CS Seri Ethernet unit CS1W-EIP21




International Standards

  • The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
  • Contact your OMRON representative for further details and applicable conditions for these standards.

EtherNet/IP Unit


Unit typeProduct nameSpecificationsNo. of unit numbers allocatedCurrent consump- tion (A)ModelStand- ards
Communi- cations cableCommuni- cations functionsUnits per CPU Unit5 V sys- tem24 V sys- tem
CS1 CPU Bus UnitEtherNet/IP Unit1994_lu_1_1Shielded twisted-
pair (STP) cable
Categories:
100 Ω at 5, 5e
Tag Data Link
Functions,
Message
Communications
Functions
8
max.
10.41---CS1W-EIP21UC1,
N, L,
CE

Industrial Switching Hubs

Product 
name
AppearanceSpecificationsAccessoriesCurrent 
consump- 
tion (A)
ModelStand- 
ards
FunctionsNo. 
of 
pors
Failure 
detec- 
tion
Industrial 
Switching 
Hubs
1994_lu_2_1Quality of Service 
(QoS): EtherNet/IP 
control data priority 
Failure detection: 
Broadcast storm and 
LSI error detection 
10/100BASE-TX, 
Auto-Negotiation
3NoPower supply 
connector
0.22W4S1-03BUC, CE
1994_lu_2_25No0.22W4S1-05B
5YesPower supply 
connector 
Connector 
for informing 
error
0.22W4S1-05CCE

EtherNet/IP Unit Specifications

ItemSpecifications
Model numberCS1W-EIP21
Type100Base-TX (See note.)
Applicable PLCsCS-series PLCs
Unit classificationCS-series CPU Bus Unit
Mounting locationCPU Rack or Expansion Rack
Number of Units that can be mounted8 max. (including Expansion Racks)
CPU Unit
words used
Allocated CIO Area
words (CPU Bus Unit
words)
25 words/Unit (one unit number's words)
These words contain control bits and flags, the target node PLC's operating and error
information, Unit status, communications status, registered/normal target node information,
and FINS/TCP connection status.
Allocated DM Area
words (CPU Bus Unit
words)
100 words/Unit (one unit number's words)
These words contain the IP address display/setting area
User-set areaAny usable data area words
Target node PLC's operating and error information, and registered/normal target node
information
CPU Bus Unit System
Setup
Not used.
Non-volatile memory within
EtherNet/IP Unit (See note.)
The following settings are stored in the EtherNet/IP Unit's non-volatile memory.
Note: Unlike the regular Ethernet Units, the CPU Bus Unit Setup Area in the CPU Unit is not
used for these settings.
1. Unit setup (communications settings for the EtherNet/IP Unit, such as the IP address, DNS
server settings, host name, baud rate, FINS/UDP settings, and FINS/TCP settings)
2. Tag data link settings (device parameters)
Transfer
specifications
Media access methodCSMA/CD
Modulation methodBaseband
Transmission pathsStar form
Baud rate100 Mbit/s (100Base-TX)
Transmission mediaShielded twisted-pair (STP) cable
Categories: 100 Ω at 5, 5e
Transmission distance100 m (distance between hub and node)
Number of cascade
connections
There is no limitation when a switching hub is used.
Current consumption (Unit)410 mA max. at 5 V DC
Weight171 g max.
Dimensions35 × 130 × 101 mm (W × H × D)
Other general specificationsOther specifications conform to the general specifications of the CS-series
Note: If tag data links are being used, use 100Base-TX. Otherwise, 10Base-T can be used, but this is not recommended.

Communications Specifications

ItemSpecifications
CIP 
service
Tag data 
links 
(Cyclic 
communi- 
cations)
Number of connections256
Packet interval 
(refresh cycle)
0.5 to 10,000 ms (in 0.5-ms units) 
Can be set independently for each connection. 
(Data is refreshed over the network at the preset interval and 
does not depend on the number of nodes.)
Maximum allowed 
communications 
bandwidth per Unit
6,000 to 12,000 pps *1 *2
Number of tag sets256
Tag typesCIO Area, DM Area, EM Area, Holding Area, and Work Area
Number of tags per 
connection (= 1 tag set)
8 (7 tags when the tag set contains the PLC status)
Maximum link data size 
per node
184,832 words
Maximum data size per 
connection
252 words or 722 words *3 
Note: Data synchronicity is maintained within each connection.
Number of registrable 
tag sets
256 
(1 connection = 1 tag set)
Maximum size of 1 tag 
set
722 words 
(The PLC status uses 1 word when the tag set contains the PLC 
status.)
Maximum number of 
tags that can be 
refreshed per CPU Unit 
cycle *4
Output/Transmission (CPU to EtherNet/IP): 19 
Input/Reception (EtherNet/IP to CPU): 20 *5
Data that can be 
refreshed per CPU Unit 
cycle *4
Output/Transmission (CPU to EtherNet/IP): 7,405 words 
Input/Reception (EtherNet/IP to CPU): 7,405 words
Changing tag data link 
parameters during 
operation
Supported *6
Multicast packet filter 
function *7
Supported
Explicit 
messaging
Class 3 (connected)Number of connections: 128
UCMM (unconnected)Number of clients that can communicate at one time: 32 max. 
Number of servers that can communicate at one time: 32 max.
CIP routingCS1W-EIP21, CJ1W-EIP21, CJ2H-CPU6[]-EIP, CJ2M-CPU3[]
FINS serviceFINS/UDPSupported
FINS/TCP16 connections max.
EtherNet/IP conformance testConforms to A5
Ethernet interface10BASE-T or 100BASE-TX 
Auto Negotiation or fixed settings
*1. In this case, pps means "packets per second" and indicates the number of packets that can be processed in one 
       second. 
*2. To use 505 to 1,444 bytes as the data size, the system must support the Large Forward Open standard (an optional 
       CIP specification). The CS/CJ-series Units support this standard, but before connecting to nodes of other companies, 
       confirm that those devices also support it. 
*3. If the maximum data size is exceeded, the data refreshing with the CPU Unit will extend over two or more cycles. 
*4. If status layout is selected in the user settings, the maximum number of tags that can be received is 19 tags. 
*5. If parameters are changed in the EtherNet/IP Unit, however, the EtherNet/IP Unit will be restarted. When other nodes 
       are communicating with the affected node, the communications will temporarily time out and automatically recover 
       later. 
*6. Because the EtherNet/IP Unit is equipped with an IGMP client, unnecessary multicast packets can be filtered by using 
       a switching hub that supports IGMP snooping. 
*7. The EtherNet/IP Unit uses the TCP/UDP port numbers shown in the following table.
ServiceProtocolPort numberRemarks
Tag data linksUDP2222Fixed value
Class 3, UCMMTCP/UDP44818
DNSUDP53
FINS/UDP serviceUDP9600
Port numbers in the Unit Setup can be changed with
the CX-Programmer.
FINS/TCP serviceTCP9600
FTPTCP20, 21
SNTPUDP123
SNMPUDP161
SNMP trapUDP162

Network Configurator Requirements

The Network Configurator Ver. 3.0 or higher is a software package designed for building, setting, and controlling a multi-vendor EtherNet/IP Network using OMRON's EtherNet/IP. It is included in CX-One. The Network Configurator provides the following functions for building, setting, and controlling EtherNet/IP.


ItemSpecification
Operating environmentCXONE-AL[][]D-V[]
Network connection methodCS1/CJ1CJ2
Serial interfaceCPU Unit's Peripheral or RS-232C portCPU Unit's USB or RS-232C port
Ethernet interfaceEtherNet/IP Unit's Ethernet portCPU Unit's Ethernet port
EtherNet/IP Unit's Ethernet port
Location on NetworkA single node address is used (only when directly connected to EtherNet/IP).
Number of Units that can be connected to NetworkA single Network Configurator per Network
(More than one Configurator cannot be used in the same system.)
Main functionsNetwork control functionsThe Network configuration can be created and edited regardless of whether the
Network Configurator is online or offline.
The Network configuration can be read from a file or the network.
Configuration functionsThe EDS files used by the Network Configurator can be installed and deleted.
Supported file formatsConfigurator network configuration files (*.ncf)
Configuration files (*.ncf) created using the Network Configurator for EtherNet/IP
(version 2) can be imported by selecting External Data - Import from the File Menu.

CS1W-EIP21

CS1W-EIP21 Dimensions 1

Jumat, 24 Agustus 2018

MINAS A6V servo drives (24/48V DC)


Overview

Low voltage, high performance now also available for 24 or 48V DC input voltage. Panasonic expands the MINAS A6 servo drive series with the MINAS A6V.
Energy efficiency, long lifetime, power density, surge resistance: Panasonic has transferred the advantages of permanent magnet servo motors into the world of low voltage networks.
Battery-driven DC drives are very common in drive technology for applications where there is no AC or three-phase current network available. In most cases, the motors can be adapted to the special voltages. Especially in the area of drive technology for vehicles and the medical field there is a need for motors with battery voltages. These motors round off Panasonic’s portfolio of drive technology products.

Applications

  • Medical field, laboratory
  • Robotics
  • Autonomous vehicles (in the household and warehouse, lawn mower etc.)

Types

MINAS A6VOutputVoltageType
Driver200W/400W24V DCMVDLN5CSF
48V DCMVDLN5BSF
Motor200W24V DCMSMD02CL1S
MSMD02CL1T
48V DCMSMD02BL1S
MSMD02BL1T
400WMSMD04BL1S
MSMD04BL1T

Model codes

DriverMVDLN5_SF
24V DCC
48V DCB

MotorMSMD0_ _L1_
200W2_ _
400W4_ _
24V DC_C_
48V DC_B_
Without holding brake_ _S
With holding brake_ _T