Connecting Cables for CJ2
Computer | Unit | Network Type (Serial Communications Mode) | Model | Cable length | Con- nection Types | ||
PC port | Unit port | ||||||
PC/AT compatible | USB A plug connector (female) | CPU Unit | USB B plug connector (female) | USB or Toolbus (USB port) | Commercially available USB cable * (A plug connector (male) - B plug connector (male)) | 5 m maximum | A |
D-sub, 9-pin (male) | Built-in RS-232C port D-sub, 9-pin (female) | Host Link | XW2Z-500S-CV | 5 m | B | ||
XW2Z-200S-CV | 2 m |
*A driver must first be installed to make a USB connection.
Connecting Cables for CS1/CJ1
Computer | Unit | Network Type (Serial Communications Mode) | Model | Cable length | Con- nection Types | ||
PC port | Unit port | ||||||
PC/AT compatible | D-sub, 9-pin (male) | CPU | Built-in peripheral port | Peripheral bus or Host Link | CS1W-CN226 | 2 m | A |
CS1W-CN626 | 6 m | ||||||
CS1W-CN118 + XW2Z-200S-CV | 0.1 m + 2 m | B | |||||
CS1W-CN118 + XW2Z-500S-CV | 0.1m + 5 m | ||||||
Host Link | CS1W-CN118 + XW2Z-200S-V | 0.1 m + 2 m | |||||
CS1W-CN118 + XW2Z-500S-V | 0.1 m + 5 m | ||||||
Host Link with a baud rate of 19.2 kbps or less | CS1W-CN114 + CQM1-CIF02 | 0.05 m + 3.3 m | C | ||||
Built-in RS-232C port D-sub, 9-pin (female) | Peripheral bus or Host Link | XW2Z-200S-CV | 2 m | D | |||
XW2Z-500S-CV | 5 m | ||||||
Host Link | XW2Z-200S-V | 2 m | |||||
XW2Z-500S-V | 5 m |
Reference: USB-Serial Conversion Cable (CS1W-CIF31)
Computer | Connecting Cable | Network Type (Serial Communications Mode) | Model | Cable length | Con- nection Types | ||
PC port | Cable port | ||||||
PC/AT compatible | USB A plug connector (female) | --- | RS-232C D-sub, 9-pin (female) | Depends on the Unit's spcifications. | CS1W-CIF31 *2 | 0.5 m | A |
*1Applicable models: CS/CJ Series, C Series (C200HS, C200HE/G/X, C200H, C1000H, C2000H, CQM1, CPM1, CPM1A, CPM2A, CQM1H, and CPM2C), CVM1/CV Series, NS Series, NT Series, SRM1, and ZEN.
*2.A separate cable is required to connect to the PLC.
Connecting Cables for CP1H/CP1L/CP1E
Computer | Unit | Network Type (Serial Communications Mode) | Model | Cable length | Con- nection Types | ||
PC port | Unit port | ||||||
PC/AT compatible | USB A plug connector (female) | CPU | USB B plug connector (female) | USB | Commercially available USB cable (A plug connector (male) - B plug connector (male)) | 5 m maximum | A |
D-sub, 9-pin (male) | RS-232C port (D-sub 9-pin female) on Option Board * D-sub, 9-pin (female) | Peripheral bus or Host Link | XW2Z-200S-CV | 2 m | B | ||
XW2Z-500S-CV | 5 m | ||||||
Host Link | XW2Z-200S-V | 2 m | |||||
XW2Z-500S-V | 5 m |
*An Option Board cannot be used with a CP1L CPU Unit with 10 Points and CP1E-E. Also, the CP1E-N and CP1E-NA have a built-in RS-232C port.
Connecting Cables for C200HS/HX/HG/HE
Computer | Unit | Network Type (Serial Communications Mode) | Model | Cable length | Con- nection Types | ||
PC port | Unit port | ||||||
PC/AT compatible | D-sub, 9-pin (male) | CPU | Built-in peripheral port | Peripheral bus *1 or Host Link | CQM1-CIF02 | 3.3 m | A |
Built-in RS-232C port D-sub, 9-pin (female) *2 | Host Link | XW2Z-200S-CV | 2 m | B | |||
XW2Z-500S-CV | 5 m | ||||||
XW2Z-200S-V | 2 m | ||||||
XW2Z-500S-V | 5 m | ||||||
Host Link Unit C200H-LK201-V1 | Built-in RS-232C port D-sub, 25-pin (female) | XW2Z-200P-V *3 | 2 m | C | |||
XW2Z-500P-V *3 | 5 m |
*1.These Cables cannot be used for Programming Devices, such as the CX-Programmer, for the C200H-LK201-V1 Host Link Unit on a C200HX/HG/HE-Z PLC.
*2.Only C200HS-CPU21/23/31/33 is equipped with a built-in RS-232C port D-sub, 9-pin (female).
*3.The XW2Z-200S-CV and XW2Z-500S-CV cannot be used.
Connecting Cables for CQM1H
Computer | Unit | Network Type (Serial Communications Mode) | Model | Cable length | Con- nection Types | ||
PC port | Unit port | ||||||
PC/AT compatible | D-sub, 9-pin (male) | CPU * | Built-in peripheral port | Peripheral bus or Host Link | CS1W-CN226 | 2 m | A |
CS1W-CN626 | 6 m | ||||||
CS1W-CN114 + CQM1-CIF02 | 0.05 m + 3.3 m | B | |||||
CS1W-CN118 + XW2Z-200S-CV | 0.1 m + 2 m | C | |||||
CS1W-CN118 + XW2Z-500S-CV | 0.1 m + 5 m | ||||||
CS1W-CN118 + XW2Z-200S-V | 0.1 m + 2 m | ||||||
CS1W-CN118 + XW2Z-500S-V | 0.1 m + 5 m | ||||||
Built-in RS-232C port D-sub, 9-pin (female) | Host Link | XW2Z-200S-CV | 2 m | D | |||
XW2Z-500S-CV | 5 m | ||||||
XW2Z-200S-V | 2 m | ||||||
XW2Z-500S-V | 5 m |
*Discontinuation models in March 2012.
Connecting Cables for CQM1
Computer | Unit | Network Type (Serial Communications Mode) | Model | Cable length | Con- nection Types | ||
PC port | Unit port | ||||||
PC/AT compatible | D-sub, 9-pin (male) | CPU * | Built-in peripheral port | Peripheral bus or Host Link | CQM1-CIF02 | 3.3 m | A |
Built-in RS-232C port D-sub, 9-pin (female) (CPU42/43/44/63/64/65/85 only) | Host Link | XW2Z-200S-CV | 2 m | B | |||
XW2Z-500S-CV | 5 m | ||||||
XW2Z-200S-V | 2 m | ||||||
XW2Z-500S-V | 5 m |
*Discontinuation models in March 2001.
Connecting Cables for CPM1, CPM1A and CPM2A
Computer | Unit | Network Type (Serial Communications Mode) | Model | Cable length | Con- nection Types | ||
PC port | Unit port | ||||||
PC/AT compatible | D-sub, 9-pin (male) | CPU Unit | Built-in peripheral port | Peripheral bus * or Host Link | CQM1-CIF02 | 3.3 m | A |
CPM1-CIF01 + XW2Z-200S-CV | 2 m | B | |||||
CPM1-CIF01 + XW2Z-500S-CV | 5 m | ||||||
Host Link | CPM1-CIF01 + XW2Z-200S-V | 2 m | |||||
CPM1-CIF01 + XW2Z-500S-V | 5 m |
*CPM2A CPU Units that have a 9 as the fourth digit of the lot number (4 or 5 digits) do not support Toolbus connections. They do support Host Link connections.
Connecting Cables for SRM1
Computer | Unit | Network Type (Serial Communications Mode) | Model | Cable length | Con- nection Types | ||
PC port | Unit port | ||||||
PC/AT compatible | D-sub, 9-pin (male) | CPU Unit | Built-in peripheral port | Peripheral bus or Host Link | CQM1-CIF02 | 3.3 m | A |
CPM1-CIF01 + XW2Z-200S-CV | 2 m | B | |||||
CPM1-CIF01 + XW2Z-500S-CV | 5 m | ||||||
Host Link | CPM1-CIF01 + XW2Z-200S-V | 2 m | |||||
CPM1-CIF01 + XW2Z-500S-V | 5 m | ||||||
Built-in RS-232C port D-sub, 9-pin (female) (SRM1-C01 only) | XW2Z-200S-CV | 2 m | C | ||||
XW2Z-500S-CV | 5 m | ||||||
XW2Z-200S-V | 2 m | ||||||
XW2Z-500S-V | 5 m |
Connecting Cables for CPM2C
Computer | Unit | Network Type (Serial Communications Mode) | Model | Cable length | Con- nection Types | ||
PC port | Unit port | ||||||
PC/AT compatible | D-sub, 9-pin (male) | CPU | Communications port (as a peripheral port) | Peripheral bus *1 or Host Link | CS1W-CN226 *2 | 2 m | A |
CS1W-CN626 *2 | 6 m | ||||||
CS1W-CN114 + CQM1-CIF02 | 0.05 m + 3.3 m | B | |||||
CPM2C-CIF01-V1 + CS1W-CN114 + CQM1-CIF02 | Adapter + 0.05 m + 3.3 m | C | |||||
CPM2C-CN111 (Peripheral port) + CQM1-CIF02 | 0.1 m + 3.3 m | D | |||||
Communications port (as an RS-232C port) | Host Link | CS1W-CN118 + XW2Z-200S-CV | 0.1 m + 2 m | E | |||
CS1W-CN118 + XW2Z-500S-CV | 0.1 m + 5 m | ||||||
CS1W-CN118 + XW2Z-200S-V | 0.1 m + 2 m | ||||||
CS1W-CN118 + XW2Z-500S-V | 0.1 m + 5 m | ||||||
CPM2C-CN111 (RS-232C port) + XW2Z-200S-CV | 0.1m + 2m | F | |||||
CPM2C-CN111 (RS-232C port) + XW2Z-500S-CV | 0.1 m + 5 m | ||||||
CPM2C-CN111 (RS-232C port) + XW2Z-200S-V | 0.1 m + 2 m | ||||||
CPM2C-CN111 (RS-232C port) + XW2Z-500S-V | 0.1 m + 5 m | ||||||
CPM2C-CIF01-V1 + XW2Z-200S-CV | Adapter + 2 m | G | |||||
CPM2C-CIF01-V1 + XW2Z-500S-CV | Adapter + 5 m | ||||||
CPM2C-CIF01-V1 + XW2Z-200S-V | Adapter + 2 m | ||||||
CPM2C-CIF01-V1 + XW2Z-500S-V | Adapter + 5 m | ||||||
CPM2C-CIF01-V1 + CS1W-CN118 + XW2Z-200S-CV | Adapter + 0.1 m + 2 m | H | |||||
CPM2C-CIF01-V1 + CS1W-CN118 + XW2Z-500S-CV | Adapter + 0.1 m + 5 m | ||||||
CPM2C-CIF01-V1 + CS1W-CN118 + XW2Z-200S-V | Adapter + 0.1 m + 2 m | ||||||
CPM2C-CIF01-V1 + CS1W-CN118 + XW2Z-500S-V | Adapter + 0.1 m + 5 m | ||||||
CPM2C-CIF11 + XW2Z-200S-V | Adapter + 2 m | I | |||||
CPM2C-CIF11 + XW2Z-500S-V | Adapter + 5 m | ||||||
CPM2C-CIF21 + XW2Z-200S-V | Adapter + 2 m | ||||||
CPM2C-CIF21 + XW2Z-500S-V | Adapter + 5 m |
*1.CPM2C CPU Units that have a 9 as the fourth digit of the lot number (4 or 5 digits) and that were manufactured in 1999 do not support Toolbus connections. They do support Host Link connections.
*2.Only Host Link (SYSMAC WAY) connections are possible. Toolbus cannot be used.
Connecting Cables for C1000H, C2000H, C200H
Computer | Unit | Network Type (Serial Communications Mode) | Model | Cable length | Con- nection Types | ||
PC port | Unit port | ||||||
PC/AT compatible | D-sub, 9-pin (male) | CPU Unit | Built-in peripheral port | Host Link | C200H-IP007 + CQM1-CIF02 * | 3.3 m | A |
Host Link Unit C1000H, C2000H: C500-LK203 C500-LK201-V1 (3G2A5-LK201-V1) C120-LK201-V1 (3G2A6-LK201-EV1) C200H: C200H-LK201-V1 C120-LK201-V1 (3G2A6-LK201-EV1) | Built-in RS-232C port D-sub, 25-pin (female) | XW2Z-200P-V | 2 m | B | |||
XW2Z-500P-V | 5 m |
*Connection cannot be made from the CQM1-CIF02 directly to a computer for the C200H Handheld Programming Console connecting cable. Use the C200H-IP007.
Connecting Cables for CVM1/CV
Computer | Unit | Network Type (Serial Communications Mode) | Model | Cable length | Con- nection Types | ||
PC port | Unit port | ||||||
PC/AT compatible | D-sub, 9-pin (male) | CPU Unit *1 | Built-in peripheral port | Host Link | CV500-CIF01 *2 | 6 m | A |
Built-in RS-232C port D-sub, 9-pin (female) | XW2Z-200S-V *3 | 2 m | B | ||||
XW2Z-500S-V *3 | 5 m | ||||||
Host Link Unit CV500-LK201 *1 (for full duplex communication on port 1) | Built-in RS-232C port D-sub, 25-pin (female) | XW2Z-200P-V *3 | 2 m | C | |||
XW2Z-500P-V *3 | 5 m | ||||||
Host Link Unit CV500-LK201 *1 (for full duplex communication on port 2) | Built-in RS-232C port D-sub, 9-pin (female) | XW2Z-200S-V *3 | 2 m | D | |||
XW2Z-500S-V *3 | 5 m |
*1.Discontinuation models in March 2012.
*2.A commercially available 25-pin/9-pin straight conversion cable is separately required.
*3.The XW2Z-200S-CV and XW2Z-500S-CV cannot be used.
Connecting Cables for C500
Computer | Unit | Network Type (Serial Communications Mode) | Model | Cable length | Con- nection Types | ||
PC port | Unit port | ||||||
PC/AT compatible | D-sub, 9-pin (male) | CPU Unit *1 | Built-in peripheral port | Host Link | C200H-IP007 + CQM1-CIF02 | 3.3 m | A |
Host Link Unit *2 C500-LK203 C500-LK201-V1 (3G2A5-LK201-EV1) C120-LK201-V1 (3G2A6-LK201-EV1) | Built-in RS-232C port D-sub, 25-pin (female) | XW2Z-200P-V | 2 m | B | |||
XW2Z-500P-V | 5 m |
*1.Production of the CPU Units was discontinued in March 2004.
*2.Production of the C500-LK203, C500-LK201-V1 (3G2A5-LK201-EV1), and C120-LK201-V1 (3G2A6-LK201-EV1) was discontinued in March 2006. (There is no recommended substitute product.)
Connecting Cables for C120
Computer | Unit | Network Type (Serial Communications Mode) | Model | Cable length | Con- nection Types | ||
PC port | Unit port | ||||||
PC/AT compatible | D-sub, 9-pin (male) | CPU Unit *1 | Built-in peripheral port | Host Link | C200H-IP007 + CQM1-CIF02 | 3.3 m | A |
Host Link Unit *2 C120-LK201-V1 (3G2A6-LK201-EV1) | Built-in RS-232C port D-sub, 25-pin (female) | XW2Z-200P-V | 2 m | B | |||
XW2Z-500P-V | 5 m |
*1.Production of the CPU Units was discontinued in March 2003.
*2.Production of the C120-LK201-V1 was discontinued in March 2006. (There is no recommended substitute product.)
Connecting Cables for C20P/C28P/C40P/C60P*1, C20K/C28K/C40K/C60K*2
Computer | Unit | Network Type (Serial Communications Mode) | Model | Cable length | Con- nection Types | ||
PC port | Unit port | ||||||
PC/AT compatible | D-sub, 9-pin (male) | Host Link Unit *3 *4 C20-LK201-V1 (3G2C7-LK201-EV1) | Built-in RS-232C port D-sub, 25-pin (female) | Host Link | XW2Z-200P-V | 2 m | A |
XW2Z-500P-V | 5 m |
*1.Production of the C20P, C28P, C40P, and C60P CPU Units was discontinued in March 2002.
*2.Production of the C20K, C28K, C40K, and C60K CPU Units was discontinued in March 2002.
*3.For connection to C[][]P PLCs, a Host Link Unit is also required in addition to a Connecting Cable.
*4.Production of the C20-LK201-V1 (3G2C7-LK201-EV1) was discontinued in March 2006. (There is no recommended substitute product.)
Connecting Cables for NSJ
Computer | Unit | Network Type (Serial Communications Mode) | Model | Cable length | Con- nection Types | ||
PC port | Unit port | ||||||
PC/AT compatible | USB A plug connector (male) | CPU | USB B plug connector (female) | USB | Commercially available USB cable (A plug connector (male) - B plug connector (male)) | 5 m maximum | A |
D-sub, 9-pin (male) | Built-in RS-232C port D-sub, 9-pin (female) | Peripheral bus or Host Link | XW2Z-200S-CV | 2 m | B | ||
XW2Z-500S-CV | 5 m | ||||||
Host Link | XW2Z-200S-V | 2 m | |||||
XW2Z-500S-V | 5 m |