OMRON , MITSUBISHI , DELTA , LS , WIINTEK WEINVIEW, VEICHI , FUJI ELECTRIC , PROFACE , FATEK , SIEMENS , CUTES , EMERSON , SHIHLIN ELECTRIC , SLANVERT , DANFOSS , MOXA , WACON, YASKAWA Etc
Kontak Kami
KONTAK KAMI : Telpon : 02126071413 Hp/WhatsApp : 081212269831
Perwakilan Jakarta : Gedung LTC Glodok Lantai 1 Blok C30 No.31 Jl.Hayam Wuruk No.127 Jakarta , Indonesia
Tampilkan postingan dengan label QJ61BT11N. Tampilkan semua postingan
Tampilkan postingan dengan label QJ61BT11N. Tampilkan semua postingan
Selasa, 23 Juni 2020
Kamis, 11 Juni 2020
Jual Mitsubishi QJ61BT11N
QJ61BT11N
MELSEC-Q Series CC-Link Master/Local Module QJ61BT11N
Feature
These modules are available as master or local stations for CC-Link
CC-Link parameters can be set on the Parameter Setting screen of the programming software GX Works 2 for MELSEC
Setting a standby master station can maintain a data link even if there is something wrong with the regular master station. Additionally, a redundant function enables the master station to return to the system even during data link control at the standby master station in anticipation of the breakdown of the standby master station
High-speed communication is available in remote I/O network mode only when slave stations are remote I/O stations (Parameter setting is not required either)
Senin, 12 Februari 2018
CC-Link Master/Local modules, bridge modules : RJ61BT11,QJ61BT11N,L26CPU-BT,L26CPU-PBT,LJ61B11,FX3U-16CCL-M,NZ2GF-CCB,NZ2AW1C1BY,NZ2AW1C2D2,NZ2AW1C2AL,
MELSEC iQ-R Series
RJ61BT11
MELSEC-Q Series
QJ61BT11N
RJ61BT11
Occupied I/O points: 32 points
Occupied stations (as local stations): 1 to 4*1 (selectable)
MELSEC-Q Series
QJ61BT11N
Occupied I/O points: 32 points
Occupied stations (as local stations): 1 to 4*1 (selectable)
MELSEC-L Series CPU (with master/local station function)
L26CPU-BT (sink type output)
L26CPU-PBT (Source type output)
Occupied I/O points: 32 points
Occupied stations (as local stations): 1 to 4*1 (selectable)
(CPU part)
I/O points: 4096 points
I/O device points: 8192 points
Program size: 260K steps
MELSEC-L Series
LJ61B11
Occupied I/O points: 32 points
Occupied stations (as local stations): 1 to 4*1 (selectable)
MELSEC-FX Series
FX3U-16CCL-M
Occupied I/O points: 8 points
Can be used only as a master station
CC-Link IE Field Network-CC-Link Bridge module
NZ2GF-CCB
CC-Link IE Field Network-CC-Link Bridge module
With CC-Link master station function*1
CC-Link-AnyWire Bitty Bridge module
NZ2AW1C1BY
Remote device station
Occupied stations: 1 to 4
With AnyWire Bitty master station function
CC-Link-AnyWire DB A20 Bridge module
NZ2AW1C2D2
Remote device station (for CC-Link Ver.2)
Occupied stations: 4
With AnyWire DB A20 master station function
CC-Link-AnyWireASLINK Bridge module
NZ2AW1C2AL
Remote device station
Occupied stations: 1 to 4
with AnyWireASLINK master station function
Jumat, 05 Januari 2018
Network/Information Processing Module : QJ71MES96,QJ71LP21-25,QJ71LP21S-25,QJ71LP21G(E),QJ71BR11,QJ2LP25-25,QJ2LP25G (E),QJ72BR15,Q80BD-J71LP21-25,Q80BD-J71LP21S-25,Q80BD-J71LP21G(E),Q80BD-J71BR11,QJ61BT11N, Q80BD-J61BT11N,QJ61CL12,QJ71C24N,QJ71C24N-R2,QJ71C24N-R4,QJ71FL71-T-F01,QJ71FL71-B5-F01,QJ71FL71-B2-F02,QJ71AS92,QD51 QD51-R24
MES Interface Module
QJ71MES96
Ethernet Modules
QJ71LP21-25
QJ71LP21S-25
QJ71LP21G(E)
QJ71BR11
QJ2LP25-25
QJ2LP25G (E)
QJ72BR15
MELSECNET/H PC I/F Boards
Q80BD-J71LP21-25
Q80BD-J71LP21S-25
Q80BD-J71LP21G(E)
Q80BD-J71BR11
CC-Link Module
QJ61BT11N
CC-Link PC I/F Board
Q80BD-J61BT11N
CC-Link/LT Module
QJ61CL12
Serial Communication Module
QJ71C24N
QJ71C24N-R2
QJ71C24N-R4
FL-net (OPCN-2) Interface Module
QJ71FL71-T-F01
QJ71FL71-B5-F01
QJ71FL71-B2-F02
AS-i Master Module
QJ71AS92
Intelligent Communication Modules
QD51
QD51-R24
Label:
Q80BD-J71BR11,
Q80BD-J71LP21G(E),
QD51,
QD51-R24,
QJ2LP25-25,
QJ61BT11N,
QJ61CL12,
QJ71AS92,
QJ71C24N,
QJ71C24N-R2,
QJ71C24N-R4,
QJ71FL71-B2-F02,
QJ71LP21-25,
QJ71LP21G(E),
QJ71MES96
Langganan:
Postingan (Atom)