Rabu, 20 Maret 2019

FX3U-485ADP-MB

Spesifications

  • Manufacturer: Mitsubishi Electric 
  • FX3U-485ADP-MB
  • Transmission standard: RS-485 standard, conform to the RS-422 standard 
  • Insulation method:Photocoupler 
  • Transmission distance: The total length 500m or less
    (to the equipment to be connected FX2N-485-BD, FX1N- 485-BD, FX3U-485-BD, following the total length 50m if it contains a FX3G-485-BD) 
  • External device connection method: Europe terminal block 
  • Communication system: Half-duplex bi-directional 
  • Communication procedure: . MODBUS (master or slave) - No-protocol communication, computer link (dedicated protocol format 1, dedicated protocol format 4), parallel link and simple PC-to-PC link inverter communication 
  • communication speed MODBUS communication: 300/600/1200/2400/4800/9600/19200/38400/57600/115200 (bps)
    corresponds to 38400/57600 / 115200bps from products manufactured on or after July 2012. (Serial number: 127 **** or later) 
  • No-protocol, the computer link: 300/600/1200/2400/4800/9600/19200/38400 (Bps)
    FX3U, FX3UC is, later Ver.2.41, it supports 38400bps. 
  • Parallel link: 115200 (bps) 
  • Simple PC-to-PC link: 38400 (bps) 
  • Inverter communication: 4800/9600/19200/38400 (Bps)
    FX3U, FX3UC is, later Ver.2.41, it supports 38400bps. 
  • Display (LED): RD, SD, POWER 
  • O occupied points: 0 points (no relation to the maximum input and output points of the sequencer) 
  • Apply sequencer: [FX3S]
    V1.00 and later: corresponding to all the communication function 
  • [FX3G]
    V1.00 and later: MODBUS, corresponding to the communication functions other than the inverter communication
    V1.10 and later: inverter communication function to the corresponding
    V1.30 and later: in MODBUS communication function correspondence 
  • [FX3U]
    V2.20 and later: communication functions other than the MODBUS communication to the corresponding
    V2.40 and later: corresponds to the MODBUS communication function 
  • [FX3GC]
    V1.40 and later: corresponding to all the communication function 
  • [FX3UC]
    V1.00 and later: MODBUS communication communication function to the corresponding non-
    V2.40 and later: corresponds to the MODBUS communication function.
  • connection to FX3S is required FX3S-CNV-ADP. 
  • Connection to the FX3G is required FX3G-CNV-ADP. 
  • FX3U, connection to the FX3UC-32MT-LT (-2), you must have the function expansion board. 
  • mass: 0.08kg 
  • Power Specifications: 
  • Power supply: DC5V 20mA (internal power supply from the sequencer) 
  • Ambient temperature: 0 ~ 55 °C ..... operation, -25 ~ 75 °C ..... during storage 
  • Relative humidity: 5 ~ 95% RH (non-condensing) ...... operation 
  • Vibration resistance When the DIN rail mounting : Frequency: 10 ~ 57Hz: Half amplitude: 0.035mm X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • When the DIN rail mounting : Frequency: 57 ~ 150Hz: Acceleration: 4.9m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Direct mounting at the time : Frequency: 10 ~ 57Hz: Half amplitude: 0.075mm X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Direct mounting at the time : Frequency: 57 ~ 150Hz: Acceleration: 9.8m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Impact: 147m / s2, duration of action 11ms, X at half-sine pulse, Y, Z directions 3 times each 
  • Anti-noise: Noise voltage 1,000Vp-p, noise width 1μs, due to rising 1ns, cycle 30 ~ 100Hz of noise simulator 
  • Withstand voltage: External terminals and between the PLC main unit of the ground terminal: AC500V 1 minute 
  • Insulation resistance: External terminals and between the PLC main unit of the ground terminal: DC500V 5MΩ more in insulation resistance tester 
  • Use atmosphere: Corrosive, there is no flammable gas, conductive dust (dust) that is not terribly 
  • Advanced use: 2000m or less can not be used in the pressurized environment to more than atmospheric pressure. 
  • There is a possibility of failure. 
  • Shipping Weight : 1 Kg

Senin, 22 Oktober 2018

MITSUBISHI FX3U-485ADP-MB



Brand: MITSUBISHI 
Name: RS-485 communicationModel: FX3U-485ADP-MBRS-485 communication. Special communication adapter.Input / output form: relay output.
Output points: 16 points.
DC5V internal consumption current: 100mA.
DC24V internal consumption current: 125mA.
In order to extend the input output of the device.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256 MITSUBISHI FX3U-485ADP-MB.
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points FX3U-485ADP-MB Input / output type: transistor output (source).
Output points: 16 points.
Input and output points: 16 points.
Because all models of FX series are built in high speed counter,
So the high speed control can be realized by the simple procedure MITSUBISHI FX3U-485ADP-MB.
The input of the basic unit is built in the anti jitter filter,
One part as digital filter,
Sensitivity adjustment unit can reach 1ms.
Using high speed counter automatically adjusted to the minimum value.
Through the high cost of the built-in positioning function and the expansion function to increase the number of control axis.
Extended function expansion board and special adapter,
Data links and communication with external serial devices MITSUBISHI FX3U-485ADP-MB.
FX2N extension module.
The expansion module is an input and output expansion device of the power supply from the basic unit or the expansion unit,
Can choose the relay or crystal output models, to 8 points for the unit to connect MITSUBISHI RS-485 communication.
Can be extended to FX3GA/FX3G, FX3GE, FX3GC, as well as FX3U, FX3UC series,
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-1PS-5V MITSUBISHI RS-485 communication.
The number of connection points depends on the basic unit and the expansion unit. Max input / output points: 40 points.
Power supply voltage: 12-24VDC.
Input points: 24 points.
Output points: 16 points.
Output type: relay.
Power consumption (W): 18 MITSUBISHI RS-485 communication.
Weight (kg):0.65.
Size (WxHxD) mm:130x90x75.
Terminal row type standard machine with extended input output
Can also be less of a system with analog or communication, etc..
CPU, power supply, input and output integration.
Display module or function expansion board can be less installed.
In addition, you can also reduce the input output or special module.
Built in 8000 step EPROM memory.
No battery. Maintenance free.
Overseas oriented products meet all kinds of international standards.
FX1N series is a very powerful micro PLC, can be extended to up to 128 I/O points,
And can increase the special function module or the expansion board.
Communication aand data link function options make FX1N in the volume, communication and special function modules and other important applications is very perfect FX3U-485ADP-MB.
A PLC unit can output 2 100KHz pulses at the same time,
PLC is equipped wiith 7 special positioning instructions,
Including zero return, absolute position readout, absolute or relative drive, and special pulse output control MITSUBISHI FX3U-485ADP-MB

Kamis, 01 Februari 2018

Mitsubishi FX3S : FX3U-4AD-PT-ADP,FX3U-4AD-TC-ADP,FX3U-4AD-PTW-ADP,FX3U-4AD-PNK-ADP,FX3U-4AD-ADP,FX3U-4DA-ADP,FX3U-3A-ADP,FX3U-232ADP-MB,FX3U-485ADP-MB,

Special Adapters
FX3U-ENET-ADP

Network
FX3U-ENET-ADP

FX3U-232ADP-MB

Communication
FX3U-232ADP-MB
FX3U-485ADP-MB

FX3U-4AD-ADP

Analog
FX3U-4AD-ADP
FX3U-4DA-ADP
FX3U-3A-ADP

FX3U-4AD-PNK-ADP

Temperature
FX3U-4AD-PT-ADP
FX3U-4AD-TC-ADP
FX3U-4AD-PTW-ADP
FX3U-4AD-PNK-ADP

FX3S-CNV-ADP

Interface
FX3S-CNV-ADP

Optional Equipment and Software
GOT
GOT1000(GT10/GT12/GT14/GT16)

Interface Converter
FX-232AWC-H

Software
GX Works2

Expansion Boards
FX3G-232-BD

Communication
FX3G-232BD
FX3G-422BD
FX3G-485BD

Analog Setpoint
FX3G-8AV-BD

Analog
FX3G-2AD-BD
FX3G-1DA-BD

FX3S Main Units
FX3S-10MR/ES
FX3S-10MT/ES
FX3S-10MT/ESS

FX3S-14MR/ES
FX3S-14MT/ES
FX3S-14MT/ESS

FX3S-20MR/ES
FX3S-20MT/ES
FX3S-20MT/ESS

FX3S-30MR/ES
FX3S-30MT/ES
FX3S-30MT/ESS

AC AC Power supply
D   DC Power supply
R   Relay Output
T1  Transistor Output(sink)
T2  Transistor Output(source)

Accessories
Memory Cassette
FX3G-EEPROM-32L

Mitsubishi FX3GC : FX3U-4AD-PT-ADP,FX3U-4AD-TC-ADP,FX3U-4AD-PTW-ADP,FX3U-4AD-PNK-ADP,FX3U-4AD-ADP,FX3U-485ADP-MB,FX3U-4DA-ADP,FX3U-3A-ADP

Special Adapter
FX3U-ENET-ADP      

Network                                        
FX3U-ENET-ADP*                      
                                                                                                                     
FX3U-232ADP-MB    FX3U-485ADP-MB
Communication
FX3U-232ADP-MB
FX3U-485ADP-MB

FX3U-4AD-ADP
Analog
FX3U-4AD-ADP
FX3U-4DA-ADP
FX3U-3A-ADP


Temperature
FX3U-4AD-PT-ADP
FX3U-4AD-TC-ADP
FX3U-4AD-PTW-ADP
FX3U-4AD-PNK-ADP

FX3GC Main Units
FX3GC Main Unit 32 I/O

FX3GC-32MT/D
FX3GC-32MT/DSS

Optional Equipment and Software
GOT
GOT1000 (GT10/GT12/GT14/GT16)

Interface Converter
FX-232AWC-H

Software
GX Developer
GX Works2

Accessories                                          
I/O Cables                                            
General I/O cable                                
FX-16E-500CAB-S(5m)
                     
Connecting to Terminals Blocks
FX-16E-150CAB(1.5m)      FX-16E-150CAB-R(1.5m)
FX-16E-300CAB(3m)         FX-16E-300CAB-R(3m)
FX-16E-500CAB(5m)         FX-16E-500CAB-R(5m)


Special Function Models
I/O Extension Blocks             Power Supply Unit
Input Extension Blocks          FX3UC-1PS-5V
FX2NC-16EX-T-DS
FX2NC-16EX-DS                  Interface Converter
FX2NC-32EX-DS                  FX2NC-CNV-IF

Output Extension Blocks
FX2NC-16EYR-T-DS
FX2NC-16EYT-DSS
FX2NC-32EY-DSS

Special Function Blocks

FX3UC-4AD           

Analog                      
FX3U-4AD              
FX2NC-4DA

FX3U-4DA

Analog  
FX2N-2LC
FX3U-4AD
FX3U-2DA
FX3U-4DA
FX2N-5A
FX2N-8AD

Temperature
FX2N-2LC
FX3U-4LC
FX2N-4AD-TC
FX2N-4AD-PT

Network
FX2N-32CCL
FX3U-16CCL-M*
FX3U-64CCL

Connector Parts          
FX2C-I/O-CON           
FX2C-I/O-CON-S       
FX2C-I/O-CON-SA    

Terminals Blocks        
FX-16E-TB/UL
FX-16EYR-ES-TB/UL
FX-16EYS-ES-TB/UL
FX-16EYT-ESS-TB/UL
FX-32E-TB/UL

Input Switches
FX2C-16SW-C
FX2C-16SW-TB

Battery


FX3U-32BL
 

Extension Cable           
FX0N-30EC(30cm)      
FX0N-60EC(60cm)                                                 
                                                                             
PLC Bus Connector
FX2N-CNV-BC    

Power Supply Cables
FX2NC-100MPCB (1m)


FX2NC-100BPCB(1m)
 FX2NC-10BPCB(0.1m) 

Rabu, 31 Januari 2018

Serial Communication : FX3U-232-BD,FX3U-485-BD,FX3G-485-BD,FX3G-232-BD,FX2NC-232ADP,FX2NC-485ADP,FX3U-232ADP-MB,FX3U-485ADP-MB

For related system and data transfer with external equipment and third party devices, serial communication has long been the established connection method. Serial communication allows the FX Series to connect both efficiently and reliably with other PLCs, sensor, printers, and modems, etc. Multi drop networks , non-protocol communication, and remote maintenance are just some of the many uses.

Modbus
Both an open network and a serial communicator, Modbus-RTU allows FX3 series PLCs to interface with a wide range of equipment and devices. Using RS-485 and RS-232, the FX3U-485ADP-MD and FX3U-232ADP-MB expand the networking capabilities of the FX system while still supporting general communication with other FX systems, non-protocol devices, and serial modems. 
Modbus serial communication parameters and communication execution are setup easily within the ladder program using GX Works2 or GX Developer, and the FX Modbus Master uses the special ADPRW instruction to communicate with up to 16 Slave stations.

Serial Communication


FX3U-232-BD



FX3U-485-BD


FX3G-485-BD



FX3G-232-BD

FX2NC-232ADP



FX2NC-485ADP


Modbus



FX3U-232ADP-MB



FX3U-485ADP-MB


Communications Protocols

N:N Network
Connect up to 8 FX PLCs using N:N Networking to allow 
data exchange between each station.

Computer Link (Dedicated Protocol)
1:N Computer to PLC Communication with a network of up to 16 FX, A, and Q PLCs

1:1 RS-232 Communication Equipment to PLC When communicating over an RS-232 interface, the PC can communicate with one FX PLC.

Parallel Link
Auxiliary Relays (M) and Data Register (D) are update automatically between  two PLCs of the same series

Remote Maintenance
Using a modem connection, a PC an monitor/force devices and perform program upload/download to a PLC from remote locations

Non-Protocol Communication is possible between a PLC and any external equipment with an RS -232C or RS-485 (RS-422) interface