Weight (kg) | 0.20 |
---|---|
Our Part Number | QX40S1 |
Height (mm) | 98 |
Width (mm) | 27.4 |
Depth (mm) | 90 |
Brand | Mitsubishi |
Manufacturer Series | Q |
Manufacturer Range | Q Series |
Short Description | Mitsubishi Q Series 16 point, 24 VDC input (6mA), sink type, 16 points/common |
OMRON , MITSUBISHI , DELTA , LS , WIINTEK WEINVIEW, VEICHI , FUJI ELECTRIC , PROFACE , FATEK , SIEMENS , CUTES , EMERSON , SHIHLIN ELECTRIC , SLANVERT , DANFOSS , MOXA , WACON, YASKAWA Etc
Kontak Kami
KONTAK KAMI : Telpon : 02126071413 Hp/WhatsApp : 081212269831
Perwakilan Jakarta : Gedung LTC Glodok Lantai 1 Blok C30 No.31 Jl.Hayam Wuruk No.127 Jakarta , Indonesia
Jumat, 06 April 2018
MITSUBISHI QX40-S1
Kamis, 05 April 2018
MITSUBISHI QX41-S1
Our Part Number QX41S1
Height (mm) 98
Width (mm) 27.4
Depth (mm) 90
Brand Mitsubishi
Manufacturer Series Q
Manufacturer Range Q Series
Short DescriptionMitsubishi Q Series 32 point, 24 VDC input (4mA), sink type, 32 points/common, high speed
MITSUBISHI QX42
Weight (kg) 0.18
Our Part Number QX42
Height (mm) 98
Width (mm) 27.4
Depth (mm) 90
Brand Mitsubishi
Manufacturer Series Q
Manufacturer Range Q Series
Short DescriptionMitsubishi Q Series 64 point, 24 VDC input (4mA), sink type, 32 points/common
MITSUBISHI QX42-S1
Number of input points 32 points
Isolation method Photocoupler
Rated input voltage 24VDC (+20/-15%, ripple ratio within 5%)
Rated input currentApprox. 4mA
Noise durability First transient noise IEC61000-4-4: 1kV
ON voltage/ON current 19V or higher/4.0mA or higher
OFF voltage/OFF current 9.5V or lower/1.5mA or lower
Input resistance Approx. 5.6k
Shipping Weight(kg) 1.15
MITSUBISHI QX70
Weight (kg) | 0.05 |
---|---|
Our Part Number | QX70 |
Height (mm) | 98 |
Width (mm) | 27.4 |
Depth (mm) | 90 |
Brand | Mitsubishi |
Manufacturer Series | Q |
Manufacturer Range | Q Series |
Short Description | Mitsubishi Q Series 16 point input for sensor, 5-12 VDC input (1.2/3.3mA), sink type, 16 points/common |
MITSUBISHI QX80
Weight (kg) | 0.16 |
---|---|
Our Part Number | QX80 |
Height (mm) | 98 |
Width (mm) | 27.4 |
Depth (mm) | 90 |
Brand | Mitsubishi |
Manufacturer Series | Q |
Manufacturer Range | Q Series |
Short Description | Mitsubishi Q Series 16 point, 24 VDC input (4mA), source type, 16 points/common |
MITSUBISHI QX81
Weight (kg) | 0.16 |
---|---|
Our Part Number | QX81 |
Height (mm) | 98 |
Width (mm) | 27.4 |
Depth (mm) | 90 |
Brand | Mitsubishi |
Manufacturer Series | Q |
Manufacturer Range | Q Series |
Short Description | Mitsubishi Q Series 32 point, 24 VDC input (4mA), source type, 32 points/common |
MITSUBISHI QX82
Weight (kg) 0.18
Our Part Number QX82
Height (mm) 98
Width (mm) 27.4
Depth (mm) 90
Brand Mitsubishi
Manufacturer Series Q
Manufacturer Range Q Series
Short Description Mitsubishi Q Series 64 point, 24 VDC input (4mA), source type, 32 points/common
MITSUBISHI QY18A
Weight (kg) | 0.22 |
---|---|
Our Part Number | QY18A |
Height (mm) | 98 |
Width (mm) | 27.4 |
Depth (mm) | 90 |
Brand | Mitsubishi |
Manufacturer Series | Q |
Manufacturer Range | Q Series |
Short Description | Mitsubishi Q Series 8 point relay, 240 VAC/24 VDC, 2 A contact, all points independent |
MITSUBISHI QY22
Weight (kg) | 0.40 |
---|---|
Our Part Number | QY22 |
Height (mm) | 98 |
Width (mm) | 27.4 |
Depth (mm) | 90 |
Brand | Mitsubishi |
Manufacturer Series | Q |
Manufacturer Range | Q Series |
Short Description | Mitsubishi Q Series 16 point triac, 100-240 VAC, 0.6 A/point, 4.8 A/common, 16 points/common |
MITSUBISHI QY40P
Weight (kg) | 0.16 |
---|---|
Our Part Number | QY40P |
Height (mm) | 98 |
Width (mm) | 27.4 |
Depth (mm) | 90 |
Brand | Mitsubishi |
Manufacturer Series | Q |
Manufacturer Range | Q Series |
Short Description | Mitsubishi Q Series 16 point transistor, 12-24 VDC, 0.1 A/point, 1.6 A/common, sink type, 16 points/common |
MITSUBISHI QY41P
Weight (kg) | 0.15 |
---|---|
Our Part Number | QY41P |
Height (mm) | 98 |
Width (mm) | 27.4 |
Depth (mm) | 90 |
Brand | Mitsubishi |
Manufacturer Series | Q |
Manufacturer Range | Q Series |
Short Description | Mitsubishi Q Series 32 point transistor, 12-24 VDC, 0.1 A/point, 2 A/common, sink type, 32 points/common |
MITSUBISHI QY42P
Weight (kg) | 0.17 |
---|---|
Our Part Number | QY42P |
Height (mm) | 98 |
Width (mm) | 27.4 |
Depth (mm) | 90 |
Brand | Mitsubishi |
Manufacturer Series | Q |
Manufacturer Range | Q Series |
Short Description | Mitsubishi Q Series 64 point transistor, 12-24 VDC, 0.1 A/point, 2 A/common, sink type, 32 points/common |
MITSUBISHI QY10
Weight (kg) 0.22
Our Part Number QY10
Height (mm) 98
Width (mm) 27.4
Depth (mm) 90
Brand Mitsubishi
Manufacturer Series Q
Manufacturer Range Q Series
Short Description Mitsubishi Q Series 16 point relay, 240 VAC/24 VDC, 2 A contact, 16 points/common
NITSUBISHI A6TBXY36
MITSUBISHI A6TBXY36 Product information and technical parameters:
Brand: MITSUBISHI
Name: Connector / terminal conversion module
Model: A6TBXY36For common cathode input module and drain type output module (standard type).
Brand: MITSUBISHI
Name: Connector / terminal conversion module
Model: A6TBXY36For common cathode input module and drain type output module (standard type).
SRAM memory card; capacity: 2M bytes.
Support SD memory card.
High speed universal QCPU support SD memory card,
In order to be able to have a memory card port between SD and PC to easily realize data exchange.
In addition, the SD memory card and the extended SRAM card can be used simultaneously.
Therefore, the extension of the file register using the extended SRAM card,
SD memory card can be used at the same time to carry out the data file record, a large number of annotation data storage, through the memory card to guide operation MITSUBISHI A6TBXY36 A6TBXY36
Simply insert the SD memory card, you can automatically record.
Simply insert the SD in the CPU to save the record setting file, you can automatically start recording MITSUBISHI A6TBXY36.
Even when remote data collection is required,
After receiving a record setting file by mail and copy it to the SD memory card,
Can immediately start recording.
Better user experience data recording function.
Easy to record, no need to program.
Simply through the special configuration tool wizard to easily complete the settings,
The collected data can be saved in CSV format to SD storage card MITSUBISHI A6TBXY36.
Can be effectively used to save the CSV file to facilitate the creation of a variety of reference materials,
Including daily reports, generate reports and general reports.
These data can be applied to the data analysis, tracing, etc..
To record the change of control data without missing.
Data can be collected in a time interval or in a millisecond time interval,
To record the change of the specified control data without any omission.
Therefore, in the event of failure, can quickly determine the cause, the precise action analysis.Input points: 16 points.
Input voltage and current: 8mA AC100-120V (AC100V; 60Hz) /7mA (AC100V; 50Hz).
Response time: 20ms.
16 points / a common end.
18 point terminal station.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.
Easy connection programming tool via ethernet.
Programming toools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings A6TBXY36. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method annd the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection A6TBXY36.
MMITSUBISHI AJ65SBTB1-8D
Specifications:
- Manufacturer: Mitsubishi Electric
- Model: AJ65SBTB1-8D
- Description: I/O Module
- Input Voltage: 24VDC
- Rated Current: 0.5A
- Max. power: 0.8W
- # of Points: 8
- Mounting Type: DIN Rail
- Terminal Type: Single-Wire
MITSUBISHI MR-J4-100A
- Series name : MELSERVO-J4 series
- Command interface : General-purpose interface
- Voltage class : 200V
- Motor rated output [KW] : One
- Servo amplifier form name : MR-J4-100A
- output :-
- Rated voltage: Three-phase AC170 V
- Rated current[A] : 6.0
- Main circuit power input :-
- Voltage and frequency (Note 1): Three-phase or single-phase AC200 V ~ 240 V, 50 Hz / 60 Hz
- Rated current (Note 14)[A] : 5.0
- Allowable voltage fluctuation: Three-phase or single-phase AC170 V ~ 264 V
- Allowable frequency fluctuation: Within ± 5%
- Control circuit power supply input :-
- Voltage and frequency: Single-phase AC200 V ~ 240 V, 50 Hz / 60 Hz
- Rated current[A] : 0.2
- Allowable voltage fluctuation: Single-phase AC170 V ~ 264 V
- Allowable frequency fluctuation: Within ± 5%
- Power consumption [W] : Thirty
- Interface for power : DC24 V ± 10% (required current capacity: including a 0.5 A (CN8 connector signal))
- control method : Sinusoidal wave PWM control and current control system
- Permissible regenerative power :-
- Servo amplifier built-in regenerative resistor (Note 2, 3) [W] : Twenty
- External regenerative resistor (standard accessory) (Note 2, 3, 11, 12)[W] : -
- Dynamic brake : Built-in (Note 4)
- Communication function : USB: connection to a personal computer (MR Configurator2 correspondence)
RS-422 / RS-485: 1 up to 32 axes: n communication (Note 10) - Encoder output pulse : Correspondence (ABZ-phase pulse)
- Analog monitor : 2 channel
- Position control mode :-
- Maximum input pulse frequency: 4 Mpulses / s (the time differential receiver), 200 kpulses / s (when open collector)
- Positioning feedback pulse: Encoder resolution (resolution per rotation servo motor 1): 22-bit
- Command pulse magnification: Electronic gear A / B double A = 1 ~ 16777215, B = 1 ~ 16777215,1 / 10 <A / B <4000
- Positioning complete width setting: 0 pulse ~ ± 65535 pulses (command pulse unit)
- Excessive error: ± 3 rotation
- Torque limit: Parameter settings or set by external analog input (DC0 V ~ + 10 V / maximum torque)
- Speed control mode :-
- Speed control range: Analog speed command 1: 2000, internal speed command 1: 5000
- Analog speed command input: DC0 V ~ ± 10 V / rated speed (rotation speed at 10 V can be changed in the [Pr. PC12])
- Speed variation rate: ± 0.01% or less (load variation: 0% to 100%), 0% (power fluctuation: ± 10%) ± 0.2% or less: only (ambient temperature 25 ° C ± 10 ° C) when the analog speed command
- Torque limit: Parameter settings or set by external analog input (DC0 V ~ + 10 V / maximum torque)
- Torque control mode :-
- Analog torque command input: DC0 V ~ ± 8 V / maximum torque (input impedance: 10 kΩ ~ 12 kΩ)
- Speed limits: Parameter settings or set by external analog input (DC0 V ~ ± 10 V / rated speed)
- Positioning mode : Non-compliant (Note 17)
- Full-closed control : 2-wire communication method (Note 9)
- Machine end encoder interface : Mitsubishi high-speed serial communication
- Servo function : Advanced vibration suppression control Ⅱ, adaptive filter Ⅱ, robust filter, auto-tuning, one-touch adjustment, tough drive function, drive recorder function, machine diagnostic functions, the power monitor function, super trace control (Note 15), lost motion correction function (Note 15 )
- Protective function : Over-current cut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal), servo motor overheating protection, encoder error protection, regenerative error protection, undervoltage protection, instantaneous power failure protection, overspeed protection, excessive error protection, magnetic pole detection and protection, linear servo control error protection
- Safety feature : STO (IEC / EN 61800-5-2)
- Safe performance :-
- Third party certification standards: EN ISO 13849-1 Category 3 PL e, IEC 61508 SIL 3, EN 62061 SIL CL 3, EN 61800-5-2 (Note 20)
- Response performance: 8 ms or less (STO input off → energy cut-off)
- Test pulse input (STO) (Note 7): Test pulse interval: 1 Hz ~ 25 Hz, test pulse off time: Up to 1 ms
- Expected average dangerous failure time (MTTFd): MTTFd ≧ 100 [year] (314a)
- Diagnostic coverage (DC) : DC = medium (Medium), 97.6 [%]
- The average probability of a dangerous failure (PFH) : PFH = 6.4 × 10 -9 [1 / h]
- Overseas Compliance : The correspondence to the international standards and laws.
- Structure (protection grade) : A little over cold, open (IP20)
- Contact mounting :-
- Three-phase power supply input: Yes (Note 6)
- Single-phase power supply input: Improper
- Environmental condition :-
- Ambient temperature: Operation: 0 ° C ~ 55 ° C (no freezing), storage: -20 ° C ~ 65 ° C (no freezing)
- Ambient humidity: Operation / storage: 90% RH or less (non-condensing)
- atmosphere: Indoors (no direct sunlight), that there is no corrosive gas, flammable gas, oil mist, dust and dirt
- elevation: Above sea level 2000 m or less (Note 18)
- Vibration resistance: 5.9 m / s 2, 10 Hz ~ 55 Hz (X, Y, Z each direction)
- Mass :[kg] : 1.4
- Shipping Weight: 2.4 Kg
MITSUBISHI MR-J4-200A
- Series name : MELSERVO-J4 series
- Command interface : General-purpose interface
- Voltage class : 200V
- Motor rated output [KW] :Two
- Servo amplifier form name : MR-J4-200A
- output Rated voltage : Three-phase AC170 V
- Rated current [A] :11.0
- Main circuit power input Voltage and frequency (Note 1) : Three-phase or single-phase AC200 V ~ 240 V, 50 Hz / 60 Hz (Note 16)
- Rated current (Note 14) [A] :10.5
- Allowable voltage fluctuation : Three-phase or single-phase AC170 V ~ 264 V (Note 16)
- Allowable frequency fluctuation : Within ± 5%
- Control circuit power supply input Voltage and frequency : Single-phase AC200 V ~ 240 V, 50 Hz / 60 Hz
- Rated current [A] :0.2
- Allowable voltage fluctuation : Single-phase AC170 V ~ 264 V
- Allowable frequency fluctuation : Within ± 5%
- Power consumption [W] : Thirty Interface for power : DC24 V ± 10% (required current capacity: including a 0.5 A (CN8 connector signal))
- control method : Sinusoidal wave PWM control and current control system
- Permissible regenerative power Servo amplifier built-in regenerative resistor (Note 2, 3) [W] : Hundred
- External regenerative resistor (standard accessory) (Note 2, 3, 11, 12) [W] : >-
- Dynamic brake :Built-in (Note 4)
- Communication function : USB: connection to a personal computer (MR Configurator2 correspondence)
RS-422 / RS-485: 1 up to 32 axes: n communication (Note 10) - Encoder output pulse : Correspondence (ABZ-phase pulse)
- Analog monitor : 2 channel
- Position control mode Maximum input pulse frequency : 4 Mpulses / s (the time differential receiver), 200 kpulses / s (when open collector)
- Positioning feedback pulse : Encoder resolution (resolution per rotation servo motor 1): 22-bit
- Command pulse magnification : Electronic gear A / B double A = 1 ~ 16777215, B = 1 ~ 16777215,1 / 10 <A / B <4000
- Positioning complete width setting : 0 pulse ~ ± 65535 pulses (command pulse unit)
- Excessive error : ± 3 rotation
- Torque limit : Parameter settings or set by external analog input (DC0 V ~ + 10 V / maximum torque)
- Speed control mode Speed control range: Analog speed command 1: 2000, internal speed command 1: 5000
- Analog speed command input: DC0 V ~ ± 10 V / rated speed (rotation speed at 10 V can be changed in the [Pr. PC12])
- Speed variation rate: ± 0.01% or less (load variation: 0% to 100%), 0% (power fluctuation: ± 10%) ± 0.2% or less: only (ambient temperature 25 ° C ± 10 ° C) when the analog speed command
- Torque limit: Parameter settings or set by external analog input (DC0 V ~ + 10 V / maximum torque)
- Torque control mode Analog torque command input : DC0 V ~ ± 8 V / maximum torque (input impedance: 10 kΩ ~ 12 kΩ)
- Speed limits: Parameter settings or set by external analog input (DC0 V ~ ± 10 V / rated speed)
- Positioning mode: Non-compliant (Note 17)
- Full-closed control: 2-wire communication method (Note 9)
- Machine end encoder interface : Mitsubishi high-speed serial communication
- Servo function : Advanced vibration suppression control Ⅱ, adaptive filter Ⅱ, robust filter, auto-tuning, one-touch adjustment, tough drive function, drive recorder function, machine diagnostic functions, the power monitor function, super trace control (Note 15), lost motion correction function (Note 15 )
- Protective function : Over-current cut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal), servo motor overheating protection, encoder error protection, regenerative error protection, undervoltage protection, instantaneous power failure protection, overspeed protection, excessive error protection, magnetic pole detection and protection, linear servo control error protection
- Safety feature : STO (IEC / EN 61800-5-2)
- Safe performance:- Third party certification standards : EN ISO 13849-1 Category 3 PL e, IEC 61508 SIL 3, EN 62061 SIL CL 3, EN 61800-5-2 (Note 20)
- Response performance : 8 ms or less (STO input off → energy cut-off)
- Test pulse input (STO) (Note 7) : Test pulse interval: 1 Hz ~ 25 Hz, test pulse off time: Up to 1 ms
- Expected average dangerous failure time (MTTFd) : MTTFd ≧ 100 [year] (314a)
- Diagnostic coverage (DC) : DC = medium (Medium), 97.6 [%]
- The average probability of a dangerous failure (PFH) : PFH = 6.4 × 10 -9 [1/ h]
- Overseas Compliance : The correspondence to the international standards and laws,Standards Compliant pageplease refer to.
- Structure (protection grade) : A little over cold, open (IP20)
- Contact mounting:- Three-phase power supply input : Yes (Note 6)
- Single-phase power supply input : Improper
- Environmental condition Ambient temperature : Operation: 0 ° C ~ 55 ° C (no freezing), storage: -20 ° C ~ 65 ° C (no freezing)
- Ambient humidity : Operation / storage: 90% RH or less (non-condensing)
- atmosphere : Indoors (no direct sunlight), that there is no corrosive gas, flammable gas, oil mist, dust and dirt
- elevation : Above sea level 2000 m or less (Note 18)
- Vibration resistance : 5.9 m / s 2, 10 Hz ~ 55 Hz (X, Y, Z each direction)
- mass [kg] : 2.1
- Shipping Weight: 3.1 Kg
MITSUBISHI MR-J3-60B
- High-speed controllers for ultra-short positioning times; average speed frequency response 2100Hz
- High-resolution encoders for maximum speed constancy (18 bits 262,144 P/rev)
- Advanced vibration suppression for outstanding adaptation to machine requirements
- Auto tuning for extremely fast setup and installation
- Optimum cost/benefit ratio
- Absolute position encoder included as standard equipment
- Minimum wiring overheads thanks to Plug & Play configuration and automatic motor identification
- Supports global standards
- Shipping Weight: 2.1 kg
MITSUBISHI MR-J3-60A
- High-speed controllers for ultra-short positioning times; average speed frequency response 2100Hz
- High-resolution encoders for maximum speed constancy (18 bits 262,144 P/rev)
- Advanced vibration suppression for outstanding adaptation to machine requirements
- Auto tuning for extremely fast setup and installation
- Optimum cost/benefit ratio
- Absolute position encoder included as standard equipment
- Minimum wiring overheads thanks to Plug & Play configuration and automatic motor identification
- Supports global standards
- Shipping Weight: 2.1 kg
Langganan:
Postingan (Atom)