Spesifikasi |
- Engine 2000-2800cc segaris 6 silinder 12 valve , mesin mitsubisi, isuzu atau sejenis |
- Mesin 4 langkah |
- Sistem pendinginan air radiator |
- Sistem bahan bakar diesel injection pump dan injector (nozzle) |
- Tangki bahan bakar |
- Sistem starter |
- Sistem Pengisian |
- Sistem Pembuangan |
- Instrumen Kunci Kontak |
- Volt Meter |
- Amperemeter |
- Battery 12 V 70 Ah |
Kelengkapan |
Kerangka terbuat dari besi Hollow 4x6cm dan 4x4cm, Cat duco , Dengan kaki roda 4 dari nylon 2 lock dan 2 free. |
Panel dasboard dan plate name terbuat dari Acrilic grafir &cutting menggunakan engrafing Laser Machine |
OMRON , MITSUBISHI , DELTA , LS , WIINTEK WEINVIEW, VEICHI , FUJI ELECTRIC , PROFACE , FATEK , SIEMENS , CUTES , EMERSON , SHIHLIN ELECTRIC , SLANVERT , DANFOSS , MOXA , WACON, YASKAWA Etc
Kontak Kami
KONTAK KAMI : Telpon : 02126071413 Hp/WhatsApp : 081212269831
Perwakilan Jakarta : Gedung LTC Glodok Lantai 1 Blok C30 No.31 Jl.Hayam Wuruk No.127 Jakarta , Indonesia
Senin, 02 Januari 2017
JUAL DIESEL ENGINE TRAINER 6 SILINDER
JUAL DIESEL ENGINE TRAINER 4 SILINDER
Spesifikasi |
- Engine 2000cc segaris 4 silinder 8, mesin mitsubisi L300 |
- Mesin 4 langkah |
- Sistem pendinginan air radiator |
- Sistem bahan bakar diesel injection pump dan injector (nozzle) |
- Tangki bahan bakar |
- Sistem starter |
- Sistem Pengisian |
- Sistem Pembuangan |
- Instrumen Kunci Kontak |
- Volt Meter |
- Amperemeter |
- Battery 12 V 40 Ah |
Kelengkapan |
Kerangka terbuat dari besi Hollow 4x6cm dan 4x4cm, Cat duco , Dengan kaki roda 4 dari nylon 2 lock dan 2 free. |
Panel dasboard dan plate name terbuat dari Acrilic grafir &cutting menggunakan engrafing Laser Machine |
Jumat, 30 Desember 2016
Jual FX3S PLC Mitsubishi Melsec FX Series
FX3S PLC Mitsubishi Melsec F Series
FX3S - Keeping it Simple
FX3S - Keeping it Simple
Controllable I/O : 10 - 30 points
Main Unit I/O : 10/14/20/30 points
Main Unit I/O : 10/14/20/30 points
Fast Instruction Times
Basic Instructions : 0.21µs / Instruction (COntact Instruction)
Applied Instructions : 0.5µs / Instruction (MOV Instruction)
Basic Instructions : 0.21µs / Instruction (COntact Instruction)
Applied Instructions : 0.5µs / Instruction (MOV Instruction)
Large Memory
4000 steps of built-in program memory. No battery, no maintenance.
4000 steps of built-in program memory. No battery, no maintenance.
Large Device Memory
- Auxiliary Relays : 1,536 points
- Timers : 138 points
- Counters : 88 points
- Data Registers : 3,000 points
FX3S Main Units with 10 I/O
FX3S-10MR/DS : 24 VDC
FX3S-10MR/ES : 100-240 VAC
FX3S-10MT/DS : 24 VDC
FX3S-10MT/DSS : 24 VDC
FX3S-10MT/ES : 100-240 VAC
FX3S-10MT/ESS : 100-240 VAC
FX3S-10MR/DS : 24 VDC
FX3S-10MR/ES : 100-240 VAC
FX3S-10MT/DS : 24 VDC
FX3S-10MT/DSS : 24 VDC
FX3S-10MT/ES : 100-240 VAC
FX3S-10MT/ESS : 100-240 VAC
FX3S Main Units with 14 I/O
FX3S-14MR/DS : 24 VDC
FX3S-14MR/ES : 100-240 VAC
FX3S-14MT/DS : 24 VDC
FX3S-30MT/DSS : 24 VDC
FX3S-14MT/ES : 100-240 VAC
FX3S-14MT/ESS : 100-240 VAC
FX3S-14MR/DS : 24 VDC
FX3S-14MR/ES : 100-240 VAC
FX3S-14MT/DS : 24 VDC
FX3S-30MT/DSS : 24 VDC
FX3S-14MT/ES : 100-240 VAC
FX3S-14MT/ESS : 100-240 VAC
FX3S Main Units with 20 I/O
FX3S-20MR/DS : 24 VDC
FX3S-20MR/ES : 100-240 VAC
FX3S-20MT/DS : 24 VDC
FX3S-20MT/DSS : 24 VDC
FX3S-20MT/ES : 100-240 VAC
FX3S-20MT/ESS : 100-240 VAC
FX3S-20MR/DS : 24 VDC
FX3S-20MR/ES : 100-240 VAC
FX3S-20MT/DS : 24 VDC
FX3S-20MT/DSS : 24 VDC
FX3S-20MT/ES : 100-240 VAC
FX3S-20MT/ESS : 100-240 VAC
FX3S Main Units with 30 I/O
FX3S-30MR/DS : 24 VDC
FX3S-30MR/ES : 100-240 VAC
FX3S-30MT/DS : 24 VDC
FX3S-30MT/DSS : 24 VDC
FX3S-30MT/ES : 100-240 VAC
FX3S-30MT/ESS : 100-240 VAC
FX3S-30MR/DS : 24 VDC
FX3S-30MR/ES : 100-240 VAC
FX3S-30MT/DS : 24 VDC
FX3S-30MT/DSS : 24 VDC
FX3S-30MT/ES : 100-240 VAC
FX3S-30MT/ESS : 100-240 VAC
FX3S Main Units with 30 I/O and Analog Inputs
FX3S-30MR/ES-2AD : 100-240 VAC
FX3S-30MT/ES-2AD : 100-240 VAC
FX3S-30MT/ESS-2AD : 100-240 VAC
FX3S-30MR/ES-2AD : 100-240 VAC
FX3S-30MT/ES-2AD : 100-240 VAC
FX3S-30MT/ESS-2AD : 100-240 VAC
FX3S Feature
- High performance with minimal size
- Integrated power supply (AC powered)
- Maintenance-free EEPROM memory
- Ample memory capacity (4000 steps) and device ranges
- Built-in USB port for the programming communication function to enable high-speed communication at 12Mbps
- Built-in positioning control
- Integrated real-time clock
- Increased functionality using Expansion Boards and Special Adapters
- Programming with GX Works2 or GX Works2 FX
FX3S Main Units with 10 I/O
Model Number
|
FX3S-10MR/DS
|
FX3S-10MR/ES
|
FX3S-10MT/DS
|
FX3S-10MT/DSS
|
FX3S-10MT/ES
|
FX3S-10MT/ESS
|
Stocked Item
|
S
|
S
|
S
|
S
|
S
|
S
|
Rating
|
UL • cUL • CE (EMC)
| |||||
Integrated Inputs/Outputs
|
10
|
10
|
10
|
10
|
10
|
10
|
Power Supply (V)
|
24VDC
|
100 - 240VAC
|
24VDC
|
24VDC
|
100 - 240VAC
|
100 - 240VAC
|
Integrated Inputs
|
6
|
6
|
6
|
6
|
6
|
6
|
Integrated Outputs
|
4
|
4
|
4
|
4
|
4
|
4
|
Output Type
|
Relay
|
Relay
|
Transistor (Sink)
|
Transistor (Source)
|
Transistor (Sink)
|
Transistor (Source)
|
Power Consumption (W)
|
6
|
19
|
6
|
6
|
19
|
19
|
Weight (kg)
|
0.22
|
0.3
|
0.22
|
0.22
|
0.3
|
0.3
|
Dimensions (W x H x D) mm
|
60 x 90 x 75
|
60 x 90 x 75
|
60 x 90 x 49
|
60 x 90 x 49
|
60 x 90 x75
|
60 x 90 x75
|
FX3S Main Units with 14 I/O
Model Number
|
FX3S-14MR/DS
|
FX3S-14MR/ES
|
FX3S-14MT/DS
|
FX3S-30MT/DSS
|
FX3S-14MT/ES
|
FX3S-14MT/ESS
|
Stocked Item
|
S
|
S
|
-
|
S
|
S
|
S
|
Rating
|
UL • cUL • CE (EMC)
| |||||
Integrated Inputs/Outputs
|
10
|
14
|
14
|
14
|
14
|
14
|
Power Supply (V)
|
24VDC
|
100 - 240VAC
|
24VDC
|
24VDC
|
100 - 240VAC
|
100 - 240VAC
|
Integrated Inputs
|
8
|
8
|
8
|
8
|
8
|
8
|
Integrated Outputs
|
6
|
6
|
6
|
6
|
6
|
6
|
Output Type
|
Relay
|
Relay
|
Transistor (Sink)
|
Transistor (Source)
|
Transistor (Sink)
|
Transistor (Source)
|
Power Consumption (W)
|
6.5
|
19
|
6.5
|
6.5
|
19
|
19
|
Weight (kg)
|
0.22
|
0.3
|
0.22
|
0.22
|
0.3
|
0.3
|
Dimensions (W x H x D) mm
|
60 x 90 x 49
|
60 x 90 x75
|
60 x 90 x 49
|
60 x 90 x 49
|
60 x 90 x 75
|
60 x 90 x 75
|
FX3S Main Units with 20 I/O
Model Number
|
FX3S-20MR/DS
|
FX3S-20MR/ES
|
FX3S-20MT/DS
|
FX3S-20MT/DSS
|
FX3S-20MT/ES
|
FX3S-20MT/ESS
|
Stocked Item
|
S
|
S
|
-
|
S
|
S
|
S
|
Rating
|
UL • cUL • CE (EMC)
| |||||
Integrated Inputs/Outputs
|
20
|
20
|
20
|
20
|
20
|
20
|
Power Supply (V)
|
24VDC
|
100 - 240VAC
|
24VDC
|
24VDC
|
100 - 240VAC
|
100 - 240VAC
|
Integrated Inputs
|
12
|
12
|
12
|
12
|
12
|
12
|
Integrated Outputs
|
8
|
8
|
8
|
8
|
8
|
8
|
Output Type
|
Relay
|
Relay
|
Transistor (Sink)
|
Transistor (Source)
|
Transistor (Sink)
|
Transistor (Source)
|
Power Consumption (W)
|
7
|
20
|
7
|
7
|
20
|
20
|
Weight (kg)
|
0.3
|
0.4
|
0.3
|
0.3
|
0.4
|
0.4
|
Dimensions (W x H x D) mm
|
75 x 90 x 49
|
75 x 90 x 75
|
75 x 90 x 49
|
75 x 90 x 49
|
75 x 90 x 75
|
75 x 90 x 75
|
FX3S Main Units with 30 I/O
Model Number
|
FX3S-30MR/DS
|
FX3S-30MR/ES
|
FX3S-30MT/DS
|
FX3S-30MT/DSS
|
FX3S-30MT/ES
|
FX3S-30MT/ESS
|
Stocked Item
|
S
|
S
|
-
|
S
|
S
|
S
|
Rating
|
UL • cUL • CE (EMC)
| |||||
Integrated Inputs/Outputs
|
30
|
30
|
30
|
30
|
30
|
30
|
Power Supply (V)
|
24VDC
|
100 - 240VAC
|
24VDC
|
24VDC
|
100 - 240VAC
|
100 - 240VAC
|
Integrated Inputs
|
16
|
16
|
16
|
16
|
16
|
16
|
Integrated Outputs
|
14
|
14
|
14
|
14
|
14
|
14
|
Output Type
|
Relay
|
Relay
|
Transistor (Sink)
|
Transistor (Source)
|
Transistor (Sink)
|
Transistor (Source)
|
Power Consumption (W)
|
8.5
|
21
|
8.5
|
8.5
|
21
|
21
|
Weight (kg)
|
0.35
|
0.45
|
0.35
|
0.35
|
0.45
|
0.45
|
Dimensions (W x H x D) mm
|
100 x 90 x 49
|
100 x 90 x 75
|
100 x 90 x 49
|
100 x 90 x 49
|
100 x 90 x 75
|
100 x 90 x 75
|
FX3S Main Units with 30 I/O and Analog Inputs
Model Number
|
FX3S-30MR/ES-2AD
|
FX3S-30MT/ES-2AD
|
FX3S-30MT/ESS-2AD
|
Stocked Item
|
S
|
S
|
S
|
Rating
|
UL • cUL • CE (EMC)
| ||
Integrated Inputs/Outputs
|
30
|
30
|
30
|
Power Supply (V)
|
100 - 240VAC
|
100 - 240VAC
|
100 - 240VAC
|
Integrated Digital Inputs
|
16
|
16
|
16
|
Integrated Analog Inputs
|
2 (10 bit, 0-10VDC)
|
2 (10 bit, 0-0VDC)
|
2 (10 bit, 0-10VDC)
|
Integrated Outputs
|
14
|
14
|
14
|
Output Type
|
Relay
|
Transistor (Source)
|
Transistor (Sink)
|
Power Consumption (W)
|
21
|
21
|
21
|
Weight (kg)
|
0.45
|
0.45
|
0.45
|
Dimensions (W x H x D) mm
|
100 x 90 x 49
|
100 x 90 x 75
|
100 x 90 x 75
|
Jual Mitsubishi PLC FX1S-30M
Mitsubishi PLC Tipe FX1S-30M
- Mitsubishi FX1S-30MT-DSS
- Mitsubishi FX1S-30MR-DS
- Mitsubishi FX1S-30MR-ES/UL
Spesifikasi Mitsubishi PLC Tipe FX1S-30M
FX1S-30MT-DSS | FX1S-30MR-DS | FX1S-30MR-ES/UL | |
Part Number | FX1S-30MT-DSS | FX1S-30MR-DS | FX1S-30MR-ES/UL |
Series | FX1S | FX1S | FX1S |
Manufacturer | Mitsubishi | Mitsubishi | Mitsubishi |
Our part number | FX1S30MTDSS | FX1S30MRDS | FX1S30MRES/UL |
Inputs amount | 16 | 16 | 16 |
Inputs type | 24 VDC Sink/Source | 24 VDC Sink/Source | 100-240 VAC |
Outputs type | Transistor (source) | Relay | Relay |
Voltage | 12-24 VDC | 24 VDC | 100-240 VAC |
Height (mm) | 90 | 90 | 90 |
Width (mm) | 100 | 100 | 100 |
Depth (mm) | 49 | 49 | 75 |
Weight (kg) | 0.35 | 0.35 | 0.45 |
Information Product Mitsubishi PLC Tipe FX1S-14M
- Available as AC or DC powered
- Available with 10-30 inputs/outputs
- Available with relay or transistor outputs
- High speed inputs for fast counting tasks
- LEDs for indicating input & output status
- Two analogue potentiometers & a run/stop switch
- Integrated RS422 serial interface
- Can be mounted on DIN rail or a flat surface
- Password access protection
- 2,000 step program EEPROM memory
- Incorporated positioning control
- Integrated real time clock
- Two integrated high speed pulse outputs
- Square pulse output on transistor models
- Internal service 24 VDC power supply on AC models
- User friendly programming systems
Jual Mitsubishi PLC FX1S-20M Seri
Mitsubishi PLC Tipe FX1S-20M
- Mitsubishi FX1S-20MT-DSS
- Mitsubishi FX1S-20MR-DS
- Mitsubishi FX1S-20MR-ES
Spesifikasi Mitsubishi PLC Tipe FX1S-20M
FX1S-20MT-DSS | FX1S-20MR-DS | FX1S-20MR-ES | |
Part Number | FX1S-20MT-DSS | FX1S-20MR-DS | FX1S-20MR-ES |
Series | FX1S | FX1S | FX1S |
Manufacturer | Mitsubishi | Mitsubishi | Mitsubishi |
Our part number | FX1S20MTDSS | FX1S20MRDS | FX1S20MRES/UL |
Inputs amount | 12 | 12 | 12 |
Inputs type | 24 VDC Sink/Source | 24 VDC Sink/Source | 100-240 VAC |
Outputs amount | 8 | 8 | 8 |
Outputs type | Transistor (source) | Relay | Relay |
Voltage | 24 VDC | 24 VDC | 100-240 VAC |
Height (mm) | 90 | 90 | 90 |
Width (mm) | 75 | 75 | 75 |
Depth (mm) | 49 | 49 | 75 |
Weight (kg) | 0.3 | 0.3 | 0.4 |
Information Product Mitsubishi PLC Tipe FX1S-20M
- Available as AC or DC powered
- Available with 10-30 inputs/outputs
- Available with relay or transistor outputs
- High speed inputs for fast counting tasks
- LEDs for indicating input & output status
- Two analogue potentiometers & a run/stop switch
- Integrated RS422 serial interface
- Can be mounted on DIN rail or a flat surface
- Password access protection
- 2,000 step program EEPROM memory
- Incorporated positioning control
- Integrated real time clock
- Two integrated high speed pulse outputs
- Square pulse output on transistor models
- Internal service 24 VDC power supply on AC models
- User friendly programming systems
Jual Power Supply Unit CJ-series
CJ1W-PA/PD
Equipped with the RUN output for checking the operation status, as well as the replacement notification function for easy maintenance. Lineup of five models including the AC power supply (25W).
The replacement notification function can prevent an overflow of the system due to the power lifetime. (CJ1W-PA205C only)
Power Supply Unit provides wide variations according to the system scale up to maximum 25 W.
Power Supply Unit provides wide variations according to the power supply (100 to 240 V AC/ 24 V DC) status.
The output contact during operation enables you to check the CPU operation. (CJ1W-PA205R only)
Conforming to the SEMI-F47 Standard. *
*AC input type, 200 V min. input.
Power Supply Unit provides wide variations according to the system scale up to maximum 25 W.
Power Supply Unit provides wide variations according to the power supply (100 to 240 V AC/ 24 V DC) status.
The output contact during operation enables you to check the CPU operation. (CJ1W-PA205R only)
Conforming to the SEMI-F47 Standard. *
*AC input type, 200 V min. input.
Specifications :
Item | Specifications | ||
Model | CJ1W-PA205R | CJ1W-PA205C | CJ1W-PA202 |
Supply voltage | 100 to 240 V AC (wide-range), 50/60 Hz | ||
Operating voltage and frequency ranges | 85 to 264 V AC, 47 to 63 Hz | ||
Power consumption | 100 VA max. | 50 VA max. | |
Inrush current *1 | At 100 to 120 V AC: 15 A/8 ms max. for cold start at room temperature At 200 to 240 V AC: 30 A/8 ms max. for cold start at room temperature | At 100 to 120 V AC: 20 A/8 ms max. for cold start at room temperature At 200 to 240 V AC: 40 A/8 ms max. for cold start at room temperature | |
Output capacity *7 | 5.0 A, 5 V DC (including supply to CPU Unit) | 2.8 A, 5 V DC (including supply to CPU Unit) | |
0.8 A, 24 V DC | 0.4 A, 24 V DC | ||
Total: 25 W max. | Total: 14 W max. | ||
Output terminal (service supply) | Not provided. | ||
RUN output *2 | Contact configuration: SPST-NO Switch capacity: 250 V AC, 2 A (resistive load) 120 V AC, 0.5 A (inductive load), 24 V DC, 2A (resistive load) 24 V DC, 2 A (inductive load) | Not provided. | |
Replacement notification function | Not provided. | With Alarm output (open-collector output) 30 V DC max., 50 mA max. | Not provided. |
Insulation resistance | 20 MΩ min. (at 500 V DC) between AC external and GR terminals *3 | 20 MΩ min. (at 500 V DC) between all external terminals and GR terminal *3, and between all alarm output terminals. 20 MΩ 1 min. (at 250 V DC) between all alarm output terminals and GR terminal *3. | 20 MΩ min. (at 500 V DC) between AC external and GR terminals *3 |
Dielectric strength *4 | 2,300 V AC 50/60 Hz for 1 min between AC external and GR terminals *3 Leakage current: 10 mA max. | 2,300 VAC, 50/60 Hz for 1 min between all external terminals and GR terminal *3 and between all alarm output terminals with a leakage current of 10 mA max. 1,000 V AC, 50/60 Hz for 1 min between all alarm output terminals and GR terminal *3 with a leakage current of 10 mA max. | 2,300 V AC 50/60 Hz for 1 min between AC external and GR terminals *3 Leakage current: 10 mA max. |
1,000 V AC, 50/60 Hz for 1 minute between DC external and GR terminals *3 Leakage current: 10 mA max. | |||
Noise immunity | 2 kV on power supply line (conforming to IEC61000-4-4) | ||
Vibration resistance | Conforms to IEC60068-2-6 5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz Acceleration of 9.8 m/s2 for 100 min in X, Y, and Z directions (10 sweeps of 10 min each = 100 min) | ||
Shock resistance | Conforms to IEC60068-2-27 147 m/s2, 3 times in X, Y, and Z directions (100 m/s2 for Relay Output Units) | ||
Ambient operating temperature | 0 to 55 ° C | ||
Ambient operating humidity | 10% to 90% (with no condensation) | 10% to 90% (with no condensation) *5 | 10% to 90% (with no condensation) |
Atmosphere | Must be free from corrosive gases. | ||
Ambient storage temperature | - 20 to 70 ° C (excluding battery) | - 20 to 75 ° C *5 | - 20 to 75 ° C (excluding battery) |
Grounding | Less than 100 Ω | ||
Enclosure | Mounted in a panel. | ||
Weight | All models are each 5 kg max. | ||
CPU Rack dimensions | 90.7 to 466.7 × 90 × 65 mm (W × H × D) (not including cables) Note: W = a + b + 20 × n + 31 × m + 14.7 a: Power Supply Unit: PA205R and PA205C = 80; PA202 = 45; PD025 = 60; PD022=27 b: CPU Unit: CJ1-H or CJ1 = 62; CJ1M-CPU1[] = 31; CJ1M-CPU2[] = 49 The total width is given by the following: W = 156.7 + n × 20 + m × 31, where n is the number of 32-point I/O Units or I/O Control Units and m is the number of other Units. | ||
Safety measures | Conforms to cULus and EC Directives. |
Item Power Supply Unit | Specifications | |
CJ1W-PD025 | CJ1W-PD022 | |
Supply voltage | 24 VDC | |
Operating voltage and frequency ranges | 19.2 to 28.8 V DC | 21.6 to 26.4 V DC |
Power consumption | 50 W max. | 35 W max. |
Inrush current *1 | At 24 V DC: 30 A/20 ms max. for cold start | |
Output capacity *7 | 5.0 A, 5 V DC (including supply to CPU Unit) | 2.0 A, 5 V DC (including supply to CPU Unit) |
0.8 A, 24 V DC | 0.4 A, 24 V DC | |
Total: 25 W max. | Total: 19.6 W max. | |
Output terminal (service supply) | Not provided. | |
RUN output *2 | Not provided. | |
Replacement notification function | Not provided. | |
Insulation resistance | 20 MΩ min. (at 500 V DC) between DC external and GR terminals *3 | --- *6 |
Dielectric strength *4 | 1,000 V AC, 50/60 Hz for 1 min between DC external and GR terminals *3 Leakage current: 10 mA max. | --- *6 |
Noise immunity | 2 kV on power supply line (conforming to IEC61000-4-4) | |
Vibration resistance | Conforms to IEC60068-2-6 5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz Acceleration of 9.8 m/s2 for 100 min in X, Y, and Z directions (10 sweeps of 10 min each = 100 min) | |
Shock resistance | Conforms to IEC60068-2-27 147 m/s2, 3 times in X, Y, and Z directions (100 m/s2 for Relay Output Units) | |
Ambient operating temperature | 0 to 55 ° C | |
Ambient operating humidity | 10% to 90% (with no condensation) | |
Atmosphere | Must be free from corrosive gases. | |
Ambient storage temperature | - 20 to 75 ° C (excluding battery) | |
Grounding | Less than 100 Ω | |
Enclosure | Mounted in a panel. | |
Weight | All models are each 5 kg max. | |
CPU Rack dimensions | 90.7 to 466.7 × 90 × 65 mm (W × H × D) (not including cables) Note: W = a + b + 20 × n + 31 × m + 14.7 a: Power Supply Unit: PA205R and PA205C = 80; PA202 = 45; PD025 = 60; PD022=27 b: CPU Unit: CJ1-H or CJ1 = 62; CJ1M-CPU1[] = 31; CJ1M-CPU2[] = 49 The total width is given by the following: W = 156.7 + n × 20 + m × 31, where n is the number of 32-point I/O Units or I/O Control Units and m is the number of other Units. | |
Safety measures | Conforms to cULus and EC Directives. |
*1.Disconnect the Power Supply Units LG terminal from the GR terminal when testing insulation and dielectric strength. Testing the insulation and dielectric strength with the LG terminal and the GR terminals connected will damage internal circuits in the CPU Unit.
*2.Supported only when mounted to CPU Rack.
*3.The inrush current is given for a cold start at room temperature. The inrush control circuit uses a thermistor element with a low-temperature current control characteristic. If the ambient temperature is high or the PLC is hot-started, the thermistor will not be sufficiently cool, and the inrush currents given in the table may be exceeded by up to twice the given values. When selecting fuses or breakers for external circuits, allow sufficient margin in shut-off performance.
*4.Maintain an ambient storage temperature of −25 to 30°C and relative humidity of 25% to 70% when storing the Unit for longer than 3 months to keep the replacement notification function in optimum working condition.
*5.Change the applied voltage gradually using the adjuster on the Tester. If the full dielectric strength voltage is applied or turned OFF using the switch on the Tester, the generated impulse voltage may damage the Power Supply Unit.
*6.CJ1W-PD022 is not insulated between the primary DC power and secondary DC power.
*7.Internal components in the Power Supply Unit will deteriorate or be damaged if the Power Supply Unit is used for an extended period of time exceeding the power supply output capacity or if the outputs are shorted.
Checking Current Consumption and Power Consumption
After selecting a Power Supply Unit based on considerations such as the power supply voltage, calculate the current and power requirements for each Rack.
Condition 1: Current Requirements
There are two voltage groups for internal power consumption: 5 V and 24 V.
Current consumption at 5 V (internal logic power supply)
Current consumption at 24 V (relay driving power supply)
Condition 2: Power Requirements
For each Rack, the upper limits are determined for the current and power that can be provided to the mounted Units. Design the system so that the total current consumption for all the mounted Units does not exceed the maximum total power or the maximum current supplied for the voltage groups shown in the following tables.
The maximum current and total power supplied for CPU Racks and Expansion Racks according to the Power Supply Unit model are shown below.
Note:
1.For CPU Racks, include the CPU Unit current and power consumption in the calculations. When expanding, also include the current and power consumption of the I/O Control Unit in the calculations.
2.For Expansion Racks, include the I/O Interface Unit current and power consumption in the calculations.
*2.Supported only when mounted to CPU Rack.
*3.The inrush current is given for a cold start at room temperature. The inrush control circuit uses a thermistor element with a low-temperature current control characteristic. If the ambient temperature is high or the PLC is hot-started, the thermistor will not be sufficiently cool, and the inrush currents given in the table may be exceeded by up to twice the given values. When selecting fuses or breakers for external circuits, allow sufficient margin in shut-off performance.
*4.Maintain an ambient storage temperature of −25 to 30°C and relative humidity of 25% to 70% when storing the Unit for longer than 3 months to keep the replacement notification function in optimum working condition.
*5.Change the applied voltage gradually using the adjuster on the Tester. If the full dielectric strength voltage is applied or turned OFF using the switch on the Tester, the generated impulse voltage may damage the Power Supply Unit.
*6.CJ1W-PD022 is not insulated between the primary DC power and secondary DC power.
*7.Internal components in the Power Supply Unit will deteriorate or be damaged if the Power Supply Unit is used for an extended period of time exceeding the power supply output capacity or if the outputs are shorted.
Checking Current Consumption and Power Consumption
After selecting a Power Supply Unit based on considerations such as the power supply voltage, calculate the current and power requirements for each Rack.
Condition 1: Current Requirements
There are two voltage groups for internal power consumption: 5 V and 24 V.
Current consumption at 5 V (internal logic power supply)
Current consumption at 24 V (relay driving power supply)
Condition 2: Power Requirements
For each Rack, the upper limits are determined for the current and power that can be provided to the mounted Units. Design the system so that the total current consumption for all the mounted Units does not exceed the maximum total power or the maximum current supplied for the voltage groups shown in the following tables.
The maximum current and total power supplied for CPU Racks and Expansion Racks according to the Power Supply Unit model are shown below.
Note:
1.For CPU Racks, include the CPU Unit current and power consumption in the calculations. When expanding, also include the current and power consumption of the I/O Control Unit in the calculations.
2.For Expansion Racks, include the I/O Interface Unit current and power consumption in the calculations.
Power Supply Units | Max. current supplied | Max. total power supplied | |
5 V | 24 V (relay driving current) | ||
CJ1W-PA205R | 5.0 A | 0.8 A | 25 W |
CJ1W-PA205C | 5.0 A | 0.8 A | 25 W |
CJ1W-PA202 | 2.8 A | 0.4 A | 14 W |
CJ1W-PD025 | 5.0 A | 0.8 A | 25 W |
CJ1W-PD022 | 2.0 A | 0.4 A | 19.6 W |
Conditions 1 and 2 below must be satisfied.
Condition 1: Maximum Current
(1)Total Unit current consumption at 5 V ≤ (A) value
(2)Total Unit current consumption at 24 V ≤ (B) value
Condition 2: Maximum Power
(1) × 5 V + (2) × 24 V ≤ (C) value
Example: Calculating Total Current and Power Consumption
Example: When the Following Units are Mounted to a CJ-series CPU Rack Using a CJ1W-PA202 Power Supply Unit
Condition 1: Maximum Current
(1)Total Unit current consumption at 5 V ≤ (A) value
(2)Total Unit current consumption at 24 V ≤ (B) value
Condition 2: Maximum Power
(1) × 5 V + (2) × 24 V ≤ (C) value
Example: Calculating Total Current and Power Consumption
Example: When the Following Units are Mounted to a CJ-series CPU Rack Using a CJ1W-PA202 Power Supply Unit
Unit type | Model | Quantity | Voltage group | |
5 V | 24 V | |||
CPU Unit | CJ1G-CPU45H | 1 | 0.910 A | --- |
I/O Control Unit | CJ1W-IC101 | 1 | 0.020 A | --- |
Basic I/O Units (Input Units) | CJ1W-ID211 | 2 | 0.080 A | --- |
CJ1W-ID231 | 2 | 0.090 A | --- | |
Basic I/O Units (Output Units) | CJ1W-OC201 | 2 | 0.090 A | 0.048 A |
Special I/O Unit | CJ1W-DA041 | 1 | 0.120 A | --- |
CPU Bus Unit | CJ1W-CLK23 | 1 | 0.350 A | --- |
Current consumption | Total | 0.910 + 0.020 + 0.080 × 2 + 0.090 × 2 + 0.090 × 2 + 0.120 + 0.350 | 0.048 A × 2 | |
Result | 1.92 A ( ≤ 2.8 A) | 0.096 A ( ≤ 0.4 A) | ||
Power consumption | Total | 1.92 × 5 V = 9.60 W | 0.096 A × 24 V = 2.304 W | |
Result | 9.60 + 2.304 11.904 W ( ≤ 14 W) |
Jual Mitsubishi Compact PLC Melsec FX1N Seri
Mitsubishi Compact PLC Melsec FX1N ini tersedia dalam beberapa tipe, yaitu :
- Tipe FX1N-14
- Tipe FX1N-24
- Tipe FX1N-40
- Tipe FX1N-60
Mitsubishi Compact PLC Melsec FX1N menggabungkan manfaat dari kontroler kompak dengan kemampuan ekspansi yang fleksibel dari sistem kontrol modular. Hal ini dapat diperluas hingga 128 input dan output dan dengan berbagai komprehensif modul fungsi khusus. Mitsubishi Compact PLC Melsec FX1N ini juga dilengkapi dengan pengontrol posisi kuat terintegrasi.
Kemampuan komunikasi dan kemampuan data link membuatnya ideal untuk aplikasi di mana ukuran controller hardware, fitur komunikasi, fungsi khusus dan kecepatan pemrosesan semua penting.
Kemampuan komunikasi dan kemampuan data link membuatnya ideal untuk aplikasi di mana ukuran controller hardware, fitur komunikasi, fungsi khusus dan kecepatan pemrosesan semua penting.
Mitsubishi Compact PLC Melsec FX1N highlights:
- 14 to 128 inputs and outputs
- High processing speed ( 0.55µ s per log. instruction)
- Ample program storage capacity ( 8, 000 steps) and device ranges
- Integrated positioning controller
- Comprehensive range of special function and expansion modules for individual requirements
- Integrated PID controller
- Support for connection to open networks
- Integrated real-time clock
- User-friendly programming with MS Windows-based programming software package or hand-held programming unit
- Analog signal processing with optional expansion adapters
Spesifikasi Mitsubishi Compact PLC Melsec FX1N :
Type | FX1N-14 | FX1N-24 | FX1N-40 | FX1N-60 |
---|---|---|---|---|
Power supply | 100-240 V AC/ 12-24 V DC | |||
No. of inputs | 8 | 14 | 24 | 36 |
No. of outputs | 6 | 10 | 16 | 24 |
Digital outputs | Relay / Transistor | |||
Program cycle period per logical instruction | 0.55 -1 µs | |||
User memory | 8.000 steps EEPROM (internal), EEPROM/ EPROM cassettes (optional) | |||
Dimensions in mm (WxHxD) | 90 x 90 x 75 | 90 x 90 x 75 | 175 x 90 x 75 | 185 x 90 x 75 |
Jual Mitsubishi Compact PLC Melsec FX1S Seri
Mitsubishi Compact PLC Melsec FX1S ini tersedia dalam beberapa tipe, yaitu :
- Tipe FX1S-10M
- Mitsubishi FX1S-10MT-DSS
- Mitsubishi FX1S-10MR-DS
- Mitsubishi FX1S-10MR-ES/UL
- Tipe FX1S-14M
- Mitsubishi FX1S-14MR-DS
- Mitsubishi FX1S-14MT-DSS
- Mitsubishi FX1S-14MR-ES/UL
- Tipe FX1S-20M
- Mitsubishi FX1S-20MT-DSS
- Mitsubishi FX1S-20MR-DS
- Mitsubishi FX1S-20MR-ES/UL
- Tipe FX1S-30M
- Mitsubishi FX1S-30MT-DSS
- Mitsubishi FX1S-30MR-DS
- Mitsubishi FX1S-30MR-ES/UL
Controller dari seri Mitsubishi Compact PLC Melsec FX1S series memberikan fungsi yang luar biasa sampai dengan I/O 30 dalam paket yang sangat kompak. Mitsubishi Compact PLC Melsec FX1S series sangat ideal untuk aplikasi sulit untuk akses instalasi dan sistem di mana pelayanan yang normal tidak mungkin. real-time terintegrasi dan bebas perawatan EEPROM dengan kapasitas hingga 2.000 langkah program yang membuat FX1S menyediakan sistem otonom dan pelayanan yang sangat mudah.
Mitsubishi Compact PLC Melsec FX1S series highlights:
- 10 to 30 inputs and outputs
- High processing speed ( 0.55? s per log. instruction)
- Ample program storage space and large device ranges Integrated positioning controller
- Serial communications options ( RS-232, RD-422, RS-485)
- Analog signal processing with optional expansion adapters
- Integrated real-time clock
- User-friendly programming with MS Windows-based programming software package or hand-held programming unit
- Expandable with adapters or display modules
Information Product
- Available as AC or DC powered
- Available with 10-30 inputs/outputs
- Available with relay or transistor outputs
- High speed inputs for fast counting tasks
- LEDs for indicating input & output status
- Two analogue potentiometers & a run/stop switch
- Integrated RS422 serial interface
- Can be mounted on DIN rail or a flat surface
- Password access protection
- 2,000 step program EEPROM memory
- Incorporated positioning control
- Integrated real time clock
- Two integrated high speed pulse outputs
- Square pulse output on transistor models
- Internal service 24 VDC power supply on AC models
- User friendly programming systems
Spesifikasi Mitsubishi Compact PLC Melsec FX1S :
Type | FX1S-10M | FX1S-14M | FX1S-20M | FX1S-30M |
---|---|---|---|---|
Power supply | 100-240V AC / 24V DC | |||
No. of inputs | 6 | 8 | 12 | 16 |
No. of outputs | 4 | 6 | 8 | 14 |
Digital outputs | Relay / Transistor | |||
Program cycle period per logical instruction | 0.55 - 0.7 µs | |||
User memory | 2000 steps EEPROM (internal) | |||
Dimensions in mm (WxHxD) | 60x90x75 | 60x90x75 | 75x90x75 | 100x90x75 |
Langganan: