Spesifications

  • Manufacturer: Mitsubishi Electric 
  • Analogue output adapter FX3U-4DA-ADP
  • Analog output range Voltage output : DC0V ~ 10V (external load 5kΩ ~ 1MΩ) 
  • Current output : DC4mA ~ 20mA (or less external load 500Ω) 
  • Number of output channels : 4 channel 
  • Output characteristic: For each channel, you can set the output mode (voltage / current output). 
  • Digital input : 12bit binary 
  • resolution Voltage output : 2.5mV (10V × 1/4000) 
  • Current output : 4μA (16mA × 1/4000) 
  • Overall accuracy Voltage output : Ambient temperature 25 °C ± 5 °C: 0.5% ± with respect to full-scale 10V (± 50mV)
    ambient temperature 0 °C ~ 55 °C: ± 1.0 % for the full-scale 10V (± 100mV)
    external load resistance (Rs) is less than 5kΩ If, following the calculation amount will increase. (100mV will increase per Pasento 1)
    (47 × 100) ÷ (Rs Tasu 47) -0.9 (Pasento) 
  • Current output : Ambient temperature 25 °C ± 5 °C: 0.5% ± with respect to full-scale 16mA (± 80μA)
    ambient temperature 0 °C ~ 55 °C: full scale 16mA for ± 1.0% (± 160μA) 
  • D / A conversion time FX3U / FX3UC PLC : 200μs (every calculation cycle update of the data) 
  • FX3S / FX3G / FX3GC sequencer : 250μs (every calculation cycle update of the data) 
  • Insulation method : Analog output section and between the sequencer, insulated by photo-coupler is between the power supply and the analog output section, insulated by a DC / DC converter is between-each channel, non-isolated 
  • O occupied points : 0 points (no relation to the maximum input and output points of the sequencer) 
  • Apply sequencer : FX3S, FX3G, FX3U, FX3GC, FX3UC (FX3UC-32MT-LT since Ver.1.20)
    connection to the FX3S is required FX3S-CNV-ADP.
    Connection to the FX3G is required FX3G-CNV-ADP.
    Connection to the FX3U and FX3UC-32MT-LT (-2), you must have the function expansion board. 
  • mass : 0.1kg 
  • Power Specifications : -
  • Power supply :
    DC5V 15mA (internal power supply from the sequencer)
    DC24V Tasu 20 Pasento -15 Pasento 150MA (external power supply) 
  • Ambient temperature : 0 ~ 55 °C ····· -25 ~ 75 °C ····· during storage operations 
  • Relative humidity : 5 ~ 95% RH (non-condensing) ...... operation 
  • Vibration resistance When the DIN rail mounting- Frequency: 10 ~ 57Hz : Half amplitude: 0.035mm X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • When the DIN rail mounting- Frequency: 57 ~ 150Hz : Acceleration: 4.9m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Direct mounting at the time- Frequency: 10 ~ 57Hz : Half amplitude: 0.075mm X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Direct mounting at the time- Frequency: 57 ~ 150Hz : Acceleration: 9.8m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Impact : 147m / s2, duration of action 11ms, X at half-sine pulse, Y, Z directions 3 times each 
  • Anti-noise : Noise voltage 1,000Vp-p, noise width 1μs, due to rising 1ns, cycle 30 ~ 100Hz of noise simulator 
  • Withstand voltage : All terminals and between the ground terminal: AC500V 1 minute 
  • Insulation resistance : All terminals and between the ground terminal: DC500V 5MΩ more in insulation resistance tester 
  • Ground: Class D grounding (ground resistance: 100Ω or less) <common ground is not allowed with the high-voltage system>
    ground, please dedicated ground or shared ground. 
  • Use atmosphere : Corrosive, there is no flammable gas, conductive dust (dust) that is not terribly 
  • Advanced use : 2000m or less can not be used in the pressurized environment to more than atmospheric pressure. There is a possibility of failure. 
  • Shipping Weight: 1.1 Kg

Kamis, 01 Februari 2018

Mitsubishi FX3S : FX3U-4AD-PT-ADP,FX3U-4AD-TC-ADP,FX3U-4AD-PTW-ADP,FX3U-4AD-PNK-ADP,FX3U-4AD-ADP,FX3U-4DA-ADP,FX3U-3A-ADP,FX3U-232ADP-MB,FX3U-485ADP-MB,

Special Adapters
FX3U-ENET-ADP

Network
FX3U-ENET-ADP

FX3U-232ADP-MB

Communication
FX3U-232ADP-MB
FX3U-485ADP-MB

FX3U-4AD-ADP

Analog
FX3U-4AD-ADP
FX3U-4DA-ADP
FX3U-3A-ADP

FX3U-4AD-PNK-ADP

Temperature
FX3U-4AD-PT-ADP
FX3U-4AD-TC-ADP
FX3U-4AD-PTW-ADP
FX3U-4AD-PNK-ADP

FX3S-CNV-ADP

Interface
FX3S-CNV-ADP

Optional Equipment and Software
GOT
GOT1000(GT10/GT12/GT14/GT16)

Interface Converter
FX-232AWC-H

Software
GX Works2

Expansion Boards
FX3G-232-BD

Communication
FX3G-232BD
FX3G-422BD
FX3G-485BD

Analog Setpoint
FX3G-8AV-BD

Analog
FX3G-2AD-BD
FX3G-1DA-BD

FX3S Main Units
FX3S-10MR/ES
FX3S-10MT/ES
FX3S-10MT/ESS

FX3S-14MR/ES
FX3S-14MT/ES
FX3S-14MT/ESS

FX3S-20MR/ES
FX3S-20MT/ES
FX3S-20MT/ESS

FX3S-30MR/ES
FX3S-30MT/ES
FX3S-30MT/ESS

AC AC Power supply
D   DC Power supply
R   Relay Output
T1  Transistor Output(sink)
T2  Transistor Output(source)

Accessories
Memory Cassette
FX3G-EEPROM-32L

Mitsubishi FX3GC : FX3U-4AD-PT-ADP,FX3U-4AD-TC-ADP,FX3U-4AD-PTW-ADP,FX3U-4AD-PNK-ADP,FX3U-4AD-ADP,FX3U-485ADP-MB,FX3U-4DA-ADP,FX3U-3A-ADP

Special Adapter
FX3U-ENET-ADP      

Network                                        
FX3U-ENET-ADP*                      
                                                                                                                     
FX3U-232ADP-MB    FX3U-485ADP-MB
Communication
FX3U-232ADP-MB
FX3U-485ADP-MB

FX3U-4AD-ADP
Analog
FX3U-4AD-ADP
FX3U-4DA-ADP
FX3U-3A-ADP


Temperature
FX3U-4AD-PT-ADP
FX3U-4AD-TC-ADP
FX3U-4AD-PTW-ADP
FX3U-4AD-PNK-ADP

FX3GC Main Units
FX3GC Main Unit 32 I/O

FX3GC-32MT/D
FX3GC-32MT/DSS

Optional Equipment and Software
GOT
GOT1000 (GT10/GT12/GT14/GT16)

Interface Converter
FX-232AWC-H

Software
GX Developer
GX Works2

Accessories                                          
I/O Cables                                            
General I/O cable                                
FX-16E-500CAB-S(5m)
                     
Connecting to Terminals Blocks
FX-16E-150CAB(1.5m)      FX-16E-150CAB-R(1.5m)
FX-16E-300CAB(3m)         FX-16E-300CAB-R(3m)
FX-16E-500CAB(5m)         FX-16E-500CAB-R(5m)


Special Function Models
I/O Extension Blocks             Power Supply Unit
Input Extension Blocks          FX3UC-1PS-5V
FX2NC-16EX-T-DS
FX2NC-16EX-DS                  Interface Converter
FX2NC-32EX-DS                  FX2NC-CNV-IF

Output Extension Blocks
FX2NC-16EYR-T-DS
FX2NC-16EYT-DSS
FX2NC-32EY-DSS

Special Function Blocks

FX3UC-4AD           

Analog                      
FX3U-4AD              
FX2NC-4DA

FX3U-4DA

Analog  
FX2N-2LC
FX3U-4AD
FX3U-2DA
FX3U-4DA
FX2N-5A
FX2N-8AD

Temperature
FX2N-2LC
FX3U-4LC
FX2N-4AD-TC
FX2N-4AD-PT

Network
FX2N-32CCL
FX3U-16CCL-M*
FX3U-64CCL

Connector Parts          
FX2C-I/O-CON           
FX2C-I/O-CON-S       
FX2C-I/O-CON-SA    

Terminals Blocks        
FX-16E-TB/UL
FX-16EYR-ES-TB/UL
FX-16EYS-ES-TB/UL
FX-16EYT-ESS-TB/UL
FX-32E-TB/UL

Input Switches
FX2C-16SW-C
FX2C-16SW-TB

Battery


FX3U-32BL
 

Extension Cable           
FX0N-30EC(30cm)      
FX0N-60EC(60cm)                                                 
                                                                             
PLC Bus Connector
FX2N-CNV-BC    

Power Supply Cables
FX2NC-100MPCB (1m)


FX2NC-100BPCB(1m)
 FX2NC-10BPCB(0.1m) 

Mitsubishi FX3U : FX3U-232BD,FX3U-CNV-BD,FX3U-422BD,FX3U-485BD,FX3U-USB-BD,FX3U-8AV-BD, FX3U-ENET-ADP,FX3U-4ADP-PTW-ADP,FX3U-4HSX-ADP,FX3U-232ADP-MB,FX3U-4AD-ADP,FX3U-4HSX-ADP,FX3U-485ADP-MB,FX3U-4DA-ADP,FX3U-3A-ADP*,FX3U-ENET-ADP*1,FX3U-4AD-PT-ADP,FX3U-2HSY-ADP,FX3U-4AD-TC-ADP,FX3U-4AD-PTW-ADP,FX3U-CF-ADP*2,FX3U-4AD-PNK-ADP

Expansion Boards
FX3U-422-BD
                 
Communication        
FX3U-232BD
FX3U-422BD
FX3U-485BD  
FX3U-USB-BD

Interface 
FX3U-CNV-BD

Analog Setpoint
 FX3U-8AV-BD

Special Adapters                   
FX3U-ENET-ADP                  

Communication                       
FX3U-232ADP-MB                
FX3U-485ADP-MB                
                                                 

Network                                   
FX3U-ENET-ADP*1               
                                                
Data Logging                           
FX3U-CF-ADP*2                   

Special Adapters  
FX3U-4ADP-PTW-ADP 

Analog         
FX3U-4AD-ADP 
FX3U-4DA-ADP
FX3U-3A-ADP*2

Temperature
FX3U-4AD-PT-ADP
FX3U-4AD-TC-ADP
FX3U-4AD-PTW-ADP
FX3U-4AD-PNK-ADP

Special Adapters
FX3U-4HSX-ADP

High-Speed Counter
FX3U-4HSX-ADP

Positioning
FX3U-2HSY-ADP


FX3U Main Units
FX3U Main Units 16-128 I/O

FX3U-16MR/ES-A               FX3U-48MR/ES-A              FX3U-80MR/ES-A
FX3U-16MT/ES-A               FX3U-48MT/ES-A               FX3U-80MT/ES-A
FX3U-16MT/ESS                 FX3U-48MT/ESS                 FX3U-80MT/ESS
FX3U-16MR/DS                   FX3U-48MR/DS                  FX3U-80MR/DS
FX3U-16MT/DS                   FX3U-48MT/DS                   FX3U-80MT/DS
FX3U-16MT/DSS                 FX3U-48MT/DSS                 FX3U-80MT/DSS
FX3U-32MR/ES-A                FX3U-64MR/ES-A
FX3U-32MT/ES-A                FX3U-64MT/ES-A                FX3U-128MR/ES-A
FX3U-32MT/ESS                  FX3U-64MT/ESS                  FX3U-128MT/ES-A
FX3U-32MS/ES                    FX3U-64MS/ES                     FX3U-128MT/ESS
FX3U-32MR/DS                   FX3U-64MR/DS               
FX3U-32MT/DS                   FX3U-64MT/DS
FX3U-32MT/DSS                 FX3U-64MT/DSS
FX3U-32MR/UA1                 FX3U-64MR/UA1

AC Power Supply                 R    Relay Output
DC Power Supply                 T1  Transistor (sink)
D   Input (Sink/Source)         T2   Transistor(source)
E    Input                                TR   Triac output


Special Function Modules

I/O Extension Modules                                 
Powered Extension Units                               
Input/Output Extension Units                        
FX2N-32ER-ES/UL                                      
FX2N-32ET-ESS/UL                                    
FX2N-48ER-DS                                                                                                  
FX2N-48ER-ES/UL                                                                                            
FX2N-48ER-UA1/UL                                  
FX2N-48ET-DSS                                           
FX2N-48ET-ESS/UL

Unpowered Extension Blocks
Input Extension 
FX2N-8EX-ES/UL  
FX2N-8EX-UA1/UL    
FX2N-16EX-ES/UL  

Input/Output Extension Blocks


FX2N-8ER-ES/UL

Output Extension
FX2N-8EYR-ES/UL
FX2N-8EYT-ESS/UL
FX2N-16EYR-ES/UL
FX2N-16EYT-ESS/UL
FX2N-16EYS

Rabu, 31 Januari 2018

Analog Control : FX1N-1DA-BD, FX3G-1DA-BD,FX2N-2DA,FX0N-3A, FX3U-3A-ADP,FX2N-4DA, FX3U-4DA, FX2NC-4DA, FX3U-4DA-ADP,FX2N-5A,FX2N-8AD,FX1N-2AD-BD, FX3G-2AD-BD, FX2N-2AD, FX0N-3A, FX3U-3A-ADP,FX2N-4AD, FX3U-4AD, FX3U-4LC, FX2NC-4AD, FX3U-4AD-ADP,FX3UC-4AD, FX2N-5A,FX2N-8AD,FX2N-2LC,

Analog Modules
Analog Output  1ch : FX1N-1DA-BD, FX3G-1DA-BD
                          2ch : FX2N-2DA
                          3ch : FX0N-3A, FX3U-3A-ADP
                          4ch : FX2N-4DA, FX3U-4DA, FX2NC-4DA, FX3U-4DA-ADP
                          5ch : FX2N-5A
                          8ch : FX2N-8AD

Analog Input     2ch : FX1N-2AD-BD, FX3G-2AD-BD, FX2N-2AD
                          3ch : FX0N-3A, FX3U-3A-ADP
                          4ch : FX2N-4AD, FX3U-4AD, FX3U-4LC, FX2NC-4AD, FX3U-4AD-ADP,
                                   FX3UC-4AD
                          5ch : FX2N-5A
                          8ch : FX2N-8AD

Temperature Input 2ch : FX2N-2LC
                              4ch : FX2N-4AD-TC, FX2N-4AD-PT, FX3U-4LC, FX3U-4AD-TC-ADP,
                                       FX3U-4AD-PT-ADP, FX3U-4AD-PTW-ADP, FX3U-4AD-PNK-ADP,
                              5ch : FX2N-5A
                              8ch : FX2N-8AD