Kontak Kami

KONTAK KAMI : Telpon : 02126071413 Hp/WhatsApp : 081212269831 Perwakilan Jakarta : Gedung LTC Glodok Lantai 1 Blok C30 No.31 Jl.Hayam Wuruk No.127 Jakarta , Indonesia

Senin, 22 Oktober 2018

OMON CJ1W-TC003



International Standards

  • The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
  • Contact your OMRON representative for further details and applicable conditions for these standards.
Unit
classi-
fica-
tion
Product
name
SpecificationsNo. of
unit
numbers
allocated
Current
consumption
(A)
ModelStand-
ards
No. of loopsTemperature
sensor inputs
Control outputs5 V24 V
CJ1
Special
I/O
Units
Temperature
Control
Units
4 loopsThermocouple
input
(R, S, K, J, T,
B, L)
Open collector NPN
outputs (pulses)
20.25-CJ1W-TC001 *UC1, N,
L, CE
4 loopsOpen collector PNP
outputs (pulses)
0.25-CJ1W-TC002 *
2 loops, heater
burnout detection
function
Open collector NPN
outputs (pulses)
0.25-CJ1W-TC003
2 loops, heater
burnout detection
function
Open collector PNP
outputs (pulses)
0.25-CJ1W-TC004
4 loopsPlatinum
resistance
thermometer
input
(JPt100, Pt100)
Open collector NPN
outputs (pulses)
0.25-CJ1W-TC101 *
4 loopsOpen collector PNP
outputs (pulses)
0.25-CJ1W-TC102 *
2 loops, heater
burnout detection
function
Open collector NPN
outputs (pulses)
0.25-CJ1W-TC103
2 loops, heater
burnout detection
function
Open collector PNP
outputs (pulses)
0.25-CJ1W-TC104

General Specifications

ItemSpecification
Unit classificationCJ-series Special I/O Unit
Compatible RacksCJ-series CPU Rack or CJ-series Expansion Rack
Max. number of
Units
10 Units/Rack max. (CPU Rack or Expansion Rack)
CPU Unit data
areas for data
storage/exchange
Special I/O Unit Area
(960 words)
CIO 2000 to CIO 2959
20 words/Unit for
constant data
exchange (6 output
words and 14
input words)
CPU Unit to
Temperature
Control Unit
Set point (SP)
Operating commands
RUN/STOP control
Start/Stop AT
Write commands
Heater burnout set value
Temperature
Control Unit
to CPU Unit
Process value (PV)
Set point (SP)
Status
Heater current monitor
DM words allocated to
Special I/O Units
(9,600 words)
D20000 to D29599
10 words/Unit
transferred when
power is turned ON or
Unit is restarted
CPU Unit to
Temperature
Control Unit
Alarm mode
Alarm hysteresis
90 words/Unit for regular
data exchange
Two-way
transfer
between CPU
Unit and
Temperature
Control Unit
Alarm value
Input compensation value
Control period
Hysteresis
Proportional band
Integral time
Derivative time
Output monitor
Insulation
resistance
20 M Ω min. (at 500 VDC) between the following points:
All output and NC terminals and external AC terminals (Power Supply Unit)
All input terminals and external AC terminals (Power Supply Unit)
All input terminals and all output terminals
All external DC terminals (inputs, outputs, and NC) and the FG plate
Between input terminals (sensor and CT inputs)
I/O terminals and NC terminals
Dielectric strength2,000 VAC 50/60 Hz for 1 min., detected current: 1 mA
The output terminals/NC terminals and external AC terminals (Power Supply Unit)
1,000 VAC 50/60 Hz for 1 min., detected current: 1 mA
Input terminals and external AC terminals (Power Supply Unit)
Input terminals and output terminals
External DC terminals (inputs, outputs, and NC) and the FG plate
500 VAC 50/60 Hz for 1 min., detected current: 1 mA
Between input terminals (sensor and CT inputs)
I/O terminals and NC terminals
Internal current
consumption
250 mA max., 5 VDC
OtherOther general specifications conform to the CJ-series general specifications.
Dimensions31 × 90 × 65 mm (W × H × D)
Weight150 g max.

Characteristics

ItemSpecification
Model numberCJ1W-TC00[]CJ1W-TC10[]
Temperature sensorThermocouple: R, S, K, J, T, L, BPlatinum resistance thermometer: Pt100, JPt100
Number of loops4 loops or 2 loops with heater burnout detection *1
Control output
and heater burnout
alarm output
NPN or PNP outputs, both with short-circuit protection *1
External power supply voltage: 24 VDC +10%, -15%
Max. switching capacity: 100 mA (per output)
Leakage current: 0.3 mA max.
Residual voltage: 3 V max.
Temperature
control method
ON/OFF control or PID control with two degrees of freedom (Set with pin 6 on the Unit's DIP switch.)
Control operationForward or reverse operation (Set with pins 4 and 5 on the Unit's DIP switch.)
RUN/STOP controlSupported (Controlled from the CPU Unit through bits allocated in the Special I/O Unit area.)
Operation with
CPU Unit in
PROGRAM mode
The Temperature Control Unit can be set to continue operating or stop operating when the CPU Unit is in PROGRAM mode. (Set with pin 1 on the Unit's DIP switch.)
Auto/Manual
switch for
operational output
None
Autotuning (AT)
of PID constant
Supported (Controlled from the CPU Unit through bits allocated in the Special I/O Unit area.)
Indication accuracyCelsius: ± 0.3% of PV or ± 1 ° C (whichever is larger) ± 1 digit max.
Fahrenheit: ± 0.3% of PV or ± 2 ° F (whichever is larger) ± 1 digit max.
L and - 100 ° C or less for K and T are ± 2 ° C ± 1 digit max.
200 ° C or less for R and S is ± 3 ° C ± 1 digit max.
No accuracy is specified for 400 ° C or less for B *2
Celsius: ± 0.3% of PV or ± 0.8 ° C (whichever is larger) ± 1 digit max.
Fahrenheit: ± 0.3% of PV or ± 1.6 ° F (whichever is larger) ± 1 digit max.
Hysteresis (when
using ON/OFF control)
0.0 to 999.9 ° C or ° F (0.1 ° C or ° F units)
Proportional band0.1 to 999.9 ° C or ° F (0.1 ° C or ° F units)
Integral (reset) time0 to 9,999 s (one-second units)
Derivative (rate) time0 to 9,999 s (one-second units)
Control period1 to 99 s (one-second units)
Sampling period500 ms (4 loops)
Output refresh period500 ms (4 loops)
Display refresh period500 ms (4 loops)
Input
compensation
value
- 99.9 to 999.9 ° C or ° F (0.1 ° C or ° F units)
Alarm output
setting range
- 999 to 9,999 ° C or ° F (1 ° C or ° F units)
The setting range will be - 99.9 to 999.9 ° C or ° F (0.1 ° C or ° F units) for K or J with decimal point mode, or platinum resistance thermometer.B24
External terminal
connections
Removable terminal block with 18 points (M3 screws)
Effect on the CPU
Unit's cycle time
0.4ms
*1. The last three digits of the model number indicate the Unit's features:
CJ1W-TC Specifications 3
*2. Indication accuracy of thermocouples 
       • Accuracy ratings are given for the Temperature Control Unit used in a set with a cold-junction compensator (on the 
           terminal block). Always use the Unit and terminal block in a set. There are labels with serial numbers attached to 
           the terminal blocks and Units to help keep track of the sets. 
       • When returning a thermocouple-type Temperature Control Unit for repair, always return the Unit and the terminal 
           block (with the cold-junction compensator) as a set.

Heater Burnout (HB) Alarm

ItemSpecification
Maximum heater currentSingle-phase AC, 50 A
Indication accuracy of input current±5% of full scale ± 1 digit max.
Heater burnout alarm setting range0.1 to 49.9 A (0.1 A units)
The heater burnout detection function will not operate if the set value is set to 0.0 A or 50.0 A.
(When the SV is 0.0 A, the heather burnout alarm will be OFF. When the SV is 50.0 A, the heater
burnout alarm will be ON.)
Min. detectable ON time *200 ms
* If the control output is ON for less than 200 ms, the heater burnout detection function will not operate and heater 
   current measurement will not be performed.

Current Transformer (CT) Ratings

ItemE54-CT1E54-CT3
Max. continuous heater current50A120 A *
Dielectric strength1,000 VAC (1 min.)
Vibration resistance50 Hz, 98 m/s2
WeightApprox. 11.5 gApprox. 50 g
AccessoriesNoneContacts (2)
Plugs (2)

CJ1W-TC[][][]

CJ1W-TC Dimensions 2 CJ1W-TC[][][]_Dim

Current Transformer (Optional)

E54-CT1

CJ1W-TC Dimensions 4 E54-CT1_Dim

E54-CT3

CJ1W-TC Dimensions 5 E54-CT3_Dim

OMRON SRT2-ID16


Brand: OMRON 
Name: Transistor Remote I/O Terminals
Model: SRT2-ID16
I/O classification: Input. 
Internal I/O circuit common: NPN (+ common). 
I/O points: 16. 
Rated voltage: 24 VDC. 
I/O rated voltage: 24 VDC. 
Long-distance Communications Supported by SRT2 Models, 
(Long-distance/High-speed Communications Selection). 
Ultra-compact at 80 x 48 x 50 (W x H x D) mm for, 
4-point and 8-point terminals and 105 x 48 x 50, 
(W x H x D) mm for 16-point terminals. 
Two independent power supplies can be used, 
because the I/O terminals are insulated from the internal circuits. 
DIN track mounting and screw mounting are both supported.


I/O classification: Output. 
Internal I/O circuit common: PNP (+ common). 
I/O points: 16. 
Rated voltage: 24 VDC. 
I/O rated voltage: 24 VDC. 
Long-distance Communications Supported by SRT2 Models, 
(Long-distance/High-speed Communications Selection). 
Ultra-compact at 80 x 48 x 50 (W x H x D) mm for, 
4-point and 8-point terminals and 105 x 48 x 50, 
(W x H x D) mm for 16-point terminals OMRON SRT2-ID16 SRT2-ID16 
Two independent power supplies can be used, 
because the I/O terminals are insulated from the internal circuits. 
DIN track mounting and screw mounting are both supported. 
Name: Compact Connectors. 
Specifications: Inputs; 2 inputs; NPN. 
Bit slave of smallest class in industry, 
Innovation in wiring for any type of machinery OMRON SRT2-ID16. 
Available in 2 types: 2-point Bit Slave Unit, 
and 4-point Bit Slave Unit. 
Compact size for installation in limited space. 
Save space and wiring since bit slave can be, 
installed near I/O devices. 
Industry first bit slave connectable with round, 
cables which can be easily purchased at a lower price. 
Connectable with flat cables, too for easy wiring. 
Cables are selectable depending on applications OMRON SRT2-ID16. Name: MIL Connectors. 
Specifications: Outputs; 32 outputs ; PNP; --. 
"Easy" and "Flexible" system expansion, 
with linked CC-Link and CompoNet. 
Branching is easily made with CompoNet. 
Wiring material cost can be reduced. 
Bit-level I/O distribution reduces, 
wiring in the system OMRON Transistor Remote I/O Terminals. 
A wide variety of CompoNet Slave Units, 
contribute to system size reduction. 
Seven-segment Display on the Gateway Unit, 
helps to detect errors on site OMRON Transistor Remote I/O Terminals. 
The Participation Flags and Communications, 
Error Flags can be checked at the Host, 
Controller to detect the location and, 
content of the error. Name: e-CON Connectors. 
Specifications: Outputs; 16 outputs; NPN; 
Without Short-circuit and, 
Disconnected Line Detection OMRON Transistor Remote I/O Terminals. 
"Easy" and "Flexible" system expansion, 
with linked CC-Link and CompoNet. 
Branching is easily made with CompoNet. 
Wiring material cosst can be reduced SRT2-ID16. 
Bit-level I/O distribution reduces, 
wiring in the system. 
A wide variety of CompoNet Slave Units, 
contribute to system size reduction. 
Seven-segment Display on the Gateway Unit, 
helps to detect errors on sitee OMRON SRT2-ID16. 
The Participation Flags and Communications, 
Error Flags can be checked at the Host, 
Controller to detect the location and, 
content of the error.

SRT2-ID16(-1)
SRT2-OD16(-1)
SRT2-ID / OD(-1) Dimensions 2



OMRON CJ1W-NC213



Basic Specifications

ItemModel
CJ1W-NC113/133CJ1W-NC213/233CJ1W-NC413/433
Power supply 
voltage
5 V DC (for the PCU itself)
24 V DC (external power supply)
5 V DC (external power supply; line driver output only)
Allowable power
supply voltage 
range
4.75 to 5.25 V DC (for the PCU itself)
21.6 to 26.4 V DC (external power supply)22.8 to 25.2 V DC 
(external power supply)
4.75 to 5.25 V DC (external power supply; line driver output only)
Internal current 
consumption
250 mA max. at 5 V DC250 mA max. at 5 V DC360 mA max. at 5 V DC
Current 
consumption of 
external power 
supply
NC113: 30 mA max. at 24 V DC
NC133: 10 mA max. at 24 V DC
NC133: 60 mA max. at 5 V DC
NC213: 50 mA max. at 24 V DC
NC233: 20 mA max. at 24 V DC
NC233: 120 mA max. at 5 V DC
NC413: 100 mA max. at 24 V DC
NC433: 30 mA max. at 24 V DC 
NC433: 230 mA max. at 5 V DC
External 
dimensions
90 (H) × 31 (W) × 65 (D) (all models)
Weight100 g max.100 g max.150 g max.
Ambient 
operating 
temperature
0 to 55 ° C0 to 50 ° C *
Note: Specifications not listed above conform to CJ Series general specifications. 
* Refer to Operation Manual 3-3-5 Mounting Precaution for CJ1W-NC413/NC433 for information on the ambient operating 
  temperature of the CJ1W-NC413/433.

Performance Specifications

ItemModel
CJ1W-NC113/133CJ1W-NC213/233CJ1W-NC413/433
Applicable PLC modelsCJ-series PLCs *1
Unit typeSpecial I/O Unit
I/O requirementsWords5 words10 words20 words
Controlled driverPulse-train input-type Servo Drive or stepping motor driver 
NC113/213/413 models have open collector output. 
NC133/233/433 models have line driver output.
ControlControl systemOpen-loop control by pulse train output
Number of control 
axes
1 axis2 axes4 axes
Control unitPulse
Positioning operationsTwo types: memory operation and direct operation
Positioning 
operations
Independent1 axis2 independent axes4 independent axes
Linear interpolationNone2 axes max.4 axes max.
Speed control1 axis2 independent axes4 independent axes
Interrupt feeding1 axis2 independent axes4 independent axes
PositionsRange-1,073,741,823 to 1,073,741,823 pulses *2
Data items100/axis
SpeedsRange1 pps to 500 kpps
Data items100/axis
Acceleration and 
deceleration times
Range0 to 250 s, until maximum speed is reached.
Data items9/axis for acceleration and deceleration each
Functions and 
settings
Origin searchOrigin proximity input signal: selectable (absent, N.O. or N.C. contact). 
Origin input signal: selectable (N.O. or N.C. contact) 
Origin compensation: -1,073,741,823 to 1,073,741,823 pulses 
Origin search speed: High-speed or proximity-speed can be set. 
Origin detection method: May be set to stop upon origin input signal after proximity input 
signal has turned ON, to stop upon origin input signal after proximity input signal has 
turned OFF, to stop upon origin input signal without using proximity input signal, or to stop 
upon origin input signal after limit input signal has turned OFF. 
N.O. = Normally open 
N.C. = Normally closed
JoggingJogging can be executed at a specified speed.
Dwell times19/axis can be set from 0 to 9.99 s (unit: 0.01 s).
Acceleration/ 
deceleration curves
Trapezoidal or S-curve (Can be set separately for each axis.)
ZonesZone Flag turns ON when present position is within a specified zone. Three zones can be 
set for each axis.
Software limitsCan be set within a range of -1,073,741,823 to 1,073,741,823 pulses.
Backlash 
compensation
0 to 9,999 pulses. Compensation speed can also be set.
TeachingWith a command from the PLC, the present position can be taken as the position data.
Deceleration stopThe STOP command causes positioning to decelerate to a stop according to the specified 
deceleration time.
Emergency stopPulse outputs are stopped by an external emergency stop command.
Present position 
preset
The PRESENT POSITION PRESET command can be used to change the present position 
to a specified value.
OverrideWhen the override enabling command is executed during positioning, the target speed is 
changed by applying the override coefficient. Possible to set to a value from 1 to 999% (by 
an increment of 1%)
Data saving1) Saving to flash memory. (Can be written 100,000 times.) 
2) Reading from PLC area by data reading instruction. 
3) Reading by Support Software and saving to personal computer hard disk or floppy disk.
External I/OInputsPrepare the following inputs for each axis: 
CW and CCW limit input signals, origin proximity input signal, origin input signal, emergency 
stop input signal, positioning completed signal, interrupt input signal
OutputsPrepare the following outputs for each axis: 
Pulse outputs 
CW/CCW pulses, pulse outputs and direction outputs can be switched. 
Either error counter reset or origin-adjustment command outputs can be selected 
depending on the mode.
Pulse output distribution period1-axis operation: 4 ms 
Linear interpolation: 8 ms
Response timeRefer to Operation manual Appendix A Performance Characteristics.
Self-diagnostic functionFlash memory check, memory loss check, CPU bus check
Error detection functionOvertravel, CPU error, software limit over, emergency stop

mitsubishi C200H-LK202-V1



Brand: OMRON 
Name: Host Link Module
Model: C200H-LK202-V1
Name: Host Link Module.
Model: C200H-LK202-V1.
Communication ports: 1 RS-422.


Model: C200H-OD219.
No. of points: 64 pts.
Specifications: 4.5 VDC, 16 mA to 26.4 VDC, 100 mA..
Weight: 250g max.Name: Position Control Module.
Model: C200HW-NC213.
Control method: Open-loop, automatic trapezoid acceleration/deceleration.
Control output sig-nals: Pulse-train outputs.
Controlled axes: 2 OMRON C200H-LK202-V1. 1 set (2 included).Model: C200H-OD211.
No. of points: 12 pts.
Specifications: 0 C200H-LK202-V13 A, 24 VDC.Model: C200H-ME831.
Description: EEPROM, 8K words, no clock.Name: Position Control Module.
Model: C200H-NC211.
Control method: Open-loop, automatic trapezoid acceleration/deceleration.
Control output sig-nals: Pulse-train outputs.
Controlled axes: 2.Model: C200H-OC222N.
No. of points: 12 pts.
Specifications: 2A, 250VAC/24VDC(For resistive loads) OMRON C200H-LK202-V1. Required when supplying backup power.
For 2 Units.1 axis, Pulse output. speeds: 1 to 100, 000 pps.ISA bus: support software.Model: C200H-BC031-V2.
No. of I/O slots: 3 slots.100 to 120/200 to 240 VAC (switchable), APF/PCF.UM: 15.2K words.
DM: 6K words.
EM: 6K words.
Instruction processing time (basic instructions): 0.15 µ.s min.
No. of I/O points: 880 points OMRON C200H-LK202-V1. 
Max. no.of connecting Expansion I/O Racks: 2 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.Model: C200HW-CORT21-V1 OMRON Host Link Module. 
C200HW C Communications CANopen Master / Slave Unit C200HWCORT21Capacity: 32K word.
Access time: 150ns.
When using SYSMAC-CPT, can not be written in EPROM OMRON Host Link Module. 
To write a program to the EPROM, use the standard PROM writer.
Before the EPPROM memory card into the CPU, to connect the EPROM to the EPROM memory card.
If you remove the EPROM memory card from the CPU,
Will not lose its data.Name: Temperature Control Module.
Model: C200H-TC001.
Sensor: Thermocouple: R, S, K(CA), J(IC), T(CC), E(CRC), B, N, L(IC), U(CC) OMRON Host Link Module. 
Control output: Transistor outputCConnects Power Supply Adapter and SYSMAC NET Link Unit C200H-LK202-V1. 
For 1 Unit.Model: C200HW-COM03-V1.
Specifications: One RS-422/485 port.Model: C200HW-ME08K.
Capacity: 8K words.For 8-slot Backplane.Model: C200H-OD218.
No. of points: 32 ptts OMRON C200H-LK202-V1. 
Specifications: nit 4.5 VDC, 16 mA to 26.4 VDC, 100 mA. .
Weight: 180g max.Connects SYSMAC LINK Unit, Controller Link Unit to CPU Unit.

OMRON CP1W-TS001


Product Details

CP1L Temperature Sensor Input Modules

By mounting a Temperature Sensor Unit to the PLC, inputs can be obtained from thermocouples or platinum resistance thermometers, and temperature measurements can be converted to binary data (4-digit hexadecimal) and stored in the input area of the CPU Unit. 

Omron CP1L CPU's, Expansion Modules and Accessories

Omron's CP1L series offers the compactness of a micro-PLC with the capability of a modular PLC. The range is not only compact, it is scaleable too, and has a faster processing speed than other controllers. 
Specifications
AttributeValue
For Use WithPLC Module
Module TypeInput
Input TypeAnalogue
Number of Inputs2
Voltage Category24 V dc
Length90mm
Width86mm
Depth50mm
Dimensions90 x 86 x 50 mm