Kontak Kami

KONTAK KAMI : Telpon : 02126071413 Hp/WhatsApp : 081212269831 Perwakilan Jakarta : Gedung LTC Glodok Lantai 1 Blok C30 No.31 Jl.Hayam Wuruk No.127 Jakarta , Indonesia

Kamis, 23 Agustus 2018

Networking & communication

Networking & decentralization




















Panasonic Ethernet

All relevant factory automation products communicate with each other via Ethernet. Main focus is the connection to the IT-world and the use of its advantages:
- uses existing networks, saves wiring
- reaches almost every point of the world via Internet
- standard software tools already existing on your PC
- remote control, monitoring and programming 
The FP Web-Server brings together all the FP series controllers with Ethernet an all the possibilities of this new technology. In addition, for the FP2 / FP2SH series controllers, Panasonic provides high-end ET-LAN modules for particularly fast communication on the Ethernet network. 

Panasonic BACnet

Our BACnet products are available as two different types of interface units: BACnet/IP and MS/TP. All FP-Sigma CPUs can thus be connected via BACnet. Naturally, other interface units for inputs and outputs just as other fieldbus slave units can be used, for example to establish a gateway between IEC60870-5 and BACnet.
  • Compact size measuring just 30x90x60 mm (WxHxD) 
  • Baud rate for BACnet/IP: 10/100Mbps 
  • Baud rate for MS/TP: 9600 – 76,800Mbps 
  • Bus interface fully insulated 
  • Max. I/Os words: 128 
  • Additional diagnostic features for the fieldbus slaves

Panasonic PROFIBUS

Implies manufacturer-independent communication at the field level. The European PROFIBUS standard EN50170 guarantees compatibility of all certified devices. 150 companies offer more than 800 products with PROFIBUS interfaces.
Specification according to the standard EN50170:
- FP0 DP slave unit or remote I/O unit 
- FP-Sigma DP slave units (FNS*)
- FP2/FP2SH DP slave unit (FNS*)
- FP-Sigma DP master unit
- FP2/FP2SH DP master unit
- PROFIBUS interfaces for VF-CE inverters and 8200 vector series inverters

*FNS = Flexible Netork Slave with exchangeable communication module, also for CANopen and DeviceNET.

Panasonic CANopen

Implies manufacturer-independent communication at field level. The CANopen standard guarantees compatibility of all certified devices. 
Specification according to the standard EN 50325-4:
- FP2/FP2SH CANopen-Master 
- FP-Sigma CANopen-Master
- FP-Sigma CANopen-Slave
- FP2/FP2SH CANopen-Slave 

Panasonic DeviceNet 

Implies manufacturer-independent communication at field level. The DeviceNet standard guarantees compatibility of all certified devices. 
Specification according to the standard ODVA:
- FP2/FP2SH DeviceNet-Master 
- FP-Sigma DeviceNet-Master
- FP-Sigma DeviceNet-Slave
- FP2/FP2SH DeviceNet-Slave 

Panasonic Profinet IO

Implies manufacturer-independent real-time industrial ethernet communication. Two RJ45-port connectors with an integrated 2-port switch enable communication within any network topology (bus, ring, tree, star) reducing the need for expensive external switches. 
Specification according to IEC 61158/IEC 61784-1. Panasonic Profinet IO Device Unit complies with Profinet IO conformance class B.  
- FP2/FP2SH Profinet IO-Device
- FP-Sigma Profinet IO-Device

MEWNET-W

Communication at process level between PLC systems using low-cost two-wire circuitry. Data exchange via RS485 interface (Token Bus). The network is the best choice for an economical PLC link such as an I/O status transfer among machines. 
Transmission speed: 500Kbps
Max. number of stations: 32
Max. distance: 800m

MEWNET-W2

PLC link with economical twisted-pair cables (Token-Bus). In addition to PLC link functions, a data transfer function that allows a PLC program to be used to set the memory of the transfer source and the destination is provided. 
Transmission speed: 250Kbps or 500Kbps selectable 
Max. number of stations: 32
Max. distance: 800m at 500Kbps or 1.200m at 250Kbps

Modbus

Standardized industrial network in accordance with the Modbus RTU, the world's de-facto standard. The individual communication participants e.g. PLCs, HMIs, temperature controller, can be networked point to point or as multidrop configuration.
Transmission speed: up to 115.2Kbps
Max. number of stations: 99
Max. distance: 1,200m

C-NET

Computer-Network
LOW COST network in master / slave process for communication between computer and PLCs.
Transmission rate: 9.6/19.2KBd
Max. number of stations: 32
Max. distance: 1.200m

MEWNET-TR

The sensor/actuator bus
MEWNET-TR provides low-cost transmission of digital I/O information at
sensor / actuator and field level between a master connection assembly and decentralized terminals (slaves).
Transmission rate: 500Kbps
Max. number of stations: 32
Max. distance: 700m using twisted pair cable

TR-NET

The intelligent sensor / actuator bus terminals in the TR-NET from Panasonic
make cost-intensive network masters superfluous in compact automation
projects. Digital information from a sensor station is transmitted via two-wire
circuitry directly to the associated station.
Transmission rate: 500Kbps
Max. number of stations: 32 (per master unit)
Max. distance: 700m using twisted pair cable

MEWNET-F

Decentralised I/O
MEWNET-F is a remote I/O system which can control differently located inputs and outputs with 2-wire cable. This system is best suitedfor a network in which I/Os set up in different spots: a control box in a distant place, for example. 
Transmission rate: 500Kbps
Max. number of stations: 32
Max. distance: 700m

S-LINK

The serial I/O bus for up to 128 components per port, uses two-wire signaling
circuits and connects components in the multidrop system to reduce networking costs.
Transmission speed: 28.5Kbit/s,
Max. number I/Os: 128/channel
Max. distance: 200m (400m using a booster)

Product downloads

Cable drawings

DescriptionRelease dateFile sizeLanguage
Communication cable between GT terminals and FP Series Tool port, 2m2007-05-0136 KBEnglish
Communication cable between GT terminals and FP2/FP2SH COM Port, 2m2007-04-0158 KBEnglish
FP Modem-56k RS232C Cable for FP Series PLC COM Port with 9-pin Sub-D connector, 0.5m, CABMODPLC2112005-06-2756 KBEnglish
FP Modem-56k RS232C cable for FP Series PLC COM port with screw terminal, 0.5m, CABMOD111D2007-03-2262 KBEnglish
Other communication cables GT Series to PLCs, AIGT8142(Panasonic mini DIN-5), AIGT8152(Mitsubishi FX RS422) and AIGT8175(Mitsubishi FX RS422)2007-04-01246 KBEnglish
Programming cable for FP and GT series (MINI-DIN to 9 PIN SUB-D), 3m, AFC85132007-03-1935 KBEnglish
RS232 cable between FP Modem-56k and Tool port, 2m, CABMODPLC311D2007-03-2280 KBEnglish
RS485 Communication Cable, GT Series to Siemens S7-200 PLC, legth 2m, AIGT81S2D2007-04-27330 KBEnglish

Data sheets

DescriptionRelease dateFile sizeLanguage
FP Web-Server280 KBEnglish
Version 7.02의 새로운 기능 Control FPWIN Pro new Features - Korean version146 KBEnglish

Libraries

DescriptionRelease dateFile sizeLanguage
Control Configurator MS lib Version 1.102: This software is used to setup a GSM alarm message system which was programmed by FPWIN Pro GSM alarm notification library (NCL-CCMS-LIB).2012-11-0124.01 MBEnglish, German, Italian, Spanish
Fieldbus Master Module (FMU) Library for PROFIBUS-DP, DeviceNet and CANopen (FP-Sigma, FP2)2008-08-01122 KBEnglish
Fieldbus Master Units (FMU) Profibus, Profinet, CANopen and DeviceNet for FP7. Libraries, Samples and Docu V. 1.0.1.0 (for the use in FPWIN Pro 7).2018-07-034.34 MBEnglish
FP0DPS2 PROFIBUS DP-Slave GSD-File2008-08-012 KBEnglish
FPWIN Pro GSM alarm notification library (NCL-CCMS-LIB) version 1.200, Windows Configuration software (SetupControlConfiguratorMSLib1.102) and manuals. The FPWIN Pro libraries in "NCL-CCMS-LIB" contain function blocks to fulfill the following tasks: • Sending of SMS text messages, facsimiles, or mails • Receiving SMS text messages • Sending of DTMF tones (Dual Tone Multifrequency Dialing) • Requesting the signal level and registration status of the GSM terminal. In addition, the libraries contain a readily programmed GSM alarm notification system.2015-09-0229.49 MBEnglish, German
Motion -& Communication Library for MINAS A5N/A6N Series, RTEX, Version 2.2.0.0, Included Demo Program. Supported PLCs: FP-Sigma2018-02-12782 KBEnglish
Motion Control Library for MINAS LIQI / A5 / A6 Series, Pulse Output Control with compact PLCs, Version 1.0, Included Demo Program. Supported PLCs: FP0R, FP-Sigma, FPX, FP72017-12-121.26 MBEnglish
PEW-CONTROL-DRIVER-A4-VIA-RS485 Library2009-07-0155 KB
PEW_A5_A6_RS232 Library2015-04-283.44 MBEnglish
PROFIBUS, DeviceNet, CANopen, BACnetIP, BACnetMSTP and PROFINET IO Library for configuration of FP2 and FPG Fieldbus Slave Units. GSD, EDS and GSDML files are included. FPWIN Pro Ver.5.2.3 or higher needed.2013-04-01844 KBEnglish
Solar Tracking Library2011-02-012.1 MB
User library 3964R 3.02 - function blocks for 3964R/RK512 procedure (incl. Engl. a. German online) ( TB-3964R )2016-12-124.56 MBEnglish, German
User library ACRON - function blocks ACRON / ACRON connect ( incl. German online)4.45 MB
User library GPRS - function blocks for GPRS communication (for FPWIN Pro 5 and 6, incl. English and German online help)2015-08-2416.62 MBEnglish, German, Italian, Spanish
User library GPRS 3.101 - function blocks for GPRS communication (for FPWIN Pro 7 or newer, incl. English and German online help)2016-09-2118.18 MBEnglish, German, Italian, Spanish
User library IEC60870 2.611- function blocks for remote control with the IEC 60870-5 standard protocol (for FPWIN Pro 5 and 6, incl. English and German online help)2016-05-0916.31 MBEnglish, German
User library IEC60870 3.11- function blocks for remote control with the IEC 60870-5 standard protocol (for FPWIN Pro 7 and newer, incl. English and German online help)2016-05-0916.84 MBEnglish, German
User library Modbus RTU - function blocks for Modbus communication with FP-G(FPG951)MCU, (incl. English online help)2015-04-28173 KBEnglish
User library Modbus RTU - function blocks for Modbus communication with FP2, FP2 MCU, FP0 and FP-G(FPG951)MCU, not necessary for FP0R, FP-X, FP-G and FP7, (incl. English, German a. Italian online help)2015-04-075.77 MBEnglish, German, Italian
User library Modem communication for dial-up a. leased-line incl. Engl. a. German online help)4.99 MB
User library ODP - Software functions for a GPRS ODP connection( incl. German online help)4.12 MB
User library PTC - function blocks for process and temperature control (incl. German a. English online help)2013-02-015.5 MBEnglish
User library SEAB-1F - Software functions to communicate to AEG-telecontrol (master, slave (incl. German online)2014-09-234.7 MBEnglish, German
User library timelib 4.1 - function blocks for UNIX/IEC-compliant time for FPWIN Pro 6 and FPWIN Pro 7 (incl. German online help)2016-12-122.66 MB
User library MBUS - M-Bus master software functions (incl. German online) ( TB-MBUS )2015-01-073.99 MBEnglish
VF-CE Inverter PROFIBUS Library: For fast and easy control of your VF-CE inverter in a PROFIBUS-DP network.2006-07-011.32 MBEnglish

Manuals

DescriptionRelease dateFile sizeLanguage
Announcement of discontinued production FP WEB-server unit2007-03-0131 KBEnglish
Announcement of discontinued PROFIBUS products2007-03-01706 KBEnglish
Ethernet Communication (AFPX-COM5)1.38 MBEnglish
FP ISDN Technical Manual2008-01-01642 KBEnglish
FP Web-Server Hardware/Configurator, ACGM0151V48EN2016-09-016.06 MBEnglish
FP-Series MEWNET Link Unit P-Type Technical Manual1993-05-011015 KBEnglish
FP-X Ethernet Communication2010-02-012.19 MBEnglish
FP2 ET-LAN Configurator ET Guide Book, ARCT1F341E42013-07-01722 KBEnglish
FP2 ET-LAN Unit Technical Manual, ARCT1F322E-72013-12-0111.13 MBEnglish
FP2 MEWNET-VE Link Unit Technical Manual, ARCT1F435E42013-07-016.11 MBEnglish
FP2 Multi Communication Unit Technical Manual, ARCT1F396E62013-07-017.64 MBEnglish
FP2 Serial Data Unit Hardware Manual1.73 MBEnglish
FP2/FP-Sigma Fieldbus Master Units Technical Manual, ACGM0161V0EN2008-07-011.79 MBEnglish
FP2/FP-Sigma Fieldbus Slave Units Technical Manual2012-12-012.21 MBEnglish
FP7 Communication Cassette (Ethernet) User's Manual, WUME-FP7CCET-012013-12-011.59 MBEnglish
FP7 Ethernet Communication Cassette User's Manual, WUME-FP7CCET-012013-12-011.59 MBEnglish
FP7 Fieldbus Master Units(PROFIBUS DP Master, DeviceNet Master, CANopen Master and PROFINET IO-Controller) User's Manual, ACGM0706V1EN2016-02-161.64 MBEnglish
MEWNET W2 Software Protocol1999-11-011.77 MBEnglish
MEWNET-F Remote I/O System Technical Manual, FAF35E62013-07-013.61 MBEnglish
MEWTOCOL Protocol2010-03-011.86 MBEnglish
PCWAY Operation Guide Book, ARCT1F391E62013-07-012.54 MBEnglish
PCWAY User's Manual, ARCT1F392E-72013-07-0116.48 MBEnglish
S Link Address Setting Remote Controller SL-VAR1 (CMJEC-SLVAR1)2015-07-13298 KBEnglish
S-Link Construction Manual2002-10-015.04 MBEnglish
S-Link V User Manual, ME-SLINKV-62018-01-195.74 MBEnglish
SL-VPCI Instruction Manual (S-LINK V PCI Bus and Control Board)2014-02-015.74 MBEnglish
VF-CE Inverter PROFIBUS AIF Module DP Slave Operating Instructions2001-04-01394 KBEnglish
VF-CE Inverter PROFIBUS FIF Module DP Slave Operating Instructions2003-07-01852 KBEnglish

Shortforms

DescriptionRelease dateFile sizeLanguage
Short Form Programmable Logic Controllers2016-10-202.47 MBEnglish

Software

DescriptionRelease dateFile sizeLanguage
Control Configurator ET Ver 1.01 Update: This software is used to upgrade Ver 1.00 to Ver 1.01.2011-06-014.85 MBEnglish
Control Configurator FM for FP7 Network Configurator including diagnostic functions for FP7 Fieldbus Master Units, 590 MB48 KB
Control Configurator PM Ver. 1.22 difference file: It is used to upgrade Ver.1.00 to Ver.1.22. This file does not work on its own. To install this software, Control Configurator PM Ver.1.00 must already be installed.2011-11-019.87 MBEnglish
Control Configurator WD Version 1.74: setting software for Ethernet communication of FP7, Data Logger Light, PV200/500, HL-C21C, GT32T1/703/704, AFPX-COM5, LG-GS, KW2M-A/KW2M-X and KS1.2016-12-015.43 MBEnglish
FP Loader Version 2.50: A software tool designed to download program files created with FPWIN GR or FPWIN Pro to a PLC. It supports all FP-Series PLCs without FP7.2011-06-21320 KBEnglish
FP Web Configurator Tool Ver 2.840 Update: This software is used to update an existing installation Ver. 2.x to Ver. 2.84090.79 MBEnglish
FP7 CPU EtherNet/IP EDS files2016-06-15276 KB
FPConnect OCX, Vers. 2.0.6.1, Visual Studio 2015 C++ redistributable files, PxMEWNET manager. With example projects for Visual Studio (VBA, C++, C#), Excel and Power Point.2018-01-1240.52 MBEnglish
FPWIN GR Ver.2.92: This software is used to upgrade FPWINGR Ver.2.0 or later to Ver. 2.92(serial number: AFPS10520-0234579).2014-09-0139.55 MBEnglish
FPWIN Pro 6, version 6.414 Online-Help update – English2013-08-0153.47 MBEnglish
FPWIN Pro 6, version 6.414 Update: This software is used to update all older FPWIN Pro 6 versions.2013-10-2326.67 MB
FPWIN Pro 7, version 7.2.3.0 Update(incl. help): This software is used to update all older FPWIN Pro 7 versions. For Windows 7, 8.x and 10.2018-06-01440.92 MBEnglish, German, Italian, Spanish, French
FPWIN Pro 7, version 7.2.3.0, free basic version that supports all PLCs including the FP7, PLC program length limitation 10000 steps. For Windows 7, 8.x and 10.2018-06-01438.61 MBEnglish, German, Italian, French, Spanish
GSD, EDS and GSDML files for Fieldbus network slaves Profibus DP(FP0DPS2D, FPG-DPV1-S a. FP2-DPV1-S), CANopen(FPG-CAN-S a. FP2-CAN-S), DeviceNet(FPG-DEV-S a. FPG-DEV-S) and Profinet(FPG-PRT-S a. FP2-PRT-S)16 KBEnglish
KS1 Signal Converter Firmware Ver. 1.042011-04-01228 KB
PCWAY Demo Version 2.80 is a data monitoring, logging and setting software based on Microsoft Excel.2011-11-0130.22 MBEnglish
PCWAY software update: The difference file 2.85 updates PCWAY Ver. 2.5 to Ver. 2.84. For Windows 7, 8.x and 10.2017-07-1947.73 MBEnglish
TB-Symkeys HM 2.52, Flowchart-, Button-, Graphic- and FPWIN Pro Library incl. samples for HMWIN and FPWIN Pro.2017-05-2411.38 MBEnglish
Web Datalogger Unit (DLU) Firmware Ver. 2.58 (for AFL1200)2011-04-01566 KBEnglish