Servo Motors and Servo Drives Selection Guide

Servo Motors and Servo Drives Selection Guide

 Model
Features
Rated Output
Supply Voltage (50/60 Hz)Input Command Signal
Nominal Torque
Nominal Speed Range

G5 Series
• Industry Fastest - 2kHz Bandwidth
• Safety conformance
• Real-time autotuning and advanced load vibration control.
• Double registration and full closed loop
• High-speed communication via EtherCAT communications.
50 W to 15 kW
Single phase/ three-phase, 200/240 VAC

Single phase, 100/120 VAC

Three phase, 200/230 VAC

Three phase, 380/480 VAC
R88D-KT:
Analog input/
pulse input selectable
R88D-KN[]-ML2:
MECHATROLINK-II
R88D-KN[]-ECT:
EtherCAT
0.16 N•m to
71.6 N•m
1000 rpm
2000 rpm
3000 rpm

G Series
• Support for a wide range of applications with position control, speed control, torque control.
• High-speed positioning via resonance suppression control.
• Command control mode switching.
• Simplified speed control with internal speed settings.
50 W to 7.5 kW
Single phase/ three-phase, 200/230 VAC

Single phase, 100 VAC
R88D-GT:
Analog input/
pulse input selectable
R88D-GN[]-ML2:
MECHATROLINK-II
0.16 N•m to
57.2 N•m
1000 rpm
1500 rpm
2000 rpm
3000 rpm
SmartStep2
• Compact AC Servo Drives.
• Vibration suppressed during acceleration/ deceleration of low-rigidity mechanisms.
• Resonance control for high-speed positioning.
• Compatible with 90° phase difference input command pulses.
• A wide range of pulse settings.
50 to 400 W
100 VAC

Single-phase/ three-phase 200 VAC

Single-phase 200 VAC
Pulse train inputs
0.16 N•m to
1.3 N•m
3000 rpm

Inverter OMRON

Inverter Selection Guide


 Item                                      Model
Appearance
3G3JX Variable Drives
3G3MX2 Variable Drives3G3RX Variable Drives

Power supply and capacity
Three-phase 200 V
0.2 to 7.5 kW
0.1 to 15 kW
0.4 to 55 kW
Single-phase/three-phase 200 V
0.2 to 2.2 kW
0.1 to 2.2 kW
None
Three-phase 400 V
0.4 to 7.5 kW
0.4 to 15 kW
0.4 to 132 kW
Control method
V/f control
Sensorless vector control
Vector control with a PG
Input/output
No. of multi-function I/O points
• 5 inputs
• 1 transistor output
• 1 relay output
• 7 inputs
• 2 transistor outputs
• 1 relay output
• 9 inputs (1 RUN (FWD)
input + 8 multi-function inputs)
• 5 transistor outputs
• 1 relay output
Analog I/O
• 1 input (0 to 10 V, 4 to 20 mA)
• 1 output (0 to 10 V)
• 2 inputs (0 to 10 V, 4 to 20 mA)
• 1 output (0 to 10 V)
• 2 inputs
(1) 0 to 10 V, 4 to 20 mA
(2) 0 to ±10 V

• 2 outputs
(1) 0 to 10 V
(2) 4 to 20 mA

• 1 PWM voltage output
Safety
Dual STO output 
 
EDM output 
 
Braking
Braking resistor connection
• (22 kW max.)
Regenerative Braking Unit connection
Regenerative Braking Unit + braking resistor connection
Frequency
Frequency setting range
0.5 to 400 Hz
0.1 to 400 Hz
0.1 to 400 Hz
Frequency output method
Line-to-line sine wave PWM

Installation and wiring
Side-by-side mounting
Removable terminal block
  
Power supply and motor wiring
Top/bottom wiring
Bottom wiring
Noise counter-measures
Radio noise filter
Standard feature (built-in)
Optional (external)
Standard feature (built-in)
I/O noise filter
Optional (external)
EMC filter
Optional (external)
Standard feature (built-in)
Operation
Digital Operator
Fixed Digital Operator (with adjustment dial)
Fixed Digital Operator
(without adjustment dial)
Removable Digital Operator
(without adjustment dial)
Autotuning
Main functions
Multistep speed control
16 steps + jog
Carrier frequency setting
2 to 12 kHz (default setting: 3 kHz)
2 to 15 kHz (default setting: 10 kHz)
2 to 15 kHz (default setting: 5 kHz)
Torque assist function
Manual + auto torque assist
Auto (simple)/manual torque assist
Auto/manual torque assist
PID function
Absolute value positioning
Emergency shutoff
0-Hz domain sensorless vector control
 
Tripless function
Momentary power interruption restart
Automatic energy saving
 
Communications
MODBUS-RTU
RoHS
Safety standards
CE
UL/cUL
PLd
(ISO 13849-1: 2006)

HMI NT Seri Omron

HMI
Basic Functional Series
Enhanced Basic Functional Series
5.7-inch
10.4-inch
3.1-inch
4.6-inch
3.6-inch
Mono/Color
Display size (mm)
118.2 × 89.4
211 × 158
70 × 35
109 × 41
71 × 53
Number of dots
320 × 240
640 × 480
128 × 64
320 × 120
320 × 240
Types of display
STN LCD
TFT LCD
STN LCD
Display color
Monochrome (2 color)
Color (8 color)
Monochrome 8 grayscale levels (NV4W)
Color (QVGA)
Types of graphic display
Straight lines, rectangles, polygons, circles, ovals, sector, bitmaps
Bitmaps (NV3W only), straight lines, continuous lines, rectangles, circles, ovals, circular arcs, oval arcs, sectors, oval sectors, and rounded rectangles
No. of character displayed
40 characters × 15 lines
80 characters × 30 lines
16 characters × 5 lines *40 characters × 10 lines *40 characters × 20 lines *
No. of registered screens
3,999
1,024
Screen data capacity
1 MB
384 kB
2 MB
Internal memory
Numeral memory table: 2000 entries max.,
Character memory table: 2000 entries max.
Recipe data: 8K
Recipe data: 65K
Write address: 65 K
Memory card interface
NT-MF261 Memory Unit for screen transfer--
SD Memory Card
(32 MB to 2 GB)
Backlight life
50,000 hours average
50,000 hours average
Ladder monitoring
---
Programming console
Supported
---
Barcode reader
Supported
---
Printer connection
Supported
---
Multi vendor
Supported
Communications
Hostlink, 1:1 NTLink, 1:N NTLink, Memory Link
Hostlink, 1:1 NTLink, Modbus RTU, EJ1 Temperature Controller
Software
CX-ONE software - NT Support Tools (NTST) software
NV-Designer
Standards
cUL, CE, LR
cUL, CE, RoHS, LR
cUL, CE, NK
UL508, EC Directives

HMI NS Seri Omron

HMI
Advanced Functional Series
5.7-inch
8.4-inch
10.4-inch
12.1-inch
15-inch
NS 15
Display size (mm)
117.2 × 88.4
170.9 × 128.2
215.2 × 162.4
246.0 × 184.5
304.1 × 228.1
Number of dots
320 × 240
640 × 480
800 × 600
1024 × 768
Types of display
TFT LCD
STN LCD
TFT LCD
Display color
256 colors
Image data: 32,768
16 grayscales
256 colors
Image data: 32,768
Types of graphic display
Straight lines, rectangles, polygons, circles, ovals, sector, bitmaps
No. of character displayed
80 characters × 30 lines
No. of registered screens
3,999
Screen data capacity
60 MB
Internal memory
Numeral memory table: 2000 entries max., Character memory table: 2000 entries max.
Memory card interface
Compact Flash Card for data storage and screen data transfer
Backlight life
75,000 hours min.
50,000 hours min.
40,000 hours min.
50,000 hours min.
Ladder monitoring
---
Supported
Programming console
Supported (CF card needed)
Supported
Barcode reader
Supported
Printer connection
Supported (pictbridge supported)
Multi vendor
Supported
Communications
Hostlink, 1:1 NTLink, 1:N NTLink, Memory Link, Ethernet (selective model), Omron Temperature Controller, Optional Controller Link Networking Card (NS10/NS12/NS15 only)
Software
CX-One software - CX-Designer
Standards
cUL, CE, RoHS, LR, NK

Industrial Network Selection Guide Selection Table & Selection Chart

By Selection Table:
                           Network Type
 Item
Information System Network
Control System Network
Field Network
Motion Field Network
Ethernet
Controller LinkSYSMAC Link CompoBus/SCompoNet
MECHA-TROLINK-II
Communi-cation Type
Message Commu-nication
O
O
O
O
---
O
O
Data Link
---
O
O
---
---
---
---
Remote I/O
---
---
---
O
O
O
---
Baud Rate (Maximum Communication Speed)
100 Mbps
2Mbps
Communication Cycle: Approx. 34ms;
(Wire: 32, 2kBit + 2kWord Data Link)
2Mbps
Communication Cycle: Approx. 34ms;
(Wire: 32, 2kBit + 2kWord Data Link)
500kbps
(Communication Cycle: Approx. 5ms;
(Input: 128 Point; Output: 128 Point)
750kbps
(Communication Cycle: 1ms and below;
(Input: 128 Point; Output: 128 Point)
4 Mbps at 30 m
10Mbps
Communication Distance
2.5 km
Twisted Pair: 3km;
H-PCF Optical Cable: 20km;
GI Optical Cable: 30km
Coaxial Cable: 1km;
Optical Fiber Cable: 10km
500m
Trunk length: 500m;
Communication Cycle: 6ms and below
1.5 km with max. 2 repeaters
Maximum 50m
Maximum Number of Nodes
254
62
62
63
32
384 nodes (word type=128 nodes; bit type=256 nodes)
30
Communication Medium
Coaxial Cable (10BASE-5)
or
Twisted Pair
(100BASE-TX/
10BASE-T)
Twisted Pair
or
Optical Fiber Cable
Coaxial Cable

Optical Fiber Cable
DeviceNet Cable
2 Core VCTF Cables,
4 Core VCTF Cables,
Flat Cable
Special 4 pair flat cable, round cable (VCTF, Belden)
METCHATROLINK-II Cable
Data Link Capacity (Per Network)
---
32000CH
2966CH
---
---
---
---
Maximum I/O Point
---
---
---
32000 Points (When Using Configurator);
15000 Points (When Not Using Configurator)
256 Points
2560 Points
---
PLC Type
C200HX/HG/HE
C200HX/HG/HE;
C200HS;
C1000H/C2000H
CJ Series;C200HX/HG/HE

By Selection Chart:
Fieldbus Network Solutions
* Click on the field network name to view details.

Ethernet Connection
Enables direct connection to personal computers or information networks with open protocol: Ethernet/IP or FINS protocol.

Controller Link (Fiber Optic)
High-speed Optical LAN with a transmission rate of 2 Mbps allows easy data exchange among PLC and a wide range of FA across 30 km.

Ethernet/IP
With Ethernet as the backbone architecture, optical switches can be used to extend network of 100 Mbps with easy data sharing among PLCs.

Controller Link (Wired)
Allows high-speed, large capacity data link with cost-saving wiring, data can be shared among 62 nodes in total.

PC Link (1:1, 1:N)
Easy and low-cost communication between PLCs of limited data capacity.

DeviceNet
Open network, which connects a variety of components such as drivers, temperature controller and etc. with Smart Features built with totalization and signal indication for maintenance.

CompoNet
Next generation network is ideal for high-speed ON/OFF bus for machinery system. With communication cycle time less than 1 ms connecting up to 1.5 km