Kontak Kami

KONTAK KAMI : Telpon : 02126071413 Hp/WhatsApp : 081212269831 Perwakilan Jakarta : Gedung LTC Glodok Lantai 1 Blok C30 No.31 Jl.Hayam Wuruk No.127 Jakarta , Indonesia
Tampilkan postingan dengan label FX3G-232-BD. Tampilkan semua postingan
Tampilkan postingan dengan label FX3G-232-BD. Tampilkan semua postingan

Rabu, 20 Maret 2019

FX3G-232-BD


Spesifications

More Information
Condition:New
Weight (kg):0.02
Our Part Number:FX3G232BD
Height (mm):51.2
Width (mm):35
Depth (mm):17.2
Brand:Mitsubishi
Manufacturer Series:FX3G
Manufacturer Range:FX Series
Short Description:Mitsubishi Fx3s/3g Interface Module Rs232c Number inputs:40 Number Outputs:40
Supply Voltage              :100 to 240 Volt

Rabu, 31 Januari 2018

Serial Communication : FX3U-232-BD,FX3U-485-BD,FX3G-485-BD,FX3G-232-BD,FX2NC-232ADP,FX2NC-485ADP,FX3U-232ADP-MB,FX3U-485ADP-MB

For related system and data transfer with external equipment and third party devices, serial communication has long been the established connection method. Serial communication allows the FX Series to connect both efficiently and reliably with other PLCs, sensor, printers, and modems, etc. Multi drop networks , non-protocol communication, and remote maintenance are just some of the many uses.

Modbus
Both an open network and a serial communicator, Modbus-RTU allows FX3 series PLCs to interface with a wide range of equipment and devices. Using RS-485 and RS-232, the FX3U-485ADP-MD and FX3U-232ADP-MB expand the networking capabilities of the FX system while still supporting general communication with other FX systems, non-protocol devices, and serial modems. 
Modbus serial communication parameters and communication execution are setup easily within the ladder program using GX Works2 or GX Developer, and the FX Modbus Master uses the special ADPRW instruction to communicate with up to 16 Slave stations.

Serial Communication


FX3U-232-BD



FX3U-485-BD


FX3G-485-BD



FX3G-232-BD

FX2NC-232ADP



FX2NC-485ADP


Modbus



FX3U-232ADP-MB



FX3U-485ADP-MB


Communications Protocols

N:N Network
Connect up to 8 FX PLCs using N:N Networking to allow 
data exchange between each station.

Computer Link (Dedicated Protocol)
1:N Computer to PLC Communication with a network of up to 16 FX, A, and Q PLCs

1:1 RS-232 Communication Equipment to PLC When communicating over an RS-232 interface, the PC can communicate with one FX PLC.

Parallel Link
Auxiliary Relays (M) and Data Register (D) are update automatically between  two PLCs of the same series

Remote Maintenance
Using a modem connection, a PC an monitor/force devices and perform program upload/download to a PLC from remote locations

Non-Protocol Communication is possible between a PLC and any external equipment with an RS -232C or RS-485 (RS-422) interface