Kontak Kami

KONTAK KAMI : Telpon : 02126071413 Hp/WhatsApp : 081212269831 Perwakilan Jakarta : Gedung LTC Glodok Lantai 1 Blok C30 No.31 Jl.Hayam Wuruk No.127 Jakarta , Indonesia

Rabu, 14 Februari 2018

INVERTER DELTA VFD-EL: VFD002EL11A,VFD002EL21A,VFD002EL23A,VFD004EL11A,VFD004EL21A,VFD004EL23A,VFD004EL43A,VFD007EL21A,VFD007EL23A,VFD007EL43A,VFD015EL23A,VFD015EL43A ,VFD007EL11A,VFD015EL21A,VFD022EL21A,VFD022EL23A,VFD037EL23A,VFD037EL43A


Features


  • Standard MODBUS Protocol Standard MODBUS Protocol via RS-485
  • Built-in EMI Filter (230V 1-Phase and 360V 3-Phase) The built-in EMI filter reduces electromagnetic interferences and complies with EN61800-3 standard.
  • Compact Design Space saving and easy DIN rail mounting with optional DIN rail adapter (Built in Frame B)
  • Optional Feildbus Modules Provide connection to variety of networks, including PROFIBUS, DeviceNet, Lon Works and CANopen.
  • RFI-Switch for IT Mains Removable "Y" capacitor to use with IT mains supplies.
  • Easy DC BUS Sharing Multiple VFD-EL can be connected in parallel to share the regenerative braking energy In this way, over-voltage is prevented and the DC-bus voltage stabilized. This function is not for 115V models
  • Complete Protection Function High precision current detection, full overload protection (oL,oL1 and oL2), over-voltage/over-current stall prevention , short-circuit protection, reset after fault, speed search function and motor overheat protection by PTC.
  • Power range 
1-Phase 115V series: 0.2~0.75kW (0.25~1hp)   1-Phase 230V series: 0.2~2.2kW (0.25~3hp)   3-Phase 230V series: 0.2~3.7kW (0.25~5hp)    3-Phase 460V series: 0.4~3.7kW ( 0.50~5hp) 

  • Side-by-side installation (40C) High-efficiency cooling and flexible space

  • Easy Maintenance Removable cooling fan for easy maintenance

Applications

Conveyor Belts
  1. Multi-step speed Application: Provides multi-step speed settings to meet the needs of conveyor belt.
  2. Side-by-side installation to save space
  3. DC-bus sharing: connect multiple drives in parallel to share the regenerative energy and prevent over-voltage
Winders
With auto acceleration/deceleration function, it can have a rapid start/stop to increase productivity and speed
Constant Pressure Control of Water Pumps

  1. Built-in smart PID controller to save the cost of specific external PID meter.
  2. Built-in auto detection of water suspension and auto power-on save the cost of external PLC controller and relay.
  3. A wide range of input voltages, including 1-phase 110V/230V and 3-Phase 230V/460V, for various pump applications and different countries.


 Application Fields
Conveyor and Transportation Machinery
  • Conveyor belt
  • Automatic doors
  • Roller door
  • Small elevator
  • Escalator
  • Parking device
  • X-Y axis of traveling crane
Food Processing 
  • Dumpling maker
  • Food stirrer
  • Noodle maker
Machine Tool/Metal Processing Machinery
  • Grinder 
  • Drill
  • Small lathe
  • Milling machines
  • Injection molding (clamp)
Wood Working Machinery
  • 4 side planer
  • Wood carver
  • Wood working machine
  • Simple cutting machine for wood working
  • Spraying machine
Fan/Pump Equipment
  • Building air conditioner 
  • Waste water processing system
  • Constant pressure water treatment system
  • Water treatment pump
  • Agricultural pump
  • Temperature control of middle/large oven
  • Air compressor
  • Heat exchange fans
  • Building water dispenser system
  • Dryer's windmill
Paper/Textile Machine
  • Round weaver
  • Cross weaver
  • Ribbon weaver
  • Printing press
  • Industrial sewing machines
Others
  • Ironing machine
  • Pulverizer
  • Treadmil
  • Feeder
  • Industrial washing machine
  • Car washing machine
  • Packing machine
  • Centrifuge
  • Liquid mixer
Model
VFD002EL11A
VFD002EL21A
VFD002EL23A
VFD004EL11A
VFD004EL21A
VFD004EL23A
VFD004EL43A
VFD007EL21A
VFD007EL23A
VFD007EL43A
VFD015EL23A
VFD015EL43A

VFD007EL11A
VFD015EL21A
VFD022EL21A
VFD022EL23A
VFD037EL23A
VFD037EL43A

Fieldbus Modules


DeviceNet
CME-DN01


Profibus
CME-PD01

Lon Works
CME-COP01





Accessories

Zero phase reactor 
RF220X00A


Keypad for communication
VFD-PU06

Grounding plate
MKE-EP


Break resistor



Brake Unit
BUE-20015
BUE20037

BUE-40015
BUE-40037









Selasa, 13 Februari 2018

Mitsubishi Inverter FR-D700 Series

Features

  • Improved reliability and easy maintenance
Spring clamp terminals provide high reliability and easy wiring. Shutoff circuit (hardware)  securely provides emergency output shutoffs. The inverter with the safety stop function can comply with the safety standard without incurring too much cost. Parameter writing/reading can be restricted with a 4-digit password. The lives of the cooling fan and capacitor have been extended. Using the self-diagnosis function, the part life warning can be output and the degree of deterioration can be monitored to prevent malfunction.

  • Pursuing the best performance
The General-purpose magnetic flux vector control and the auto tuning function enable operation in applications that require large starting torque. (150% 1Hz, 200% 3Hz (3.7K or lower with the slip compensation))

  • Easy-to-use (Pursing the easy operation)
The non-slip, adaptable scroll speed setting dial allows for quick jumps or precise increments based on turning speed. Setting can be made easily from a personal computer with FR Configurator. An enclosure surface operation panel, which can be attached on an enclosure surface, is available as an option. Operation panel for the FR-E500 series inverters can be also connected . The inverters with 0.4K or higher capacity have built-in regenerative brake transistors, and their usage can be extended to a lift application.

  • Environmentally friendly 
Filter options reduce the electromagnetic noise generated at the inverter and enables the compliance with the harmonic suppression guidelines of japan.

Model

FR-D740[]-0.4K 

Specifications
Control method : Soft-PWM control, high carrier frequency PWM control (V/F control, General-purpose magnetic flux vector control, Optimum excitation control can be selected)
Starting torque : 150% 1Hz , 200% 3 Hz (3.7K or lower) with General-purpose magnetic flux vector control and slip compensation. 
Output frequency range: 0.2 to 400Hz
Regenerative /deceleration time setting : 0.1K/0.2K....150%, 0.4/0.75K ...100%, 1.5K...50%, 2.2K or higher ...20%
Accelerations/deceleration time setting : 0 to 3600s (up to two types of accelerations can be set individually)
Multi-speed  : 15 speed
Speed command : 0 to 5VDC, 0 to 10VDC, 4 to 20mA, digital input with setting dial, digital setting with operation panel or parameter unit.
Alarm output  : 1 changeover contact output (230VAC 0.3A 30VDC 0.3A) open collector output
Output signal  : One type of open  collector and one type of contact output ( 1 changeover contact) can be selected from inverter running, up to frequency, frequency detection, output current detection, operation ready, overload warning, fault output, and alarm, etc.
Monitor function : One monitored item can be selected from output frequency, motor  current (steady or peak value), output voltage, frequency setting value, converter output voltage, regenerative brake duty, and output power, etc. Pulse train output (1440 pulses/s 1mA) 
Restart after instantaneous power failure : Available (reduced voltage (frequency search selectable))


Communication function  : RS-485 supported (Modbus-RTU) as standard.

Mitsubishi Inverter FR-F700PJ Series : FR-F740PJ-3.7K

FR-F700PJ Series
Features

  • Suitable for both the general-purpose motor and the IPM motor
The series can drive both a general-purpose motor and IPM motor. Switching between the two motor controls is simple--just a single parameter setting. Initially, a general purpose motor could be used, then upgraded to an IPM motor without switching this inverter, leading to lower cost of equipment.

  • Environmentally Friendly 
Power factor improving DC reactor, common mode choke (line noise filter), capacitive filter (radio noise filter) are all essential for air conditioning applications, and all of these are included in the conditioning applications and all of these are included in the Filter pack. The inverter with Filter pack (FR-F7[]0PJ-[]F) is also available The wiring with different options is no longer required.
Less wiring and smaller space is required when Filter pack also enables compliance with the harmonic suppression guideline, the architectural standard specifications (electrical installation), and the architectural standard specifications (machinery installation) (2010 revisions) in japan 

  • Easy-to-use
The following functions provide the ideal operation for fans and pumps (PID control, Optimum excitation control, regeneration avoidance, and automatic restart after instantaneous power failure)

  • Improved reliability and easy maintenance 
Spring clamp terminals provide high reliability and easy wiring. The lives of the cooling fan and capacitor have been extended. Using the self-diagnosis function, the component life warning can be monitored to prevent malfunction.

Model

FR-F740PJ-3.7K 

Specifications
Control method  : Soft-PWM control, high carrier frequency PWM control (V/F control, General-purpose magnetic flux vector control, Optimum excitation control, and IPM motor control can be selected)
Starting torque General-purpose motor control  : 120% (at 1Hz) with General-purpose magnetic flux vector control and slip compensation.
Starting torque IPM motor control  :  50%
Output frequency range General-purpose  : 0.2 to 400Hz
Output frequency range IPM motor control  : MM-EF : 0 to 135Hz
Regenerative braking torque General-purpose motor control  : 15%  * 1
Regenerative braking torque IPM motor control  : 5 % (10% for 1.5kW or lower)*1
Acceleration /deceleration time setting  : 0.1 to 3600s (up to two types of accelerations and decelerations can be set individually)
Multi-speed  : 15 speed
Speed command : 0 to 5VDC, 0 to 10VDC, 4 to 20mA, digital input with setting dial, digital setting with operation panel or parameter unit.
Alarm output  : 1 changeover contact output (230VAC 0.3A 30VDC 0.3A) open collector output
Output signal  : One type of open  collector and one type of contact output ( 1 changeover contact) can be selected from inverter running, up to frequency, frequency detection, output current detection, operation ready, overload warning, fault output, and alarm, etc.
Monitor function : One monitored item can be selected from output frequency, motor  current (steady or peak value), output voltage, frequency setting value, converter output voltage, regenerative brake duty, and output power, etc. Pulse train output (1440 pulses/s 1mA) 
Restart after instantaneous power failure : Available (reduced voltage (frequency search selectable))
Communication function  : RS-485 supported (Modbus-RTU) as standard.


Mitsubishi Inverter FR-E700 Series:

Features

  • Pursuing the best performance--top level of driving performance in a compact body.
Advanced magnetic flux vector control enables accurate start-ups for general-purpose industrial machines (200% 0.5Hz (3.7K or lower)
Improved short-time permissible overload (200% for 3s) provides powerful and consistent driving . Torque limit and current limit functions are available

  • Easy-to-use (Outstanding operability and diverse expandability) 
The non-slip , adaptable scroll speed setting dial allows for quick jumps or precise increments based on turning speed. The operation mode can be selected  in simple steps. This Series has USB which enables easy setting from a personal computer with FR Configuration. Plug-in options are available to add digital inputs/analog outputs and to support different communication networks. For the customers who need more than the standard terminals, the option blocks, such as the 2-port RS-485 terminal block , are available. The inverters with 0.4K or higher capacity have plug-in regenerative brake transistors, which enable use for lift applications. An enclosure surface and is available as an option. The operation panel of the FR-E500 series can be also connected.

  • Compact and space-saving
The mounting dimensions are the same as the conventional FR-E500 model to keep backwards compatibility. Space can be saved with the side-by-side installation. 

  • Improved reliability and easy maintenance 
Spring clamp terminals provide high reliability and easy wiring. (FR-E700-SC/NF/NC) . Shutoff circuit (hardware) securely provides emergency output shutoffs. The inverter with the safety standards without  incurring too  much cost. (FR-E700-SC/NF/NC).  The lives of the cooling fan and capacitor have been extended. Using the self-diagnosis function, the part life warning can be output and the degree of deterioration can be monitored to prevent malfunction. The removable control circuit terminal block simplifies replacement work.

  •  Environmentally friendly




Filter options reduce the electromagnetic noise generated at the inverter and enables compliance with the harmonic suppression guidelines of japan.
Model 

FR-E720[]-3.7K [] 

Specifications
Control method : Soft-PWM control, high carrier frequency PWM control (V/F control, General-purpose magnetic flux vector control, Advanced magnetic flux vector control or Optimum excitation control can be selected)
Starting torque: 200% 0.5Hz (3.7K or lower ) 150% 0.5Hz (5.5K or higher) with Advanced magnetic flux vector control 
Output frequency range:  0.2 to 400Hz
Regenerative braking torque*1  : 0.1K/0.2K....150%, 0.4K/0.75K...100%, 1.5K...50%, 2.2K or higher ....20%
Acceleration/deceleration time setting : 0 to 360s (up to two types of accelerations can be set individually)
Multi-Speed : 15 speeds
Speed command*2  : 0 to 5VDC, 0 to 10VDC, 4 to 20mA, digital setting with setting dial, 0+10VDC (when using optional analog terminal block), digital setting with operation panel or parameter unit, pulse input (when using optional pulse train terminal block).
Safety Stop*3 :  Output shutoff S1 and S2
Alarm Output*4 : 1 changeover contact (230VAC 0.3A , 30VDC 0.3A), open collector output
Output signal*4 : Two types of open collector outputs and one type of contact output (1 changeover contact) can be selected from inverter running, up to frequency , frequency detection, output current detection, operation ready, overload warning , fault output, and alarm , etc.
Restart instantaneous power failure : Available (reduced voltage method(frequency search selectable)
Removable terminal bock : Use for control circuit terminals
Communication function : RS-485 supported (Modbus-RTU) as standard . CC-Link , PROFIBUS-DP, LonWorks optional available , FL remote communication and CC-Link communication models also available.


Mitsubishi Inverter FR-F700P Series : FR-F720P-3.7K

FR-F700P
Features Series

  • Great CO2 emission reduction with energy-saving drive.         
Optimum excitation control continuously adjusts the highest motor efficiency leading to substantial energy savings. This Series can drive both a general-purpose motor and an IPM motor. Switching between the two motor controls is simple-just a single parameter

  • Easy-to-use
The following functions provide the ideal operation for fans and pumps: variable torque acceleration/deceleration patterns, PID control, commercial power supply switching, adjustable 5 points V/F, continuous avoidance function, etc.

  • Environmentally friendly
The newly developed built-in EMC filter reduces electromagnetic noise generated from the inverter.

  • Improved reliability and easy maintenance
The lives of the cooling fan and capacitor have been extended. Using the self-diagnosis function, the part live warning can be output and the degree of deterioration can be monitored to prevent malfunction . The removable control terminal block and the cooling fan cassette make it easy to replace.
Model

FR-F720P-3.7K 


Specifications
Control Method : Soft-PWM control, high carrier frequency PWM control (V/F control and Optimum excitation control, Simple magnetic flux vector control, and IPM motor control can be selected)
Starting torque  General motor control  : 120% 3Hz, with Simple magnetic flux vector control and slip compensation. 
Starting torque IPM motor control : 50%
Output frequency range General-purpose motor control : 0.5 to 400Hz
Output frequency range IPM motor control : MM-EF :  0 to 135Hz (30K or lower) / 0 to 160Hz (90K or higher)  MM-EFS*1 : 0 to 112.5Hz (15K or lower) / 0 TO 150Hz (18K or higher)
Regenerative braking torque (Maximum value/permissible duty) General-purpose motor control : 0.75K to 55K ....15% continuous, 75K or higher.....10% continuos .
Regenerative braking torque (Maximum value/permissible duty) IPM motor control : Approximately 5%  (1.5 or lower....Approximately 10%)
Acceleration/deceleration time setting  : 0 to 3600s (up to two types of accelerations and decelerations can be set individually)
Multi-speed : 15 Speeds
Speed command : 0 to 5VDC . 0 to 10VDC , 0 to+5VDC , 0 to 10+VDC, 4 to 20mA, digital set with operation panel or parameter unit, 4-digit BCD or 16-bit binary (when using optional FR-A7AX)
Alarm output    : 1 changeover contact (230VAC, 0.3A, 30VDC, 0.3A), open collector output, alarm code (4-bit) output 
Output Signal : Five types of open collector output and two types of contacts outputs (changeover contact) can be selected from inverter running, up to frequency, instantaneous power failure (under voltage), frequency detection, operation ready, overload ready, overload warning, error output and alarm, etc.
Monitor function : One monitored item can be selected from output frequency, motor current (steady or peak value), output voltage, operation speed, converter output voltage, input power, output power and load meter, etc.
Restart after instantaneous power failure : Available (reduced voltage method (frequency search selectable))
Removable  terminal block : Used for control circuit terminals
Communication function  : RS-485 supported (Modbus-RTU) as standard, CC-Link , PROFIBUS-DP , DeviceNet, LonWorks, and FL remote options removable.





Mitsubishi Inverter Family FR-A700 Series

Mitsubishi FR-A700 Series





Features

  • Pursuing the best performance 
High-accuracy, high-response speed control using vector control is possible with a general-purpose motor without encoder. (200% 0.3Hz (3.7K or lower), with real sensor less vector control). Torque control and torque limit under speed control is possible. Full-scale vector control is possible by using this inverter with a motor with encoder. (when using optional FR-A7AP or A7AL) in addition to zero-speed control and servo lock, torque control and position control are available with this general-purpose inverter. The speed command response is improved. (Speed response 300rad/s, speed control range 1:1500 (with model speed control).  The torque fluctuation caused by changes in the motor temperature is reduced. (with adaptive magnetic flux observer having +5% repeated torque accuracy). The speed control again and position loop again do not need to be adjusted. (when simple again tuning is set.)

  • Improved reliability and easy maintenance 

The lives of the cooling fan and capacitor have been extended. Using the self-diagnous function, the part warning can be output and the degree of deterioration can be monitored prevent malfunction. The removable control terminal block and the cooling fan cassette make it easy to replace.  

  • Environmentally friendly  

 The newly developed analyzer function of the FR Configurator vibrates the motor to analyze the resonance frequency of machine. The filter function is available to avoid machine resonances. Encoder expandability the power voltage and input circuit can be selected according to the encoder.

INVERTER 700 Series : FR-A720-0.4K,FR-A720-0.75K,FR-A720-1.5K,FR-A720-2.2K,FR-A720-3.7K,FR-A720-5.5K,FR-A720-7.5K,FR-A720-11K,FR-A720-15K,FR-A720-18.5K,FR-A720-22K,FR-A720-30K,FR-A720-37K,FR-A720-45K,FR-A720-55K,FR-A720-75K,FR-A720-90K



Superior driving performance backed by the highest quality!
Main features of the 700 series

Environmentally friendly


  • The newly developed EMC filter reduces electromagnetic noise generated by the inverter. (Embedded in the FR-A700 and F700P series inverters.)
  • AC and DC reactors can be connected to suppress the harmonic current to the power supply and to improve the power factor.
  • The inverters are compliant with the restriction of hazardous substances (RoHS) directive of EU  and friendly to people and to the environment.

Drive Performance 

  • The inverters provide powerful and consistent driving.

Long-life and easy maintenance

  • Long-life cooling fan *1 and long-life capacitor 1*2 are incorporated (design life: 10 years) *1: Surrounding air temperature: 40C on yearly average (free from corrosive gas,flammable gas,oil mist,dust and dirt). The design life is a calculated value and is not a guaranteed product life       *2 : Output current: 80% of the rated inverter current.
  • Degradation degrees of the main circuit capacitor, control circuit capacitor, and inrush current limit diagnoses the degradation degree and outputs a warning, allowing trouble to the prevented.
  • The removable control circuit terminal block simplifies renewal work. (FR-A700, F700P, E700 series)
  • Cooling fan replacement is performed in simple steps. Maintenance of the inverters is easy

Easy -to-use

  • An operation panel is mounted as standard on all models.
  • The Mitsubishi's setting dial is used.
Capacity table
Mitsubishi FR-A720-[]K :
FR-A720-0.4K
FR-A720-0.75K
FR-A720-1.5K
FR-A720-2.2K
FR-A720-3.7K
FR-A720-5.5K
FR-A720-7.5K
FR-A720-11K
FR-A720-15K
FR-A720-18.5K
FR-A720-22K
FR-A720-30K
FR-A720-37K
FR-A720-45K
FR-A720-55K
FR-A720-75K
FR-A720-90K

Mitsubishi FR-A740-[]K : 
FR-A740-0.4K
FR-A740-0.75K
FR-A740-1.5K
FR-A740-2.2K
FR-A740-3.7K
FR-A740-5.5K
FR-A740-7.5K
FR-A740-11K
FR-A740-15K
FR-A740-18.5K
FR-A740-22K
FR-A740-30K
FR-A740-37K
FR-A740-45K
FR-A740-55K
FR-A740-75K
FR-A740-90K
FR-A740-110K
FR-A740-132K
FR-A740-160K
FR-A740-185K
FR-A740-220K
FR-A740-250K
FR-A740-280K
FR-A740-315K
FR-A740-355K
FR-A740-400K
FR-A740-450K
FR-A740-500K

Mitsubishi FR-F20P-[]K  :
FR-F20P-0.75K
FR-F20P-1.5K
FR-F20P-2.2K
FR-F20P-3.7K
FR-F20P-5.5K
FR-F20P-7.5K
FR-F20P-11K
FR-F20P-15K
FR-F20P-18.5K
FR-F20P-22K
FR-F20P-30K
FR-F20P-37K
FR-F20P-45K
FR-F20P-55K
FR-F20P-75K
FR-F20P-90K
FR-F20P-110K

Mitsubishi FR-F740-[]K
FR-F740-0.75K
FR-F740-1.5K
FR-F740-2.2K
FR-F740-3.7K
FR-F740-5.5K
FR-F740-7.5K
FR-F740-11K
FR-F740-15K
FR-F740-18.5K
FR-F740-22K
FR-F740-30K
FR-F740-37K
FR-F740-45K
FR-F740-55K
FR-F740-75K
FR-F740-90K
FR-F740-110K
FR-F740-132K
FR-F740-160K
FR-F740-185K
FR-F740-220K
FR-F740-250K
FR-F740-280K
FR-F740-315K
FR-F740-355K
FR-F740-400K
FR-F740-450K
FR-F740-500K
FR-F740-560K

Mitsubishi FR-E720-[]K *1 *2 *3  :
FR-E720-0.1K
FR-E720-0.2K
FR-E720-0.4K
FR-E720-0.75K
FR-E720-1.5K
FR-E720-2.2K
FR-E720-3.7K
FR-E720-5.5K
FR-E720-7.5K
FR-E720-11K
FR-E720-15K

Mitsubishi FR-E740-[]K *1 *2 *3 :
FR-E740-0.4K
FR-E740-0.75K
FR-E740-1.5K
FR-E740-2.2K
FR-E740-3.7K
FR-E740-5.5K
FR-E740-7.5K
FR-E740-11K
FR-E740-15K

Mitsubishi FR-E720S-[]K *1  :
FR-E720S-0.1K
FR-E720S-0.2K
FR-E720S-0.4K
FR-E720S-0.75K
FR-E720S-2.2K

Mitsubishi FR-E710W-[]K  : 
FR-E710W-0.1K
FR-E710W-0.2K
FR-E710W-0.4K
FR-E710W-0.75K

Mitsubishi FR-F720PJ-[]K(F)*4   :
FR-F720PJ-0.4K
FR-F720PJ-0.75K
FR-F720PJ-1.5K
FR-F720PJ-2.2K
FR-F720PJ-3.7K
FR-F720PJ-5.5K
FR-F720PJ-7.5K
FR-F720PJ-11K
FR-F720PJ-15K

Mitsubishi FR-F740PJ-[]K(F)*4  :
FR-F740PJ-0.4K
FR-F740PJ-0.75K
FR-F740PJ-1.5K
FR-F740PJ-2.2K
FR-F740PJ-3.7K
FR-F740PJ-5.5K
FR-F740PJ-7.5K
FR-F740PJ-11K
FR-F740PJ-15K

Mitsubishi FR-D720-[]K  :
FR-D720-0.1K
FR-D720-0.2K
FR-D720-0.4K
FR-D720-0.75K
FR-D720-1.5K
FR-D720-2.2K
FR-D720-3.7K
FR-D720-5.5K
FR-D720-7.5K
FR-D720-11K
FR-D720-15K

Mitsubishi FR-D740-[]K  : 
FR-D740-0.4K
FR-D740-0.75K
FR-D740-1.5K
FR-D740-2.2K
FR-D740-3.7K
FR-D740-5.5K
FR-D740-7.5K
FR-D740-11K
FR-D740-15K

Mitsubishi FR-D720S-[]K  :
FR-D720S-0.1K
FR-D720S-0.2K
FR-D720S-0.4K
FR-D720S-0.75K
FR-D720S-1.5K
FR-D720S-2.2K

Mitsubishi FR-D710W-[]K
FR-D710W-0.1K
FR-D710W-0.2K
FR-D710W-0.4K
FR-D710W-0.75K



Embedded modules: AJ65MBTL1N-16D,AJ65MBTL1N-32T,AJ65MBTL1N-32D,AJ65MBTL1N-16DT,AJ65MBTL1N-16T,MFP2N,MFP2AN,MFP3N

Embedded module
AJ65MBTL1N-16D
AJ65MBTL1N-32T
AJ65MBTL1N-32D
AJ65MBTL1N-16DT
AJ65MBTL1N-16T

Features
Placing this product to your circuit bard allows easy development of remote I/O stations

Input modules
AJ65MBTL1N-16D
AJ65MBTL1N-32D

Output modules
AJ65MBTL1N-16T
AJ65MBTL1N-32T

I/O combined module
AJ65MBTL1N-16DT

Dedicated communication LSI   MFP2N   MFP2AN   MFP3N

The actual modules may slightly differ in shapes from the  photo show.


Features
CC-Link compatible devices can be developed easily without worrying about the communication protocol

MFP2N   MFP2AN   MFP3N



Senin, 12 Februari 2018

Remote I/O modules: CL1X4-D1B2,CL1Y4-R1B1,CL1XY8-DT1B2,CL2X8-D1B2,CL2Y8-TP1B2,CL2XY8-DR1B2,CL1Y4-R1B2,CL1XY4-DR1B2,CL1X4-D1B2,CL1X8-D1B2,CL1Y4-T1B2,CL2Y8-TP1B2,CL1Y4-R1B2,CL1Y4-R1B1

Terminal block typeScrew terminal block type

CL1X4-D1B2
CL1Y4-R1B1
CL1XY8-DT1B2

CL2X8-D1B2
CL2Y8-TP1B2
CL2XY8-DR1B2

CL1Y4-R1B2
CL1XY4-DR1B2














Features

  • The industry's most compact size
  • Terminal block cover with nameplate showing connected devices
  • Input modules with positive/negative common shared
  • Terminal block structure enabling simple connection of 2-wire sensors or other loads
  • The modules can be installed in six orientations
Input module
CL1X4-D1B2
CL1X8-D1B2

Output module
CL1Y4-T1B2
CL2Y8-TP1B2
CL1Y4-R1B2
CL1Y4-R1B1

I/O Combined modules
CL1XY4-DT1B2
CL1XY8-DT1B2
CL1XY4-DR1B2
CL1XY8-DR1B2


Spring clamp terminal block type

Features
  • Retightening is not required. The applicable wire size is 0.3 to 1.5 mm (22 to 16 AWG)
  • Two-piece structure (The terminal block section is removable.)
  • Input modules with positive/negative common shared
  • Source type output module (8 points) is available.
  • The modules can be installed in six orientations.





Input modules
CL1X4-D1S2
CL2X8-D1S2

Output modules
CL1Y4-T1S2
CL2Y8-TP1S2
CL2Y8-TPE1S2


Connector type
Sensor connector type
(e-CON)
CL1X4-D1C3
CL2Y8-TP1C2V
CL2XY16-DTP1C5V

CL1Y4-T1C2
CL2X16-D1C3V

CL2X8-D1C3V
CL2Y16-TP1C2V

Features
  • The industry's most compact size
  • DIN rail or screw installation is selectable.
  • The3-Wire sensor can be connected


Input Module
CL1X4-D1C3
CL3X8-D1C3V
CL2X16-D1C3V

Output module
CLY4-T1C2
CL2Y8-TP1C2V
CL2X16-D1C3V

I/O combined modules
CL2XY16-DTP1C5V

MIL connector type
CL2X16-D1M1V
CL2Y16-TP1M1V
CL2X16-D1MJ1V
CL2Y16-TPE1M1V
CL2Y16-TP1MJ1V













Features
  • The industry's most compact size
  • MIL connector used for easy connection to relay terminals, terminals block conversion modules, solenoid valves, and others.
  • Simple module replacement by only removing the the connector
  • Modules with a shared power supply for module and I/O parts are available. (CL2X16-D1MJ1V and CL2Y16-TP1MJ1V) No external power supply for I/O part saves cost and space.
Input module
CL2X16-D1M1V
CL2X16-D1MJ1V

Output modules
CL2Y16-TP1M1V
CL2Y16-TP1MJ1V
CL2Y16-TPE1M1V

Cable type


CL1X2-D1D3S
CL1Y2-T1D2S
CL1XY2-DT1D5S

Features
  • The industry's most compact size
  • The remote I/O module can be stored in a duct with cables.
  • Integration of communication cables and external device connection cables for easy wiring 
  • Cables (50 cm) provided to both  communication and I/O sides.

Input modules
CL1X2-D1D3S

Output modules
CLY2-T1D2S

I/O combined modules
CL1XY2-DT1D5S


Analog Modules
Terminal block type

Analog Input module
Screw terminal module     CL2AD4-B

Features
  • Efficient usage of I/O points (number of occupied stations) is available because the points can be changed by the preset conversion-enabled channel.
  • The dedicated flat cable (50 cm) is directly connected to a module.
Voltage/current input module
CL2AD4-B







Analog Output module
Screw terminal block type    CL2DA2-B
Features

  • Efficient usage of I/O points (number of occupied stations) is available because the points can be changed by the preset conversion-enabled channel.
    • The dedicated flat cable (50 cm) is directly connected to a module.
    Voltage/current output module
    CL2DA2-B








    Dedicated power supply
    Dedicated power supply    CL1PSU-2A

    Features
    • Power  supply dedicated to the CC-Link/LT system with built-in 2A power supply















    Power Adapter
    CL1PAD1
    Features
    • Ensuring a stable power supply from the external  power source (optional) to the CC-Link/LT system














    Master/bridge : QJ61CL12,LJ61CL12,FX3UC-32MT-LT (-2),FX2N-64CL-M,AJ65SBT-CLB,

    MELSEC-Q Series
    QJ61CL12
    Current consumption: 130 mA ( 5V DC, supplied from programmable controller),
                                          28 mA (24V DC, supplied from power adapter)
    Current at start-up    : 70 mA (24V DC, supplied from power adapter.
    Weight                      : 0.09 kg

    MELSEC-L Series
    LJ61CL12


    Current consumption: 160 mA ( 5V DC, supplied from programmable controller),
                                          30 mA (24V DC, supplied from power adapter)
    Current at start-up    : 70 mA (24V DC, supplied from power adapter.
    Weight                      : 0.12 kg



    MELSEC-FX3UC Series
    FX3UC-32MT-LT (-2)

    Current consumption   : 7 W (main module only)
    Built-in power supply  : 24V DC 350mA (for CC-Link/LT network)
    Current at start-up        : 70 mA (24V DC, supplied from power adapter.
    Weight                          : 0.25 kg


    MELSEC-FX Series
    FX2N-64CL-M


    Current consumption: 190 mA ( 5V DC, supplied from programmable controller),
                                          25 mA (24V DC, supplied from power adapter)
    Current at start-up    : 35 mA (24V DC, supplied from power adapter.
     Weight                     : 0.15 kg



    CC-Link to CC-Link/LT bridge module
    AJ65SBT-CLB


    Current consumption: 75 mA ( 5V DC, supplied from programmable controller)
    Current at start-up    : 165 mA (24V DC, supplied from power adapter.
    Weight                      : 0.09 kg





    Remote I/O modules : QS0J65BTB2-12DT,Q0J65BTS2-8D,QS0J65BTS2-4T

    Terminal block type
    Screw terminal block type     QS0J65BTB2-12DT

    Features

    • The system  complying with Category 3 or Category 4 of EN954-1 can be configured by the combination of wiring and parameters.
    • The fail-safe function is equipped. When a failure occurs inside the module, the self-diagnostics function detects the failure and turns OFF the output.
    • A dark test (contact stuck diagnostics) enables an error diagnostics including external safety devices.
    I/O combined module
    QS0J65BTB2-12DT


    Spring clamp terminal block type    Q0J65BTS2-8D   QS0J65BTS2-4T
    Features
    • The remote I/O module which has obtained the highest safety level applicable to programmable controllers, and the safety-related system with high security can be configured.
    • The system complying with Category 3 or Category 4 of EN954-1 can be configured by the combination of wiring and parameters.

    Input Module
    QS0J65BTS2-8D

    Output Module 
    QS0J65BTS2-4T

    Optional parts for I/O modules: A6CON-P214,A6CON-P220,A6CON-P514,A6CON-P520,A6CON-L5P,A6CON-PW5P,A6CON-PW5P-SOD,A6CON-TR11N,A6CON-LJ5P, A6CON-PWJ5P,


    One-touch connector plug

    A6CON-P214
    A6CON-P220
    A6CON-P514
    A6CON-P520

    Applicable models

    AJ65SBTC[]-[] remote I/O module
    AJ65SBTCU[]-[] remote I/O module
    AJ65SBTCU-[]  Analog module







    One-touch connector plug for communication

    A6CON-L5P


    Applicable models  *4
    Only FANC-110SBH, CS-110, 
    and FA-CBL200PBSH can be used














    One-touch connector plug
    for power supply and FG

    A6CON-PW5P
    A6CON-PW5P-SOD


















    One-touch connector plugwith terminating resister.

    A6CON-TR11N














    Online connector for communication 


    A6CON-LJ5P














    Online connector for power supply


    A6CON-PWJ5P


















    Protective cover for sensor connector type (e-CON) module


    A6CVR-VCE8
    A6CVR-VCE16

    Applicable models
    AJ65VBTCE[]-8[] remote I/O module
    AJ65VBTCE[]-16[] remote I/O module













    Protective cover

    A6VCR-8
    A6VCR-16
    A6VCR-32

    Applicable models
    AJ65SBTB[]-[] remote I/O module
    AJ65SBTC[]-[] remote I/O module







    40-pin connector 
    (FCN connector)

    A6CON1
    A6CON2
    A6CON3
    A6CON4

    Applicable models
    AJ65SBTC[]-[] remote I/O module
    AJ65SBTF[]-[] remote I/O module
    AJ65VBTCF-[] remote I/O module

    Protective cap for unusedconnector

    A6CAP-WP2

    Applicable models
    AJ65FBTA[]-[] remote I/O module











    Master Module
    MELSEC-QS Series

    QS0J61BT12

    Occupied I/O points: 32 points
    Can be used only as a master station

    Network interface boards : Q80BD-J61BT11N,Q81BD-J61BT1,ECP-CL2BD,AJ65FBTA-RPH,AJ65SBT-RPS/RPG,AJ65BTS-RPH,AJ65BT-RPI-10A/10B,AJ65SBT-RPT

    Network interface boards
    Q80BD-J61BT11N
    Q81BD-J61BT11















    Features

    • Personal computers and other devices equipped with a PCI Express bus can be incorporated into CC-Link system.
    • Can be used as a CC-Link Ver.2 compatible master station, standby master station local station.
    • Drivers compatible with each of he following OS are included.
    ECP-CL2BD

    Features:
    • Control and monitor CC-Link devices using compact PCI bus interface (cPCI) compatible industrial computers.
    • The CC-Link network interface board can operate as a master or local station and compatible with CC-Link version.2
    • Configure CC-Link parameters using the included software.
    • Function libraries are available to help create user programs.

    Repeater Modules

    AJ65FBTA-RPH
    AJ65SBT-RPS/RPG
    AJ65BTS-RPH
    AJ65BT-RPI-10A/10B
    AJ65SBT-RPT

    Features
    • The following 5 types are available for various applications
    • Low profile waterproof type repeater hub module; Star topology, trunk line extension, spring clamp terminal block type.
    • Spring clamp terminal block type repeater hub module: star topology, trunk line extension, spring clamp terminal block type.
    • Repeater module (T-banch): T-brach, trunk line extension.
    • Optical repeater module: Wiring in high noise environment, trunk line extension.
    • Space optical repeater module: Communication on linear mobile system.