FP2SH CPU
A high-performance model for high-speed operation
Scanning time of 1ms for 20k steps. With an operating speed at the top of its class, super high-speed processing is made possible. The result is a dramatically decreased tact time and high-speed device.
Large programming capacity of up to 120k steps
Large programming capacities of 60k and 120k are available, depending on the model.
Combine modules like building blocks
I/O units, intelligent units, power supply units and backplanes can be used together for the FP2 and the FP2SH. I/O units can be located anywhere on the backplane.
Optional small PC card is also available
The small PC card is available for programming backup or data memory expansion. This allows you to process great amounts of data.
Built-in comment and real-time clock functions
These functions, optional with the FP2, are built right into the FP2SH.
Specifications
Performance specifications | ||
---|---|---|
PLC type | FP2-C2, FP2-C2L, FP2-C2P, FP2-C3P | |
Inputs/outputs | Central: max. 1600 (with 25 modules) Locally expanded: max. 8172 (via MEWNET-F or S-LINK) | |
Memory | RAM (EPROM or FROM and IC memory card optional) | |
Programme memory |
FP2-C2L 32,000 steps
FP2-C2, FP2-C2P 60,000 steps FP2-C3P 120,000 steps | |
Number of instructions | ||
Basic instructions | 95 | |
High-level instructions | 434 | |
Operating speed | 0.03µs per basic instruction | |
Internal relay (R) | 14,192 | |
Memory | Timer/counter (T/C) | 3,072 |
Data register (DT) | 10,240 words | |
File register (FL) | 32,765 words x 3 banks | |
Master control relay (MCR) | 256 (1st programme: 256 points / 2nd programme: 256 points) | |
Jump labels (JMP + LOOP) | 256 (1st programme: 256 points / 2nd programme: 256 points) | |
Max. main memory programme steps | 1,000 | |
Number of subroutines | 100 | |
Interrupt programme | 1 | |
Time interrupt | 0.5ms to 1.5s | |
Other functions | Test run operation, forced input/output, interrupt processing, batch conversion, function for multiple instructions in RUN mode, calendar time, computer link and modem control via the TOOL and COM port, IC card, 2MB SRAM, flash-EEPROM, ROM operation, comment input function |
Power supply modules
P / N | Voltage | Rating (at 5V side) |
---|---|---|
FP2-PSA1 | 100 - 120V AC | 2.5A |
FP2-PSA2 | 200 - 240V AC | 2.5A |
FP2-PSA3 | 100 - 240V AC | 5A |
FP2-PSD2 | 24V DC | 5A |
Input modules
P / N | I/O Number | Voltage | Connection |
---|---|---|---|
FP2-X16D2 | 16 | 12 - 24V DC | Terminal |
FP2-X32D2 | 32 | 24V DC | Connector |
FP2-X64D2 | 64 | 24V DC | Connector |
Output modules
P / N | I/O Number | Voltage | Connection |
---|---|---|---|
FP2-Y6R | 6 relay | 250V AC / 5A | terminal |
FP2-Y16R | 16 relay | 250V AC / 2A | terminal |
FP2-Y16P |
16 transistor
PNP
| 12-24V DC / 0.5A | terminal |
FP2-Y16T |
16 transistor
NPN
| 12-24V DC / 0.5A | terminal |
FP2-Y32P |
32 transistor
PNP
| 12-24V DC / 0.1A | connector |
FP2-Y32T |
32 transistor
NPN
| 12-24V DC / 0.1A | connector |
FP2-Y64P |
64 transistor
PNP
| 12-24V DC / 0.1A | connector |
FP2-Y64T |
64 transistor
NPN
| 12-24V DC / 0.1A | connector |
I/O mixed modules
FP2-XY64D2T | FP2-XY64D2P | |
---|---|---|
Input | 32 | |
Voltage | 24V DC | |
Response time OFF-> ON | 0.3ms or less | |
Output | 32 | |
I/O number | Transistor NPN | Transistor PNP |
Voltage | 5 to 24V DC | |
Rating | 0.1A (12-24V DC) | 50mA (5V DC) |
Analogue modules
Analogue input modules | |||
---|---|---|---|
P/N | FP2-AD8X | FP2-AD8VI | FP2-RTD |
Input range |
+/-100mV, +/-10V, 1-5V,
thermocouples, RTD
|
+/-10V, 1-5V,
+/-20mA, 4-20mA
|
Pt100,
JPt100,
JPt1000
|
Conversion speed |
500µs/ch voltage
20ms/ch temp.
| 500µs/ch | 20ms/ch |
Accuracy |
+/-0.1% Voltage
+/-0.3% V temp.
| +/-1.0% | +/-0.3% |
Analogue output module | |||
P/N | FP2-DA4 | ||
Outputs | 4 | ||
Output range | -10V to +10V, 0 to 20mA | ||
Conversion speed | 500µs/ch | ||
Accuracy | +/-1.0% (at 0 to 55°C) |
Twenty types of input range such as voltage and temperature sensor are selectable and available for various connection devices (FP2-AD8X). RTD device and thermocouple can be directly connected (FP2-AD8X, FP2-RTD).
Positioning modules
For system-integrated 2- and 4-axis path control. Maximum 4Mpps command yields high-speed and high-precision positioning.
0.005ms high-speed drive reduces tact time.
Feedback pulse count function makes output pulse counting possible for encoders, etc.
JOG positioning control supports a wide range of applications.
Product number | Specifications |
---|---|
FP2-PP21 | Transistor output, 2 axes |
FP2-PP41 | Transistor output, 4 axes |
FP2-PP22 | Line driver output, 2 axes |
FP2-PP42 | Line driver output, 4 axes |
FP2 Positioning units RTEX
- For highly accurate control of network servers with an ultra-compact PLC.
- Great reduction in wiring costs with the use of commercial LAN cable.
- Includes manual pulser input, allowing support for precision teaching.
- Maximum control axes: 112 axes.
- Total support from configuration and startup through to monitoring with the dedicated software tool Configurator PM.
Product number | Specifications |
---|---|
FP2-PN2AN | 2 axes positioning unit RTEX |
FP2-PN4AN | 4 axes positioning unit RTEX |
FP2-PN8AN | 8 axes positioning unit RTEX |
High-speed counter and pulse I/O modules
High-speed counter modules | ||
---|---|---|
Counter | 4 channels, max. 200kHz | |
Interrupt input | 8 points | |
Calculation range | 32-bit | |
P / N | FP2-HSCP | FP2-HSCT |
Input type | PNP | NPN |
Pulse I/O modules | ||
Counter | 4 channels, max. 200kHz | |
Interrupt input | 8 points | |
PWM output | 4 points: 1Hz to 30kHz | |
Pulse output | 4 points: 100kHz | |
P / N | FP2-PXYP | FP2-PXYT |
Output type | PNP | NPN |
Multi communication unit
The FP2-MCU module enables quick and efficient data exchange between Panasonic's FP2 series PLCs and other automation systems. Detachable interface modules make it easy to connect an FP2 PLC to a variety of serial communications devices such as operator terminals, sensor systems, vision systems, temperature controllers, remote maintenance or diagnostic systems or to additional PLCs.
- Fast communication speeds of up to 230Kbps
- Communication protocol options including RS232C, RS422 or RS485
- Double isolation of the communications channel
- Up to 19 modules can be connected in one system
- Transmission distances of up to 1200m can be achieved
Product number | Specification | |
---|---|---|
FP2-CB232 | FP2 communication block (RS232C) Baud rate: 300 to 230400 bps Transmission distance: up to 15m | |
FP2-CB485 | FP2 communication block (RS2485) Baud rate: 300 to 230400 bps Transmission distance: up to 1200m | |
FP2-CB422 | FP2 communication block (RS422) Baud rate: 300 to 230400 bps Transmission distance: up to 400m |
FP2 Multi-wire link module and S-Link module
FP2 multi-wire link module FP2-MW |
---|
|
S-Link module FP2-SL2 |
|
Ethernet-LAN module FP2-ET2
The FP2 ET-LAN module enables data exchange between different types of PLCs with a vendor-independent protocol and a short processing time. TCP/IP establishes logical point-to-point communication between two devices and provides the basis for exchanging information among all areas of production. You can connect 8 Ethernet segments with each other at a transmission speed of up to 100Mbits/s. Three communication interface types are supported: 10 BASE 5, 10 BASE-T, 100 BASE-TX.
FP2 MEWNET-VE Link Unit FP2-VE
With the FP2 MEWNET-VE Link Unit, you can connect PLCs controlled by an FP2SH CPU to our proprietary MEWNET network in VE mode and to other manufacturers’ devices in the FL-net network.
FL-net is an increasingly popular, open technology based on industrial Ethernet and endorsed by the Japan Electrical Manufacturers’ Association. In contrast to standard Ethernet, FL-net guarantees transmission times for data transfer, i.e. real-time data transmission is realized by employing FA link protocol on top of UDP/IP, yielding communication with a baud rate of 10Mbps.
Maximum number of connected link units
- VE mode: 99 units
- FL-net mode: 254 units
Fieldbus Slave Units
Powerful, compact, modular and high performance fieldbus slave units (FSU) are used together with the programmable controllers FP2/FP2SH series.
You can download all the slave data and convenient ready-made function libraries free of charge.
The fieldbus slave units are available for PROFIBUS, DeviceNet, CANopen and Profinet IO. Others are planned for the future.
FP2 Fieldbus Slave Units | ||
---|---|---|
Name | Specifications | Part no. |
FP2 PROFIBUS DP Slave Unit | PROFIBUS | FP2-DPV1-S |
FP2 DeviceNet Slave Unit | DeviceNet | FP2-DEV-S |
FP2 CANopen Slave Unit | CANopen | FP2-CAN-S |
FP2Profinet IO Device Unit | Profinet IO | FP2-PRT-S |
Fieldbus Master Units for PROFIBUS DP, CANopen and DeviceNet
The expansion Fieldbus Master Units (FMU) allow you to integrate FP2 PLCs as Master into your network with a maximum degree of flexibility. The units are available for three bus systems: PROFIBUS, DeviceNet and CANopen. For each network type, ready-made function libraries are available for the programming software Control FPWIN Pro. These libraries drastically shorten the time needed to develop your applications, and consequently save valuable human resource costs.
Product downloads
Cable drawings
Description | Release date | File size | Language |
---|---|---|---|
Communication cable between GT terminals and FP Series Tool port, 2m | 2007-05-01 | 36 KB | English |
Communication cable between GT terminals and FP2/FP2SH COM Port, 2m | 2007-04-01 | 58 KB | English |
Connection cable MINAS A4/A5/A6 to FPG/FP2 positioning module (line driver), 2 axes, DVOP0986W1 | 2011-02-15 | 61 KB | |
Connection cable MINAS-A/A4/A5/A6 to FPG/FP2 positioning module (Transistor) , 2 axes, DVOP0985W1 | 2011-02-15 | 61 KB | English |
FP Modem-56k RS232C Cable for FP Series PLC COM Port with 9-pin Sub-D connector, 0.5m, CABMODPLC211 | 2005-06-27 | 56 KB | English |
FP Modem-56k RS232C cable for FP Series PLC COM port with screw terminal, 0.5m, CABMOD111D | 2007-03-22 | 62 KB | English |
Programming cable for FP and GT series (MINI-DIN to 9 PIN SUB-D), 3m, AFC8513 | 2007-03-19 | 35 KB | English |
Data sheets
Description | Release date | File size | Language |
---|---|---|---|
FP2SH series: 32k steps type | 244 KB | English | |
Short Form FP2/FP2SH Series | 5.39 MB | English |
Flyers
Description | Release date | File size | Language |
---|---|---|---|
Fieldbus Master Units for FPΣ (Sigma) and FP2 | 290 KB | English | |
Slave Units for FPΣ (Sigma) and FP2 | 570 KB | English |
Libraries
Description | Release date | File size | Language |
---|---|---|---|
Fieldbus Master Module (FMU) Library for PROFIBUS-DP, DeviceNet and CANopen (FP-Sigma, FP2) | 2008-08-01 | 122 KB | English |
PROFIBUS, DeviceNet, CANopen, BACnetIP, BACnetMSTP and PROFINET IO Library for configuration of FP2 and FPG Fieldbus Slave Units. GSD, EDS and GSDML files are included. FPWIN Pro Ver.5.2.3 or higher needed. | 2013-04-01 | 844 KB | English |
Manuals
Shortforms
Description | Release date | File size | Language |
---|---|---|---|
Short Form Programmable Logic Controllers | 2016-10-20 | 2.47 MB | English |