Kontak Kami

KONTAK KAMI : Telpon : 02126071413 Hp/WhatsApp : 081212269831 Perwakilan Jakarta : Gedung LTC Glodok Lantai 1 Blok C30 No.31 Jl.Hayam Wuruk No.127 Jakarta , Indonesia

Rabu, 20 Maret 2019

MITSUBISHI Q64TCRTN



  • Manufacturer : Mitsubishi Electric
  • Q64TCRTN
  • Temperature control unit Q 64 TCRTN
  • Control output : Transistor output
  • Number of temperature input points : 4 channels / unit
  • Usable resistance temperature detector : Pt 100, JPt 100
  • accuracy Instruction accuracy Ambient temperature: 25 ± 5 ° C : Full scale X (± 0.3%)
  • Ambient temperature: 0 to 55 ° C : Full scale X (± 0.7%)
  • Sampling cycle : 500 ms / 4 channels
  • Control output period : 1 to 100 s
  • Input impedance : 1 MΩ
  • Input filter : 0 to 100 s (0: input filter OFF)
  • Sensor correction value setting : -50.00 to 50.00%
  • Operation at sensor input disconnection : Upscale processing
  • Temperature control system : PID ON / OFF pulse or 2 position control
  • PID constant range PID constant setting : Setting by auto tuning is possible
  • Proportional band (P) : 0.0 to 1000.0% (0.0: 2 position control)
  • Integration time (I) : 0 to 3600 s (0: P control, PD control)
  • Differential time (D) : 0 to 3600 s (0: P control, PI control)
  • Target value setting range : Within the temperature range set by the platinum resistance bulb to be used
  • Dead band setting range : 0.1 to 10.0%
  • Transistor output Output signal : ON / OFF pulse
  • Rated load voltage : 10 to 30 VDC
  • Maximum load current : 0.1 A / 1 point, 0.4 A / 1 common
  • Maximum inrush current : 0.4 A, 10 ms
  • Leakage current at OFF : 0.1 mA or less
  • Maximum voltage drop during ON : DC 1.0 V (TYP.) 0.1 A, DC 2.5 V (MAX.) 0.1 A
  • Response time OFF → ON : 2 ms or less
  • ON → OFF : 2 ms or less
  • Insulation method : Input terminal and between sequencer power supply and input channel: Transformer insulation
  • Withstand voltage : Between input terminal and sequencer power supply, input channel: AC 500 V for 1 minute
  • Insulation resistance : Between input terminal and sequencer power supply, input channel: DC 500 V 20 MΩ or more
  • External wiring connection method : 18 point screw terminal block (M3 screw)
  • Number of occupied I / O points : 16 points (I / O assignment: 16 points of intelligence)
  • DC 5 V Internal current consumption : 0.29 A
  • External dimensions Height (H) : 98 mm
  • Width (W) : 27.4 mm
  • Depth (D) : 112 mm
  • mass : 0.20 Kg
  • Shipping Weight : 1.2 Kg

MITSUBISHI Q64TCTTN



Spesification

Condition:New
Weight (kg):0.2
Our Part Number:Q64TCTTN
Height (mm):98
Width (mm):27.4
Depth (mm):90
Brand:Mitsubishi
Manufacturer Range:Q Series
Short Description:Mitsubishi Q64TCTTN 4 Loop Temperature Control Module, Thermocouple, Digital Output

MITSUBISHI Q68RD3-G

Mitsubishi Q68RD3-G Platinum Resistance Type Temperature Input Module

  • 8 channels.
  • Platinum thermal resistance (Pt100, JPt100).
  • Nickel thermal resistance (Ni100).
  • Shedding detection function.
  • Conversion speed: 320ms/8 channel.
  • Inter channel isolation.
  • 40 pin connector.
  • Most suitable for process control of isolated analog modules.
  • Temperature data can be collected by connecting thermocouple / thermal resistance.
  • Products can choose multi-channel (8 channel) input type and channel isolation type.


MITSUBISHI Q64RD

Spesification

Condition:New
Weight (kg):0.17
Our Part Number:Q64RD
Height (mm):98
Width (mm):27.4
Depth (mm):90
Brand:Mitsubishi
Manufacturer Range:Q Series
Short Description:Mitsubishi Q Series Pt100 input module, 4 channel

MITSUBISHI Q64RD-G



Mitsubishi Q64RD-G Platinum Resistance Type Temperature Input Module

  • Input: 4 channels.
  • Platinum resistance (Pt100; JPt100; Ni100).
  • Conversion speed: 40ms/1 channel.
  • 18 point terminal.
  • Isolation between channels.
  • Platinum thermal resistance (Pt100, JPt100).
  • Nickel thermal resistance (Ni100).
  • Shedding detection function.
  • Conversion speed: 320ms/8 channel.
  • Inter channel isolation.
  • 40 pin connector.
  • Most suitable for process control of isolated analog modules.
  • Temperature data can be collected by connecting thermocouple / thermal resistance.
  • Products can choose multi-channel (8 channel) input type and channel isolation type.


Selasa, 19 Maret 2019

MITSUBISHI Q68TD-G-H02




Mitsubishi Q68TD-G-H02 Thermocouple Type Temperature Input Module

  • 8 channels.
  • Thermocouple (B, R, S, K, E, J, T, N)
  • Shedding detection function.
  • Conversion speed: 640ms/8 channel.
  • Inter channel isolation.
  • 40 pin connector.
  • Most suitable for process control of isolated analog modules.
  • Temperature data can be collected by connecting thermocouple / thermal resistance.
  • Products can choose multi-channel (8 channel) input type and channel isolation type.


MITSUBISHI Q68TD-G-H01

Mitsubishi Q68TD-G-H01 Thermocouple type temperature input module

  • Input: 8 channels.
  • Thermocouple。
  • Conversion speed: 320ms/8 channel.
  • 40 pin connector.
  • Most suitable for process control of isolated analog modules.
  • Temperature data can be collected by connecting thermocouple / thermal resistance.
  • Products can choose multi-channel (8 channel) input type and channel isolation type.
  • Auto backup key data
  • Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
  • To prevent the loss of the program and the parameters due to forgetting to replace the battery.

MITSUBISHI Q64TDV-GH

Mitsubishi Q64TDV-GH Thermocouple Type Temperature Input Module

  • Input: 4 channels.
  • Thermocouple (C1602~1995 JIS).
  • Micro voltage (-100mV~100mV).
  • Conversion speed: (sampling period x3) /1 channel.
  • 18 point terminal station.
  • Most suitable for process control of isolated analog modules.
  • Temperature data can be collected by connecting thermocouple / thermal resistance.
  • Products can choose multi-channel (8 channel) input type and channel isolation type.
  • Auto backup key data
  • Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
  • To prevent the loss of the program and the parameters due to forgetting to replace the battery.


MITSUBISHI Q64TD

Mitsubishi Q64TD Platinum Resistance Type Temperature Input Module

  • Input: 4 channels.
  • Thermocouple (C1602-1995 JIS).
  • Conversion speed: 40ms/1 channel.
  • 18 point terminal station.
  • Most suitable for process control of isolated analog modules.
  • Temperature data can be collected by connecting thermocouple / thermal resistance.
  • Products can choose multi-channel (8 channel) input type and channel isolation type.
  • Auto backup key data
  • Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
  • To prevent the loss of the program and the parameters due to forgetting to replace the battery.


MITSUBISHI Q68DAIN


Spesification

ConditionNew
Weight (kg)0.18
Our Part NumberQ68DAIN
Height (mm)98
Width (mm)27.4
Depth (mm)90
BrandMitsubishi
Manufacturer RangeQ Series
Short DescriptionMitsubishi Q68DAIN Q Series D/A Output Module, 8 Channel, 0 To 12000 0 To 20ma

MITSUBISHI Q68DAVN


Spesification

ConditionNew
Weight (kg)0.18
Our Part NumberQ68DAVN
Height (mm)98
Width (mm)27.4
Depth (mm)90
BrandMitsubishi
Manufacturer RangeQ Series
Short DescriptionMitsubishi Q68DAVN Q Series D/A Output Module, 8 Channel, 0 To 16000 -10 To +10 V

MITSUBISHI Q66DA-G


Mitsubishi Q66DA-G Analog Output Module

ANALOGUE I/O MODULE
TypeQ SERIES
Power Supply (V)24
Current TypeDC
Occupied I/O Points on PLC16
Occupied StationsN/A
Integrated Analogue InputsN/A
Integrated Analogue Outputs6
Input Voltage Range (V)N/A
Input Current Range (mA)N/A
Output Voltage Range (V)-10-10; 0-5; 1-5
Output Current Range (mA)0-20; 4-20
WiringSCREW
Int. Current Consumption (A)0,62

MITSUBISHI Q64DAH


Mitsubishi Q64DAH Analog Output Module

ANALOGUE I/O MODULE
TypeQ SERIES
Power Supply (V)24
Current TypeDC
Occupied I/O Points on PLC16
Occupied StationsN/A
Integrated Analogue InputsN/A
Integrated Analogue Outputs4
Input Voltage Range (V)N/A
Input Current Range (mA)N/A
Output Voltage Range (V)-10-10; 0-5; 1-5
Output Current Range (mA)0-20; 4-20
WiringSCREW
Int. Current Consumption (A)0,12

MITSUBISHI Q64DAN


  • Q64DAN
  • Programmable Logic Controllers
  • Mitsubishi Electric
  • Q series
  • Number of analog output points: 4 points (4 channels)
  • Digital input: 16-bit signed binary
  • (In standard resolution mode: -4096 to 4095; In high resolution mode: -12288 to 12287, -16384 to 16383)
  • Analog output: Current: DC0mA to 20mA (external load resistance 0? to 600?) 
  • Number E2PROM writings :Max. 100,000 times
  • Output short-circuit protection: Protected
  • Isolation method:- I/O terminal isolation from PLC power supply: Photocoupler isolation
  • Output channel isolation: Not isolated
  • Analog output isolation from external power supply: Transformer isolation
  • Dielectric withstand voltage:-
    Between I/O terminals and PLC power supply: 500VAC for 1 minute
    Between analog output and external power supply: 500VAC for 1 minute
    Insulation resistance: Between I/O terminals and PLC power supply: 500VDC, 20M? or more
    Between analog output and external power supply: 500VDC, 20M? or more
    Number of occupied I/O points: 16 points (I/O assignment: intelligent 16 points)
    Connection terminal:18-point terminal block
    Applicable wire size:0.3 to 0.75mm2
    Applicable solderless terminal: R1.25-3 (sleeved crimp terminals cannot be used)
  • External power supply: -
  • Ripple and spike 500mVP-P or less
  • 24VDC +20%?-15%
  • Shipping Weight: 1.2 Kg

MITSUBISHI Q62DAN


Spesification

Condition:New
Weight (kg):0.19
Our Part Number:Q62DAN
Height (mm):98
Width (mm):27.4
Depth (mm):90
Brand:Mitsubishi
Manufacturer Range:Q Series
Short Description:Mitsubishi Q62DAN Q Series D/A Output Module, 2 Channel, 0 To 16000 -10 To +10 V, 0 To 12000 0 To 20ma

MITSUBISHI Q62DA-FG



Mitsubishi Q62DA-FG Analog Output Module

Mitsubishi Q62DA-FG Q Series D/A Output Module, Ch To Ch Isolated, 2 Channel, 0 To 16000 -10 To +10 V, 0 To 12000 0 To 20ma
TypeQ SERIES
Power Supply (V)24
Current TypeDC
Occupied I/O Points on PLC16
Occupied StationsN/A
Integrated Analogue InputsN/A
Integrated Analogue Outputs2
Input Voltage Range (V)N/A
Input Current Range (mA)N/A
Output Voltage Range (V)-10-10; 0-5; 1-5
Output Current Range (mA)0-20; 4-20
WiringSCREW
Int. Current Consumption (A)0,37

MITSUBISHI Q62AD-DGH


Mitsubishi Q62AD-DGH Analog Input Module

Mitsubishi Q62AD-DGH Q Series A/D Input Module, 2 Channel, With Distributor Function
TypeQ SERIES
Power Supply (V)24
Current TypeDC
Occupied I/O Points on PLC16
Occupied StationsN/A
Integrated Analogue Inputs2
Integrated Analogue OutputsN/A
Input Voltage Range (V)N/A
Input Current Range (mA)4-20
Output Voltage Range (V)N/A
Output Current Range (mA)N/A
WiringSCREW
Int. Current Consumption (A)0,22

MITSUBISHI Q68ADI


Condition:New
Weight (kg):0.19
Our Part Number:Q68ADI
Height (mm):98
Width (mm):27.4
Depth (mm):90
Brand:Mitsubishi
Manufacturer Range:Q Series
Short Description:Mitsubishi Q68ADI Q Series A/D Input Module, 8 Channel, 16 Bit, 0 To 12000   0 To 20ma

MITSUBISHI Q68ADV


Spesification

Condition:New
Weight (kg):0.19
Our Part Number:Q68ADV
Height (mm):98
Width (mm):27.4
Depth (mm):90
Brand:Mitsubishi
Manufacturer Range:Q Series
Short Description:Mitsubishi Q68ADV Q Series A/D Input Module, 8 Channel, 16 Bit, 0 To 16000 -10 To +10 VDC