JUAL OMRON CJ2M-CPU31

Since 2001, CJ1M-series PLCs are in control of a wide variety of applications worldwide. The accumulated experience and advancements in technology now result in CJ2M; fully compatible, yet fully new.

General Specifications

ItemCJ2M-
CPU1[]CPU3[]
EnclosureMounted in a panel
GroundingLess than 100 Ω
CPU Unit Dimensions90 mm × 75 mm × 31 mm90 mm × 75 mm × 62 mm
Weight130 g or less190 g or less *
Current Consumption5 VDC, 0.5 A5 VDC, 0.7 A
Operation 
Environment
Ambient Operating Temperature0 to 55 °C
Ambient Operating Humidity10% to 90% (with no condensation)
AtmosphereMust be free from corrosive gases.
Ambient Storage Temperature- 20 to 70 °C (excluding battery)
Altitude2,000 m or less
Pollution Degree2 or less: Conforms to JIS B3502 and IEC 61131-2.
Noise Immunity2 kV on power supply line (Conforms to IEC 61000-4-4.)
Overvoltage CategoryCategory II: Conforms to JIS B3502 and IEC 61131-2.
EMC Immunity LevelZone B
Vibration ResistanceConforms to IEC60068-2-6 
5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz 
Acceleration of 9.8 m/s2 for 100 min in X, Y, and Z directions 
(10 sweeps of 10 min each = 100 min total)
Shock ResistanceConforms to IEC60068-2-27 
147 m/s2, 3 times in X, Y, and Z directions (100 m/s2 for Relay 
Output Units)
BatteryLife5 years at 25 °C
ModelCJ1W-BAT01
Applicable StandardsConforms to cULus, NK, LR, and EC Directives.

Performance Specifications

ItemsCJ2M-
CPU11/31CPU12/32CPU13/33CPU14/34CPU15/35
User Memory5K steps10K steps20K steps30K steps60K steps
I/O Bits2,560 bits
Proc- 
essing 
Speed
Overhead Processing TimeNormal Mode: 
CJ2M-CPU3[]: 270 μs * 
CJ2M-CPU1[]: 160 μs * 
* The following time must be added when using EtherNet/IP tag data links for the CJ2M-CPU3[]. 
100 μs + (Number of words transferred × 1.8 μs) 
The following time must be added when using Pulse I/O Modules with a CJ2M CPU Unit: 
10 μs × Number of Pulse I/O Modules
Execution TimeBasic Instructions: 0.04 μs min. 
Special Instructions: 0.06 μs min.
Inter-
rupts
I/O Interrupts and External InterruptsInterrupt task startup time: 31 μs 
Return time to cyclic task: 10 μs
Scheduled InterruptsMinimum time interval: 0.4 ms (set in 0.1 ms increments)
Interrupt task startup time: 30 μs 
Return time to cyclic task: 11 μs
Maximum Number of Connectable UnitsTotal per CPU Rack or Expansion Rack: 10 Units max.; 
Total per PLC: 40 Units max.
Basic I/O UnitsNo limit 
However, a maximum of two CJ1W-INT01 Interrupt Input Units can be mounted.
Special I/O UnitsUnits for up to 96 unit numbers can be mounted. (Unit numbers run from 0 to 95. Units are allocated between 1 and 8 unit numbers.)
CPU Bus UnitsCJ2M-CPU3[]: 15 Units max. 
CJ2M-CPU1[]: 16 Units max.
Pulse I/O Modules2 Units max. * 
* Supported only by CJ2M CPU Units with unit version 2.0 or later. A Pulse I/O Module must be mounted.
Slots for which interrupts can be usedSlots 0 to 4 on CPU Rack
Maximum Number of Expansion Racks3 max.
CIO AreaI/O Area2,560 bits (160 words): Words CIO 0000 to CIO 0159
Link Area3,200 bits (200 words): Words CIO 1000 to CIO 1199
CPU Bus Unit Area6,400 bits (400 words): Words CIO 1500 to CIO 1899
Special I/O Unit Area15,360 bits (960 words): Words CIO 2000 to CIO 2959
Pulse I/O Area20 inputs, 12 outputs (CIO 2960 to CIO 2963)
Serial PLC Link Words1,440 bits (90 words): Words CIO 3100 to CIO 3189
DeviceNet Area9,600 bits (600 words): Words CIO 3200 to CIO 3799
Internal I/O Area3,200 bits (200 words): Words CIO 1300 to CIO 1499 (Cannot be used for external I/O.) 
37,504 bits (2,344 words): Words CIO 3800 to CIO 6143 (Cannot be used for external I/O.)
Work Area8,192 bits (512 words): Words W000 to W511 (Cannot be used for external I/O.)
Holding Area8,192 bits (512 words): Words H000 to H511 
Bits in this area maintain their ON/OFF status when PLC is turned OFF or operating mode is changed. 
Words H512 to H1535: These words can be used only for function blocks. They can be used only for function block instances (i.e., they are allocated only for internal variables in function blocks).
Auxiliary AreaRead-only: 31,744 bits (1,984 words) 
7,168 bits (448 words): Words A0 to A447 
24,576 bits (1,536 words): Words A10000 to A11535 * 
Read/write: 16,384 bits (1,024 words) in words A448 to A1471 * 
* A960 to A1471 and A10000 to A11535 cannot be accessed by CPU Bus Units, Special I/O Units, PTs, and Support Software that do not specifically support the CJ2 CPU Units.
Temporary Area16 bits: TR0 to TR15
Timer Area4,096 timer numbers (T0000 to T4095 (separate from counters))
Counter Area4,096 counter numbers (C0000 to C4095 (separate from timers))
DM Area32k words * 
DM Area words for Special I/O Units: D20000 to D29599 (100 words × 96 Units) 
DM Area words for CPU Bus Units: D30000 to D31599 (100 words × 16 Units) 
* Bits in the EM Area can be addressed either by bit or by word. These bits cannot be addressed by CPU Bus Units, Special I/O Units, PTs, and Support Software that do not specifically support the CJ2 CPU Units.
EM Area32k words/bank × 4 banks max.: E00_00000 to E3_32767 max. * 
* Bits in the EM Area can be addressed either by bit or by word. These bits cannot be addressed by CPU Bus Units, Special I/O Units, PTs, and Support Software that do not specifically support the CJ2 CPU Units.
32K words × 1 bank32K words × 4 banks
Force-S/R Enabled Banks *1Bank 0 hexBank 0 to 3 hex
Index RegistersIR0 to IR15 
These are special registers for storing PLC memory addresses for indirect addressing. (Index Registers can be set so that they are unique in each task or so that they are shared by all tasks.)
Cyclic Task Flag Area128 flags
Memory Card128 MB, 256 MB, or 512 MB
Operating ModesPROGRAM Mode: Programs are not executed. Preparations can be executed prior to program execution in this mode. 
MONITOR Mode: Programs are executed, and some operations, such as online editing, and changes to present values in I/O memory, are enabled in this mode. 
RUN Mode: Programs are executed. This is the normal operating mode.
Execution ModeNormal Mode
Programming LanguagesLadder Logic (LD), 
Sequential Function Charts (SFC), 
Structured Text (ST), and 
Instruction Lists (IL)
Function 
Blocks
Maximum number of definitions2562,048
Maximum number of instances2562,048
FB Program Area20K steps
TasksType of TasksCyclic tasks 
Interrupt tasks (Power OFF interrupt tasks, scheduled interrupt tasks, I/O interrupt tasks, and external interrupt tasks, and input interrupt tasks *2)
Number of TasksCyclic tasks: 128 
Interrupt tasks: 256 
(Interrupt tasks can be defined as cyclic tasks to create extra cyclic tasks. Therefore, the total number of cyclic tasks is actually 384 max.)
Symbols 
(Varia- 
bles)
Type of SymbolsLocal symbols: Can be used only within a single task in the PLC. 
Global symbols: Can be used in all tasks in the PLC. 
Network symbols (tags) *: I/O memory in the CPU Unit can be externally accessed using symbols, depending on parameter settings. 
* Supported only by the CJ2M-CPU3[].
Data Type of SymbolsBOOL (bit) 
UINT (one-word unsigned binary) 
UDINT (two-word unsigned binary) 
ULINT (four-word unsigned binary) 
INT (one-word signed binary) 
DINT (two-word signed binary) 
LINT (four-word signed binary) 
UINT BCD (one-word unsigned BCD) *3 
UDINT BCD (two-word unsigned BCD) *3 
ULINT BCD (four-word unsigned BCD) *3 
REAL (two-word floating-point) 
LREAL (four-word floating-point) 
CHANNEL (word) *3 
NUMBER (constant or number) *3 
WORD (one-word hexadecimal) 
DWORD (two-word hexadecimal) 
LWORD (four-word hexadecimal) 
STRING (1 to 255 ASCII characters) 
TIMER (timer) *4 
COUNTER (counter) *4 
User defined data types (data structures)
Maximum Size of Symbol32k words
Array Symbols (Array Variables)One-dimensional arrays
Number of Array Elements32,000 elements max.
Number of Registrable Network Symbols (Tags) *52,000 max.
Length of Network Symbol (Tag) Name *5255 bytes max.
Encoding of Network Symbols (Tags) *5UTF-8
Data 
Tracing
Memory Capacity8,000 words 
(The EM Area can be specified from the CX-Programmer to use up to 32K words multiplied by the number of banks supported by the CPU Unit model.)
Number of SamplingsBits = 31, one-word data =16, two-word data = 8, four-word data = 4
Sampling Cycle1 to 2,550 ms (Unit: 1 ms)
Trigger ConditionsON/OFF of specified bit 
Data comparison of specified word 
Data size: 1 word, 2 words, 4 words 
Comparison Method: Equals (=), Greater Than (>), Greater Than or Equals (≥), Less Than (<), Less Than or Equals (≤), Not Equal (≠)
Delay Value- 32,768 to +32,767 ms
File MemoryMemory Card (128, 256, or 512 Mbytes) (Use the Memory Cards provided by OMRON.) 
EM file memory (Part of the EM Area can be converted for use as file memory.)
Source/ 
Comment
Memory
Function block program memory, comment file, program index file, symbol tablesCapacity: 1 Mbytes
Commu- 
nications
Logical Ports for 
Communications
Logical Ports8 ports (Used for SEND, RECV, CMND, PMCR, TXDU, and RXDU instructions.)
Extended 
Logical Ports
64 ports (Used for SEND2, RECV2, CMND2, and PMCR2 instructions.)
CIP 
Communications 
Specification
Class 3 
(Connection 
Type)
Number of connections: 64
UCMM (Non- 
connection 
Type)
Maximum number of clients that can communicate at the same time: 32 
Maximum number of servers that can communicate at the same time: 40
Peripheral (USB) PortUSB 2.0-compliant B-type connector
Baud Rate12 Mbps max.
Transmission Distance5 m max.
Serial PortCJ2M-CPU1[] interface: Conforms to EIA RS-232C. 
CJ2M-CPU3[]: No serial ports with default system 
One of the following Serial Option Boards can be mounted. 
CP1W-CIF01 RS-232C Option Board 
CP1W-CIF11 RS-422A/485 Option Board (not isolated, max. transmission distance: 50 m) 
CP1W-CIF12 RS-422A/485 Option Board (isolated, max. transmission distance: 500 m)
Communications MethodHalf-duplex
Synchronization MethodStart-stop
Baud Rate0.3, 0.6, 1.2, 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, or 115.2 (kbps)
Transmission Distance15 m max.
EtherNet/IP Port *6-
Trans- 
mission 
Specifi- 
cations
Media Access 
Method
CSMA/CD
ModulationBaseband
Transmission 
Paths
Star
Baud Rate100 Mbps (100Base-TX)
Transmission 
Media
Shielded twisted-pair (STP) cable; Categories: 5, 5e
Transmission 
Distance
100 m (between ethernet switch and node)
Number of 
Cascade 
Connections
No restrictions if ethernet switch is used.
Commu- 
nications
Specifi- 
cations
CIP 
Communications: 
Tag Data Links
Number of 
Connections
32
Packet Interval 
(Refresh period)
1 to 10,000 ms (Unit: 0.5 ms) 
Can be set for each connection. (Data will be refreshed at the set interval, regardless of the number of nodes.)
Permissible 
Communications
Band
3,000 packets per second *7
Number of 
Registerable Tag
32
Type of TagsCIO, DM, EM, HR, WR, and Network symboles
Number of Tags 
per Connection
8 (Seven tags if PLC status is included in the segment.)
Maximum Link 
Data Size per 
Node (total 
size of all tags)
640 words
Maximum Data 
Size per 
Connection
640 words *8 (Data is synchronized within each connection.)
Number of 
Registrable Tag 
Set
32 (1 connection = 1 segment)
Maximum Tag 
Set Size
640 words *8 (One word is used when PLC status is included in the segment.)
Maximum 
Number of Tags 
Refreshable in a 
Single Cycle of 
CPU Unit *9
Output/send (CPU Unit to EtherNet/IP): 32 
Input/receive (EtherNet/IP to CPU Unit): 32
Data Size 
Refreshable in a 
Single Cycle of 
CPU Unit *9
Output/send (CPU to EtherNet/IP): 640 words 
Input/receive (EtherNet/IP to CPU): 640 words
Change of Tag 
Data Link 
Parameter 
Settings during 
Operation
OK *10
Multi-cast 
Packet Filter 
*11
OK
CIP 
Communications: 
Explicit Messages
-
Class 3 
(Connection 
Type)
Number of connections: 128
UCMM (Non- 
connection 
Type)
Maximum number of clients that can communicate at the same time: 16 
Maximum number of servers that can communicate at the same time: 16
CIP RoutingOK (CIP routing is enabled for the following remote Units: CJ1W-EIP21, CJ2H-CPU6[]-EIP, CJ2M-CPU3[], and CS1W-EIP21.)
FINS 
Communications
-
FINS/UDPOK
FINS/TCP16 connections max.
EtherNet/IP 
Conformance Test
Conforms to A5.
EtherNet/IP 
Interface
10Base-T/100Base-TX 
Auto Negotiation/Fixed Setting