  • Manufacturer : Mitsubishi Electric
  • Q13UDVCPU
  • Universal model High speed type QCPU Q13UDVCPU
  • control method : Stored program iteration operation 
  • Input / output control method : Refresh method (Direct access input / output possible by specifying direct access input / output (DX, DY)) 
  • Programming language Sequence control language : Relay symbol word, logic symbolic word, MELSAP 3 (SFC), MELSAP-L, function block, structured text (ST) 
  • processing speed Sequence instructions LD X 0 : 1.9 ns 
  • MOV D 0 D 1 : 3.9 ns 
  • Constant scan : 0.5 - 2000 ms (Can be set in 0.1 ms increments) 
  • Program capacity : 130K steps (520K bytes) 
  • Memory capacity:-
  • Program memory (drive 0) : 520 KB 
  • Memory card (SD) (Drive 2) : Installed SD memory card (SD / SDHC) capacity (32 GB maximum) 
  • Standard RAM (Drive 3)- When the extended SRAM cassette is not used : 1024 KB 
  • Standard RAM (Drive 3)- When using extended SRAM cassette : Capacity when extended SRAM cassette is not used + Capacity of extended SRAM cassette (Extended SRAM cassette can be up to 8 Mbytes) 
  • Standard ROM (Drive 4) : 2051 KB 
  • CPU shared memory- QCPU standard area : 8 KB 
  • CPU shared memory- High speed communication area between multiple CPUs : 32 KB 
  • Maximum number of stored files:-
  • Program memory : 252 books 
  • Memory Card (SD)- SD : Root folder: Up to 512 subdirectories: Maximum 65534 
  • Memory Card (SD)- SDHC : Root folder: Maximum 65535 books Subdirectory: Up to 65534 books 
  • Standard RAM : 323 books 
  • Standard ROM : 256 
  • Intelligent functional unit Parameter Maximum setting number-Initial setting : 4096 pieces 
  • Intelligent functional unit Parameter Maximum setting number-refresh : 2048 pieces 
  • Number of input / output devices : 8192 points (X / Y 0 to 1 FFF) 
  • Number of input / output points : 4096 points (X / Y 0 to FFF) 
  • Number of device points:-
  • Internal relay [M] : Default 28672 points (M0 to 28671) (changeable) 
  • Latch relay [L] : Default 8192 points (L0 to 8191) (changeable) 
  • Link relay [B] : Default 8192 points (B 0 to 1 FFF) (changeable) 
  • Timer [T] : Default 2048 points (T 0 to 2047) (Shared with low-speed timer / high-speed timer) (Changeable) Low-speed timer / high-speed timer specified by instruction Set the measurement unit of low-speed timer / high-speed timer by parameter (low-speed timer: 1 to 1000 ms , 1 ms increment, default 100 ms) (High-speed timer: 0.01 to 100 ms, 0.01 ms increments, default 10.0 ms) 
  • Integration timer [ST] : Default 0 point (Shared with low speed integration timer / high speed integration timer) (Changeable) Low speed integration timer / high speed integration timer is specified by instruction Set the measurement unit of low speed integration timer / high speed integration timer by parameter (low speed integration timer: 1 ~ 1000 ms, 1 ms increment, default 100 ms) (High-speed integration timer: 0.01 to 100 ms, 0.01 ms increments, default 10.0 ms) 
  • Counter [C] : Normal counter: default 1024 points (C 0 ~ 1023) (changeable) 
  • Data register [D] : Default 41984 points (D 0 to 41983) (changeable) 
  • Extended data register [D] : Default 0 point (changeable) 
  • Link register [W] : Default 8192 points (W 0 to 1 FFF) (changeable) 
  • Extended link register [W] : Default 0 point (changeable) 
  • Annunciator [F] : Default 2048 points (F 0 to 2047) (changeable) 
  • Edge relay [V] : Default 2048 points (V 0 to 2047) (changeable) 
  • File register [R]- When the extended SRAM cassette is not used : 32768 points (R 0 ~ 32767) Up to 524288 points can be used by block switching 
  • File register [R]- When using Q4 MCA - 1 MBS : 32768 points (R 0 ~ 32767) Up to 1048576 points can be used by block changeover 
  • File register [R]- When using Q4 MCA - 2 MBS : 32768 points (R 0 ~ 32767) Up to 1572864 points can be used by block switching 
  • File register [R]- When using Q4 MCA - 4 MBS : 32768 points (R 0 ~ 32767) Up to 2621440 points can be used by block switching 
  • File register [R]- When using Q4 MCA - 8 MBS : 32768 points (R 0 ~ 32767) Up to 4718592 points can be used by block changeover 
  • File register [ZR]- When the extended SRAM cassette is not used : 524288 points (ZR 0 to 524287) No block switching required 
  • File register [ZR]- When using Q4 MCA - 1 MBS : 1048576 points (ZR 0 to 1048575) No block switching required 
  • File register [ZR]- When using Q4 MCA - 2 MBS : 1572864 points (ZR 0 to 1572863) Block switching not required 
  • File register [ZR]- When using Q4 MCA - 4 MBS : 2621440 points (ZR 0 to 2621439) Block switching not required 
  • File register [ZR]- When using Q4 MCA - 8 MBS : 4718592 points (ZR 0 to 4718591) No block switching required 
  • Link special relay [SB] : Default 2048 points (SB 0 to 7 FF) (changeable) 
  • Link special register [SW] : Default 2048 points (SW 0 to 7 FF) (changeable) 
  • Step relay [S] : Default 8192 points (S0 to 8191) (changeable) 
  • Index register / general operation register [Z] : Up to 20 points (Z 0 ~ 19) 
  • Index register [Z] (when ZR device 32-bit qualifier is specified) : Up to 10 points (Z0 to 18) (Use index register [Z] as double word) 
  • Pointer [P] : 4096 points (P 0 ~ 4095) (Number of device points fixed) Use range of local pointer / common pointer can be set by parameter 
  • Interrupt pointer [I] : 256 points (I 0 to 255) (the number of device points is fixed) Periodic interval of system interrupt pointer I 28 to 31 can be set by parameter (0.5 to 1000.0 ms, 0.5 ms increments) Default I 28: 100 ms, I 29: 40 ms, I 30: 20 ms , I31: 10 ms 
  • Special relay [SM] : 2048 points (SM 0 to 2047) (Device number is fixed) 
  • Special register [SD] : 2048 points (SD 0 to 2047) (the number of device points is fixed) 
  • Function input [FX] : 16 points (FX 0 to F) (Device number is fixed) 
  • Function output [FY] : 16 points (FY 0 to F) (the number of device points is fixed) 
  • Function register [FD] : 5 points (FD 0 ~ 4) (Device number is fixed) 
  • Link direct device : J □□ \ X □□, J □□ \ Y □□, J □□ \ SB □□, J □□ \ SB □□, J □□ \ SB □□, J □□ \ SW □□, J □□ \ SW □ Device specification form for directly accessing the link device of the network unit □ 
  • Intelligent functional unit device : Device specification that directly accesses buffer memory of intelligent function module Format: U □□ \ G □□ 
  • Latch (power outage hold) range : L 0 to 8191 (default 8192 points) [latch range can be set for B, F, V, T, ST, C, D, W] 
  • RUN / PAUSE contact : One point of each RUN / PAUSE contact can be set from X 0 to 1 FFF 
  • Clock function : Year, month, day, hour, minute, second, day of the week (leap year automatic discrimination) accuracy: -2.97 ~ + 3.75s (. TYP + 0.39s) / d at 0 ? accuracy: -2.97 ~ + 3.75s (TYP + . 0.39 s) / d at 25 ° C Accuracy: -12.77 to + 2.13 s (TYP. -5.32 s) / d at 55 ° C 
  • Allowable momentary power failure time : Depends on power supply unit 
  • DC 5 V Internal current consumption : 0.58 A (single CPU unit) / 0.6 A (when extended SRAM cassette is installed) 
  • External dimensions:-
  • Height (H) : 98 mm 
  • Width (W) : 27.4 mm 
  • Depth (D) : 115 mm 
  • mass : 0.20 kg 
  • Built-in Ethernet function section : 
  • Transmission specification:-
  • Data transmission speed : 100/10 Mbps 
  • Communication mode : Full duplex / half duplex 
  • Transmission method : Baseband 
  • Hub and node longest distance : 100 m 
  • Number of connections : Socket communication, MELSOFT connection, MC protocol total 16 pieces 1 for FTP 
  • Operating ambient temperature : 0 to 55 ° C 
  • Storage ambient temperature : -25 to 75 ° C (-20 to 75 ° C when system includes AnS / A series unit) 
  • Ambient operating humidity : 5 to 95% RH, non condensing (10 to 90% RH when the system includes AnS / A series unit) 
  • Storage ambient humidity : 5 to 95% RH, non condensing (10 to 90% RH when the system includes AnS / A series unit) 
  • Anti-vibration Meets JIS B 3502, IEC 61131-2- When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions 
  • Anti-vibration Meets JIS B 3502, IEC 61131-2- When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2 
  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions) 
  • Use atmosphere : No corrosive gas 
  • Use elevation : 0 to 2000 m 
  • Installation location : In the control panel 
  • Over voltage category : II or less 
  • Pollution degree : 2 or less 
  • Device class : Class I 
  • Shipping Weight : 2 Kg