PLC OMRON CP1L-EL20DT-D


International Standards

  • The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, KC: KC Registration, and CE: EU Directives.
  • Contact your OMRON representative for further details and applicable conditions for these standards.

CPU Units

Built-in Ethernet port

CPU UnitSpecificationsModelStand- 
ards
CPU typePower 
supply
Output methodInputsOut- 
puts
CP1L-EM 
CPU Units 
with 
40 Points 
1916_lu_1_1
Memory capacity: 
10K steps 
High-speed counters: 
100 kHz, 4 axes 
Pulse outputs: 
100 kHz, 2 axes 
(Models with transistor 
outputs only)
DC 
power 
supply
Relay output2416CP1L-EM40DR-DUC1, N, 
L, CE
Transistor output 
(sinking)
CP1L-EM40DT-D
Transistor output 
(sourcing)
CP1L-EM40DT1-D
CP1L-EM 
CPU Units 
with 
30 Points 
1916_lu_1_2
Memory capacity: 
10K steps 
High-speed counters: 
100 kHz, 4 axes 
Pulse outputs: 
100 kHz, 2 axes 
(Models with transistor 
outputs only)
DC 
power 
supply
Relay output1812CP1L-EM30DR-DUC1, N, 
L, CE
Transistor output 
(sinking)
CP1L-EM30DT-D
Transistor output 
(sourcing)
CP1L-EM30DT1-D
CP1L-EL 
CPU Units 
with 
20 Points 
1916_lu_1_3
Memory capacity: 
5K steps 
High-speed counters: 
100 kHz, 4 axes 
Pulse outputs: 
100 kHz, 2 axes 
(Models with transistor 
outputs only)
DC 
power 
supply
Relay output128CP1L-EL20DR-DUC1, N, 
L, CE
Transistor output 
(sinking)
CP1L-EL20DT-D
Transistor output 
(sourcing)
CP1L-EL20DT1-D

Built-in USB port

CPU UnitSpecificationsModelStandards
CPU typePower
supply
Output methodInputsOutputs
CP1L-M CPU 
Units with 
60 Points 
1916_lu_2_1
Memory capacity: 
10K steps 
High-speed counters: 
100 kHz, 4 axes 
Pulse outputs: 
100 kHz, 2 axes 
(Models with transistor
outputs only)
AC 
power 
supply
Relay output3624CP1L-M60DR-AUC1, N, L,
CE, KC
Transistor output
(sinking)
CP1L-M60DT-A
DC 
power 
supply
Relay outputCP1L-M60DR-D
Transistor output
(sinking)
CP1L-M60DT-D
Transistor output
(sourcing)
CP1L-M60DT1-D
CP1L-M CPU 
Units with 
40 Points 
1916_lu_2_2
Memory capacity: 
10K steps 
High-speed counters: 
100 kHz, 4 axes 
Pulse outputs: 
100 kHz, 2 axes 
(Models with transistor
outputs only)
AC 
power 
supply
Relay output2416CP1L-M40DR-AUC1, N, L,
CE, KC
Transistor output
(sinking)
CP1L-M40DT-A
DC 
power 
supply
Relay outputCP1L-M40DR-D
Transistor output
(sinking)
CP1L-M40DT-D
Transistor output
(sourcing)
CP1L-M40DT1-D
CP1L-M CPU 
Units with 
30 Points 
1916_lu_2_3
Memory capacity: 
10K steps 
High-speed counters: 
100 kHz, 4 axes 
Pulse outputs: 
100 kHz, 2 axes 
(Models with transistor
outputs only)
AC 
power 
supply
Relay output1812CP1L-M30DR-AUC1, N, L,
CE, KC
Transistor output
(sinking)
CP1L-M30DT-A
DC 
power 
supply
Relay outputCP1L-M30DR-D
Transistor output
(sinking)
CP1L-M30DT-D
Transistor output
(sourcing)
CP1L-M30DT1-D
CP1L-L CPU 
Units with 
20 Points 
1916_lu_2_4
Memory capacity: 
5K steps 
High-speed counters: 
100 kHz, 4 axes 
Pulse outputs: 
100 kHz, 2 axes 
(Models with transistor
outputs only)
AC 
power 
supply
Relay output128CP1L-L20DR-AUC1, N, L,
CE, KC
Transistor output
(sinking)
CP1L-L20DT-A
DC 
power 
supply
Relay outputCP1L-L20DR-D
Transistor output
(sinking)
CP1L-L20DT-D
Transistor output
(sourcing)
CP1L-L20DT1-D
CP1L-L CPU 
Units with 
14 Points 
1916_lu_2_5
Memory capacity: 
5K steps 
High-speed counters: 
100 kHz, 4 axes 
Pulse outputs: 
100 kHz, 2 axes 
(Models with transistor
outputs only)
AC 
power 
supply
Relay output86CP1L-L14DR-AUC1, N, L,
CE, KC
Transistor output
(sinking)
CP1L-L14DT-A
DC 
power 
supply
Relay outputCP1L-L14DR-D
Transistor output
(sinking)
CP1L-L14DT-D
Transistor output
(sourcing)
CP1L-L14DT1-D
CP1L-L CPU 
Units with 
10 Point 
1916_lu_2_6
Memory capacity: 
5K steps 
High-speed counters: 
100 kHz, 4 axes 
Pulse outputs: 
100 kHz, 2 axes 
(Models with transistor
outputs only)
AC 
power 
supply
Relay output64CP1L-L10DR-AUC1, N, L,
CE, KC
Transistor output
(sinking)
CP1L-L10DT-A
DC 
power 
supply
Relay outputCP1L-L10DR-D
Transistor output
(sinking)
CP1L-L10DT-D
Transistor output
(sourcing)
CP1L-L10DT1-D
Note: 1. Refer to "Models and Software Versions" about supported software. 
            2. Refer to "Option Unit Specifications" about supported Option Units.
Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.
EtherNet/IPTM is the trademarks of ODVA. 
Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.

Options for CPU Units

NameSpecificationsModelStand- 
ards
RS-232C 
Option Board
1916_lu_3_1Can be mounted in either CPU Unit Option Board slot 1 or 2. *1CP1W-CIF01UC1, N, 
L, CE, 
KC
RS-422A/485 
Option Board
1916_lu_3_2CP1W-CIF11
RS-422A/485 
(Isolated-type) 
Option Board
1916_lu_3_3CP1W-CIF12-V1
Ethernet 
Option Board
1916_lu_3_4Can be mounted in either CPU Unit Option Board slot 1 or 2. 
*1 *2 *4
CP1W-CIF41
Analog Input 
Option Board
1916_lu_3_5Can be mounted in either CPU Unit Option Board slot 1 or 2. *3 
2 analog inputs. 0-10V(Resolution:1/4000), 0-20mA (Resolution: 
1/2000).
CP1W-ADB21
Analog Output 
Option Board
1916_lu_3_6Can be mounted in either CPU Unit Option Board slot 1 or 2. *3 
2 analog outputs. 0-10V (Resolution:1/4000).
CP1W-DAB21V
Analog I/O 
Option Board
1916_lu_3_7Can be mounted in either CPU Unit Option Board slot 1 or 2. *3 
2 analog inputs. 0-10V (Resolution:1/4000), 0-20mA (Resolution: 
1/2000). 
2 analog outputs. 0-10V (Resolution:1/4000).
CP1W-MAB221
LCD Option 
Board
1916_lu_3_8Can be mounted only in the CPU Unit Option Board slot 1. *1CP1W-DAM01
Memory 
Cassette
1916_lu_3_9Can be used for backing up programs or auto-booting.CP1W-ME05MUC1, N, 
L, CE
*1. Cannot be used for the CP1L-L10. 
*2. When using CP1W-CIF41 Ver.1.0, one Ethernet port can be added. 
*3. CP1L-EM/EL only. 
*4. Cannot be used for the CP1L-EM/EL.

Programming Devices

NameSpecificationsModelStand- 
ards
Number 
of 
licenses
Media
FA 
Integrated 
Tool 
Package 
CX-One Lite 
Version 4.[]
CX-One Lite is a subset of the complete CX-One 
package that provides only the Support Software 
required for micro PLC applications. 
CX-One Lite runs on the following OS. 
OS: Windows XP (Service Pack 3 or higher, 32-bit 
version)/Windows Vista (32-bit/64-bit version)/ 
Windows 7 (32-bit/64-bit version)/Windows 8 (32- 
bit/64-bit version)/Windows 8.1 (32-bit/64-bit 
version)/Windows 10 (32-bit/64-bit version) 

CX-One Lite Ver. 4.[] includes Micro PLC Edition 
CX-Programmer Ver. 9.[].
1 licenseDVDCXONE-LT01D-V4---
FA 
Integrated 
Tool 
Package 
CX-One 
Ver.4.[]
CX-One is a package that integrates the Support 
Software for OMRON PLCs and components. CX- 
One runs on the following OS. 
OS: Windows XP (Service Pack 3 or higher, 32-bit 
version)/Windows Vista (32-bit/64-bit version)/ 
Windows 7 (32-bit/64-bit version)/Windows 8 (32- 
bit/64-bit version)/Windows 8.1 (32-bit/64-bit 
version)/Windows 10 (32-bit/64-bit version) 

CX-One Ver. 4.[] includes CX-Programmer Ver. 9.[].
1 license 
*1
DVDCXONE-AL01D-V4---
Programming 
Device 
Connecting 
Cable for 
CP1W-CIF01 
RS-232C 
Option 
Board *2
Connects Personal Computers, D-Sub 9-pin 
(Length: 2.0 m)
For anti-static 
connectors
XW2Z-200S-CV---
Connects Personal Computers, D-Sub 9-pin 
(Length: 5.0 m)
XW2Z-500S-CV
Connects Personal Computers, D-Sub 9-pin (Length: 2.0 m)XW2Z-200S-V
Connects Personal Computers, D-Sub 9-pin (Length: 5.0 m)XW2Z-500S-V
Note: 1. Refer to "Models and Software Versions" about supported software. 
           2. The CX-One and CX-One Lite cannot be simultaneously installed on the same computer. 
*1. Multi licenses (3, 10, 30, or 50 licenses) and DVD media without licenses are also available for the CX-One. 
*2. Cannot be used with a peripheral USB port. 
      To connect to a personal computer via a peripheral USB port, use commercially-available USB cable (A or B type, male).
The following tables lists the Support Software that can be installed from CX-One
Support Software in CX-OneCX-One Lite Ver.4.[]CX-One Ver.4.[]
Micro PLC Edition CX-ProgrammerVer.9.[]YesNo
CX-ProgrammerVer.9.[]NoYes
CX-IntegratorVer.2.[]YesYes
Switch Box UtilityVer.1.[]YesYes
CX-ProtocolVer.1.[]NoYes
CX-SimulatorVer.1.[]YesYes
CX-PositionVer.2.[]NoYes
CX-Motion-NCFVer.1.[]NoYes
CX-Motion-MCHVer.2.[]NoYes
CX-MotionVer.2.[]NoYes
CX-DriveVer.2.[]YesYes
CX-Process ToolVer.5.[]NoYes
Faceplate Auto-Builder for NSVer.3.[]NoYes
CX-DesignerVer.3.[]YesYes
NV-DesignerVer.1.[]YesYes
CX-ThermoVer.4.[]YesYes
CX-ConfiguratorFDTVer.1.[]YesYes
CX-FLnetVer.1.[]NoYes
Network ConfiguratorVer.3.[]YesYes
CX-ServerVer.4.[]YesYes

Models and Software Versions

The following versions of the CX-One, CX-Programmer are required.
ModelCX-OneCX-Programmer
CP1L-EM40[][]-[] 
CP1L-EM30[][]-[] 
CP1L-EL20[][]-[]
*1Ver. 4.25 or higherVer. 9.40 or higher
CP1L-M60[][]-[]*2Ver. 2.11 or higherVer. 7.20 or higher
CP1L-M40[][]-[] 
CP1L-M30[][]-[] 
CP1L-M20[][]-[] 
CP1L-L14[][]-[]
*2Ver. 2.10 or higherVer. 7.10 or higher
CP1L-L10[][]-[]*2Ver. 2.13 or higherVer. 7.30 or higher
*1. Update The CX-Programmer version automatically from the website using CX-Programmer version 9.0 (included with 
       CX-One version 4.0). 
*2. Update The CX-Programmer version automatically from the website using CX-Programmer version 7.0 (included with 
       CX-One version 2.0).

Expansion Units

Product 
name
InputsOutputsOutput typeModelStand- 
ards
Input Unit8--24 VDC InputCP1W-8EDU, C, N, 
L, CE, 
KC
Output Units 
1916_lu_7_1
--8RelayCP1W-8ER
Transistor (sinking)CP1W-8ET
Transistor (sourcing)CP1W-8ET1
--16RelayCP1W-16ERN, L, 
CE, KC
Transistor (sinking)CP1W-16ET
Transistor (sourcing)CP1W-16ET1
--32RelayCP1W-32ERN, L, 
CE, KC
Transistor (sinking)CP1W-32ET
Transistor (sourcing)CP1W-32ET1
I/O Units 
1916_lu_7_2
128RelayCP1W-20EDR1U, C, N, 
L, CE, 
KC
Transistor (sinking)CP1W-20EDT
Transistor (sourcing)CP1W-20EDT1
2416RelayCP1W-40EDRN, L, 
CE, KC
Transistor (sinking)CP1W-40EDT
Transistor (sourcing)CP1W-40EDT1
Analog 
Input Unit 
1916_lu_7_3
4CH--Input range: 
0 to 5 V, 1 to 5 V, 0 to 10 V, ±10 V, 
0 to 20 mA, or 4 to 20 mA.
Resolution: 
1/6000
CP1W-AD041UC1, N, 
L, CE, 
KC
Resolution: 
1/12000
CP1W-AD042UC1, N, 
CE, KC
Analog 
Output Unit 
1916_lu_7_4
--2CHOutput range: 
1 to 5 V, 0 to 10 V, ±10 V, 0 to 20 mA, 
or 4 to 20 mA.
Resolution: 
1/6000
CP1W-DA021UC1, N, 
L, CE, 
KC
--4CHResolution: 
1/6000
CP1W-DA041
Resolution: 
1/12000
CP1W-DA042UC1, N, 
CE, KC
Analog 
I/O Unit 
1916_lu_7_5
4CH4CHInput range: 
0 to 5 V, 1 to 5 V, 0 to 10 V, ±10 V, 
0 to 20 mA, or 4 to 20 mA. 
Output range: 
1 to 5 V, 0 to 10 V, ±10 V, 0 to 20 mA, 
or 4 to 20 mA.
Resolution: 
1/12000
CP1W-MAD44UC1, N, 
CE, KC
4CH2CHResolution: 
1/12000
CP1W-MAD42
2CH1CHResolution: 
1/6000
CP1W-MAD11UC1, N, 
L, CE, 
KC
Temperature 
Sensor Unit 
1916_lu_7_6
2CH--Sensor type: Thermocouple (J or K)CP1W-TS001UC1, N, 
L, CE, 
KC
4CH--Sensor type: Thermocouple (J or K)CP1W-TS002
2CH--Sensor type: Platinum resistance thermometer 
(Pt100 or JPt100)
CP1W-TS101
4CH--Sensor type: Platinum resistance thermometer 
(Pt100 or JPt100)
CP1W-TS102
4CH--Sensor type: Thermocouple (J or K) 
2 channels can be used as analog input. 
Input range: 1 to 5 V, 0 to 10 V, 4-20 mA
Resolution: 
1/12000
CP1W-TS003UC1, N, 
CE, KC
12CH--Sensor type: Thermocouple (J or K)CP1W-TS004
CompoBus/S 
I/O Link Unit 
1916_lu_7_7
88CompoBus/S slaveCP1W-SRT21UC1, N, 
L, CE, 
KC
Note: CP1L (L Type) CPU Units with 10 points do not support Expansion Units.

I/O Connecting Cable

NameSpecificationsModelStandards
I/O Connecting Cable80 cm (for CP1W/CPM1A Expansion Units)CP1W-CN811UC1, N, L, CE
Note: An I/O Connecting Cable (approx. 6 cm) for horizontal connection is provided with CP1W Expansion Units.

Optional Products, Maintenance Products and DIN Track Accessories

NameSpecificationsModelStandards
Battery SetFor CPU Units (Use batteries within two years of manufacture.)CJ1W-BAT01---
DIN TrackLength: 0.5 m; Height: 7.3 mmPFP-50N
Length: 1 m; Height: 7.3 mmPFP-100N
Length: 1 m; Height: 16 mmPFP-100N2
End PlateA stopper to secure the Units on the DIN Track.PFP-M

Industrial Switching Hubs

Product 
name
Appear- 
ance
SpecificationsAccessoriesCurrent 
con- 
sump- 
tion 
(A)
ModelStand- 
ards
No. 
of 
ports
Failure 
de- 
tection
Industrial 
Switching 
Hubs
1916_lu_10_1Quality of Service (QoS): 
EtherNet/IP™ control 
data priority 
Failure detection: 
Broadcast storm and 
LSI error detection 
10/100BASE-TX, 
Auto-Negotiation
3NoPower supply 
connector
0.22W4S1-03BUC, CE, 
KC
1916_lu_10_25No0.22W4S1-05B
5YesPower supply 
connector 
Connector for 
informing error
0.22W4S1-05CCE, KC


HMI MITSUBISHI GT2510-VTBA


ConditionNew
Weight (kg)2.1
Our Part NumberGT2510VTBA
Height (mm)218
Width (mm)303
Depth (mm)52
BrandMitsubishi
Manufacturer RangeGOT
Manufacturer SeriesGOT 2000
Supply Voltage (AC)100-240 V
IP RatingIP67
IP Rating BackIP20
Display Colour65536
Display Resolution640 x 480
Display Size10.4"
Display TypeTFT
BacklightingYes
Internal Memory (Mb)80
Keyboard TypeTouch Screen
Screen AspectLandscape
Short DescriptionMitsubishi GT2510-VTBA 10.4 Vga TFT, 65k Colour Graphic Operator Terminal, 640x480 Pixel Touch Screen, With Ethernet, RS232 And RS422/485, Front And Rear USB (Host And Device) Connections, Plus Sd Memory Card Slot.

HMI MITSUBISHI GT2708-STBA


ConditionNew
Weight (kg)1.5
Our Part NumberGT2708STBA
Height (mm)194
Width (mm)241
Depth (mm)52
BrandMitsubishi
Manufacturer RangeGOT
Manufacturer SeriesGOT 2000
Supply Voltage (AC)100-240 V
IP RatingIP67
IP Rating BackIP20
Display Colour65536
Display Resolution800 x 600
Display Size8.4"
Display TypeTFT
BacklightingYes
Internal Memory (Mb)128
Keyboard TypeTouch Screen
Screen AspectLandscape
Short DescriptionMitsubishi GT2708-STBA 8.4 Svga TFT, 65k Colour Graphic Operator Terminal, 800x600 Pixel Touch Screen, With Ethernet, RS232 And RS422/485, Front And Rear USB (Host And Device) Connections, Plus Sd Memory Card Slot.

Jumat, 19 Oktober 2018

MITSUBISHI AJ65SBTB1-16T1



Configured Specifications

Number of Outputs16Representative StandardCE / UL
Leakage current when OFF(mA)0.1 mA or LessOutput answer time1.5ms
Terminal shapeScrew terminal blockMaximum Switching Voltage(V)DC12/24V
Thermal Protection/ Short Circuit Protection/ Protective Function/ Fuse/ Surge ProtectorNAType of unitTransistor Output (Sink)
External connection1-line typeI/O unit power supply current50 mA or Less
Rated load current (rated opening/closing current)0.5A--

OMRON XWT-ID16



Expansion Units

One Expansion Unit can be combined with one Digital I/O Slave Unit (CRT1-ID16(-1), CRT1-OD16(-1), CRT1-ROS16, or CRT1-ROF16).
The following Expansion Units are available. They can be combined in various ways for flexible I/O capacity expansion.
ModelI/O pointsInput capacityOutput capacity
XWT-ID088 DC inputs (NPN)80
XWT-ID08-18 DC inputs (PNP)80
XWT-OD088 transistor outputs (NPN)08
XWT-OD08-18 transistor outputs (PNP)08
XWT-ID1616 DC inputs (NPN)160
XWT-ID16-116 DC inputs (PNP)160
XWT-OD1616 transistor outputs (NPN)016
XWT-OD16-116 transistor outputs (PNP)016

Basic Performance Specifications

ItemSpecification
Communications power supply voltage14 to 26.4 VDC
I/O power supply voltage *120.4 to 26.4 VDC (24 VDC -15%/+10%)
Noise immunityConforms to IEC 61000-4-4, 2 kV (power line).
Vibration resistance10 to 60 Hz with double-amplitude of 0.7 mm, 60 to 150 Hz and 50 m/s2 in 
X, Y, and Z directions for 80 min each
Shock resistance150 m/s2 (3 times each in 6 directions on 3 axes)
Dielectric strength500 VAC (between isolated circuits)
Insulation resistance20 MΩ min. (between isolated circuits)
Ambient operating temperature-10 to 55°C
Ambient operating humidity25% to 85% (with no condensation)
Ambient operating atmosphereNo corrosive gases
Storage temperature-25 to 65°C
Storage humidity25% to 85% (with no condensation)
Terminal block screw tightening torque 
*2
M3 wiring screws: 0.5 Nm 
M3 mounting screws: 0.5 Nm
InstallationMounted on 35-mm DIN Track or Mounting Bracket, or secured with M4 
screws (depending on model)


Cable GT10-C30R2-6P



Condition        : New
Weight (kg)     : 0.18
Our Part Number   : GT10C30R2-6P
Brand                     : Mitsubishi
Manufacturer Range  : GOT
Cable Length (m)       : 3
Screen Aspect            : Landscape
Type                           : Cable
Short Description       : Mitsubishi GT10-C30R2-6P GT1020/30 To Systemq Cpu Co mms Cable RS232, 3m, Mini-Din 6-Pin Plug

Cable GT10-C30R4-8P


Configured Specifications

Type-Compatible ModelGT1020 / GT1030
Handy GOT details-Connection destination-
Cable Length(m)3Connection destination other company name-
Connection destination-Specifications-
Connector 1MINI-DIN 8 pinConnector 2Discrete Wire
Communication MethodRS-422Note-


Cabel GT15-QC30B

Condition                     : New
Weight                          :(kg)0.665
Our Part Number         : GT15QC30B
Brand                           : Mitsubishi
Manufacturer Range   : GOT
Manufacturer Series    : GOT 1000
Cable Length  (m)       : 3
Screen Aspect              : Landscape
Type                             : Cable
Short Description       : Mitsubishi GT15-QC30B Connection Cable For Q-Bus Between GT1000 And 2000 Melsec System Q, 3m

Cabel GT15-A1SC50B


Product Specifications

SKUIN.HU.384879
TypeHMI Accessories
Sub TypeBus Connection Cable
Applicable ModelGT16, GT15, GT11
Cable Length5 m
FeaturesSmall CPU Extension Cable
ApplicationsFor connecting QNas/ansCPU &GOT (GT15-&GT11)-5M. For connection between QnAS/AnSCPU and GOT
Model NoGT15-A1SC50B