FX3G-485-BD


Spesifications

  • Manufacturer: Mitsubishi Electric 
  • RS-485 communication for function expansion board FX3G-485-BD
  • Transmission standard : RS-485 standard, conform to the RS-422 standard 
  • Insulation method : Non-insulated (between the communication line and the CPU) 
  • Transmission distance : Up to 50m 
  • External device connection method : Europe terminal blocks 
  • Communication system : Half-duplex bi-directional 
  • Communication procedure : Non-procedural, computer link (dedicated protocol format 1, dedicated protocol format 4), parallel link, a simple PC-to-PC link, inverter communication
    FX3G is compatible with the inverter communication later Ver.1.10. 
  • communication speed No-protocol, the computer link : 300/600/1200/2400/4800/9600/19200/38400 (bps) 
  • Parallel link : 115200 (bps) 
  • Simple PC-to-PC link : 38400 (bps) 
  • Inverter communication : 4800/9600/19200/38400 (bps) 
  • Display (LED) : RD, SD 
  • O occupied points : 0 points (no relation to the maximum input and output points of the sequencer) 
  • Apply sequencer : FX3S, FX3G
    FX3S when connected, can not be used in conjunction function expansion board and FX3S-CNV-ADP. 
  • Ambient temperature : 0 ~ 55 °C ····· operation, -25 ~ 75 °C ····· during storage 
  • Relative humidity : 5 ~ 95% RH (non-condensing) ...... operation 
  • Vibration resistance When the DIN rail mounting Frequency: 10 ~ 57Hz : Half amplitude: 0.035mm X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Frequency: 57 ~ 150Hz : Acceleration: 4.9m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Direct mounting at the time Frequency: 10 ~ 57Hz : Half amplitude: 0.075mm X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Frequency: 57 ~ 150Hz : Acceleration: 9.8m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Impact : 147m / s2, duration of action 11ms, X at half-sine pulse, Y, Z directions 3 times each 
  • Anti-noise : Noise voltage 1,000Vp-p, noise width 1μs, due to rising 1ns, cycle 30 ~ 100Hz of noise simulator 
  • Withstand voltage : Non-isolated between communication line and the PLC main unit
    (Please do not withstand voltage test) 
  • Insulation resistance : Non-isolated between communication line and the PLC main unit
    (Please do not insulation resistance test) 
  • Use atmosphere : Corrosive, there is no flammable gas, conductive dust (dust) that is not terribly 
  • Advanced use : 2,000m or less (can not be used under the pressurized environment to more than atmospheric pressure. There is a possibility of failure.)
  • Shipping Weight : 1 Kg

Rabu, 31 Januari 2018

Serial Communication : FX3U-232-BD,FX3U-485-BD,FX3G-485-BD,FX3G-232-BD,FX2NC-232ADP,FX2NC-485ADP,FX3U-232ADP-MB,FX3U-485ADP-MB

For related system and data transfer with external equipment and third party devices, serial communication has long been the established connection method. Serial communication allows the FX Series to connect both efficiently and reliably with other PLCs, sensor, printers, and modems, etc. Multi drop networks , non-protocol communication, and remote maintenance are just some of the many uses.

Modbus
Both an open network and a serial communicator, Modbus-RTU allows FX3 series PLCs to interface with a wide range of equipment and devices. Using RS-485 and RS-232, the FX3U-485ADP-MD and FX3U-232ADP-MB expand the networking capabilities of the FX system while still supporting general communication with other FX systems, non-protocol devices, and serial modems. 
Modbus serial communication parameters and communication execution are setup easily within the ladder program using GX Works2 or GX Developer, and the FX Modbus Master uses the special ADPRW instruction to communicate with up to 16 Slave stations.

Serial Communication


FX3U-232-BD



FX3U-485-BD


FX3G-485-BD



FX3G-232-BD

FX2NC-232ADP



FX2NC-485ADP


Modbus



FX3U-232ADP-MB



FX3U-485ADP-MB


Communications Protocols

N:N Network
Connect up to 8 FX PLCs using N:N Networking to allow 
data exchange between each station.

Computer Link (Dedicated Protocol)
1:N Computer to PLC Communication with a network of up to 16 FX, A, and Q PLCs

1:1 RS-232 Communication Equipment to PLC When communicating over an RS-232 interface, the PC can communicate with one FX PLC.

Parallel Link
Auxiliary Relays (M) and Data Register (D) are update automatically between  two PLCs of the same series

Remote Maintenance
Using a modem connection, a PC an monitor/force devices and perform program upload/download to a PLC from remote locations

Non-Protocol Communication is possible between a PLC and any external equipment with an RS -232C or RS-485 (RS-422) interface