OMRON , MITSUBISHI , DELTA , LS , WIINTEK WEINVIEW, VEICHI , FUJI ELECTRIC , PROFACE , FATEK , SIEMENS , CUTES , EMERSON , SHIHLIN ELECTRIC , SLANVERT , DANFOSS , MOXA , WACON, YASKAWA Etc
Kontak Kami
KONTAK KAMI : Telpon : 02126071413 Hp/WhatsApp : 081212269831
Perwakilan Jakarta : Gedung LTC Glodok Lantai 1 Blok C30 No.31 Jl.Hayam Wuruk No.127 Jakarta , Indonesia
Menampilkan postingan yang diurutkan menurut tanggal untuk kueri inverter mitsubishi. Urutkan menurut relevansi Tampilkan semua postingan
Menampilkan postingan yang diurutkan menurut tanggal untuk kueri inverter mitsubishi. Urutkan menurut relevansi Tampilkan semua postingan
Selasa, 29 September 2020
Selasa, 30 Juni 2020
Kamis, 25 Juni 2020
Rabu, 24 Juni 2020
Senin, 22 Juni 2020
Rabu, 17 Juni 2020
Senin, 08 Juni 2020
Kamis, 05 September 2019
Jual PLC Mitsubishi, HMI Mitsubishi , Inverter Mitsubishi & Servo Mitsubishi
ERNT-AQB38
ERNT-AQF8
ERNT-AQTX11
ERNT-AQTX40
ERNT-AQTX41
ERNT-AQTY10
ERNT-AQTY22
ERNT-AQTY23
ERNT-AQTY40
ERNT-AQTY41
F2-40BL
F920GOT-BBD5-K-E
FA-CBL10FMV
FA-CBL20FMV
FA-CBL20FMV-M
FA-CNV2402CBL
FA-LTB40P
FA-TBS32XY
FR-A720-0.4K
FR-A720-0.75K
FR-A720-18.5K
FR-A720-7.5K
FR-A720-0.4K
FR-A740-11K
FR-A740-18.5K
FR-A720-22K
FR-A740-30K
FR-A740-37K
FR-A740-5.5K
FR-A7AP
FR-A7AX
FR-A7AY
FR-A7NC-E-KIT
FR-A820-0.4K-1
FR-A820-0.75K-1
FR-A820-1.5K-1
FR-A820-11K-1
FR-A820-15K-1
FR-A820-18.5K-1
FR-A820-2.2K-1
FR-A820-22K-1
FR-A820-3.7K-1
FR-A820-5.5K-1
FR-A820-55K-1
FR-A820-7.5K-1
FR-A840-0.4K-1
FR-A840-0.75K-1
FR-A840-1.5K-1
FR-A840-11K-1
FR-A840-15K-1
FRA840-18.5K-1
FR-A840-2.2K-1
FR-A840-22K-1
FR-A840-3.7K-1
FR-A840-37K-1
FR-A840-5.5K
FR-A840-7.5K-1
FR-A840-90K-1
FR-A8AP
FR-A8AX
FR-A8AY
FR-A8NC
FR-ABR-0.75K
FR-ABR-2.2K
FR-ADP
FR-B-750
FR-BSF01
FR-BU2-30K
FR-CB205
FR-D720-0.2K
FR-D720-0.4K
FR-D720-0.75K
FR-D720-1.5K
FR-D720-2.2K
FR-D720-3.7K
FR-D720-5.5K
FR-D720-7.5K
FR-D720S-0.1K
FR-D720S-0.2K
FR-D720S-0.4K
FR-D720S-0.75K
FR-D720S-1.5K
FR-D720S-2.2K
FR-D740-0.4K
FR-D740-0.4K-CHT
FR-D740-0.75K
FR-D740-0.75K-CHT
FR-D740-1.5K
FR-D740-1.5K-CHT
FR-D740-11K
FR-D740-15K
FR-D740-2.2K
FR-D740-2.2K-CHT
FR-D740-3.7K
FR-D740-3.7K-CHT
FR-D740-5.5K
FR-D740-5.5K-CHT
FR-D740-7.5K
FR-D740-7.5K-CHT
FR-E520-0.1K
FR-E720-0.1K
FR-E720-0.2K
FR-E720-0.4K
FR-E720-0.75K
FR-E720-1.5K
FR-E720-11K
FR-E720-2.2K
FR-E720-3.7K
FR-E720-5.5K
FR-E720-7.5K
FR-E720S-0.2
FR-E720S-0.4K
FR-E720S-0.75K
FR-E720S-1.5K
FR-E720S-2.2K
FR-E740-0.4K
FR-E740-0.4K-CHT
FR-E740-0.75K
FR-E740-0.75K-CHT
FR-E740-1.5K
FR-E740-1.5K-CHT
FR-E740-11K
FRE740-2.2K
FR-E740-2.2-CHT
FR-E740-3.7K
FR-E740-3.7K-CHT
FR-E740-5.5K
FR-E740-5.5K-CHT
FR-E740-7.5K
FR-E740-7.5K-CHT
FR-HEL-5.5K
FR-PA02
FR-PA07
FR-PU04
FR-PU07
FR-S540E-0.4K
FR-S540E-0.4K-EC
FR-S540E-1.5K-EC
FR-S540E-2.2K
FR-S540E-3.7K-EC
FX-50DU-CABO
FX-50DU-CABO 10 METER
FX-USB-AW
FX0N-40ET-DSS
FX0N-65EC
F920GOT-BBD-K-E
GPW-CB02
GS2107-WTBD
GS2110-WTBD
GT01-C100R4-8P
GT01-C30R2-6P
GT01C30R4-8P
GT09-C30USB-5P
GT10-C10R4-8P
GT10-C30R2-6P
GT10-C30R4 25P
GT10-C30R4-8P
GT1030-HBD
GT1030-HBD2
GT1050-QBBD
GT1055-QSBD
GT1055-QSBD-C
GT11-50BAT
GT1455-QTBD
GT1455-QTBDE
GT15-A1SC50B
GT15-J61BT13
GT15-QBUS
GT15-QBUS2
GT15-QC30B
GT15-QFNB16M
GT16-C02R4-9S
GT1662-VNBA
GT1665M-VTBA
GT1675-VNBA
GT168M-STBA
GT2103-PMBD
GT2103-PMBDS
GT2104-PMBDS
GT2105-QMBDS
GT2105-QTBDS
GT2308-VTBA
GT2310-VTBA
GT2310-VTBD
GT2508-VTBA
GT2510-VTBA
GT2510-VTBD
GT2705-VTBD
GT2708-VTBA
GT2710-STBA
GT2712-STBA
GT2712-STBD
GT2715-XTBA
HC-KFS23
HC-KFS23B
HC-MFS13
HC-MFS23
HC-RFS153
HC-SFS352
HC-SFS502
HC-SFS52B
HF-KP13
HF-KP13B
HF-KP13D
HF-KP23
HF-KP23B
HF-KP43
HF-KP43B
HF-KP73
HF-KP73B
HF-SP102
HF-SP102B
HF-SP152
HF-SP202
HF-SP352
HF-SP352B
HF-SP52
HF-SP702
HG-KN23BJ
HG-KN43J-S100
HG-KN43JK-S100
HG-KN73J-S100
HG-KR13G1-1/12
HG-KR23J
HG-KR43
HG-KR43BJ
HG-KR43J
HGKR43JK
HG-KR73BJK
HGKR73BK
HG-KR73J
HGSN102J-S100
HG-SR102
HG-SR102B
HG-SR102J
HG-SR152
HG-SR152BK
HG-SR152J
HG-SR152JK
HG-SR202J
HG-SR352B
HG-SR352J
HG-SR421
HG-SR502
HG-SR502B
HG-SR502J
HG-SR52
HG-SR52J
HG-SR702
HG-SR702J
LE-5AP
MMF-06F24ES
MR-A-TM
MR-BAT
MR-BAT6V1SET
MR-BKCN
MR-BKCNS1
MR-BKS1CBL10M-A2-H-C
MR-BKS1CBL10M-A2-L
MR-BKS1CBL10M-A2-L C
MR-BKS1CBL5M-A1-H
MR-BKS1CBL5M-A1-L
MR-BKS1CBL5M-A2-H CH
MR-BKS1CBL5M-A2-L
MR-BKS1CBL5M-A2-L C
MR-BKS2CBL03M-A1-L
MR-CCN1
MR-CPCATCBL-3M
MR-E-40A-KH003
MR-EKCBL10M-H
MR-EKCBL20M-H
MR-EKCBL20M-L
MR-ENCNS
MR-J2CN1
MR-J2HBUS1M-A
MR-J2M-CN1TBL05M
MR-J2M-CN1TBL1-M
MR-J2S-100A
MR-J2S-100B
MR-J2S-10A
MR-J2S-10B
MR-J2S-200B
MR-J2S-20A
MR-J2S-20B
MR-J2S-60B
MR-J2S-700A
MR-J2S-70A
MR-J2S-70B
MR-J2TBL0.5M
MR-J2TBL1M
MR-J3-100A
MR-J3-100B
MR-J3-100T
MR-J3-10A
MR-J3-200A
MR-J3-200AN
MR-J3-20A
MR-J3-20B
MR-J3-350A
MR-J3-350B
MR-J3-40A
MR-J3-40T
MR-J3-500B
MR-J3-60A
MR-J3-60B
MR-J3-700A
MR-J3-700B
MR-J3-70A
MR-J3-70B
MR-J3-BAT
MR-J3-CN1
MR-J3BUS03M
MR-J3BUS05M
MR-J3BUS1M
MR-J3BUS3M
MR-J3CN6CBL-1M
MR-J3ENCBL10M-A2-H
MR-J3ENCBL10M-A2-H C
MR-J3ENCBL10M-A2-L
MR-J3ENCBL10M-A2-L-C
MR-J3ENCBL20M-A2-L C
MR-J3ENCBL5M-A1-H
MR-J3ENCBL5M-A1-L
MR-J3ENCBL5M-A2-H
MR-J3ENCBL5M-A2-H C
MR-J3ENCBL5M-A2-L
MR-J3ENCBL5M-A2-L C
MR-J3ENSCBL10M-H
MR-J3ENSCBL10M-L
MR-J3ENSCBL10M-L CHN
MR-J3ENSCBL20M-H
MR-J3ENSCBL20M-L
MR-J3ENSCBL20M-L CHN
MR-J3ENSCBL2M-H
MR-J3ENSCBL2M-L
MR-J3ENSCBL30M-L
MR-J3ENSCBL30M-L C
MR-J3ENSCBL5M-H
MR-J3ENSCBL5M-L
MR-J3ENSCBL5M-L C
MR-J3JCBL03M-A1-L
MR-J3JCBL03M-A2-L
MR-J3USBCBL3M
MR-J4-100A
MR-J4-100B
MR-J4-10B
MR-J4-200A
MR-J4-200B
MR-J4-20A
MR-J4-20B
MR-J4-350A
MR-J350A J
MR-J4-350B
MR-J4-40A
MR-J4-40A J
MR-J4-40B
MR-J4-500A
MR-J4-500B
MR-J4-60A
MR-J4-60B
MR-J4-700A
MR-J4-700B
MR-J4-70A
MR-J4-70B
MR-J4-70B-RJ020
MR-JCCBL10M-H
MR-JCCBL10M-L
MR-JCCBL5M-H
MR-JCCBL5M-L
MR-JE-100A
MR-JE-70A
MR-JHSCBL10M-H
MR-JHSCBL10M-L
MR-JHSCBL20M-L
MR-JHSCBL5M-L
MR-JN-20A
MR-PWCNK1
MR-PWCNK2
MR-PWCNS2
MR-PWCNS3
MR-PWCNS4
MR-PWCNS5
MR-PWS1CBL10M-A1-H
MR-PWS1CBL10M-A2-H
MR-PWS1CBL10M-A2-H C
MR-PWS1CBL10M-A2-L
MR-PWS1CBL10M-A2-L C
MR-PWS1CBL5M-A1-H
MR-PWS1CBL5M-A1-L
MR-PWS1CBL5M-A2-H
MR-PWS1CBL5M-A2-H C
MR-PWS1CBL5M-A2-L
MR-PWS2CBL03M-A2-L
MR-RB30
MR-TB20
MR-TB50
Q00CPU
Q00UCPU
Q00UJCPU
Q01CPU
Q01UCPU
Q02CPU
Q02HCPU
Q02HCPU-A
Q02UCPU
Q03UDCPU
Q03UDECPU
Q03UDVCPU
Q04UDEHCPU
Q04UDVCPU
Q06HCPU
Q06UDEHCPU
Q06UDVCPU
Q13UDEHCPU
Q13UDVCPU
Q172LX
Q1MEM-1MSE
Q25HCPU
Q2MEM-16MBA
Q2MEM-1MBS
Q312B
Q312DB
Q33B
Q35B
Q35BL
Q38B
Q38BL
Q38DB
Q3MEM-4MBS
Q52B
Q55B
Q55BL
Q612B
Q61P
Q61SP
Q62AD-DGH
Q62DAN
Q62P
Q63P
Q63RP
Q64AD
Q64AD
Q64DAN
Q64PN
Q64TCRTN
Q64TCTTN
Q64TD
Q65B
Q65BL
Q68AD-G
Q68ADI
Q68ADV
Q68B
Q68BL
Q68DAIN
Q68DAVN
Q6BAT
Q7BAT
QA1S51B
QC05B
QC06B
QC12B
QC30B
QC30R2 CHN
QC30R2
QC50B
QD62
QD62D
QD75D1N
QD75D2N
QD75D4N
QD75M1
QD75M2
QD75P1N
QD75P2N
QD77MS16
QD77MS2
QD77MS4
QG60
QG69L
QH42P
QJ61BT11N
QJ71BR11
QJ71C24N
QJ71C24N-R2
QJ71C24N-R4
QJ71DN91
QJ71E71-100
QJ71GF11-T2
QJ71LP21-25
QJ71MB91
QJ71MT91
QJ71NT11B
QJ71PB92V
QJ72LP25-25
QX10
QX11L
QX28
QX40
QX40-S1
QX41
QX41-S1
QX41-S2
QX41Y41P
QX42
QX42-S1
QX48Y57
QX50
QX70
QX70H
QX71
QX80
QX81
QX82
QX82-S1
QY10
QY13L
QY18A
QY22
QY23L
QY40P
QY41P
QY42P
QY50
QY51PL
QY68A
QY80
QY81P
QY82P
USB-QC30R2 ORI
SC-09 BEIJER
USB CONVERTER FTDI
SW1DND-GTWK3-E
USB-CIF02
USB-SC09 ORI
USB-QC30R2 ORI
USB-SC09 HIGH
Kamis, 13 Juni 2019
MITSUBISHI PLC FX3G Series
FX3G MELSEC Compact PLC
MITSUBISHI PLC FX3G has the versatility to handle applications from a wide range of industries.
Special Features of MITSUBISHI PLC FX3U series
- Applies the proven FX3U design to smaller but performance critical applications
- Add a variety of capabilities to suit specific application needs
- Builds on existing FX series hardware and programming for quick adoption and investment protection
- Direct control of inverter and motion control systems with no extra hardware
Feel our strength
Mitsubishi Electric is the undisputed world leading supplier of compact PLCs. We origi- nated the concept of this type of controller over thirty years ago. Our global installed base exceeds 9 million systems and our phi- losophy of listening to customer needs insures this base continues to grow. The introduction of the FX3U PLC set a new benchmark for performance and flexibility in the compact PLC market and we have continued to innovate. The result is the FX3G, our new answer to applications nee- ding FX3U like capabilities in smaller scale systems.
More for less
While being intended for smaller systems, the FX3G still delivers a powerful combina- tion of essential features, plus more not expected from a controller at this level. These include; a large program memory to implement sophisticated algorithms, ample space for data storage, logging or recipes, plus high speed execution to enhance sys- tem productivity. A dual bus architecture provides flexible expansion possibilities for additional I/O capacity and communication functions.
Easy system integration
The FX3G can operate as a standalone con- troller, but for when integration with other system components is required, a range of standard features makes it stand out from the crowd. Mitsubishi builds in standard instructions that permit easy control of our inverters over a precise, reliable digital link. This makes it simple to connect an inverter such as a FR-D700 to provide more precise motor operation while optimizing energy use.
Easy expansion
When it comes to increasing the capabili- ties of an FX3G, we extend your options while protecting your skills and invest- ments. The dual bus architecture provides twice as many expansion possibilities com- pared to previous designs. On one bus, the FX3G uses additional, familiar FX family I/O and special function blocks to add a com- prehensive variety of I/O and special func- tion capabilities such as analogue and networking. On the other system bus, the FX3G uses the existing FX3U special adapt- ers to provide high performance communi- cation and analog capabilities that are directly linked to the CPU. This reduces pro- gramming while increasing performance, leading to faster development and higher productivity.
The great communicator
Finally, the FX3G offers you a wide selection of options when it comes to networking and communications. This begins with standard serial communication support and builds up to comprehensive coverage of common open automation networks. These include CC-Link, CANopen, Profibus-DP and Ethernet. Further, a built-in USB port makes permits convenient connection to any PC or laptop for high speed program uploads and downloads along with moni- toring.
Specifications
Specifications | FX3G-14M | FX3G-24M | FX3G-40M | FX3G-60M | ||
I/O points | 256 total (combined local and CC-Link remote I/O) | |||||
Address range | Max. 128 direct addressing and max. 128 remote I/O | |||||
Power supply | 100–240 V AC (+10 % / -15 %), 50/60 Hz | |||||
Program memory | 32,000 steps EEPROM (internal), exchangeable EEPROM memory cassette with loader function | |||||
Instruction Time | 0.21 μs or 0.42 μs / contact instruction | |||||
Integrated inputs | Number of inputs | 8 | 14 | 24 | 36 | |
Input signal voltage | 24 V DC (+/-10 %) | |||||
Input form | sink/source | |||||
Response time | Approx. 10 ms | |||||
Isolation | Photocoupler isolation | |||||
Integrated outputs | Number of outputs | 6 | 10 | 16 | 48 | |
Switching voltage | <240 V AC, <30 V DC (relay output), 5 – 30 V DC (transistor output) | |||||
Output type/form | Relay or transistor | |||||
Max. load | resistive | 2A/point, max. 8 A total (relay), 0.5 A/point; max. 0.8 A for 4 output points/common terminal (transistor) | ||||
inductive | 80 VA (relay), 12 W/point (at 24 V DC); max. 19.2 W for 4 output points/common terminal (transistor) | |||||
Response time | 10 ms (relay), < 5 μs (for Y000 and Y001) / 0.2 ms (for all other outputs) (transistor) (The 40 and 60 I/O point transistor output base units have a 5μs response time for Y002) | |||||
Isolation | Photocoupler isolation | |||||
High-speed counters | 21 total, with 16 1-phase (C235 - C250) and 5 2-phase (C251 - C255) | |||||
High-speed outputs | -2,147,483,648 to 2,147,483,647 | |||||
24V DC service power supply | 400 mA | |||||
Environment | 0 – 55 °C ambient temperature; 5 – 95 % relative humidity |
Jumat, 22 Maret 2019
MITSUBISHI FR-A840-500K-1
Specifications
Application
|
FR-A840 inverter is designed suitable for all machines, cranes, conveyors, presses, extruders, printers, woodworking machines, compressors, machine tools need high precision .. .
|
Power supply
|
AC 3P 400V, 60Hz
|
Rated capacity
|
500kW
|
Rated current
|
0.8-962A (400V)
|
Output frequency range
|
0.2-590Hz
|
Starting Torque
|
SLD Rating:120% 0.3 Hz, LD Rating:150% 0.3 Hz, ND Rating:200% 0.3 Hz, HD Rating:250% 0.3 Hz (Real sensorless vector control, vector control)
|
Overload current rating
|
ND Rating: 150 % of rated output current for 60 s, HD Rating: 200 % of rated output current for 60 s (Derating may be required for repetitive loads )
|
Control Method
|
Soft-PWM control, high carrier frequency PWM control (selectable among V/F control, Advanced magnetic flux vector control, Real sensorless vector control, Optimum excitation control), vector control, and PM sensorless vector control
|
Braking unit
| |
Input
|
Multi-Function Digital Input
|
Ouput
|
Rated capacity, Rated current, Overload current rating, Rated voltage, Regenerative braking
|
Protection Function
|
Input phase loss protection selection, Speed limit, OLT level setting, Fault definition
Overcurrent trip during acceleration, Overcurrent trip during constant speed, Overcurrent trip during deceleration or stop, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during constant speed, Regenerative overvoltage trip during deceleration or stop, Inverter overload trip, Motor overload trip, Heatsink overheat
|
Main Control Functions
|
Maximum and minimum frequency settings, multi-speed operation, acceleration/deceleration pattern, thermal protection,DC injection brake, starting frequency, JOG operation, output stop (MRS), stall prevention, regeneration avoidance, increased magnetic excitation deceleration,rotation display, automatic restart after instantaneous power failure, electronic bypass sequence, remote setting, automatic acceleration/deceleration, intelligent mode, retry function, carrier frequency selection, fast-response current limit, forward/reverse rotation prevention, operation mode selection, slip compensation, droop control, load torque high-speed frequency control, speed smoothing control, traverse, auto tuning, applied motor selection, gain tuning, RS-485 communication, PID control, PID pre-charge function, easy dancer control, cooling fan operation selection, stop selection (deceleration stop/coasting),speed control, torque control, position control, pre-excitation, torque limit, test run, 24 V power supply input for control circuit, safety stop function, swinging suppression control
|
Communication
|
Ethernet, CC-Link, CC-Link/LT, SSCNETⅢ, CANopen, J1939, RS-232C, RS-422, RS-485, MODBUS
|
Peripheral Devices and Options
|
Plug-in Type: Vector control,Orientation/encoder, 16-bit digital input, Digital output Extension analog output, Relay output, CC-Link communication, DeviceNet communication, PROFIBUS-DP communication
Stand-alone Shared: Cable for encoder Mitsubishi vector control dedicated motor (SF-V5RU),Control circuit terminal block intercompatibility attachment, Intercompatibility attachment, AC reactor, DC reactor, Line noise filter, High-duty brake resistor
|
Degree of protection
|
IP00 (open type), IP20( enclose type)
|
MITSUBISHI FR-A840-450K-1
Specifications
Application
|
FR-A840 inverter is designed suitable for all machines, cranes, conveyors, presses, extruders, printers, woodworking machines, compressors, machine tools need high precision .. .
|
Power supply
|
AC 3P 400V, 60Hz
|
Rated capacity
|
450kW
|
Rated current
|
0.8-962A (400V)
|
Output frequency range
|
0.2-590Hz
|
Starting Torque
|
SLD Rating:120% 0.3 Hz, LD Rating:150% 0.3 Hz, ND Rating:200% 0.3 Hz, HD Rating:250% 0.3 Hz (Real sensorless vector control, vector control)
|
Overload current rating
|
ND Rating: 150 % of rated output current for 60 s, HD Rating: 200 % of rated output current for 60 s (Derating may be required for repetitive loads )
|
Control Method
|
Soft-PWM control, high carrier frequency PWM control (selectable among V/F control, Advanced magnetic flux vector control, Real sensorless vector control, Optimum excitation control), vector control, and PM sensorless vector control
|
Braking unit
| |
Input
|
Multi-Function Digital Input
|
Ouput
|
Rated capacity, Rated current, Overload current rating, Rated voltage, Regenerative braking
|
Protection Function
|
Input phase loss protection selection, Speed limit, OLT level setting, Fault definition
Overcurrent trip during acceleration, Overcurrent trip during constant speed, Overcurrent trip during deceleration or stop, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during constant speed, Regenerative overvoltage trip during deceleration or stop, Inverter overload trip, Motor overload trip, Heatsink overheat
|
Main Control Functions
|
Maximum and minimum frequency settings, multi-speed operation, acceleration/deceleration pattern, thermal protection,DC injection brake, starting frequency, JOG operation, output stop (MRS), stall prevention, regeneration avoidance, increased magnetic excitation deceleration,rotation display, automatic restart after instantaneous power failure, electronic bypass sequence, remote setting, automatic acceleration/deceleration, intelligent mode, retry function, carrier frequency selection, fast-response current limit, forward/reverse rotation prevention, operation mode selection, slip compensation, droop control, load torque high-speed frequency control, speed smoothing control, traverse, auto tuning, applied motor selection, gain tuning, RS-485 communication, PID control, PID pre-charge function, easy dancer control, cooling fan operation selection, stop selection (deceleration stop/coasting),speed control, torque control, position control, pre-excitation, torque limit, test run, 24 V power supply input for control circuit, safety stop function, swinging suppression control
|
Communication
|
Ethernet, CC-Link, CC-Link/LT, SSCNETⅢ, CANopen, J1939, RS-232C, RS-422, RS-485, MODBUS
|
Peripheral Devices and Options
|
Plug-in Type: Vector control,Orientation/encoder, 16-bit digital input, Digital output Extension analog output, Relay output, CC-Link communication, DeviceNet communication, PROFIBUS-DP communication
Stand-alone Shared: Cable for encoder Mitsubishi vector control dedicated motor (SF-V5RU),Control circuit terminal block intercompatibility attachment, Intercompatibility attachment, AC reactor, DC reactor, Line noise filter, High-duty brake resistor
|
Degree of protection
|
IP00 (open type), IP20( enclose type)
|
MITSUBISHI FR-A840-400K-1
Specifications
Application
|
FR-A840 inverter is designed suitable for all machines, cranes, conveyors, presses, extruders, printers, woodworking machines, compressors, machine tools need high precision .. .
|
Power supply
|
AC 3P 400V, 60Hz
|
Rated capacity
|
400kW
|
Rated current
|
0.8-962A (400V)
|
Output frequency range
|
0.2-590Hz
|
Starting Torque
|
SLD Rating:120% 0.3 Hz, LD Rating:150% 0.3 Hz, ND Rating:200% 0.3 Hz, HD Rating:250% 0.3 Hz (Real sensorless vector control, vector control)
|
Overload current rating
|
ND Rating: 150 % of rated output current for 60 s, HD Rating: 200 % of rated output current for 60 s (Derating may be required for repetitive loads )
|
Control Method
|
Soft-PWM control, high carrier frequency PWM control (selectable among V/F control, Advanced magnetic flux vector control, Real sensorless vector control, Optimum excitation control), vector control, and PM sensorless vector control
|
Braking unit
| |
Input
|
Multi-Function Digital Input
|
Ouput
|
Rated capacity, Rated current, Overload current rating, Rated voltage, Regenerative braking
|
Protection Function
|
Input phase loss protection selection, Speed limit, OLT level setting, Fault definition
Overcurrent trip during acceleration, Overcurrent trip during constant speed, Overcurrent trip during deceleration or stop, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during constant speed, Regenerative overvoltage trip during deceleration or stop, Inverter overload trip, Motor overload trip, Heatsink overheat
|
Main Control Functions
|
Maximum and minimum frequency settings, multi-speed operation, acceleration/deceleration pattern, thermal protection,DC injection brake, starting frequency, JOG operation, output stop (MRS), stall prevention, regeneration avoidance, increased magnetic excitation deceleration,rotation display, automatic restart after instantaneous power failure, electronic bypass sequence, remote setting, automatic acceleration/deceleration, intelligent mode, retry function, carrier frequency selection, fast-response current limit, forward/reverse rotation prevention, operation mode selection, slip compensation, droop control, load torque high-speed frequency control, speed smoothing control, traverse, auto tuning, applied motor selection, gain tuning, RS-485 communication, PID control, PID pre-charge function, easy dancer control, cooling fan operation selection, stop selection (deceleration stop/coasting),speed control, torque control, position control, pre-excitation, torque limit, test run, 24 V power supply input for control circuit, safety stop function, swinging suppression control
|
Communication
|
Ethernet, CC-Link, CC-Link/LT, SSCNETⅢ, CANopen, J1939, RS-232C, RS-422, RS-485, MODBUS
|
Peripheral Devices and Options
|
Plug-in Type: Vector control,Orientation/encoder, 16-bit digital input, Digital output Extension analog output, Relay output, CC-Link communication, DeviceNet communication, PROFIBUS-DP communication
Stand-alone Shared: Cable for encoder Mitsubishi vector control dedicated motor (SF-V5RU),Control circuit terminal block intercompatibility attachment, Intercompatibility attachment, AC reactor, DC reactor, Line noise filter, High-duty brake resistor
|
Degree of protection
|
IP00 (open type), IP20( enclose type)
|
MITSUBISHI FR-A840-355K-1
Specifications
Application
|
FR-A840 inverter is designed suitable for all machines, cranes, conveyors, presses, extruders, printers, woodworking machines, compressors, machine tools need high precision .. .
|
Power supply
|
AC 3P 400V, 60Hz
|
Rated capacity
|
355kW
|
Rated current
|
0.8-962A (400V)
|
Output frequency range
|
0.2-590Hz
|
Starting Torque
|
SLD Rating:120% 0.3 Hz, LD Rating:150% 0.3 Hz, ND Rating:200% 0.3 Hz, HD Rating:250% 0.3 Hz (Real sensorless vector control, vector control)
|
Overload current rating
|
ND Rating: 150 % of rated output current for 60 s, HD Rating: 200 % of rated output current for 60 s (Derating may be required for repetitive loads )
|
Control Method
|
Soft-PWM control, high carrier frequency PWM control (selectable among V/F control, Advanced magnetic flux vector control, Real sensorless vector control, Optimum excitation control), vector control, and PM sensorless vector control
|
Braking unit
| |
Input
|
Multi-Function Digital Input
|
Ouput
|
Rated capacity, Rated current, Overload current rating, Rated voltage, Regenerative braking
|
Protection Function
|
Input phase loss protection selection, Speed limit, OLT level setting, Fault definition
Overcurrent trip during acceleration, Overcurrent trip during constant speed, Overcurrent trip during deceleration or stop, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during constant speed, Regenerative overvoltage trip during deceleration or stop, Inverter overload trip, Motor overload trip, Heatsink overheat
|
Main Control Functions
|
Maximum and minimum frequency settings, multi-speed operation, acceleration/deceleration pattern, thermal protection,DC injection brake, starting frequency, JOG operation, output stop (MRS), stall prevention, regeneration avoidance, increased magnetic excitation deceleration,rotation display, automatic restart after instantaneous power failure, electronic bypass sequence, remote setting, automatic acceleration/deceleration, intelligent mode, retry function, carrier frequency selection, fast-response current limit, forward/reverse rotation prevention, operation mode selection, slip compensation, droop control, load torque high-speed frequency control, speed smoothing control, traverse, auto tuning, applied motor selection, gain tuning, RS-485 communication, PID control, PID pre-charge function, easy dancer control, cooling fan operation selection, stop selection (deceleration stop/coasting),speed control, torque control, position control, pre-excitation, torque limit, test run, 24 V power supply input for control circuit, safety stop function, swinging suppression control
|
Communication
|
Ethernet, CC-Link, CC-Link/LT, SSCNETⅢ, CANopen, J1939, RS-232C, RS-422, RS-485, MODBUS
|
Peripheral Devices and Options
|
Plug-in Type: Vector control,Orientation/encoder, 16-bit digital input, Digital output Extension analog output, Relay output, CC-Link communication, DeviceNet communication, PROFIBUS-DP communication
Stand-alone Shared: Cable for encoder Mitsubishi vector control dedicated motor (SF-V5RU),Control circuit terminal block intercompatibility attachment, Intercompatibility attachment, AC reactor, DC reactor, Line noise filter, High-duty brake resistor
|
Degree of protection
|
IP00 (open type), IP20( enclose type)
|
MITSUBISHI FR-A840-315K-1
Specifications
Application
|
FR-A840 inverter is designed suitable for all machines, cranes, conveyors, presses, extruders, printers, woodworking machines, compressors, machine tools need high precision .. .
|
Power supply
|
AC 3P 400V, 60Hz
|
Rated capacity
|
315kW
|
Rated current
|
0.8-962A (400V)
|
Output frequency range
|
0.2-590Hz
|
Starting Torque
|
SLD Rating:120% 0.3 Hz, LD Rating:150% 0.3 Hz, ND Rating:200% 0.3 Hz, HD Rating:250% 0.3 Hz (Real sensorless vector control, vector control)
|
Overload current rating
|
ND Rating: 150 % of rated output current for 60 s, HD Rating: 200 % of rated output current for 60 s (Derating may be required for repetitive loads )
|
Control Method
|
Soft-PWM control, high carrier frequency PWM control (selectable among V/F control, Advanced magnetic flux vector control, Real sensorless vector control, Optimum excitation control), vector control, and PM sensorless vector control
|
Braking unit
| |
Input
|
Multi-Function Digital Input
|
Ouput
|
Rated capacity, Rated current, Overload current rating, Rated voltage, Regenerative braking
|
Protection Function
|
Input phase loss protection selection, Speed limit, OLT level setting, Fault definition
Overcurrent trip during acceleration, Overcurrent trip during constant speed, Overcurrent trip during deceleration or stop, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during constant speed, Regenerative overvoltage trip during deceleration or stop, Inverter overload trip, Motor overload trip, Heatsink overheat
|
Main Control Functions
|
Maximum and minimum frequency settings, multi-speed operation, acceleration/deceleration pattern, thermal protection,DC injection brake, starting frequency, JOG operation, output stop (MRS), stall prevention, regeneration avoidance, increased magnetic excitation deceleration,rotation display, automatic restart after instantaneous power failure, electronic bypass sequence, remote setting, automatic acceleration/deceleration, intelligent mode, retry function, carrier frequency selection, fast-response current limit, forward/reverse rotation prevention, operation mode selection, slip compensation, droop control, load torque high-speed frequency control, speed smoothing control, traverse, auto tuning, applied motor selection, gain tuning, RS-485 communication, PID control, PID pre-charge function, easy dancer control, cooling fan operation selection, stop selection (deceleration stop/coasting),speed control, torque control, position control, pre-excitation, torque limit, test run, 24 V power supply input for control circuit, safety stop function, swinging suppression control
|
Communication
|
Ethernet, CC-Link, CC-Link/LT, SSCNETⅢ, CANopen, J1939, RS-232C, RS-422, RS-485, MODBUS
|
Peripheral Devices and Options
|
Plug-in Type: Vector control,Orientation/encoder, 16-bit digital input, Digital output Extension analog output, Relay output, CC-Link communication, DeviceNet communication, PROFIBUS-DP communication
Stand-alone Shared: Cable for encoder Mitsubishi vector control dedicated motor (SF-V5RU),Control circuit terminal block intercompatibility attachment, Intercompatibility attachment, AC reactor, DC reactor, Line noise filter, High-duty brake resistor
|
Degree of protection
|
IP00 (open type), IP20( enclose type)
|
MITSUBISHI FR-A840-280K-1
Specifications
Application
|
FR-A840 inverter is designed suitable for all machines, cranes, conveyors, presses, extruders, printers, woodworking machines, compressors, machine tools need high precision .. .
|
Power supply
|
AC 3P 400V, 60Hz
|
Rated capacity
|
280kW
|
Rated current
|
0.8-962A (400V)
|
Output frequency range
|
0.2-590Hz
|
Starting Torque
|
SLD Rating:120% 0.3 Hz, LD Rating:150% 0.3 Hz, ND Rating:200% 0.3 Hz, HD Rating:250% 0.3 Hz (Real sensorless vector control, vector control)
|
Overload current rating
|
ND Rating: 150 % of rated output current for 60 s, HD Rating: 200 % of rated output current for 60 s (Derating may be required for repetitive loads )
|
Control Method
|
Soft-PWM control, high carrier frequency PWM control (selectable among V/F control, Advanced magnetic flux vector control, Real sensorless vector control, Optimum excitation control), vector control, and PM sensorless vector control
|
Braking unit
| |
Input
|
Multi-Function Digital Input
|
Ouput
|
Rated capacity, Rated current, Overload current rating, Rated voltage, Regenerative braking
|
Protection Function
|
Input phase loss protection selection, Speed limit, OLT level setting, Fault definition
Overcurrent trip during acceleration, Overcurrent trip during constant speed, Overcurrent trip during deceleration or stop, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during constant speed, Regenerative overvoltage trip during deceleration or stop, Inverter overload trip, Motor overload trip, Heatsink overheat
|
Main Control Functions
|
Maximum and minimum frequency settings, multi-speed operation, acceleration/deceleration pattern, thermal protection,DC injection brake, starting frequency, JOG operation, output stop (MRS), stall prevention, regeneration avoidance, increased magnetic excitation deceleration,rotation display, automatic restart after instantaneous power failure, electronic bypass sequence, remote setting, automatic acceleration/deceleration, intelligent mode, retry function, carrier frequency selection, fast-response current limit, forward/reverse rotation prevention, operation mode selection, slip compensation, droop control, load torque high-speed frequency control, speed smoothing control, traverse, auto tuning, applied motor selection, gain tuning, RS-485 communication, PID control, PID pre-charge function, easy dancer control, cooling fan operation selection, stop selection (deceleration stop/coasting),speed control, torque control, position control, pre-excitation, torque limit, test run, 24 V power supply input for control circuit, safety stop function, swinging suppression control
|
Communication
|
Ethernet, CC-Link, CC-Link/LT, SSCNETⅢ, CANopen, J1939, RS-232C, RS-422, RS-485, MODBUS
|
Peripheral Devices and Options
|
Plug-in Type: Vector control,Orientation/encoder, 16-bit digital input, Digital output Extension analog output, Relay output, CC-Link communication, DeviceNet communication, PROFIBUS-DP communication
Stand-alone Shared: Cable for encoder Mitsubishi vector control dedicated motor (SF-V5RU),Control circuit terminal block intercompatibility attachment, Intercompatibility attachment, AC reactor, DC reactor, Line noise filter, High-duty brake resistor
|
Degree of protection
|
IP00 (open type), IP20( enclose type)
|
Langganan:
Postingan (Atom)