Spesifications

  • Manufacturer: Mitsubishi Electric 
  • RS-232C for communication special adapter (MODBUS corresponding) FX3U-232ADP-MB
  • Transmission standard : RS-232C compliant 
  • Insulation method : Photocoupler 
  • Transmission distance : Up to 15m 
  • External device connection method : D-SUB 9Pin connector (male) 
  • Communication system : Full-duplex bi-directional 
  • Communication procedure : · MODBUS communication (master or slave) - No-protocol communication , computer link (dedicated protocol format 1, dedicated protocol format 4) programming communication 
  • communication speed MODBUS communication : 300/600/1200/2400/4800/9600/19200/38400/57600/115200 (bps) corresponds to 38400/57600 / 115200bps from products manufactured on or after July 2012. (Serial number: 127 **** or later) 
  • No-protocol communication, computer link : 300/600/1200/2400/4800/9600/19200/38400 (Bps) FX3U, FX3UC is, later Ver.2.41, it supports 38400bps. 
  • Programming communication : 9600/19200/38400/57600/115200 (bps) 
  • Display (LED) : RD, SD, POWER 
  • O occupied points : 0 points (no relation to the maximum input and output points of the sequencer) 
  • Apply sequencer : [FX3S]
    V1.00 and later: corresponding to all the communication function
    [FX3G]
    V1.00 and later: communication functions other than the MODBUS communication to the corresponding
    V1.30 and later: corresponds to the MODBUS communication function
    [FX3U]
    V2.20 and later: other than MODBUS communication communication function to the corresponding of
    V2.40 and later: corresponds to the MODBUS communication function
    [FX3GC]
    V1.40 and later: corresponding to all the communication function
    [FX3UC]
    V1.00 and later: corresponds to the communication functions other than the MODBUS communication
    V2.40 and later: MODBUS corresponding to the communication function  
  • connection to FX3S is required FX3S-CNV-ADP.
    Connection to the FX3G is required FX3G-CNV-ADP.
    FX3U, connection to the FX3UC-32MT-LT (-2), you must have the function expansion board. 
  • mass : 0.08kg 
  • Power Specifications :   
  • Power supply : DC5V 30mA (internal power supply from the sequencer) 
  • Ambient temperature : 0 ~ 55 °C ····· operation, -25 ~ 75 °C ····· during storage 
  • Relative humidity : 5 ~ 95% RH (non-condensing) ...... operation 
  • Vibration resistance When the DIN rail mounting Frequency: 10 ~ 57Hz Half amplitude: 0.035mm X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Frequency: 57 ~ 150Hz Acceleration: 4.9m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Direct mounting at the time Frequency: 10 ~ 57Hz Half amplitude: 0.075mm X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Frequency: 57 ~ 150Hz Acceleration: 9.8m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Impact : 147m / s2, duration of action 11ms, X at half-sine pulse, Y, Z directions 3 times each 
  • Anti-noise : Noise voltage 1,000Vp-p, noise width 1μs, due to rising 1ns, cycle 30 ~ 100Hz of noise simulator 
  • Withstand voltage : D-SUB 9Pin connector and between the ground terminal of the basic unit: AC500V 1 minute 
  • Insulation resistance : D-SUB 9Pin connector and between the ground terminal of the basic unit: DC500V 5MΩ more in insulation resistance tester 
  • Use atmosphere : Corrosive, there is no flammable gas, conductive dust (dust) that is not terribly 
  • Advanced use : 2000m or less
    can not be used in the pressurized environment to more than atmospheric pressure. There is a possibility of failure. 
  • Shipping Weight: 1 Kg

Kamis, 01 Februari 2018

Mitsubishi FX3S : FX3U-4AD-PT-ADP,FX3U-4AD-TC-ADP,FX3U-4AD-PTW-ADP,FX3U-4AD-PNK-ADP,FX3U-4AD-ADP,FX3U-4DA-ADP,FX3U-3A-ADP,FX3U-232ADP-MB,FX3U-485ADP-MB,

Special Adapters
FX3U-ENET-ADP

Network
FX3U-ENET-ADP

FX3U-232ADP-MB

Communication
FX3U-232ADP-MB
FX3U-485ADP-MB

FX3U-4AD-ADP

Analog
FX3U-4AD-ADP
FX3U-4DA-ADP
FX3U-3A-ADP

FX3U-4AD-PNK-ADP

Temperature
FX3U-4AD-PT-ADP
FX3U-4AD-TC-ADP
FX3U-4AD-PTW-ADP
FX3U-4AD-PNK-ADP

FX3S-CNV-ADP

Interface
FX3S-CNV-ADP

Optional Equipment and Software
GOT
GOT1000(GT10/GT12/GT14/GT16)

Interface Converter
FX-232AWC-H

Software
GX Works2

Expansion Boards
FX3G-232-BD

Communication
FX3G-232BD
FX3G-422BD
FX3G-485BD

Analog Setpoint
FX3G-8AV-BD

Analog
FX3G-2AD-BD
FX3G-1DA-BD

FX3S Main Units
FX3S-10MR/ES
FX3S-10MT/ES
FX3S-10MT/ESS

FX3S-14MR/ES
FX3S-14MT/ES
FX3S-14MT/ESS

FX3S-20MR/ES
FX3S-20MT/ES
FX3S-20MT/ESS

FX3S-30MR/ES
FX3S-30MT/ES
FX3S-30MT/ESS

AC AC Power supply
D   DC Power supply
R   Relay Output
T1  Transistor Output(sink)
T2  Transistor Output(source)

Accessories
Memory Cassette
FX3G-EEPROM-32L

Mitsubishi FX3UC : FX3U-ENET-ADP,FX3U-232ADP-MB,FX3U-4AD-ADP,FX3U-4AD-PNK-AD,FX3U-ENET-ADP*1,FX3U-232ADP-MB,FX3U-4AD-ADP,FX3U-4AD-PT-ADP,FX3U-485ADP-MB,FX3U-4DA-ADP,FX3U-4AD-TC-ADP,FX3U-3A-ADP*2,FX3U-4AD-PTW-ADP,FX3U-4AD-PNK-ADP

Special Adapters

FX3U-ENET-ADP            
Network                             
FX3U-ENET-ADP*1         
                                            
                                                                                                                         
FX3U-232ADP-MB
Communication
FX3U-232ADP-MB
FX3U-485ADP-MB

FX3U-4AD-ADP
Analog
FX3U-4AD-ADP
FX3U-4DA-ADP
FX3U-3A-ADP*2

FX3U-4AD-PNK-ADP
Temperature
FX3U-4AD-PT-ADP
FX3U-4AD-TC-ADP
FX3U-4AD-PTW-ADP
FX3U-4AD-PNK-ADP

Data Logging  
FX3U-CF-ADP*2

FX3UC Main Units

FX3UC Main Units 16-96 I/O                               
FX3UC-16MT/D*                                                  
FX3UC-16MT/DSS                                                                            
FX3UC-16MR/DS-T                                               
FX3UC-16MR/D-T*    
                                                                                 
FX3UC-32MT/DSS
FX3UC-32MT/DSS

FX3UC-64MT/D*
FX3UC-64MT/DSS

FX3UC-96MT/D*
FX3UC-96MT/DSS

DC   Power Supply
D1   Input (sink)


D2   Input(sink/source)
R      Relay output
T1    Transistor output (sink)
T2    Transistor Outputs (source)

Optional Equipment and Software          
GOT                                                          
GOT1000                                                   
(GT10/GT12/GT14/GT16)
                       
Software
GX Developer
GX Works

Interface Converters
FX-USB-AW
FX-232AWC-H


Accessories
Memory Cassettes                                       
FX3U-FLROM-16                                      
FX3U-FLROM-64                                       
FX3U-FLROM-64L
FX3U-FLROM-1M*3

I/O Cable
General I/O Cable
FX-16E-500CAB-S(5m)

Connecting to Terminals Blocks
FX-16E-150CAB(1.5m)
FX-16E-300CAB(3m)
FX-16E-500CAB(5m)
FX-16E-150CAB-R(1.5m)
FX-16E-300CAB-R(3m)
FX-16E-500CAB-R(5m)

Special Function Modules*
 I/O Extension Blocks
Input Extension Blocks
FX2NC-16EX-T-DS
FX2NC-16EX-DS
FX2NC-32EX-DS

Output Extension
FX2NC-16EYR-T-DS
FX2NC-16EYT-DSS
FX2NC-32EYT-DSS

Power Supply Unit
FX3UC-1PS-5V

Interface Converter
FX2NC-CNV-IF

Special Function Blocks
Analog
FX3UC-4AD
FX3UC-4DA

High Speed Counter 
FX2NC-1HC
Analog               Positioning                   
FX0N-3A           FX2N-1PG-E               
FX2N-2AD        FX3U-1PG                   
FX3U-4AD        FX2N-10PG                               
FX2N-2DA        FX2N-1RM-E-SET      
FX3U-4DA        FX3U-20SSC-H 
FX2N-5A           FX2N-20GM
FX2N-8AD

Network
FX2N-32CCL
FX3U-16CCL-M*1
FX3U-64CCL
FX3U-ENET-L

Temperature
FX2N-2LC
FX3U-4LC

High Speed Control
FX2N-1HC
FX3U-2HC

Communication
FX2N-232IF


Unpowered Extension Blocks
Input /Output Extension Blocks                 
FX2N-8ER-ES/UL                                     
                                                                                                                       
Input Extension Blocks
FX2N-8EX-ES/UL
FX2N-8EX-UA1/UL
FX2N-16EX-ES/UL

Output Extension Blocks
FX2N-8EYR-ES/UL
FX2N-8EYT-ESS/UL
FX2N-16EYR-ES/UL
FX2N-16EYT-ESS/UL
FX2N-16EYS

Connectors Part                 
FX2C-I/O-CON                 
FX2C-I/O-CON-S              
FX2C-I/O-CON-SA           
                                            
                                            

Terminals Blocks
FX-16E-TB/UL
FX-16EYR-ES-TB/UL
FX-16EYS-ES-TB/UL
FX-16EYT-ESS-B/UL
FX-32E-TB/UL

Input Switches
FX2C-16SW-C
FX2C-16SW-TB

Battery
FX3U-32BL

Extension Cable                 
FX0N-30EC(30cm)          
FX0N-65EC(65cm)                                                      
                                                                                       
PLC Bus Connector                                     
FX2N-CNV-BC

Power Supply Cables
FX2NC-100MPCB(1m)
FX2NC-100BPCB(1m)


FX2NC-10BPCB1 (0.1m)

Mitsubishi FX3U : FX3U-232BD,FX3U-CNV-BD,FX3U-422BD,FX3U-485BD,FX3U-USB-BD,FX3U-8AV-BD, FX3U-ENET-ADP,FX3U-4ADP-PTW-ADP,FX3U-4HSX-ADP,FX3U-232ADP-MB,FX3U-4AD-ADP,FX3U-4HSX-ADP,FX3U-485ADP-MB,FX3U-4DA-ADP,FX3U-3A-ADP*,FX3U-ENET-ADP*1,FX3U-4AD-PT-ADP,FX3U-2HSY-ADP,FX3U-4AD-TC-ADP,FX3U-4AD-PTW-ADP,FX3U-CF-ADP*2,FX3U-4AD-PNK-ADP

Expansion Boards
FX3U-422-BD
                 
Communication        
FX3U-232BD
FX3U-422BD
FX3U-485BD  
FX3U-USB-BD

Interface 
FX3U-CNV-BD

Analog Setpoint
 FX3U-8AV-BD

Special Adapters                   
FX3U-ENET-ADP                  

Communication                       
FX3U-232ADP-MB                
FX3U-485ADP-MB                
                                                 

Network                                   
FX3U-ENET-ADP*1               
                                                
Data Logging                           
FX3U-CF-ADP*2                   

Special Adapters  
FX3U-4ADP-PTW-ADP 

Analog         
FX3U-4AD-ADP 
FX3U-4DA-ADP
FX3U-3A-ADP*2

Temperature
FX3U-4AD-PT-ADP
FX3U-4AD-TC-ADP
FX3U-4AD-PTW-ADP
FX3U-4AD-PNK-ADP

Special Adapters
FX3U-4HSX-ADP

High-Speed Counter
FX3U-4HSX-ADP

Positioning
FX3U-2HSY-ADP


FX3U Main Units
FX3U Main Units 16-128 I/O

FX3U-16MR/ES-A               FX3U-48MR/ES-A              FX3U-80MR/ES-A
FX3U-16MT/ES-A               FX3U-48MT/ES-A               FX3U-80MT/ES-A
FX3U-16MT/ESS                 FX3U-48MT/ESS                 FX3U-80MT/ESS
FX3U-16MR/DS                   FX3U-48MR/DS                  FX3U-80MR/DS
FX3U-16MT/DS                   FX3U-48MT/DS                   FX3U-80MT/DS
FX3U-16MT/DSS                 FX3U-48MT/DSS                 FX3U-80MT/DSS
FX3U-32MR/ES-A                FX3U-64MR/ES-A
FX3U-32MT/ES-A                FX3U-64MT/ES-A                FX3U-128MR/ES-A
FX3U-32MT/ESS                  FX3U-64MT/ESS                  FX3U-128MT/ES-A
FX3U-32MS/ES                    FX3U-64MS/ES                     FX3U-128MT/ESS
FX3U-32MR/DS                   FX3U-64MR/DS               
FX3U-32MT/DS                   FX3U-64MT/DS
FX3U-32MT/DSS                 FX3U-64MT/DSS
FX3U-32MR/UA1                 FX3U-64MR/UA1

AC Power Supply                 R    Relay Output
DC Power Supply                 T1  Transistor (sink)
D   Input (Sink/Source)         T2   Transistor(source)
E    Input                                TR   Triac output


Special Function Modules

I/O Extension Modules                                 
Powered Extension Units                               
Input/Output Extension Units                        
FX2N-32ER-ES/UL                                      
FX2N-32ET-ESS/UL                                    
FX2N-48ER-DS                                                                                                  
FX2N-48ER-ES/UL                                                                                            
FX2N-48ER-UA1/UL                                  
FX2N-48ET-DSS                                           
FX2N-48ET-ESS/UL

Unpowered Extension Blocks
Input Extension 
FX2N-8EX-ES/UL  
FX2N-8EX-UA1/UL    
FX2N-16EX-ES/UL  

Input/Output Extension Blocks


FX2N-8ER-ES/UL

Output Extension
FX2N-8EYR-ES/UL
FX2N-8EYT-ESS/UL
FX2N-16EYR-ES/UL
FX2N-16EYT-ESS/UL
FX2N-16EYS

Rabu, 31 Januari 2018

Serial Communication : FX3U-232-BD,FX3U-485-BD,FX3G-485-BD,FX3G-232-BD,FX2NC-232ADP,FX2NC-485ADP,FX3U-232ADP-MB,FX3U-485ADP-MB

For related system and data transfer with external equipment and third party devices, serial communication has long been the established connection method. Serial communication allows the FX Series to connect both efficiently and reliably with other PLCs, sensor, printers, and modems, etc. Multi drop networks , non-protocol communication, and remote maintenance are just some of the many uses.

Modbus
Both an open network and a serial communicator, Modbus-RTU allows FX3 series PLCs to interface with a wide range of equipment and devices. Using RS-485 and RS-232, the FX3U-485ADP-MD and FX3U-232ADP-MB expand the networking capabilities of the FX system while still supporting general communication with other FX systems, non-protocol devices, and serial modems. 
Modbus serial communication parameters and communication execution are setup easily within the ladder program using GX Works2 or GX Developer, and the FX Modbus Master uses the special ADPRW instruction to communicate with up to 16 Slave stations.

Serial Communication


FX3U-232-BD



FX3U-485-BD


FX3G-485-BD



FX3G-232-BD

FX2NC-232ADP



FX2NC-485ADP


Modbus



FX3U-232ADP-MB



FX3U-485ADP-MB


Communications Protocols

N:N Network
Connect up to 8 FX PLCs using N:N Networking to allow 
data exchange between each station.

Computer Link (Dedicated Protocol)
1:N Computer to PLC Communication with a network of up to 16 FX, A, and Q PLCs

1:1 RS-232 Communication Equipment to PLC When communicating over an RS-232 interface, the PC can communicate with one FX PLC.

Parallel Link
Auxiliary Relays (M) and Data Register (D) are update automatically between  two PLCs of the same series

Remote Maintenance
Using a modem connection, a PC an monitor/force devices and perform program upload/download to a PLC from remote locations

Non-Protocol Communication is possible between a PLC and any external equipment with an RS -232C or RS-485 (RS-422) interface