA max. |
1,000 V AC, 50/60 Hz for 1 minute between DC external and GR terminals *3 Leakage current: 10 mA max. | |||
Noise immunity | 2 kV on power supply line (conforming to IEC61000-4-4) | ||
Vibration resistance | Conforms to IEC60068-2-6 5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz Acceleration of 9.8 m/s2 for 100 min in X, Y, and Z directions (10 sweeps of 10 min each = 100 min) | ||
Shock resistance | Conforms to IEC60068-2-27 147 m/s2, 3 times in X, Y, and Z directions (100 m/s2 for Relay Output Units) | ||
Ambient operating temperature | 0 to 55 ° C | ||
Ambient operating humidity | 10% to 90% (with no condensation) | 10% to 90% (with no condensation) *5 | 10% to 90% (with no condensation) |
Atmosphere | Must be free from corrosive gases. | ||
Ambient storage temperature | - 20 to 70 ° C (excluding battery) | - 20 to 75 ° C *5 | - 20 to 75 ° C (excluding battery) |
Grounding | Less than 100 Ω | ||
Enclosure | Mounted in a panel. | ||
Weight | All models are each 5 kg max. | ||
CPU Rack dimensions | 90.7 to 466.7 × 90 × 65 mm (W × H × D) (not including cables) Note: W = a + b + 20 × n + 31 × m + 14.7 a: Power Supply Unit: PA205R and PA205C = 80; PA202 = 45; PD025 = 60; PD022=27 b: CPU Unit: CJ1-H or CJ1 = 62; CJ1M-CPU1[] = 31; CJ1M-CPU2[] = 49 The total width is given by the following: W = 156.7 + n × 20 + m × 31, where n is the number of 32-point I/O Units or I/O Control Units and m is the number of other Units. | ||
Safety measures | Conforms to cULus and EC Directives. |
Item Power Supply Unit | Specifications | |
CJ1W-PD025 | CJ1W-PD022 | |
Supply voltage | 24 VDC | |
Operating voltage and frequency ranges | 19.2 to 28.8 V DC | 21.6 to 26.4 V DC |
Power consumption | 50 W max. | 35 W max. |
Inrush current *1 | At 24 V DC: 30 A/20 ms max. for cold start | |
Output capacity *7 | 5.0 A, 5 V DC (including supply to CPU Unit) | 2.0 A, 5 V DC (including supply to CPU Unit) |
0.8 A, 24 V DC | 0.4 A, 24 V DC | |
Total: 25 W max. | Total: 19.6 W max. | |
Output terminal (service supply) | Not provided. | |
RUN output *2 | Not provided. | |
Replacement notification function | Not provided. | |
Insulation resistance | 20 MΩ min. (at 500 V DC) between DC external and GR terminals *3 | --- *6 |
Dielectric strength *4 | 1,000 V AC, 50/60 Hz for 1 min between DC external and GR terminals *3 Leakage current: 10 mA max. | --- *6 |
Noise immunity | 2 kV on power supply line (conforming to IEC61000-4-4) | |
Vibration resistance | Conforms to IEC60068-2-6 5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz Acceleration of 9.8 m/s2 for 100 min in X, Y, and Z directions (10 sweeps of 10 min each = 100 min) | |
Shock resistance | Conforms to IEC60068-2-27 147 m/s2, 3 times in X, Y, and Z directions (100 m/s2 for Relay Output Units) | |
Ambient operating temperature | 0 to 55 ° C | |
Ambient operating humidity | 10% to 90% (with no condensation) | |
Atmosphere | Must be free from corrosive gases. | |
Ambient storage temperature | - 20 to 75 ° C (excluding battery) | |
Grounding | Less than 100 Ω | |
Enclosure | Mounted in a panel. | |
Weight | All models are each 5 kg max. | |
CPU Rack dimensions | 90.7 to 466.7 × 90 × 65 mm (W × H × D) (not including cables) Note: W = a + b + 20 × n + 31 × m + 14.7 a: Power Supply Unit: PA205R and PA205C = 80; PA202 = 45; PD025 = 60; PD022=27 b: CPU Unit: CJ1-H or CJ1 = 62; CJ1M-CPU1[] = 31; CJ1M-CPU2[] = 49 The total width is given by the following: W = 156.7 + n × 20 + m × 31, where n is the number of 32-point I/O Units or I/O Control Units and m is the number of other Units. | |
Safety measures | Conforms to cULus and EC Directives. |
*1.Disconnect the Power Supply Units LG terminal from the GR terminal when testing insulation and dielectric strength. Testing the insulation and dielectric strength with the LG terminal and the GR terminals connected will damage internal circuits in the CPU Unit.
*2.Supported only when mounted to CPU Rack.
*3.The inrush current is given for a cold start at room temperature. The inrush control circuit uses a thermistor element with a low-temperature current control characteristic. If the ambient temperature is high or the PLC is hot-started, the thermistor will not be sufficiently cool, and the inrush currents given in the table may be exceeded by up to twice the given values. When selecting fuses or breakers for external circuits, allow sufficient margin in shut-off performance.
*4.Maintain an ambient storage temperature of −25 to 30°C and relative humidity of 25% to 70% when storing the Unit for longer than 3 months to keep the replacement notification function in optimum working condition.
*5.Change the applied voltage gradually using the adjuster on the Tester. If the full dielectric strength voltage is applied or turned OFF using the switch on the Tester, the generated impulse voltage may damage the Power Supply Unit.
*6.CJ1W-PD022 is not insulated between the primary DC power and secondary DC power.
*7.Internal components in the Power Supply Unit will deteriorate or be damaged if the Power Supply Unit is used for an extended period of time exceeding the power supply output capacity or if the outputs are shorted.
Checking Current Consumption and Power Consumption
After selecting a Power Supply Unit based on considerations such as the power supply voltage, calculate the current and power requirements for each Rack.
Condition 1: Current Requirements
There are two voltage groups for internal power consumption: 5 V and 24 V.
Current consumption at 5 V (internal logic power supply)
Current consumption at 24 V (relay driving power supply)
Condition 2: Power Requirements
For each Rack, the upper limits are determined for the current and power that can be provided to the mounted Units. Design the system so that the total current consumption for all the mounted Units does not exceed the maximum total power or the maximum current supplied for the voltage groups shown in the following tables.
The maximum current and total power supplied for CPU Racks and Expansion Racks according to the Power Supply Unit model are shown below.
Note:
1.For CPU Racks, include the CPU Unit current and power consumption in the calculations. When expanding, also include the current and power consumption of the I/O Control Unit in the calculations.
2.For Expansion Racks, include the I/O Interface Unit current and power consumption in the calculations.
*2.Supported only when mounted to CPU Rack.
*3.The inrush current is given for a cold start at room temperature. The inrush control circuit uses a thermistor element with a low-temperature current control characteristic. If the ambient temperature is high or the PLC is hot-started, the thermistor will not be sufficiently cool, and the inrush currents given in the table may be exceeded by up to twice the given values. When selecting fuses or breakers for external circuits, allow sufficient margin in shut-off performance.
*4.Maintain an ambient storage temperature of −25 to 30°C and relative humidity of 25% to 70% when storing the Unit for longer than 3 months to keep the replacement notification function in optimum working condition.
*5.Change the applied voltage gradually using the adjuster on the Tester. If the full dielectric strength voltage is applied or turned OFF using the switch on the Tester, the generated impulse voltage may damage the Power Supply Unit.
*6.CJ1W-PD022 is not insulated between the primary DC power and secondary DC power.
*7.Internal components in the Power Supply Unit will deteriorate or be damaged if the Power Supply Unit is used for an extended period of time exceeding the power supply output capacity or if the outputs are shorted.
Checking Current Consumption and Power Consumption
After selecting a Power Supply Unit based on considerations such as the power supply voltage, calculate the current and power requirements for each Rack.
Condition 1: Current Requirements
There are two voltage groups for internal power consumption: 5 V and 24 V.
Current consumption at 5 V (internal logic power supply)
Current consumption at 24 V (relay driving power supply)
Condition 2: Power Requirements
For each Rack, the upper limits are determined for the current and power that can be provided to the mounted Units. Design the system so that the total current consumption for all the mounted Units does not exceed the maximum total power or the maximum current supplied for the voltage groups shown in the following tables.
The maximum current and total power supplied for CPU Racks and Expansion Racks according to the Power Supply Unit model are shown below.
Note:
1.For CPU Racks, include the CPU Unit current and power consumption in the calculations. When expanding, also include the current and power consumption of the I/O Control Unit in the calculations.
2.For Expansion Racks, include the I/O Interface Unit current and power consumption in the calculations.
Power Supply Units | Max. current supplied | Max. total power supplied | |
5 V | 24 V (relay driving current) | ||
CJ1W-PA205R | 5.0 A | 0.8 A | 25 W |
CJ1W-PA205C | 5.0 A | 0.8 A | 25 W |
CJ1W-PA202 | 2.8 A | 0.4 A | 14 W |
CJ1W-PD025 | 5.0 A | 0.8 A | 25 W |
CJ1W-PD022 | 2.0 A | 0.4 A | 19.6 W |
Conditions 1 and 2 below must be satisfied.
Condition 1: Maximum Current
(1)Total Unit current consumption at 5 V ≤ (A) value
(2)Total Unit current consumption at 24 V ≤ (B) value
Condition 2: Maximum Power
(1) × 5 V + (2) × 24 V ≤ (C) value
Example: Calculating Total Current and Power Consumption
Example: When the Following Units are Mounted to a CJ-series CPU Rack Using a CJ1W-PA202 Power Supply Unit
Condition 1: Maximum Current
(1)Total Unit current consumption at 5 V ≤ (A) value
(2)Total Unit current consumption at 24 V ≤ (B) value
Condition 2: Maximum Power
(1) × 5 V + (2) × 24 V ≤ (C) value
Example: Calculating Total Current and Power Consumption
Example: When the Following Units are Mounted to a CJ-series CPU Rack Using a CJ1W-PA202 Power Supply Unit
Unit type | Model | Quantity | Voltage group | |
5 V | 24 V | |||
CPU Unit | CJ1G-CPU45H | 1 | 0.910 A | --- |
I/O Control Unit | CJ1W-IC101 | 1 | 0.020 A | --- |
Basic I/O Units (Input Units) | CJ1W-ID211 | 2 | 0.080 A | --- |
CJ1W-ID231 | 2 | 0.090 A | --- | |
Basic I/O Units (Output Units) | CJ1W-OC201 | 2 | 0.090 A | 0.048 A |
Special I/O Unit | CJ1W-DA041 | 1 | 0.120 A | --- |
CPU Bus Unit | CJ1W-CLK23 | 1 | 0.350 A | --- |
Current consumption | Total | 0.910 + 0.020 + 0.080 × 2 + 0.090 × 2 + 0.090 × 2 + 0.120 + 0.350 | 0.048 A × 2 | |
Result | 1.92 A ( ≤ 2.8 A) | 0.096 A ( ≤ 0.4 A) | ||
Power consumption | Total | 1.92 × 5 V = 9.60 W | 0.096 A × 24 V = 2.304 W | |
Result | 9.60 + 2.304 11.904 W ( ≤ 14 W) |
Jumat, 06 Desember 2013
JUAL AC POWER SUPPLY UNITS CJ1W-PA205R
Equipped with the RUN output for
checking the operation status, as
well as the replacement
notification function for easy
maintenance.
Lineup of five models including the
AC power supply (25W)
• Stable power supply is available from the CJ-series
CPU Unit to each I/O Units via the dedicated bus. The
most suitable Power Supply Unit can be selected among various I/O specifications and/or options
Spesification CJ1W-PA205R
- AC Power Supply Unit
- Power supply voltage : 100 to 240 VAC
- 5-VDC Output Capasity : 5A
checking the operation status, as
well as the replacement
notification function for easy
maintenance.
Lineup of five models including the
AC power supply (25W)
• Stable power supply is available from the CJ-series
CPU Unit to each I/O Units via the dedicated bus. The
most suitable Power Supply Unit can be selected among various I/O specifications and/or options
Spesification CJ1W-PA205R
- AC Power Supply Unit
- Power supply voltage : 100 to 240 VAC
- 5-VDC Output Capasity : 5A
- 24-VDC Output Capasity : 0,8A
- Total power consumption : 25 W
- 24-VDCservice power supply : No
- RUN Output : Yes
- Maintenance forecast monitor : No
Untuk Informasi harga dan stock, hubungi :
AUTOMATION JAYA
PIN BB: 76067C56
YM : automationjaya
HP:081212269831
TLP: 021-91598769
WEB: www.automation-jaya.com
EMAIL: automation.jaya@gmail.com
Twitter : @AutomationJaya
Facebook : Automation Jaya
Senin, 16 September 2013
CJ1W-PA202, CJ1W-PA205R, CJ1W-PD025, CJ1W-SCU21-V1, CJ1W-SCU41-V1, CJ1W-CLK23, CJ1W-TC101, C500-CE404, CJ1W-TER01
CJ1W-PA202
CJ1W-PA205R
CJ1W-PD025
CJ1W-SCU21-V1
CJ1W-SCU41-V1
CJ1W-CLK23
CJ1W-TC101
C500-CE404
CJ1W-TER01
Contact Person:
Bp. Bowo
Bp. Bowo
TLp: 021-91598769
HP: 081212269831
Email: automation.jaya@ gmail.com
Web : www.automation-jaya.com
Langganan:
Postingan (Atom)