CS Seri CJ2H-CPU64-EIP (Built in Ethernet)



General Specifications

ItemCJ2H-
CPU64-EIPCPU65-EIPCPU66-EIPCPU67-EIPCPU68-EIP
EnclosureMounted in a panel
GroundingLess than 100 Ω
CPU Rack Dimensions90 mm × 65 mm × 80 mm (H × D × W)
Weight *280 g or less
Current Consumption5 VDC, 0.82 A
Use 
Envi- 
ronment
Ambient Operating 
Temperature
0 to 55 °C
Ambient Operating 
Humidity
10% to 90% (with no condensation)
AtmosphereMust be free from corrosive gases.
Ambient Storage 
Temperature
- 20 to 70 °C (excluding battery)
Altitude2,000 m or less
Pollution Degree2 or less: Conforms to JIS B3502 and IEC 61131-2.
Noise Immunity2 kV on power supply line (Conforms to IEC 61000-4-4.)
Overvoltage CategoryCategory II: Conforms to JIS B3502 and IEC 61131-2.
EMC Immunity LevelZone B
Vibration ResistanceConforms to IEC60068-2-6.
5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz
Acceleration of 9.8 m/s2 for 100 min in X, Y, and Z directions (10 sweeps of 10
min each = 100 min total)
Shock ResistanceConforms to IEC60068-2-27.
147 m/s2, 3 times in X, Y, and Z directions (100 m/s2 for Relay Output Units)
BatteryLife5 years at 25 °C
WeightApprox. 10 g
ModelCJ1W-BAT01
Applicable StandardsConforms to cULus, NK, LR and EC Directives.
* Includes wight of end covers and battery.

Performance Specifications

ItemsCJ2H-
CPU64-EIPCPU65-EIPCPU66-EIPCPU67-EIPCPU68-EIP
User Memory50K steps100K steps150K steps250K steps400K steps
I/O Bits2,560 bits
Processing
Speed
Overhead Processing TimeNormal Mode: 200 μs
(If tag data links are used with EtherNet/IP, add the following to the above time: 100 μs + Number of transferred words × (0.33 μs or 0.87 μs *))
When High-speed interrupt function is used
Execution TimeBasic Instructions: 0.016 μs min.;
Special Instructions: 0.048 μs min.
Inter- 
rupts
I/O Interrupts and External 
Interrupts
Interrupt task startup time: 26 μs or 17 μs * (30 μs in unit Ver.1.0)
Return time to cyclic task: 11 μs or 8 μs * (15 μs in unit Ver.1.0)
* When High-speed interrupt function is used
Scheduled InterruptsInterrupt task startup time: 22 μs or 13μs * (27 μs in unit Ver.1.0)
Return time to cyclic task: 11 μs or 8μs * (15 μs in unit Ver.1.0)
* When High-speed interrupt function is used
Maximum Number of Connectable UnitsTotal per CPU Rack or Expansion Rack: 10 Units max.;
Total per PLC: 40 Units max.
Maximum Number of Expansion Racks3 max.
CIO AreaI/O Area2,560 bits (160 words): Words CIO 0000 to CIO 0159
Link Area3,200 bits (200 words): Words CIO 1000 to CIO 1199
Synchronous Data Refresh Area1,536 bits (96 words): Words CIO 1200 to CIO 1295
CPU Bus Unit Area6,400 bits (400 words): Words CIO 1500 to CIO 1899
Special I/O Unit Area15,360 bits (960 words): Words CIO 2000 to CIO 2959
DeviceNet Area9,600 bits (600 words): Words CIO 3200 to CIO 3799
Internal I/O Area3,200 bits (200 words): Words CIO 1300 to CIO 1499
37,504 bits (2,344 words): Words CIO 3800 to CIO 6143
Cannot be used for external I/O.
Work Area8,192 bits (512 words): Words W000 to W511
Cannot be used for external I/O.
Holding Area8,192 bits (512 words): Words H000 to H511
Bits in this area maintain their ON/OFF status when PLC is turned OFF or operating mode is changed.
Words H512 to H1535: These words can be used only for function blocks. They can be used only for function block instances (i.e., they are allocated only for internal variables in function blocks).
Auxiliary AreaRead-only: 31,744 bits (1,984 words)
7,168 bits (448 words): Words A0 to A447
24,576 bits (1,536 words): Words A10000 to A11535 *
Read/write: 16,384 bits (1,024 words) in words A448 to A1471 *
*A960 to A1471 and A10000 to A11535 cannot be accessed by CPU Bus Units, Special I/O Units, PTs, and Support Software that do not specifically support the CJ2 CPU Units.
Temporary Area16 bits: TR0 to TR15
Timer Area4,096 timer numbers (T0000 to T4095 (separate from counters))
Counter Area4,096 counter numbers (C0000 to C4095 (separate from timers))
DM Area32k words *
DM Area words for Special I/O Units: D20000 to D29599 (100 words × 96 Units)
DM Area words for CPU Bus Units: D30000 to D31599 (100 words × 16 Units)
*Bits in the EM Area can be addressed either by bit or by word. These bits cannot be addressed by CPU Bus Units, Special I/O Units, PTs, and Support Software that do not specifically support the CJ2 CPU Units.
EM Area32k words/bank × 25 banks max.: E00_00000 to E18_32767 max. *1 *2
*1. Bits in the EM Area can be addressed either by bit or by word. These bits cannot be addressed by CPU Bus Units, Special I/O Units, PTs, and Support Software that do not specifically support the CJ2 CPU Units.
*2. EM banks D to 18 cannot be accessed by CPU Bus Units, Special I/O Units, PTs, and Support Software that do not specifically support the CJ2 CPU Units.
*3. Force-set/reset to the EM Area is enabled by specifying a start bank in parameter settings. (unit version 1.2 or higher)
32K words
× 4 banks
32K words
× 4 banks
32K words
× 10 banks
32K words
× 15 banks
32K words
× 25 banks
Force- 
S/R 
Enabled
Banks
When EM force-S/R function is
used *3
Bank 0 to 3Bank 0 to 3Bank 0 to 9Bank 0 to EBank 0 to 18
When automatic address 
allocation is specified
Bank 3Bank 3Bank 6 to 9Bank 7 to EBank 11 to 18
Index RegistersIR0 to IR15
These are special registers for storing PLC memory addresses for indirect addressing. (Index Registers can be set so that they are unique in each task or so that they are shared by all tasks.)
Cyclic Task Flag Area128 flags
Memory Card128 MB, 256 MB, or 512 MB
Operating ModesPROGRAM Mode: Programs are not executed. Preparations can be executed prior to program execution in this mode.
MONITOR Mode: Programs are executed, and some operations, such as online editing, and changes to present values in I/O memory, are enabled in this mode.
RUN Mode: Programs are executed. This is the normal operating mode.
Execution ModeNormal Mode
Programming LanguagesLadder Logic (LD),
Sequential Function Charts (SFC),
Structured Text (ST), and
Instruction Lists (IL)
Function 
Blocks
Maximum number of definitions2,048
Maximum number of instances2,048
TasksType of TasksCyclic tasks
Interrupt tasks (Power OFF interrupt tasks, scheduled interrupt tasks, I/O interrupt tasks, and external interrupt tasks)
Number of TasksCyclic tasks: 128
Interrupt tasks: 256
(Interrupt tasks can be defined as cyclic tasks to create extra cyclic tasks. Therefore, the total number of cyclic tasks is actually 384 max.)
Symbols 
(Variables)
Type of SymbolsLocal symbols: Can be used only within a single task in the PLC.
Global symbols: Can be used in all tasks in the PLC.
Network symbols (tags): I/O memory in the CPU Unit can be externally accessed using symbols, depending on parameter settings.
Data Type of SymbolsBOOL (bit)
UINT (one-word unsigned binary)
UDINT (two-word unsigned binary)
ULINT (four-word unsigned binary)
INT (one-word signed binary)
DINT (two-word signed binary)
LINT (four-word signed binary)
UINT BCD (one-word unsigned BCD) *1
UDINT BCD (two-word unsigned BCD) *1
ULINT BCD (four-word unsigned BCD) *1
REAL (two-word floating-point)
LREAL (four-word floating-point)
CHANNEL (word) *1
NUMBER (constant or number) *1
WORD (one-word hexadecimal)
DWORD (two-word hexadecimal)
LWORD (four-word hexadecimal)
STRING (1 to 255 ASCII characters)
TIMER (timer) *2
COUNTER (counter) *2
User defined data types (data structures) *3
*1. Cannot be used in Function blocks
*2. Can be used only in Function blocks
*3. Supported only when CX-Programmer version 9.0 or later is used
Maximum Size of Symbol32k words
Array Symbols (Array Variables)One-dimensional arrays
Number of Array Elements32,000 elements max.
Number of Registrable Network 
Symbols (Tags)
20,000 max.
Length of Network Symbol (Tag) Name255 bytes max.
Encoding of Network Symbols (Tags)UTF-8
Data 
Tracing
Memory Capacity8,000 words16,000 words32,000 words
(The EM Area can be specified from the CX-Programmer to use up to 32K words multiplied by the number of banks supported by the CPU Unit model.)
Number of SamplingsBits = 31, one-word data =16, two-word data = 8, four-word data = 4
Sampling Cycle1 to 2,550 ms (Unit: 1 ms)
Trigger ConditionsON/OFF of specified bit
Data comparison of specified word
Data size: 1 word, 2 words, 4 words
Comparison Method: Equals (=), Greater Than (>), Greater Than or Equals (≥), Less Than (<), Less Than or Equals (≤), Not Equal (≠)
Delay Value- 32,768 to +32,767 ms
File MemoryMemory Card (128, 256, or 512 Mbytes) (Use the Memory Cards provided by OMRON.)
EM file memory (Part of the EM Area can be converted for use as file memory.)
Source/ 
Comment 
Memory
Program sources, comments, 
program indexes, symbol tables
Capacity: 3.5 Mbytes
Communi- 
cations
Logical Ports for 
Communications
Logical Ports8 ports (Used for SEND, RECV, CMND, PMCR, TXDU, and RXDU instructions.)
Extended 
Logical Ports
64 ports (Used for SEND2, RECV2, CMND2, and PMCR2 instructions.)
CIP 
Communications 
Specification
Class 3 
(Connection Type)
Number of connections: 64
UCMM (Non- 
connection Type)
Maximum number of clients that can communicate at the same time: 32
Maximum number of servers that can communicate at the same time: 40
Peripheral (USB) PortUSB 2.0-compliant B-type connector
Baud Rate12 Mbps max.
Transmission Distance5 m max.
Serial PortInterface: Conforms to EIA RS-232C.
Communications MethodHalf-duplex
Synchronization MethodStart-stop
Baud Rate0.3, 0.6, 1.2, 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, or 115.2 (kbps)
Transmission Distance15 m max.
EtherNet/IP Port---
Transmis-
sion 
Specifica-
tions
Media Access 
Method
CSMA/CD
ModulationBaseband
Transmission 
Paths
Star
Baud Rate100 Mbps (100Base-TX)
Transmission 
Media
Shielded twisted-pair (STP) cable; Categories: 5, 5e
Transmission 
Distance
100 m (between hub and node)
Number of Cascade 
Connections
No restrictions if switching hub is used.
Communi-
cations 
Specifica-
tions
CIP 
Communications: 
Tag Data Links
---
Number of 
Connections
256
Packet Interval 
(Refresh period)
0.5 to 10,000 ms (Unit: 0.5 ms)
Can be set for each connection. (Data will be refreshed at the set interval, regardless of the number of nodes.)
Maximum allowed 
communications
bandwidth per Unit
6,000 to 12,000 pps *1 *2
Number of 
Registerable Tag
256
Type of TagsCIO, DM, EM, HR, WR, and Network symboles
Number of Tags 
per Connection
8 (Seven tags if PLC status is included in the segment.)
Maximum Link 
Data Size per 
Node
184,832 words
Maximum Data 
Size per 
Connection
252 or 722 words *3
(Data is synchronized within each connection.)
Number of 
Registrable Tag 
Set
256 (1 connection = 1 segment)
Maximum Tag 
Set Size
722 words (One word is used when PLC status is included in the segment.)
Maximum 
Number of Tags 
Refreshable in a
Single Cycle of 
CPU Unit *4
Output/send (CPU Unit to EtherNet/IP): 256
Input/receive (EtherNet/IP to CPU Unit): 256
Data Size 
Refreshable in a
Single Cycle of 
CPU Unit *4
Output/send (CPU to EtherNet/IP): 6,432 words
Input/receive (EtherNet/IP to CPU): 6,432 words
Change of Tag 
Data Link 
Parameter 
Settings during 
Operation
OK *5
Multi-cast Packet 
Filter *6
OK
CIP 
Communications: 
Explicit Messages
---
Class 3 
(Connection Type)
Number of connections: 128
UCMM (Non- 
connection Type)
Maximum number of clients that can communicate at the same time: 32
Maximum number of servers that can communicate at the same time: 32
CIP RoutingOK (CIP routing is enabled for the following remote Units: CJ1W-EIP21, CJ2H-CPU6[]-EIP, CJ2M-CPU3[], and CS1W-EIP21.)
FINS 
Communications
---
FINS/UDPOK
FINS/TCP16 connections max.
EtherNet/IP 
Conformance Test
Conforms to A5.
EtherNet/IP 
Interface
10Base-T/100Base-TX
Auto Negotiation/Fixed Setting

CJ2H CPU Unit
CJ2H-CPU6[]-EIP

CJ2H-CPU6[]-EIP Dimensions 2 CJ2H-CPU6[]-EIP_Dim

CS Seri Ethernet unit CJ1W-EIP21



EtherNet/IP Units Specifications

ItemSpecifications
Model numberCJ1W-EIP21
Type100Base-TX *1
Applicable PLCsNJ-series, CJ (CJ1, CJ2) series, CP1H, and NSJ series PLCs.
Unit classificationCJ-series CPU Bus Unit
Mounting locationCPU Rack or Expansion Rack
Number of Units that can be 
mounted
NJ-series System: 4 max. (including Expansion Racks) 
CJ series System and NSJ series System: 8 max. (including Expansion Racks) *2 
CP1H System: 2 max.
CPU 
Unit 
words 
used
Allocated CIO Area 
words (CPU Bus 
Unit words)
25 words/Unit (one unit number's words)
These words contain control bits and flags, the target node PLC's operating and error 
information, Unit status, communications status, registered/normal target node 
information, and FINS/TCP connection status.
Allocated DM Area 
words (CPU Bus 
Unit words)
100 words/Unit (one unit number's words)
These words contain the IP address display/setting area.
User-set areaAny usable data area words
Target node PLC's operating and error information, and registered/normal target 
node information
CPU Bus Unit 
System Setup
Not used.
Non-volatile memory within 
EtherNet/IP Unit 
(See note.)
The following settings are stored in the EtherNet/IP Unit's non-volatile memory. 
Note: Unlike the regular Ethernet Units, the CPU Bus Unit Setup Area in the CPU 
Unit is not used for these settings. 
1. Unit Setup (communications settings for the EtherNet/IP Unit, such as the IP 
address, DNS server settings, host name, baud rate, FINS/UDP settings, and FINS/ 
TCP settings) 
2. Tag data link settings (device parameters)
Transfer 
specifi- 
cations
Media access 
method
CSMA/CD
Modulation methodBaseband
Transmission pathsStar form
Baud rate100 Mbit/s (100Base-TX)
Transmission mediaShielded twisted-pair (STP) cable 
Categories: 100 Ω at 5, 5e
Transmission 
distance
100 m (distance between hub and node)
Number of cascade 
connections
There is no limitation when a switching hub is used.
Current consumption (Unit)410 mA max. at 5 V DC
Weight94 g max.
Dimensions31 × 90 × 65 mm (W × H × D)
Other general specificationsOther specifications conform to the general specifications of the CJ-series.
*1. If tag data links are being used, use 100Base-TX. Otherwise, 10Base-T can be used, but this is not recommended. 
*2. Up to seven EtherNet/IP Units can be connected to a CJ2H-CPU6[]-EIP. Up to two EtherNet/IP Units can be connected 
       to a CJ2M CPU Unit.

Communications Specifications

ItemSpecifications
NJCJ2CJ1
CIP 
service
Tag data 
links 
(Cyclic 
communi- 
cations)
Number of connections256
Packet interval 
(refresh cycle)
0.5 to 10,000 ms (in 0.5-ms units) 
Can be set independently for each connection. 
(Data is refreshed over the network at the preset interval and 
does not depend on the number of nodes.)
Maximum allowed 
communications 
bandwidth per Unit
6,000 to 12,000 pps *1 *2
Number of tag sets256
Tag typesCIO Area, DM Area, EM Area, Holding Area, Work Area, and 
network symbols *3
Number of tags per 
connection (= 1 tag set)
8 (7 tags when the tag set contains the controller status)
Maximum link data size 
per node
184,832 words
Maximum data size per 
connection *4
504 bytes (252 words) or 1444 bytes (722 words) *3 
Data synchronicity is maintained within each connection.
Number of registrable 
tag sets
256 (1 connection = 1 tag set)
Maximum size of 1 tag 
set
722 words 
(The controller status uses 1 word when the tag set contains the 
PLC status.)
Maximum number of tags 
that can be refreshed 
per CPU Unit cycle *5
Output/Transmission 
(CPU to EtherNet/IP): 
256 
Input/Reception 
(EtherNet/IP to CPU): 
256
Output/Transmission (CPU to 
EtherNet/IP): 19 
Input/Reception (EtherNet/IP to CPU): 
20 *6
Data that can be 
refreshed per CPU Unit 
cycle *5
Output/Transmission 
(CPU to EtherNet/IP): 
6,432 words 
Input/Reception 
(EtherNet/IP to CPU): 
6,432 words
Output/Transmission (CPU to 
EtherNet/IP): 7,405 words 
Input/Reception (EtherNet/IP to CPU): 
7,405 words
Changing tag data link 
parameters during 
operation
Supported *7
Multicast packet filter 
function *8
Supported
Explicit 
messaging 
*9
Class 3 (connected)Number of connections: 128
UCMM (unconnected)Number of clients that can communicate at one time: 32 max. 
Number of servers that can communicate at one time: 32 max.
CIP routing *10Supported 
CJ1W-EIP21, CS1W-EIP21, NJ-501-[][][][], NJ-301-[][][][], 
CJ2H-CPU[][]-EIP, CJ2M-CPU3[]
FINS serviceFINS/UDPNot supportedSupported
FINS/TCPNot supported16 connections max.
EtherNet/IP conformance testConforms to A8
Ethernet interface10BASE-T or 100BASE-TX 
Auto Negotiation or fixed settings
*1. In this case, pps means "packets per second" and indicates the number of packets that can be processed in one 
       second. 
*2. When using the EtherNet/IP Unit with version 3.0 or later. When using the EtherNet/IP Unit with version 
       2.1 or earlier, the maximum allowed communications bandwidth per Unit is 6,000 pps. When using the EtherNet/IP 
       Unit with version 3.0 or later, the Network Configurator with version 3.57 or higher is required. 
*3. Network symbols can be used only by the NJ501-[][][][], NJ301-[][][][], CJ2H-CPU6[]-EIP and CJ2M-CPU3[]. 
*4. To use 505 to 1,444 bytes as the data size, the system must support the Large Forward Open standard (an optional 
       CIP specification). The CS/CJ-series Units support this standard, but before connecting to nodes of other companies, 
       confirm that those devices also support it. 
*5. If the maximum data size is exceeded, the data refreshing with the CPU Unit will extend over two or more cycles. 
*6. If status layout is selected in the user settings, the maximum number of tags that can be received is 19 tags. 
*7. If parameters are changed in the EtherNet/IP Unit, however, the EtherNet/IP Unit will be restarted. When other nodes 
       are communicating with the affected node, the communications will temporarily time out and automatically recover 
       later. 
*8. Because the EtherNet/IP Unit is equipped with an IGMP client, unnecessary multicast packets can be filtered by using 
       a switching hub that supports IGMP snooping. 
*9. The EtherNet/IP Unit uses the TCP/UDP port numbers shown in the following table.
ServiceProtocolPort numberRemarks
CJ1/CJ2NJCJ1/CJ2NJCJ1/CJ2NJ
Used by system---UDP---2223, 2224Fixed value
Tag data linksUDP2222
Class3, UCMMTCP/UDP44818
DNSUDP53
BOOTP client---UDP---68
FINS/UDP serviceUDP---9600---Port numbers in the
Unit Setup can be
changed with the
CX-Programmer.
Port numbers in the
Unit Setup can be
changed with the
Sysmac Studio.
FINS/TCP serviceTCP---9600---
FTPTCP20, 2121
SNTPUDP123
SNMPUDP161
SNMP trapUDP162
*10.When NJ-Series CPU Units is described, Supported only by the EtherNet/IP Units with unit version 2.1 or later and 
       NJ-Series CPU Units with unit version 1.01 or later.

Unit Versions and Software Versions

The following versions of the Sysmac Studio, CX-Programmer and Network Configurator are required to set EtherNet/IP Units. 
Yes: Supported, ---: Not supported
CJ1W-EIP21Sysmac Studio *1CX-Programmer *2Network Configurator for EtherNet/IP
Ver.1.01 or 
lower
Ver.1.02 or 
higher
Ver.7.1 or 
lower
Ver.8.0 or 
higher
Ver.8.02 or 
higher
Ver.3.40 or lowerVer.3.50 or higher
Ver.1.0---------Yes *3YesYesYes
Ver.2.0---------YesYesYesYes
Ver.2.1---Yes---YesYes---Yes
Ver.3.0 *4---Yes---YesYes---Yes
*1. Available only when connecting with NJ-series CPU Units. 
*2. Available only when connecting with CJ1/CJ2-series CPU Units. 
*3. The most recent version of the common module for CX-One version 3.[][] must be installed. 
*4. Using the Sysmac Studio auto-update (November 2014 or later).

Network Configurator Requirements

The Network Configurator Ver. 3.0 or higher is a software package designed for building, setting, and controlling a multi-vendor EtherNet/IP Network using OMRON's EtherNet/IP. It is included in CX-One version 3.0. The Network Configurator provides the following functions for building, setting, and controlling EtherNet/IP.
ItemSpecification
Operating environmentRefer to the CX-One Setup Manual (Cat. No. W463). 
CXONE-AL[][]D-V[]
Network 
connection 
method
CS1/CJ1CJ2NJ
Serial interfaceCPU Unit's Peripheral or 
RS-232C port
CPU Unit's USB or RS-232C portCPU Unit's USB port
Ethernet 
interface
EtherNet/IP Unit's 
Ethernet port
CPU Unit's Ethernet port 
EtherNet/IP Unit's Ethernet port
Location on NetworkA single node address is used (only when directly connected to EtherNet/IP).
Number of Units that can be 
connected to Network
A single Network Configurator per Network 
(More than one Configurator cannot be used in the same system.)
Main 
functions
Network control 
functions
The Network configuration can be created and edited regardless of whether the 
Network Configurator is online or offline. 
The Network configuration can be read from a file or the network.
Configuration 
functions
The EDS files used by the Network Configurator can be installed and deleted.
Supported file formatsConfigurator network configuration files (*.ncf) 
Configuration files (*.ncf) created using the Network Configurator for EtherNet/IP 
(version 2) can be imported by selecting External Data - Import from the File Menu.

CJ1W-EIP21