PLC OMRON CP1E

International Standards

  • The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
  • Contact your OMRON representative for further details and applicable conditions for these standards.

Basic Model

Renewal-type

E[][]S-type CP1E CPU Units (Built-in USB port)

Product 
name
SpecificationsEx- 
ternal 
power 
supply 
(24 
VDC) 
(A)
Current 
consump- 
tion (A)
ModelStand- 
ards
Power 
Supply
In- 
puts
Out- 
puts
Out- 
put 
type
Pro- 
gram 
ca- 
pacity
Data 
memory 
capacity
5 V24 V
E[][]S-type 
CPU Units 
with 14 I/O 
Points
2064_lu_1_1
100 to 
240 
VAC
86Relay2K 
steps
2K words--0.160.07CP1E-E14SDR-ACE
E[][]S-type 
CPU Units 
with 20 I/O 
Points
2064_lu_1_2
100 to 
240 
VAC
128Relay2K 
steps
2K words--0.170.08CP1E-E20SDR-ACE
E[][]S-type 
CPU Units 
with 30 I/O 
Points
2064_lu_1_3
100 to 
240 
VAC
1812Relay2K 
steps
2K words0.30.170.07CP1E-E30SDR-ACE
E[][]S-type 
CPU Units 
with 40 I/O 
Points
2064_lu_1_4
100 to 
240 
VAC
2416Relay2K 
steps
2K words0.30.170.09CP1E-E40SDR-ACE
E[][]S-type 
CPU Units 
with 60 I/O 
Points
2064_lu_1_5
100 to 
240 
VAC
3624Relay2K 
steps
2K words0.30.170.13CP1E-E60SDR-ACE

Normal-type

E[][]-type CP1E CPU Units (Built-in USB port)

Product 
name
SpecificationsEx- 
ternal 
power 
supply 
(24 
VDC) 
(A)
Current 
consump- 
tion (A)
ModelStand- 
ards
Power 
Supply
In- 
puts
Out- 
puts
Output 
type
Pro- 
gram 
ca- 
pacity
Data 
mem- 
ory 
ca- 
pacity
5 V24 V
E[][]-type 
CPU Units 
with 10 
I/O Points
2064_lu_5_1
100 to 
240 
VAC
64Relay2K 
steps
2K 
words
---0.080.04CP1E-E10DR-AUC1, 
N, L, 
CE
Transistor 
(sinking)
---0.11---CP1E-E10DT-A
Transistor 
(sourcing)
---0.11---CP1E-E10DT1-A
24 VDCRelay---0.080.04CP1E-E10DR-D
Transistor 
(sinking)
---0.11---CP1E-E10DT-D
Transistor 
(sourcing)
---0.11---CP1E-E10DT1-D
E[][]-type 
CPU Units 
with 14 
I/O Points
2064_lu_5_2
100 to 
240 
VAC
86Relay2K 
steps
2K 
words
---0.160.07CP1E-E14DR-AUC1, 
N, L, 
CE
E[][]-type 
CPU Units 
with 20 
I/O Points
2064_lu_5_3
100 to 
240 
VAC
128Relay2K 
steps
2K 
words
---0.170.08CP1E-E20DR-AUC1, 
N, L, 
CE
E[][]-type 
CPU Units 
with 30 
I/O Points
2064_lu_5_4
100 to 
240 
VAC
1812Relay2K 
steps
2K 
words
0.30.170.07CP1E-E30DR-AUC1, 
N, L, 
CE
E[][]-type 
CPU Units 
with 40 
I/O Points
2064_lu_5_5
100 to 
240 
VAC
2416Relay2K 
steps
2K 
words
0.30.170.09CP1E-E40DR-AUC1, 
N, L, 
CE

Application Model

Renewal-type

N[][]S1-type CP1E CPU Units (Built-in RS-232C, RS-485, USB ports)

Product 
name
SpecificationsEx- 
ternal 
power 
supply 
(24 
VDC) 
(A)
Current 
consump- 
tion (A)
ModelStand- 
ards
Power 
Supply
In- 
puts
Out- 
puts
Output 
type
Pro- 
gram 
ca- 
pacity
Data 
mem- 
ory 
ca- 
pacity
5 V24 V
N[][]S1- 
type CPU 
Units 
with 30 
I/O Points
2064_lu_2_1
100 to 
240 
VAC
1812Relay8K 
steps
8K 
words
0.30.210.07CP1E-N30S1DR-ACE
DC24VTransistor 
(sinking)
--0.270.02CP1E-N30S1DT-D
Transistor 
(sourcing)
--0.270.02CP1E-N30S1DT1-D
N[][]S1- 
type CPU 
Units 
with 40 
I/O Points
2064_lu_2_2
100 to 
240 
VAC
2416Relay8K 
steps
8K 
words
0.30.210.09CP1E-N40S1DR-ACE
DC24VTransistor 
(sinking)
--0.310.02CP1E-N40S1DT-D
Transistor 
(sourcing)
--0.310.02CP1E-N40S1DT1-D
N[][]S1- 
type CPU 
Units 
with 60 
I/O Points
2064_lu_2_3
100 to 
240 
VAC
3624Relay8K 
steps
8K 
words
0.30.210.13CP1E-N60S1DR-ACE
DC24VTransistor 
(sinking)
--0.310.02CP1E-N60S1DT-D
Transistor 
(sourcing)
--0.310.02CP1E-N60S1DT1-D

N[][]S-type CP1E CPU Units (Built-in RS-232C, USB ports)

Product 
name
SpecificationsEx- 
ternal 
power 
supply 
(24 
VDC) 
(A)
Current 
consump- 
tion (A)
ModelStand- 
ards
Power 
Supply
In- 
puts
Out- 
puts
Output 
type
Pro- 
gram 
ca- 
pacity
Data 
mem- 
ory 
ca- 
pacity
5 V24 V
N[][]S- 
type CPU 
Units 
with 30 
I/O Points
2064_lu_3_1
100 to 
240 
VAC
1812Relay8K 
steps
8K 
words
0.30.210.07CP1E-N30SDR-ACE
DC24VTransistor 
(sinking)
--0.270.02CP1E-N30SDT-D
Transistor 
(sourcing)
--0.270.02CP1E-N30SDT1-D
N[][]S- 
type CPU 
Units 
with 40 
I/O Points
2064_lu_3_2
100 to 
240 
VAC
2416Relay8K 
steps
8K 
words
0.30.210.09CP1E-N40SDR-ACE
DC24VTransistor 
(sinking)
--0.310.02CP1E-N40SDT-D
Transistor 
(sourcing)
--0.310.02CP1E-N40SDT1-D
N[][]S- 
type CPU 
Units 
with 60 
I/O Points
2064_lu_3_3
100 to 
240 
VAC
3624Relay8K 
steps
8K 
words
0.30.210.13CP1E-N60SDR-ACE
DC24VTransistor 
(sinking)
--0.310.02CP1E-N60SDT-D
Transistor 
(sourcing)
--0.310.02CP1E-N60SDT1-D

Normal-type

N/NA[][]-type CP1E CPU Units (Built-in RS-232C, USB ports)

Product 
name
SpecificationsEx- 
ternal 
power 
supply 
(24 
VDC) 
(A)
Current 
consump- 
tion (A)
ModelStand- 
ards
Pow- 
er 
Sup- 
ply
In- 
puts
Out- 
puts
Output 
type
Pro- 
gram 
ca- 
pacity
Data 
mem- 
ory 
ca- 
pacity
5 V24 V
N[][]-type 
CPU Units 
with 14 
I/O Points
2064_lu_6_1
100 
to 
240 
VAC
86Relay8K 
steps
8K 
words
---0.170.07CP1E-N14DR-AUC1, 
N, L, 
CE
Transistor 
(sinking)
---0.220.02CP1E-N14DT-A
Transistor 
(sourcing)
---0.220.02CP1E-N14DT1-A
24 
VDC
Relay---0.170.07CP1E-N14DR-D
Transistor 
(sinking)
---0.220.02CP1E-N14DT-D
Transistor 
(sourcing)
---0.220.02CP1E-N14DT1-D
N[][]-type 
CPU Units 
with 20 
I/O Points
2064_lu_6_2
100 
to 
240 
VAC
128Relay8K 
steps
8K 
words
---0.180.08CP1E-N20DR-AUC1, 
N, L, 
CE
Transistor 
(sinking)
---0.230.02CP1E-N20DT-A
Transistor 
(sourcing)
---0.230.02CP1E-N20DT1-A
24 
VDC
Relay---0.180.08CP1E-N20DR-D
Transistor 
(sinking)
---0.230.02CP1E-N20DT-D
Transistor 
(sourcing)
---0.230.02CP1E-N20DT1-D
N[][]-type 
CPU Units 
with 30 
I/O Points
2064_lu_6_3
100 
to 
240 
VAC
1812Relay8K 
steps
8K 
words
0.30.210.07CP1E-N30DR-AUC1, 
N, L, 
CE
Transistor 
(sinking)
0.30.270.02CP1E-N30DT-A
Transistor 
(sourcing)
0.30.270.02CP1E-N30DT1-A
24 
VDC
Relay---0.210.07CP1E-N30DR-D
Transistor 
(sinking)
---0.270.02CP1E-N30DT-D
Transistor 
(sourcing)
---0.270.02CP1E-N30DT1-D
N[][]-type 
CPU Units 
with 40 
I/O Points
2064_lu_6_4
100 
to 
240 
VAC
2416Relay8K 
steps
8K 
words
0.30.210.09CP1E-N40DR-AUC1, 
N, L, 
CE
Transistor 
(sinking)
0.30.310.02CP1E-N40DT-A
Transistor 
(sourcing)
0.30.310.02CP1E-N40DT1-A
24 
VDC
Relay---0.210.09CP1E-N40DR-D
Transistor 
(sinking)
---0.310.02CP1E-N40DT-D
Transistor 
(sourcing)
---0.310.02CP1E-N40DT1-D
N[][]-type 
CPU Units 
with 60 
I/O Points
2064_lu_6_5
100 
to 
240 
VAC
3624Relay8K 
steps
8K 
words
0.30.210.13CP1E-N60DR-AUC1, 
N, L, 
CE
Transistor 
(sinking)
0.30.310.02CP1E-N60DT-A
Transistor 
(sourcing)
0.30.310.02CP1E-N60DT1-A
24 
VDC
Relay---0.210.13CP1E-N60DR-D
Transistor 
(sinking)
---0.310.02CP1E-N60DT-D
Transistor 
(sourcing)
---0.310.02CP1E-N60DT1-D
NA-type 
CPU Units 
with 20 
I/O Points 
(Built-in 
analog)
2064_lu_6_6
100 
to 
240 
VAC
12 
(Built- 
in 
ana- 
log 
in- 
puts: 
2)

(Built- 
in 
ana- 
log 
out- 
puts: 
1)
Relay8K 
steps
8K 
words
0.30.180.11CP1E-NA20DR-AUC1, 
N, L, 
CE
24 
VDC
Transistor 
(sinking)
---0.230.09CP1E-NA20DT-D
Transistor 
(sourcing)
---0.230.09CP1E-NA20DT1-D

Optional Products

Battery Set

Product 
name
SpecificationsModelStand- 
ards
Battery Set
2064_lu_7_1
For N/NA[][](S[])-type CP1E CPU Units 
Note: Mount a Battery to an N/NA[][](S[])-type CPU Unit if the data in the 
following areas must be backed up for power interruptions. 
DM Area (D) (except backed up words in the DM Area), Holding Area (H), 
Counter Completion Flags (C), Counter Present Values (C), Auxiliary Area (A), 
and Clock Function 
(Use batteries within two years of manufacture.)
CP1W-BAT01--

Option Board (for CP1E N30/40/60 or NA20 CPU Units)

The Options cannot be used for CP1E N14/20, N30/40/60S(1), E10/14/20/30/40/60(S) CPU Units.
Product nameSpecificationsModelStand- 
ards
RS-232C 
Option Board
2064_lu_8_1One RS-232C Option Board can be mounted to the 
Option Board slot. 
One RS-232C connector is included.
CP1W-CIF01UC1, 
N, L, 
CE
RS-422A/485 
Option Board
2064_lu_8_2One RS-422A/485 Option Board can be mounted to the 
Option Board slot.
CP1W-CIF11
RS-422A/485 
Isolated-type 
Option Board
2064_lu_8_3CP1W-CIF12
Ethernet 
Option Board
2064_lu_8_4One Ethernet Option Board can be mounted to the 
Option Board slot. 
CP1E CPU Units are supported by CP1W-CIF41 
version 2.0 or higher. 
When using CP1W-CIF41, CX-Programmer version 
9.12 or higher is required.
CP1W-CIF41
Analog Input 
Option Board
2064_lu_8_5Can be mounted in CPU Unit Option Board slot. 
2 analog inputs. 0-10V(Resolution:1/4000), 0-20mA 
(Resolution:1/2000).
CP1W-ADB21 *
Analog Output 
Option Board
2064_lu_8_6Can be mounted in CPU Unit Option Board slot. 
2 analog outputs. 0-10V (Resolution:1/4000).
CP1W-DAB21V *
Analog I/O 
Option Board
2064_lu_8_7Can be mounted in CPU Unit Option Board slot. 
2 analog inputs. 0-10V(Resolution:1/4000), 0-20mA 
(Resolution:1/2000). 
2 analog outputs. 0-10V (Resolution:1/4000).
CP1W-MAB221 *
Note: It is not possible to use a CP-series Ethernet Option Board version 1.0 (CP1W-CIF41), LCD Option Board (CP1W- 
          DAM01), or Memory Card (CP1W-ME05M) with a CP1E CPU Unit. 
* Support is provided with CP1E CPU Unit version 1.2 and later.

Expansion I/O Units and Expansion Units (for CP1E E30/40/60(S), N30/40/60(S[]), or NA20 CPU Units)

CP1E E10/14/20(S) or N14/20 CPU Units do not support Expansion I/O Units and Expansion Units.
Unit 
type
Product 
name
SpecificationsCurrent 
consump- 
tion (A)
ModelStand- 
ards
In- 
puts
Out- 
puts
Output type5 V24 V
CP1W 
Expan- 
sion 
I/O 
Units
Input Unit 
2064_lu_11_1
8---24 VDC Input0.018--CP1W-8EDU, C, 
N, L, 
CE
Output Units 
2064_lu_11_2
---8Relay0.0260.044CP1W-8ER
Transistor (sinking)0.075--CP1W-8ET
Transistor (sourcing)0.075--CP1W-8ET1
Output Units 
2064_lu_11_3
---16Relay0.0420.090CP1W-16ERN, L, 
CE
Transistor (sinking)0.076--CP1W-16ET
Transistor (sourcing)0.076--CP1W-16ET1
Output Units 
2064_lu_11_4
---32Relay0.0490.131CP1W-32ERN, L, 
CE
Transistor (sinking)0.113--CP1W-32ET
Transistor (sourcing)0.113--CP1W-32ET1
I/O Units 
2064_lu_11_5
128Relay0.1030.044CP1W-20EDR1U, C, 
N, L, 
CE
Transistor (sinking)0.130--CP1W-20EDT
Transistor (sourcing)0.130--CP1W-20EDT1
I/O Units 
2064_lu_11_6
2416Relay0.0800.090CP1W-40EDRN, L, 
CE
Transistor (sinking)0.160--CP1W-40EDT
Transistor (sourcing)0.160--CP1W-40EDT1
CP1W 
Expan- 
sion 
Units
Analog 
Input Unit 
2064_lu_11_7
4CH--Input range: 
0 to 5 V, 1 to 5 V, 
0 to 10 V, ±10 V, 
0 to 20 mA, 
or 4 to 20 mA.
Resolution: 
1/6000
0.1000.090CP1W-AD041UC1, 
N, L, 
CE
Resolution: 
1/12000
0.1000.050CP1W-AD042UC1, 
N, CE
Analog 
Output Unit 
2064_lu_11_8
--2CHOutput range: 
1 to 5 V, 0 to 
10 V, ±10 V, 
0 to 20 mA, 
or 4 to 20 mA.
Resolution: 
1/6000
0.0400.095CP1W-DA021UC1, 
N, L, 
CE
--4CHResolution: 
1/6000
0.0800.124CP1W-DA041
Resolution: 
1/12000
0.0700.160CP1W-DA042UC1, 
N, CE
Analog 
I/O Unit 
2064_lu_11_9
4CH4CHInput range: 
0 to 5 V, 1 to 5 V, 
0 to 10 V, ±10 V, 
0 to 20 mA, or 
4 to 20 mA. 
Output range: 
1 to 5 V, 0 to 10 V, 
±10 V, 0 to 20 mA, 
or 4 to 20 mA.
Resolution: 
1/12000
0.1200.170CP1W-MAD44UC1, 
N, CE
4CH2CHResolution: 
1/12000
0.1200.120CP1W-MAD42
2CH1CHResolution: 
1/6000
0.0830.110CP1W-MAD11UC1, 
N, L, 
CE
Temperature 
Sensor Unit 
2064_lu_11_10
2CH--Sensor type: Thermocouple 
(J or K)
0.0400.059CP1W-TS001UC1, 
N, L, 
CE
4CH--Sensor type: Thermocouple 
(J or K)
0.0400.059CP1W-TS002
2CH--Sensor type: Platinum resistance 
thermometer (Pt100 or JPt100)
0.0540.073CP1W-TS101
4CH--Sensor type: Platinum resistance 
thermometer (Pt100 or JPt100)
0.0540.073CP1W-TS102
4CH--Sensor type: 
Thermocouple 
(J or K) 
2channels can be 
used as analog input. 
Input range: 
1 to 5 V, 0 to 10 V, 
4-20 mA
Resolution: 
1/12000
0.0700.030CP1W-TS003UC1, 
N, CE
12CH--Sensor type: Thermocouple 
(J or K)
0.0800.050CP1W-TS004
CompoBus/S 
I/O Link Unit 
2064_lu_11_11
88CompoBus/S slave0.029--CP1W-SRT21UC1, 
N, L, 
CE

I/O Connecting Cable

Product nameSpecificationsModelStandards
I/O Connecting Cable80 cm (for CP1W Expansion I/O Units and Expansion Units) 
Only one I/O Connecting Cable can be used in each PLC.
CP1W-CN811UC1, N, 
L, CE
Note: An I/O Connecting Cable (approx. 6 cm) for horizontal connection is provided with CP1W Expansion I/O Units and 
          Expansion Units.

DIN Track Accessories

NameSpecificationsModelStandards
DIN TrackLength: 0.5 m; Height: 7.3 mmPFP-50N--
Length: 1 m; Height: 7.3 mmPFP-100N
Length: 1 m; Height: 16 mmPFP-100N2
End PlateA stopper to secure the Units on the DIN Track.PFP-M

Programming Devices

Software

Product 
name
SpecificationsModelStand- 
ards
Number 
of 
licenses
Media
FA Integrated 
Tool Package 
CX-One Lite 
Ver.4.[]
CX-One Lite is a subset of the complete CX-One 
package that provides only the Support Software 
required for micro PLC applications. 
CX-One Lite runs on the following OS. 
OS: Windows XP (Service Pack 3 or higher, 32-bit 
version)/Windows Vista (32-bit/64-bit version)/ 
Windows 7 (32-bit/64-bit version)/Windows 8 (32- 
bit/64-bit version)/Windows 8.1 (32-bit/64-bit 
version) 
CX-One Lite Ver. 4.[] includes Micro PLC Edition 
CX-Programmer Ver.9.[].
1 licenseCDCXONE-LT01C-V4---
FA Integrated 
Tool Package 
CX-One 
Package 
Ver. 4.[]
CX-One is a comprehensive software package that 
integrates Support Software for OMRON PLCs and 
components. CX-One runs on the following OS. 
OS: Windows XP (Service Pack 3 or higher, 32-bit 
version)/Windows Vista (32-bit/64-bit version)/ 
Windows 7 (32-bit/64-bit version)/Windows 8 (32- 
bit/64-bit version)/Windows 8.1 (32-bit/64-bit 
version) 
CX-One Ver. 4.[] includes CX-Programmer Ver. 9.[].
1 license 
*
DVDCXONE-AL01D-V4---
Note: 1. The E20/30/40(S), N20/N30/N40(S) CPU Units are supported by CX-Programmer version 8.2 or higher. 
              The E10, E14, N14, N60, and NA20 CPU Units are supported by CX-Programmer version 9.03 or higher. When 
              Micro PLC Edition CXProgrammer is used, you need version 9.03 or higher. 
              The E60S CPU Units are supported by CX-Programmer version 9.42 or higher. When Micro PLC Edition CX- 
              Programmer is used, you need version 9.42 or higher. 
           2. The CX-One and CX-One Lite cannot be simultaneously installed on the same computer. 
* Multi licenses are available for the CX-One (3, 10, 30 or 50 licenses).
The following tables lists the Support Software that can be installed from CX-One
Support Software in CX-OneCX-One Lite Ver.4.[]CX-One Ver.4.[]
Micro PLC Edition CX-ProgrammerVer.9.[]YesNo
CX-ProgrammerVer.9.[]NoYes
CX-IntegratorVer.2.[]YesYes
Switch Box UtilityVer.1.[]YesYes
CX-ProtocolVer.1.[]NoYes
CX-SimulatorVer.1.[]YesYes
CX-PositionVer.2.[]NoYes
CX-Motion-NCFVer.1.[]NoYes
CX-Motion-MCHVer.2.[]NoYes
CX-MotionVer.2.[]NoYes
CX-DriveVer.1.[]YesYes
CX-Process ToolVer.5.[]NoYes
Faceplate Auto-Builder for NSVer.3.[]NoYes
CX-DesignerVer.3.[]YesYes
NV-DesignerVer.1.[]YesYes
CX-ThermoVer.4.[]YesYes
CX-ConfiguratorFDTVer.1.[]YesYes
CX-FLnetVer.1.[]NoYes
Network ConfiguratorVer.3.[]YesYes
CX-ServerVer.4.[]YesYes

CP1E

Cost-Effective, Easy Application, Application to Many Systems

Exceptional Cost

Responding to Global Competition with More Device Control Possibilities

The CP1E provide high cost performance to further reduce costs by allowing you to select the optimal CPU Unit from the E[][]S-type Basic Models or N/[][]S(1)-type Application Models.
Windows is registered trademarks of Microsoft Corporation in the USA and other countries. 
Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.

Simple and User Friendly

Intuitive control with “Smart Input.”

Easy to use input editor with smart input function [All Models]

When you begin typing an instruction from the keyboard in Ladder Editor Mode,suggested instructions are displayed and the addresses are automatically entered.
Connecting lines are added automatically based on the cursor position, enabling intuitive ladder programming.

Easy Input Editor

Instruction and Address Input Assist Functions

CP1E Features 8
When you begin typing an instruction from the keyboard while in the Ladder Editor Window, suggested instructions are displayed. All you have to do is select the instruction from the list for easy input even if you do not remember the entire mnemonic.

Address Incrementing

CP1E Features 9
The address of the next operand, including input bits and output bits, is incremented by one and displayed as the default. This enables easily inputting consecutive addresses.

User-friendly Ladder Program Input

Automatic Connecting Line Insertion

CP1E Features 11
With the automatic connecting line insertion function the necessary connection is added automatically based on the curser position.

Automatic Column Insertion When Inserting Instructions

CP1E Features 12
The column is automatically inserted when an instruction is added even if the curser is above another instruction.

Easy to reuse ladder programming

Copying with Address Incrementing

CP1E Features 14
To create the same group of ladder instructions more than once with the address addition copy function, the instructions can be reused simply by inputting an address offset.

Intuitive Menu Structure

Intuitive Menu Display

CP1E Features 16
An intuitively designed menu structure makes it easy to see the overall system simply by looking at the menu for smooth operation without referring to a manual.

Only commercially available USB cables required [All Models]

All CP1E CPU Units use high-speed USB for the peripheral port. Support software (computers) can be connected using commercially available USB cables. Without the need for USB conversion cables or special cables, connection is easier and cable cost is low.
CP1E Features 17

The depth of CPU Units with RS-232C connectors is reduced by 20 mm [Renewal type]

6 mm slimmer than the normal type.
CP1E Features 18

Efficient and Effective

Flexibly handle even small-scale systems. 
Various Option Units available for increased expandability.

More Applications with AdvancedControl Capabilities and Functionality [Application Models]

The Application Models (CP1E-N[][]/N[][]S(1)) are equipped with high-speed counters, pulse outputs, and a built-in serial port(s). 
In addition, using the Expansion Unit and Option Board, you can control a wide range of devices.

Pulse Outputs [Models with transistor Output]

Two 100kHz pulse outputs for high-precision position control.
CP1E Features 21

High-speed Counters*

Control multiple axes with one PLC using the two 100kHz and four 10kHz, single-phase high-speed counters. 
* The Basic Models are equipped with six 10kHz, single-phase high-speed counters.

Modbus-RTU easy master

Specify Inverter speeds via RS-485
CP1E Features 23

Analog I/O Control

High-accuracy analog I/O control with a resolution 1/12,000. 
You can add up to 4 analog I/O by mounting an Analog Option Board and up to 24 analog I/O by connecting Expansion Units.
CP1E Features 24

Temperature Control

The combination of the Temperature Input Unit with the PID instructions enables temperature control. 
Up to 12 thermocouple inputs per Unit for CP1W-TS004.
CP1E Features 25
The CP1W-TS003 has two inputs that can be used for temperature sensor or analog inputs. 
Both temperature sensor and analog inputs can be achieved with only one Unit.
CP1E Features 26

Serial PLC Links

Link data with up to 10 words between up to nine CP1E-N CPU Units when controlling a device with multiple CP1E-N PLCs.
CP1E Features 27

Ethernet Communications

Mount a CP1W-CIF41 Ethernet Option Board to an option board slot on the CP1E-N/NA type CPU Unit. 
Perform monitoring and programming with CX-Programmer,or communicate with a host computer via Ethernet.(server function only)
CP1E Features 28

Optional units for more flexibility

An option board for an additional Serial or Ethernet communication port can be added to the N30/40/60 and NA20 CPU Unit. Three expansion units are available. 
* The Option Board cannot be mounted to the CP1E-N□□S/N□□S1.

PLC Omron CJ2

Introducing the Flagship CJ2 CPU Units, with Built-in Multifunctional Ethernet Port.

Innovation without growing pains

As a modern machine manufacturer you need to continuously increase the intelligence and flexibility of your product to remain competitive. But you also need to be absolutely certain that it all works perfectly, first time, every time.
 
The CJ2 is the result of years of experience as market leader in the field of modular controllers and represents a logical next step in controller design. It offers greater performance and faster I/O response as well as extreme scalability - so you will only need one family. In addition, programming, debugging and networking are faster and easier.
Welcome to the new CJ2 Family: built to give you innovation without growing pains.
Although CJ2 is a can directly replace any CJ1 CPU, it offers the following additional significant advantages:

Open to the world

Data communication is via standard Ethernet port with EtherNet/IP Data Link function.

Advanced motion control

CJ2 units offer multi-axes synchronous control, and can replace expensive motion controllers.

High-speed

Faster program execution and immediate I/O refreshing enables flexible machine control.

Learn one, know them all

Thanks to the wide variety of CPUs with consistent architecture across all PLC families, you only need to learn one, and you will know them all.

Highly flexible

Adapt the PLC to your needs with the wide variety of compatible CJ1 Family I/O units (nearly 100)

CJ2M-CPU11
CJ2M-CPU12
CJ2M-CPU13
CJ2M-CPU31
CJ2M-CPU33
CJ2M-CPU34
CJ2M-CPU35


Selasa, 17 Mei 2016

PLC Mitsubishi FX1N Seri


FX1N-14MR-ES/UL
FX1N-14MT-ESS/UL
FX1N-24MR-ES/UL
FX1N-24MT-ESS/UL
FX1N -40MR-ES/UL
FX1N-40MT-ESS/UL
FX1N-60MR-ES/UL
FX1N-60MT-ESS/UL
FX1N-14MR-DS
FX1N-14MT-DSS
FX1N-24MR-DS
FX1N-40MR-DS
FX1N-40MT-DSS
FX1N-60MR-DS
FX1N-60MT-DSS


Features
  • Expandable terminal-type I/O
  • Add-on analog control and communication functionality
  • Integrated serial interface for communication with Personal computers and HMI
  • Input and output indicator LEDs
  • Detachable terminal blocks for all units
  • All DC powered models support 12V to 24V power supplies
  • Integrated real-time clock
  • System flexibility with expansion boards, special adapters, extension I/O, and special function blocks
Product Details
All-in-one CPU, power supply and I/O. Many expandability options including a display unit, I/O modules, expansion boards, special adapters, and special function modules.
Fast Instruction Times
Basic Instructions: 0.7µs / instruction (Contact Instruction). Applied Instructions: 3.7µs / instruction (MOV Instruction)
Large Memory
8,000 steps of built-in program memory. No battery. No maintenance.
Large Device Memory
Auxiliary Relays: 1,536 points
Timers: 256 points
Counters: 235 points
Data Registers: 8,000 points

PLC Mitsubishi FX1S


FX1S-10MR-ES/UL
FX1S-10MT-ESS/UL
FX1S-14MR-ES/UL
FX1S-14MT-ESS/UL
FX1S-20MR-ES/UL
FX1S-20MT-ESS/UL
FX1S-30MR-ES/UL
FX1S-30MT-ESS/UL
FX1S-10MR-DS
FX1S-10MT-DSS
FX1S-14MR-DS
FX1S-14MT-DSS
FX1S-20MR-DS
FX1S-20MT-DSS
FX1S-30MR-DS
FX1S-30MT-DSS

Features

  • Basic controller for general applications
  • High performance with minimal size
  • Integrated power supply (AC or DC powered)
  • Maintenance-free EEPROM memory
  • Ample memory capacity (2000 steps) and device ranges
  • High-speed operations
  • Built-in positioning control
  • Integrated real-time clock
  • Increased functionality using Expansion Boards and
    Special Adapters
  • Programming with GX Works2 or GX Developer
Product Details
All-in-one CPU, power supply and I/O. Expansion options includes a display unit and expansion boards for communication, analog control, or extra I/O.
Fast Instruction Times
Basic Instructions: 0.7µs / instruction (Contact Instruction)
Applied Instructions: 3.7µs / instruction (MOV Instruction)
Large Memory
2,000 steps of built-in program memory
No battery. No maintenance.
Large Device Memory
Auxiliary Relays: 512 points
Timers: 64 points
Counters: 32 points
Data Registers: 256 points





Senin, 16 Mei 2016

Pelatihan PLC & HMI



DATA PELATIHAN PLC 

Ketentuan : 

1. Setiap Pelatihan Minimal 4 Orang 

2. Setiap Pelatihan terdiri dari 4 x Pertemuan.


BASIC TRAINING PLC 

1. Dengan mengikuti Basic training PLC, peserta diharapkan mendapat manfaat:

- Mengetahui Jenis – jenis PLC yang banyak dipakai di Industri – industri Internasional.

- Mengetahui fungsi dan manfaat PLC, dimana ini sangat penting & paling dibutuhkan di Industri

- Tahu persis jenis PLC apa yang dibutuhkan perusahaan, terutama untuk mengefisiensi biaya.

2. Adapun rincian materi yang akan diberikan:

- Pengenalan PLC Compact 

- Komposisi PLC: Hardware & Software

- Sistem Konfigurasi PLC

- Fungsi, Karakteristik, dan Features PLC

- Pengalamatan & Alokasi I/O pada PLC.

- Pengenalan Diagram Ladder & Kode Memonik

- Pengenalan LCD Board & Software Programming

- Instruksi-instruksi Pemograman : TIM, CNT, SET/RESET, KEEP, DIFU/DIFD & IL/ILC.

- Contoh Aplikasi

3. Syarat Peserta :

- Mengenal PLC dan pernah/mengetahui wiring 
INTERMEDIATE PLC TRAINING 

1. Dengan mengikuti Basic training PLC, peserta diharapkan mendapat manfaat:

- Penguasaan tentang PLC tingkat tinggi

- Dapat mengkonfigurasi PLC Modular, terutama untuk kasus tertentu dimana dibutuhkan I/O yang sangat banyak.

- Mengkonfigurasi antara PLC dengan HMI, dimana saat ini banyak perusahaan – perusahaan yang mengganti perangkat konvensionalnya ke Touchscreen.


2. Adapun rincian materi yang akan diberikan:

- Pengenalan PLC Modular.

- Fungsi, karakteristik & Feature PLC Modular.

- Komposisi PLC : Hardware & Software

- Sistem Konfigurasi PLC

- Pengenalan, jenis dan fungsi HMI 

- Konfigurasi dan simulasi HMI

- Contoh Aplikasi PLC dengan HMI

3. Syarat Peserta :

- Mengetahui dasar – dasar PLC

- Pernah mengikuti training Basic PLC 
ADVANCE TRAINING PLC 

Peserta akan lebih mendalami PLC lebih tinggi lagi, dimana peserta akan dikenalkan bagaimana PLC di integrasikan secara jaringan ( network ) dan juga dikoneksikan dengan spesial I/O. Aplikasi ini banyak di gunakan pada mesin – mesin industri yang saat ini menjadi trend guna efisiensi baik secara instalasi maupun bahan materialnya

4. Pada training tingkat ini akan dibagi lagi menjadi 2 bagian, tergantung kebutuhan peserta. Adapun jenis paketnya yaitu:

- Advance PLC Special I/O

- Dapat mengkonfigurasi PLC Modular, terutama untuk kasus tertentu dimana dibutuhkan I/O yang sangat banyak.

5. Pada training ini peserta akan mendapatkan:

- Fungsi, karakteristik & Feature PLC Modular

- Komposisi PLC : Hardware & Software menggunakan special I/O

- Sistem Konfigurasi PLC menggunakan special I/O

- Contoh Aplikasi PLC dengan special I/O

6. Syarat Peserta :

- Mengetahui dasar – dasar PLC

- Pernah mengikuti training Basic PLC



- Pernah mendalami pengalamatan Memori PLC

Kamis, 12 Mei 2016

SCADA (Supervisory Control and Data Acquisition)



SCADA merupakan singkatan dari Supervisory Control and Data Acquisition. SCADA merupakan sebuah sistem yang mengumpulkan informasi atau data-data dari lapangan dan kemudian mengirimkan-nya ke sebuah komputer pusat yang akan mengatur dan mengontrol data-data tersbut. Sistem SCADA tidak hanya digunakan dalam proses-proses industri, misalnya, pabrik baja, pembangkit dan pendistribusian tenaga listrik (konvensional maupun nuklir), pabrik kimia, tetapi juga pada beberapa fasilitas eksperimen seperti fusi nuklir. Dari sudut pandang SCADA, ukuran pabrik atau sistem proses mulai dar 1.000an hingga 10.000an I/O (luara/masukan), namun saat ini sistem SCADA sudah bisa menangani hingga ratusan ribu I/O. 

Ada banyak bagian dalam sebuah sistem SCADA. Sebuah sistem SCADA biasanya memiliki perangkat keras sinyal untuk memperoleh dan mengirimkan I/O, kontroler, jaringan, antarmuka pengguna dalam bentuk HMI (Human Machine Interface), piranti komunikasi dan beberapa perangkat lunak pendukung. Semua itu menjadi satu sistem, istilah SCADA merujuk pada sistem pusat keseluruhan. Sistem pusat ini biasanya melakukan pemantauan data-data dari berbagai macam sensor di lapangan atau bahkan dari tempat2 yang lebih jauh lagi (remote locations).

Sistem pemantauan dan kontrol industri biasanya terdiri dari sebuah host pusat atau master (biasa dinamakan sebagai master station, master terminal unit atau MTU), satu atau lebih unit-unit pengumpul dan kontrol data lapangan (biasa dinamakan remote stattion, remoter terminal unit atau RTU) dan sekumpulan perangkat lunak standar maupun customized yang digunakan untuk memantau dan mengontrol elemen-elemen data-data di lapangan. Sebagian besar sistem SCADA banyak memiliki karakteristik kontrol kalang-terbuka (open-loop) dan banyak menggunakan komunikasi jarak jauh, walaupun demikian ada beberapa elemen merupakan kontrol kalang-tertutup (closed-loop) dan/atau menggunakan komunikasi jarak dekat.

Sistem yang mirip dengan sistem SCADA juga bisa kita jumpai di beberapa pabrik proses, perawatan dan lain-lain. Sistem ini dinamakan DCS (Distributed Control Systems). DCS memiliki fungsi yang mirip dengan SCADA, tetapi unit pengumpul dan pengontrol data biasanya ditempatkan pada beberapa area terbatas. Komunikasinya bisa menggunakan jaringan lokal (LAN), handal dan berkecepatan tinggi.

SCADA Pada Sistem Tenaga Listrik

Fasilitas SCADA diperlukan untuk melaksanakan pengusahaan tenaga listrik terutama pengendalian operasi secara realtime. Suatu sistem SCADA terdiri dari sejumlah RTU (Remote Terminal Unit), sebuah Master Station / RCC (Region Control Center), dan jaringan telekomunikasi data antara RTU dan Master Station. RTU dipasang di setiap Gardu Induk atau Pusat Pembangkit yang hendak dipantau. RTU ini bertugas untuk mengetahui setiap kondisi peralatan tegangan tinggi melalui pengumpulan besaran-besaran listrik, status peralatan, dan sinyal alarm yang kemudian diteruskan ke RCC melalui jaringan telekomunikasi data. RTU juga dapat menerima dan melaksanakan perintah untuk merubah status peralatan tegangan tinggi melalui sinyal-sinyal perintah yang dikirim dari RCC.

Dengan sistem SCADA maka Dispatcher dapat mendapatkan data dengan cepat setiap saat (real time) bila diperlukan, disamping itu SCADA dapat dengan cepat memberikan peringatan pada Dispatcher bila terjadi gangguan pada sistem, sehingga gangguan dapat dengan mudah dan cepat diatasi / dinormalkan. Data yang dapat diamati berupa kondisi ON / OFF peralatan transmisi daya, kondisi sistem SCADA sendiri, dan juga kondisi tegangan dan arus pada setiap bagian di komponen transmisi. Setiap kondisi memiliki indikator berbeda, bahkan apabila terdapat indikasi yang tidak valid maka operator akan dapat megetahui dengan mudah.

Fungsi kendali pengawasan mengacu pada operasi peralatan dari jarak jauh, seperti switching circuit breaker, pengiriman sinyal balik untuk menunjukkan atau mengindikasikan kalau operasi yang diinginkan telah berjalan efektif. Sebagai contoh pengawasan dilakukan dengan menggunakan indikasi lampu, jika lampu hijau menyala menunjukkan peralatan yang terbuka (open), sedang lampu merah menunjukkan bahwa peralatan tertutup (close), atau dapat menampilkan kondisi tidak valid yaitu kondisi yang tidak diketahui apakah open atau close. Saat RTU melakukan operasi kendali seperti membuka circuit breaker, perubahan dari lampu merah menjadi hijau pada pusat kendali menunjukkan bahwa operasi berjalan dengan sukses.

Operasi pengawasan disini memakai metode pemindaian (scanning) secara berurutan dari RTU-RTU yang terdapat pada Gardu Induk-Gardu Induk. Sistem ini mampu mengontrol beberapa RTU dengan banyak peralatan pada tiap RTU hanya dengan satu Master Station. Lebih lanjut, sistem ini juga mampu mengirim dari jarak jauh data-data hasil pengukuran oleh RTU ke Master Station, seperti data analog frekuensi, tegangan, daya dan besaran-besaran lain yang dibutuhkan untuk keseluruhan / kekomplitan operasi pengawasan .

Keuntungan sistem SCADA lainnya ialah kemampuan dalam membatasi jumlah data yang ditransfer antar Master Station dan RTU. Hal ini dilakukan melalui prosedur yang dikenal sebagai exception reporting dimana hanya data tertentu yang dikirim pada saat data tersebut mengalami perubahan yang melebihi batas setting, misalnya nilai frekuensi hanya dapat dianggap berubah apabila terjadi perubahan sebesar 0,05 Herzt. Jadi apabila terjadi perubahan yang nilainya sangat kecil maka akan dianggap tidak terjadi perubahan frekuensi. Hal ini adalah untuk mengantisipasi sifat histerisis sistem sehingga nilai frekuensi yang sebenarnya dapat dibaca dengan jelas.

Master Station secara berurutan memindai (scanning) RTU-RTU dengan mengirimkan pesan pendek pada tiap RTU untuk mengetahui jika RTU mempunyai informasi yang perlu dilaporkan. Jika RTU mempunyai sesuatu yang perlu dilaporkan, RTU akan mengirim pesan balik pada Master Station, dan data akan diterima dan dimasukkan ke dalam memori komputer. Jika diperlukan, pesan akan dicetak pada mesin printer di Master Station dan ditampilkan pada layar monitor.

Siklus pindai membutuhkan waktu relatif pendek, sekitar 7 detik (maksimal 10 detik). Siklus pindai yaitu pemindaian seluruh remote terminal dalam sistem. Ketika Master Station memberikan perintah kepada sebuah RTU, maka semua RTU akan menerima perintah itu, akan tetapi hanya RTU yang alamatnya sesuai dengan perintah itulah yang akan menjalankannya. Sistem ini dinamakan dengan sistem polling. Pada pelaksanaannya terdapat waktu tunda untuk mencegah kesalahan yang berkaitan dengan umur data analog.

Selain dengan sistem pemindaian, pertukaran data juga dapat terjadi secara incidental ( segera setelah aksi manuver terjadi ) misalnya terjadi penutupan switch circuit breaker oleh operator gardu induk, maka RTU secara otomatis akan segera mengirimkan status CB di gardu induk tersebut ke Master Station. Dispatcher akan segera mengetahui bahwa CB telah tertutup.

Ketika operasi dilakukan dari Master Station, pertama yang dilakukan adalah memastikan peralatan yang dipilih adalah tepat, kemudian diikuti dengan pemilihan operasi yang akan dilakukan. Operator pada Master Station melakukan tindakan tersebut berdasar pada prosedur yang disebut metode “select before execute (SBXC)“, seperti di bawah ini:

1.) Dispatcher di Master Station memilih RTU.

2.) Dispatcher memilih peralatan yang akan dioperasikan.

3.) Dispatcher mengirim perintah.

4.) Remote Terminal Unit mengetahui peralatan yang hendak dioperasikan.

5.) Remote Terminal Unit melakukan operasi dan mengirim sinyal balik pada Master Station ditunjukkan dengan perubahan warna pada layar VDU dan cetakan pesan pada printer logging.

Prosedur di atas meminimalkan kemungkinan terjadinya kesalahan operasi.

Jika terjadi gangguan pada RTU, pesan akan dikirim dari RTU yang mengalami gangguan tadi ke Master Station, dan pemindaian yang normal akan mengalami penundaan yang cukup lama karena Master Station mendahulukan pesan gangguan dan menyalakan alarm agar operator dapat mengambil tindakan yang diperlukan secepatnya. Pada saat yang lain, pada kebanyakan kasus, status semua peralatan pada RTU dapat dimonitor setiap 2 detik, memberikan informasi kondisi sistem yang sedang terjadi pada operator di Pusat Kendali (RCC).

Hampir semua sistem kendali pengawasan modern berbasis pada komputer, yang memungkinkan Master Station terdiri dari komputer digital dengan peralatan masukan keluaran yang dibutuhkan untuk mengirimkan pesan-pesan kendali ke RTU serta menerima informasi balik. Informasi yang diterima akan ditampilkan pada layar VDU dan/atau dicetak pada printer sebagai permanent records. VDU juga dapat menampilkan informasi grafis seperti diagram satu garis. Pada RCC (pusat kendali), seluruh status sistem juga ditampilkan pada Diagram Dinding (mimic board), yang memuat data mengenai aliran daya pada kondisi saat itu dari RTU.




Sumber : http://dunia-listrik.blogspot.co.id/2010/01/scada.html