FX3S Main Units with 10-14 I/0 FX3S-14MR/ES

Specifications
AttributeValue
For Use WithFX3 Series
Number of I/O14
Manufacturer SeriesFX3S
Number of Inputs8
Input TypeDC
Voltage Category100 → 240 V ac
Output TypeRelay, Transistor
Number of Outputs6
Network TypeEthernet, ModBus
Communication Port TypeRS422, USB
Program Capacity4000 Steps
Number of Communication Ports2
Width75mm
Output Current2 A
Memory4000 Steps
Programming Language UsedInstruction List, SFC, Step Ladder
Maximum Operating Temperature+55°C
Minimum Operating Temperature0°C
Dimensions60 x 75 x 90 mm
Mounting TypeWall Mount
Depth90mm
Length60mm
Maximum Inputs/Outputs14

Kamis, 15 Februari 2018

PLC Mitsubishi FX3S Melsec Compact PLC :FX3S-10MR/ES,FX3S-14MR/ES,FX3S-20MR/ES,FX3S-30MR/ES,FX3S-30MR/ES-2AD

New Possibilities
The compact PLC is especially well suited for food and beverage applications, as well as material handling, and fan and pump application for irrigation and building automation.

Enhanced expandability
Beside the standard built-in RS-422 interface port for serial communication with 115.2 kbps, the FX3S can use a large range of adapters providing RS232,RS485,RS422 and Ethernet communication options. These can be used to connect and control various third party products such as bar code readers or panel printers. In addition, compact expansion boards for additional digital inputs  and  outputs are available, which can be plugged directly into the controller without any additional installation  space required  on the right or left of the controller. A memory cassette to extend the integrated memory can additionally be connected.

On the left side of the PLC, special adapter for analog inputs, Ethernet and serial communication (compatible with MODBUS) can be easily connection to any PC or laptop for high speed program  uploads and downloads along with monitoring.

Mitsubishi Electric introduces the FX3S Programmable Logic Controller-the new entry level model for the proven  FX3 series. Notable attributes of the FX3S PLC are its flexibility and expandability. it allows users to choose only the functionality necessary to perform a specific application, saving on hardware costs.
The FX3S series PLC provides full function PLC control, built-in high-speed inputs and outputs, and multiple, built-in communication ports. it also includes expansion options for communications, analog and temperature control. As part of the FX3 series, the FX3S can use many of the existing programming resources that are available for other FX3 series PLCs. This greatly reduces time and costs for system set up.
The FX3S PLC is designed to handle basic control tasks, such as simple positioning or analog, and temperature control operations. It excels in small, standalone applications that don't require complex control tasks.

High-speed operation 
The FX3S processes basic instruction in 0.21 us, which is fester by approximately 3 times compared with is predecessor, the FX1S. For users this means quicker program response and more accurate process performance as inputs, outputs and actions are processed and monitored more time per second.

Ample program capacity 
In total, the built-in maintenance free EEPROM of the FX3S can store up to 16,000 steps are reserved for the PLC program and up to 12,000 steps can be used for comments .
The CPU of the FX3S supports in common 116 different applied instructions also dedicated instruction for frequency inverter communication are supported.

Analog value processing 
The FX3S is also available with integrated analog inputs (FX3S-30M[]-20AD). Along with an optional analog values can then measured and processed with this model.

Built-in Positioning  control
The FX3S series comes with high speed counters (up to 60kHz) and pulse train outputs (for 2 axes and up to 100kHz). and pulse train outputs (for 2 axes and up to 100kHz). The high speed counters can be configured in a single or two phase input.
pulse train outputs can be configured to provide continuous pulse streams at different frequencies or a set quantity of pulses at a single frequency. Simple positioning solutions can be effectively managed this way without much hardware and programming effort.

Programming made easy 
The FX Family has a simple programming structure combining  Basic and Applied instructions. The Basic instructions common to all FX Family PLCs. Applied instructions provide the specialist control options such as data comparisons, PID and communications control, all of which are available on FX3S.
For the programming of the FX3S, GX Works2 is the first choice. This powerful, intuitive, and efficient programming tool reduces program development time and has an easy to use interface it is part of Mitsubishi Electric's integrated engineering environment iQ Works.

Compatibility with global standards
The FX3S conforms to the EC Directive and UL Standard, which make it to a product to trust. Even more flexibility is achieved       with the    choice between sink or source inputs.

FX3S-10MR/ES

Specifications

I/O points                  : Max 30
Adress range             : X0-X17/Y0-Y15 (octal)
Power supply            : 100-240V AC, 50/60 Hz or 24VDC
Program memory : 16,000 steps EEPROM (internal), exchangeable EEPROM memory cassette;program capacity is limited to 4,000 steps
Instruction Time: 0.21 us/basic instruction
Integrated digital inputs
  • Number of inputs : 6
  • Input Voltage       :  24V DC (+10%)
  • Input form           : sink/source
  • Response Time    : Approx. 10 ms
  • Isolation              : Photocoupler isolation
Integrated analog inputs

  • Number of inputs               :  -
  • Analog input Voltage         :  -
Integrated outputs 
  • Number of outputs            : 4
  • Switching voltage             : 240 V AC , ,30V DC (relay output), 5-30V DC (transistor output)
  • Output type/form              : Relay or transistor
  • Max load resistive            : 2a/point, max.8 A for 4 output points/common terminal(relay),     0.5A/point ;max 0.8a for 4 output points/common terminal (transistor)
  • Max load inductive          :  80VA (relay), 12W/point (at 24V DC); max.192W for 4 output points/common  terminal (transistor)
  • Response time                  : 10ms (relay), ,5 us (for Y000 and Y0010/0.2ms (for all other outputs) (transistor)
  • Isolation                           : Photocoupler Isolation
High-speed counters   : 21 total, with 16 1-phase (C235-C250) and 5 2-phase (C251-255)
Counting range            : -2, 147, 483,648-2,147,483,647
Service power supply  : 24V DC, 400mA
Environment               : 0-55C ambient temperature;5-9% relative humidity


FX3S-14MR/ES


Specifications

I/O points                  : Max 30
Adress range             : X0-X17/Y0-Y15 (octal)
Power supply            : 100-240V AC, 50/60 Hz or 24VDC
Program memory : 16,000 steps EEPROM (internal), exchangeable EEPROM memory cassette;program capacity is limited to 4,000 steps
Instruction Time: 0.21 us/basic instruction
Integrated digital inputs
  • Number of inputs : 8
  • Input Voltage       :  24V DC (+10%)
  • Input form           : sink/source
  • Response Time    : Approx. 10 ms
  • Isolation              : Photocoupler isolation
Integrated analog inputs

  • Number of inputs               :  -
  • Analog input Voltage         :  -
Integrated outputs 
  • Number of outputs            : 6
  • Switching voltage             : 240 V AC , ,30V DC (relay output), 5-30V DC (transistor output)
  • Output type/form              : Relay or transistor
  • Max load resistive            : 2a/point, max.8 A for 4 output points/common terminal(relay),     0.5A/point ;max 0.8a for 4 output points/common terminal (transistor)
  • Max load inductive          :  80VA (relay), 12W/point (at 24V DC); max.192W for 4 output points/common  terminal (transistor)
  • Response time                  : 10ms (relay), ,5 us (for Y000 and Y0010/0.2ms (for all other outputs) (transistor)
  • Isolation                           : Photocoupler Isolation
High-speed counters   : 21 total, with 16 1-phase (C235-C250) and 5 2-phase (C251-255)
Counting range            : -2, 147, 483,648-2,147,483,647
Service power supply  : 24V DC, 400mA
Environment               : 0-55C ambient temperature;5-9% relative humidity


FX3S-20MR/ES

Specifications

I/O points                  : Max 30
Adress range             : X0-X17/Y0-Y15 (octal)
Power supply            : 100-240V AC, 50/60 Hz or 24VDC
Program memory : 16,000 steps EEPROM (internal), exchangeable EEPROM memory cassette;program capacity is limited to 4,000 steps
Instruction Time: 0.21 us/basic instruction
Integrated digital inputs
  • Number of inputs : 12
  • Input Voltage       :  24V DC (+10%)
  • Input form           : sink/source
  • Response Time    : Approx. 10 ms
  • Isolation              : Photocoupler isolation
Integrated analog inputs

  • Number of inputs               :  -
  • Analog input Voltage         :  -
Integrated outputs 
  • Number of outputs            : 8
  • Switching voltage             : 240 V AC , ,30V DC (relay output), 5-30V DC (transistor output)
  • Output type/form              : Relay or transistor
  • Max load resistive            : 2a/point, max.8 A for 4 output points/common terminal(relay),     0.5A/point ;max 0.8a for 4 output points/common terminal (transistor)
  • Max load inductive          :  80VA (relay), 12W/point (at 24V DC); max.192W for 4 output points/common  terminal (transistor)
  • Response time                  : 10ms (relay), ,5 us (for Y000 and Y0010/0.2ms (for all other outputs) (transistor)
  • Isolation                           : Photocoupler Isolation
High-speed counters   : 21 total, with 16 1-phase (C235-C250) and 5 2-phase (C251-255)
Counting range            : -2, 147, 483,648-2,147,483,647
Service power supply  : 24V DC, 400mA
Environment               : 0-55C ambient temperature;5-9% relative humidity

FX3S-30MR/ES


Specifications

I/O points                  : Max 30
Adress range             : X0-X17/Y0-Y15 (octal)
Power supply            : 100-240V AC, 50/60 Hz or 24VDC
Program memory : 16,000 steps EEPROM (internal), exchangeable EEPROM memory cassette;program capacity is limited to 4,000 steps
Instruction Time: 0.21 us/basic instruction
Integrated digital inputs
  • Number of inputs : 16
  • Input Voltage       :  24V DC (+10%)
  • Input form           : sink/source
  • Response Time    : Approx. 10 ms
  • Isolation              : Photocoupler isolation
Integrated analog inputs

  • Number of inputs               :  -
  • Analog input Voltage         :  -
Integrated outputs 
  • Number of outputs            : 14
  • Switching voltage             : 240 V AC , ,30V DC (relay output), 5-30V DC (transistor output)
  • Output type/form              : Relay or transistor
  • Max load resistive            : 2a/point, max.8 A for 4 output points/common terminal(relay),     0.5A/point ;max 0.8a for 4 output points/common terminal (transistor)
  • Max load inductive          :  80VA (relay), 12W/point (at 24V DC); max.192W for 4 output points/common  terminal (transistor)
  • Response time                  : 10ms (relay), ,5 us (for Y000 and Y0010/0.2ms (for all other outputs) (transistor)
  • Isolation                           : Photocoupler Isolation
High-speed counters   : 21 total, with 16 1-phase (C235-C250) and 5 2-phase (C251-255)
Counting range            : -2, 147, 483,648-2,147,483,647
Service power supply  : 24V DC, 400mA
Environment               : 0-55C ambient temperature;5-9% relative humidity


FX3S-30MR/ES-2AD


Specifications

I/O points                  : Max 30
Adress range             : X0-X17/Y0-Y15 (octal)
Power supply            : 100-240V AC
Program memory : 16,000 steps EEPROM (internal), exchangeable EEPROM memory cassette;program capacity is limited to 4,000 steps
Instruction Time: 0.21 us/basic instruction
Integrated digital inputs
  • Number of inputs : 16
  • Input Voltage       :  24V DC (+10%)
  • Input form           : sink/source
  • Response Time    : Approx. 10 ms
  • Isolation              : Photocoupler isolation
Integrated analog inputs

  • Number of inputs               :  2
  • Analog input Voltage         :  0-10V DC
Integrated outputs 
  • Number of outputs            : 4
  • Switching voltage             : 240 V AC , ,30V DC (relay output), 5-30V DC (transistor output)
  • Output type/form              : Relay or transistor
  • Max load resistive            : 2a/point, max.8 A for 4 output points/common terminal(relay),     0.5A/point ;max 0.8a for 4 output points/common terminal (transistor)
  • Max load inductive          :  80VA (relay), 12W/point (at 24V DC); max.192W for 4 output points/common  terminal (transistor)
  • Response time                  : 10ms (relay), ,5 us (for Y000 and Y0010/0.2ms (for all other outputs) (transistor)
  • Isolation                           : Photocoupler Isolation
High-speed counters   : 21 total, with 16 1-phase (C235-C250) and 5 2-phase (C251-255)
Counting range            : -2, 147, 483,648-2,147,483,647
Service power supply  : 24V DC, 400mA
Environment               : 0-55C ambient temperature;5-9% relative humidity




Selasa, 30 Januari 2018

Mitsubishi FX3S : FX3S-10MR/ES,FX3S-10MT/ES,FX3S-10MT/ESS,FX3S-14MR/ES,FX3S-14MT/ES,FX3S-14MT/ESS,FX3S-20MR/ES,FX3S-20MT/ES,FX3S-20MT/ESS,FX3S-30MR/ES,FX3S-30MT/ES,FX3S-30MT/ESS,FX3S-30MR/ES-2AD,FX3S-30MT/ES-2AD,FX3S-30MT/ESS-2AD

FX3S
Controllable I/O: 10-30 points
(Main Unit I/O: 10/14/20/30 points

New possibilities
The newly released FX3S adds extra expandability to the high cost performance of the venerable entry-level FX1S. FX3S makes it possible to utilize analog, Ethernet  and MODBUS Functions even in small-scale systems

  • Basic controller for general applications 
  • High performance with minimal size.


  • 3rd generation compact PLC
  • High efficiency with morse speed, performance, memory, and new functions
  • Built-in high speed processing and positioning 
  • The FX3U can control a maximum of 256 connected I/O, and up to 384 points with CC-Link remote I/O.

Product Details 

All-in-one CPU, power supply and I/O. includes many upgraded features from the FX1S, Especially usage FX3 series ADP bus system and expansion boards (BD).

Fast Instruction Times
Basic instruction: 0.21 us / instructions (Contact Instructions) 
Applied Instructions: 0.5 us / instructions (MOV instructions)

Large Memory
4,000 steps of built-in program memory.
No battery . No maintenance

Applicable Standards
All products supports EN and UL/cUL standards.
Please consult with your local Mitsubishi representative
regarding FX3S shipping approvals.

Large Device Memory
Auxiliary Relays              : 1,536points
Timers                              : 138 points
Counters                           :   67 points
Data Registers                  :  3,000 points
Extension Registers          : 2,000 points

FX3S Series Programmable Controllers
User's Manual-Hardware Edition

AC Power supply common to 24 V DC sink and source input
FX3S-10MR/ES
FX3S-10MT/ES
FX3S-10MT/ESS
FX3S-14MR/ES
FX3S-14MT/ES
FX3S-14MT/ESS
FX3S-20MR/ES
FX3S-20MT/ES
FX3S-20MT/ESS
FX3S-30MR/ES
FX3S-30MT/ES
FX3S-30MT/ESS
FX3S-30MR/ES-2AD
FX3S-30MT/ES-2AD
FX3S-30MT/ESS-2AD

DC Power supply common to 24 V DC sink and source input
FX3S-10MR/DS
FX3S-10MT/DS
FX3S-10MT/DSS
FX3S-14MR/DS
FX3S-14MT/DS
FX3S-14MT/DSS
FX3S-20MR/DS
FX3S-20MT/DS
FX3S-20MT/DSS
FX3S-30MR/DS
FX3S-30MT/DS
FX3S-30MT/DSS