Kontak Kami

KONTAK KAMI : Telpon : 02126071413 Hp/WhatsApp : 081212269831 Perwakilan Jakarta : Gedung LTC Glodok Lantai 1 Blok C30 No.31 Jl.Hayam Wuruk No.127 Jakarta , Indonesia

Rabu, 20 Maret 2019

FX3U-4AD-PT-ADP

Spesifications

  • Manufacturer : Mitsubishi Electric
  • FX3U-4AD-PT-ADP
  • Analog input adapter for Pt 100 type temperature sensor FX 3 U - 4 AD - PT - ADP
  • Temperature sensor . temperature control input signal : Platinum resistance temperature detector 3 wire type Pt 100 JIS C 1604 - 1997
  • Number of input channels : 4 channels
  • Rated temperature range : -50 ° C to + 250 ° C (-58 ° F to + 482 ° F)
  • Digital output : -500 to + 2500 (-580 to + 4820 ) Within parentheses, the digital value at Fahrenheit setting
  • resolution : 0.1 ° C (0.18 ° F)
  • Overall accuracy : Ambient temperature 25 ° C ± 5 ° C: ± 0.5% with full scale Ambient temperature 0 ° C to 55 ° C: ± 1.0% with full scale
  • control method : Depending on the sequence program
  • Conversion speed FX3U / FX3UC PLC : 200 μs (Data update every calculation cycle)
  • FX3S / FX3G / FX3GC Sequencer : 250 μs (Data update every calculation cycle)
  • Insulation method : . Isolation between analog input part and sequencer by photo coupler . Insulation between analog input part and power supply by DC / DC converter . No isolation between each channel
  • Number of occupied I / O points : 0 point (It does not relate to the maximum input / output point number of the sequencer)
  • Application sequencer : FX3S, FX3G, FX3U, FX3GC, FX3UC (FX3UC - 32MT - LT is Ver.1.30 or later) FX3S - CNV - ADP is required for connection to FX3S. For connection to FX 3 G, FX 3 G - CNV - ADP is required. To connect to FX3U and FX3UC - 32MT - LT (-2), a function expansion board is required.
  • mass : 0.1 Kg
  • Power supply : DC 5 V 15 mA (internal power supply from the sequencer) DC 24 V + 20% -15% 50 mA (external power supply)
  • Ambient temperature : 0 to 55 ° C. ... Operating -25 to 75 ° C. ..... Save
  • Relative humidity : 5 to 95% RH (noncondensing).... in operation
  • Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total)
  • Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total)
  • Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total)
  • Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 10 times in X, Y, Z directions (80 minutes in total)
  • Impact resistance : 147 m / s 2 , working time 11 ms, three times in X, Y, Z directions with a sine half-wave pulse
  • Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 μs, rising 1 ns, with noise si
  • tor with period of 30 to 100 Hz
  • Withstand voltage : Between all terminals and ground terminal: 500 VAC for 1 minute
  • Insulation resistance : Between all terminals and ground terminal: 500 MV DC 500 MΩ or more with an insulation resistance meter
  • ground : Class D grounding (grounding resistance: 100 Ω or less)Grounding should be dedicated ground or common ground.
  • Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious
  • Use altitude : Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.
  • Shipping Weight : 1.1 Kg

FX3U-3A-ADP


Spesifications

  • Manufacturer : Mitsubishi Electric
  • FX3U-3A-ADP
  • Analog input / output adapter FX3U - 3A - ADP
  • Analog input Analog input range Voltage input : DC 0 to 10 V (input resistance 198.7 kΩ)
  • Current input : DC 4 to 20 mA (input resistance 250 Ω)
  • Number of input channels : 2 channels
  • Absolute maximum input Voltage input : -0.5 V, +15 V
  • Current input : -2 mA, +30 mA
  • Input characteristics : Input mode (voltage / current input) can be set for each channel.
  • Digital output : 12 bit binary
  • resolution Voltage input : 2.5 mV (10 V x 1/4000)
  • Current input : 5 μA (16 mA X 1/3200)
  • Overall precision Voltage input : Ambient temperature 25 ° C ± 5 ° C ± 0.5% (± 50 mV) to full scale 10 V Ambient temperature 0 ° C to 55 ° C ± 1.0% (± 100 mV) to full scale 10 V
  • Current input : Ambient temperature 25 ° C ± 5 ° C ± 0.5 % (± 80 μA) against full scale 16 mA Ambient temperature 0 ° C to 55 ° C ± 1.0% (± 160 μA) for full scale 16 mA
  • A / D conversion time When FX3U / FX3UC sequencer is connected : 80 μs X Number of used input channels + 40 μs X Number of output output channels (data update every calculation cycle)
  • When FX3S / FX3G / FX3GC programmable controller is connected : 90 μs X number of used input channels + 50 μs X number of output output channels (data update every calculation cycle)
  • Insulation method : . Insulation between analog input / output section and sequencer by photo coupler . Insulation between drive power supply and analog input / output section by DC / DC converter . No isolation between each channel
  • Analog output Analog output range Voltage output : DC 0 to 10 V (external load resistance 5 k to 1 MΩ)
  • Current output : DC 4 to 20 mA (external load resistance 500 Ω or less)
  • Number of output channels : 1 channel
  • Output characteristics : Output mode (voltage / current output) can be set.
  • Digital input : 12 bit binary
  • resolution Voltage output : 2.5 mV (10 V x 1/4000)
  • Current output : 4 μA (16 mA X 1/4000)
  • Overall precision Voltage output : Ambient temperature 25 ° C ± 5 ° C ± 0.5% (± 50 mV) to full scale 10 V Ambient temperature 0 ° C to 55 ° C ± 1.0% (± 100 mV) to full scale 10 V External load resistance (Rs) is less than 5 kΩ In addition, the following calculations increase. (It increases by 100 mV per 1%.) 47 X 100 / (Rs + 47) - 0.9 (%)
  • Current output : Ambient temperature 25 ° C ± 5 ° C ± 0.5 % (± 80 μA) against full scale 16 mA Ambient temperature 0 ° C to 55 ° C ± 1.0% (± 160 μA) for full scale 16 mA
  • D / A conversion time When FX3U / FX3UC sequencer is connected : 80 μs X Number of used input channels + 40 μs X Number of output output channels (data update every calculation cycle)
  • When FX3S / FX3G / FX3GC programmable controller is connected : 90 μs X number of used input channels + 50 μs X number of output output channels (data update every calculation cycle)
  • Insulation method : . Insulation between analog input / output section and sequencer by photo coupler . Insulation between drive power supply and analog input / output section by DC / DC converter . No isolation between each channel
  • Number of occupied I / O points : 0 point (It does not relate to the maximum input / output point number of the sequencer)
  • Application sequencer : FX3S, FX3G (Ver.1.20 or later), FX3U (Ver.2.61 or later), FX3GC, FX3UC (Ver.2.61 or later) FX3S - CNV - ADP is required for connection to FX3S. For connection to FX 3 G, FX 3 G - CNV - ADP is required. To connect to FX3U and FX3UC - 32MT - LT (-2), a function expansion board is required.
  • mass : About 0.1 Kg
  • Power supply Conversion circuit drive power supply : DC24 V + 20% -15% 90 mA Connect a 24 VDC power supply to the terminal block and supply it.
  • Interface drive power supply : DC 5 V 20 mA Internal power is supplied from the DC 5 V power supply of the basic unit.
  • Ambient temperature : 0 to 55 ° C. ... Operating -25 to 75 ° C. ..... Save
  • Relative humidity : 5 to 95% RH (noncondensing).... in operation
  • Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total)
  • Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total)
  • Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total)
  • Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 10 times in X, Y, Z directions (80 minutes in total)
  • Impact resistance : 147 m / s 2 , working time 11 ms, three times in X, Y, Z directions with a sine half-wave pulse
  • Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 μs, rising 1 ns, with noise si
  • tor with period of 30 to 100 Hz
  • Withstand voltage : Between all terminals and ground terminal: 500 VAC for 1 minute
  • Insulation resistance : Between all terminals and ground terminal: 500 MV DC 500 MΩ or more with an insulation resistance meter
  • ground : Class D grounding (grounding resistance: 100 Ω or less)Grounding should be dedicated ground or common ground.
  • Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious
  • Use altitude : Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.
  • Shipping Weight : 1.1 Kg

FX3U-4DA-ADP


Spesifications

  • Manufacturer: Mitsubishi Electric 
  • Analogue output adapter FX3U-4DA-ADP
  • Analog output range Voltage output : DC0V ~ 10V (external load 5kΩ ~ 1MΩ) 
  • Current output : DC4mA ~ 20mA (or less external load 500Ω) 
  • Number of output channels : 4 channel 
  • Output characteristic: For each channel, you can set the output mode (voltage / current output). 
  • Digital input : 12bit binary 
  • resolution Voltage output : 2.5mV (10V × 1/4000) 
  • Current output : 4μA (16mA × 1/4000) 
  • Overall accuracy Voltage output : Ambient temperature 25 °C ± 5 °C: 0.5% ± with respect to full-scale 10V (± 50mV)
    ambient temperature 0 °C ~ 55 °C: ± 1.0 % for the full-scale 10V (± 100mV)
    external load resistance (Rs) is less than 5kΩ If, following the calculation amount will increase. (100mV will increase per Pasento 1)
    (47 × 100) ÷ (Rs Tasu 47) -0.9 (Pasento) 
  • Current output : Ambient temperature 25 °C ± 5 °C: 0.5% ± with respect to full-scale 16mA (± 80μA)
    ambient temperature 0 °C ~ 55 °C: full scale 16mA for ± 1.0% (± 160μA) 
  • D / A conversion time FX3U / FX3UC PLC : 200μs (every calculation cycle update of the data) 
  • FX3S / FX3G / FX3GC sequencer : 250μs (every calculation cycle update of the data) 
  • Insulation method : Analog output section and between the sequencer, insulated by photo-coupler is between the power supply and the analog output section, insulated by a DC / DC converter is between-each channel, non-isolated 
  • O occupied points : 0 points (no relation to the maximum input and output points of the sequencer) 
  • Apply sequencer : FX3S, FX3G, FX3U, FX3GC, FX3UC (FX3UC-32MT-LT since Ver.1.20)
    connection to the FX3S is required FX3S-CNV-ADP.
    Connection to the FX3G is required FX3G-CNV-ADP.
    Connection to the FX3U and FX3UC-32MT-LT (-2), you must have the function expansion board. 
  • mass : 0.1kg 
  • Power Specifications : -
  • Power supply :
    DC5V 15mA (internal power supply from the sequencer)
    DC24V Tasu 20 Pasento -15 Pasento 150MA (external power supply) 
  • Ambient temperature : 0 ~ 55 °C ····· -25 ~ 75 °C ····· during storage operations 
  • Relative humidity : 5 ~ 95% RH (non-condensing) ...... operation 
  • Vibration resistance When the DIN rail mounting- Frequency: 10 ~ 57Hz : Half amplitude: 0.035mm X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • When the DIN rail mounting- Frequency: 57 ~ 150Hz : Acceleration: 4.9m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Direct mounting at the time- Frequency: 10 ~ 57Hz : Half amplitude: 0.075mm X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Direct mounting at the time- Frequency: 57 ~ 150Hz : Acceleration: 9.8m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Impact : 147m / s2, duration of action 11ms, X at half-sine pulse, Y, Z directions 3 times each 
  • Anti-noise : Noise voltage 1,000Vp-p, noise width 1μs, due to rising 1ns, cycle 30 ~ 100Hz of noise simulator 
  • Withstand voltage : All terminals and between the ground terminal: AC500V 1 minute 
  • Insulation resistance : All terminals and between the ground terminal: DC500V 5MΩ more in insulation resistance tester 
  • Ground: Class D grounding (ground resistance: 100Ω or less) <common ground is not allowed with the high-voltage system>
    ground, please dedicated ground or shared ground. 
  • Use atmosphere : Corrosive, there is no flammable gas, conductive dust (dust) that is not terribly 
  • Advanced use : 2000m or less can not be used in the pressurized environment to more than atmospheric pressure. There is a possibility of failure. 
  • Shipping Weight: 1.1 Kg

FX3U-4AD-ADP


Spesifications

Condition:New
Weight (kg):0.1
Our Part Number:FX3U4ADADP
Height (mm):90
Width (mm):17.6
Depth (mm):89.5
Brand:Mitsubishi
Manufacturer Series:FX3U
Manufacturer Range:FX Series
Short Description:Mitsubishi FX3U-4AD-ADP Analogue Input Module, 12 Bit, 4 Analogue Inputs For Current Or Voltage

FX3G-2EYT-BD


Spesifications

Condition:New
Weight (kg):0.02
Our Part Number:FX3G2EYTBD
Height (mm):51.2
Width (mm):35
Depth (mm):29.2
Brand:Mitsubishi
Manufacturer Series:FX3G
Manufacturer Range:FX Series
Short Description:Mitsubishi FX3G2EYTBD FX3S/3G Output Expansion Board (2 Transistor Outputs, Sink/Source)

FX3G-4EX-BD

Spesifications

Condition:New
Weight (kg):0.02
Our Part Number:FX3G4EXBD
Height (mm):51.2
Width (mm):35
Depth (mm):29.2
Brand:Mitsubishi
Manufacturer Series:FX3G
Manufacturer Range:FX Series
Short Description:Mitsubishi FX3G4EXBD FX3S/3G Input Expansion Board (4 Inputs, Sink/Source)

FX3G-8AV-BD


Spesifications

Condition:New
Weight (kg):0.02
Our Part Number:FX3G8AVBD
Height (mm):51.2
Width (mm):35
Depth (mm):12
Brand:Mitsubishi
Manufacturer Series:FX3G
Manufacturer Range:FX Series
Short Description:Mitsubishi FX3G-8AV-BD FX3S/3G Analogue Set Point Adapter For 8 Set Point Values

FX3G-1DA-BD


Spesifications

  • Manufacturer : Mitsubishi Electric
  • FX3G-1DA-BD
  • Analog output board FX3G - 1DA - BD
  • Analog output Analog output range Voltage output : DC 0 V to 10 V (external load resistance 2 kΩ to 1 MΩ)
  • Current output : DC 4 mA to 20 mA (external load resistance 500 Ω or less)
  • Number of output channels : 1 channel
  • Output characteristics : Output characteristics can not be adjusted.
  • Digital input Voltage output : 12 bit binary
  • Current output : 11 bit binary
  • resolution Voltage output : 2.5 mV (10 V x 1/4000)
  • Current output : 8 μA (16 mA X 1/2000)
  • Overall precision Voltage output : Ambient temperature 25 ° C ± 5 ° C: ± 0.5% (± 50 mV) against full scale 10 V Ambient temperature 0 ° C to 55 ° C: Shipment adjusted to ± 1.0% (± 100 mV) external load resistance 2 kΩ for full scale 10 V . Therefore, when it is larger than 2 kΩ, the output voltage slightly increases. In the case of 1 MΩ, the output voltage is up to 2% higher.
  • Current output : Ambient temperature 25 ° C ± 5 ° C ± 0.5 % (± 80 μA) against full scale 16 mA Ambient temperature 0 ° C to 55 ° C ± 1.0% (± 160 μA) for full scale 16 mA
  • D / A conversion time : 60 μs (Data update every calculation cycle)
  • Insulation method : No isolation between analog input and sequencer, between channels
  • Number of occupied I / O points : 0 point (It does not relate to the maximum input / output point number of the sequencer)
  • Application sequencer : FX3S, FX3G (V1.10 or later) When connecting FX3S, you can not use FX3S - CNV - ADP together with function expansion board.
  • Ambient temperature : 0 to 55 ° C. ... Operating, -25 to 75 ° C. ..... Save
  • Relative humidity : 5 to 95% RH (noncondensing).... in operation
  • Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total)
  • Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total)
  • Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total)
  • Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 10 times in X, Y, Z directions (80 minutes in total)
  • Impact resistance : 147 m / s 2 , working time 11 ms, three times in X, Y, Z directions with a sine half-wave pulse
  • Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 μs, rising 1 ns, with noise si
  • tor with period of 30 to 100 Hz
  • Withstand voltage : Non-insulated between analog output part and PLC main body (Do not perform withstand voltage test)
  • Insulation resistance : Non-insulated between the analog output part and the programmable controller (Do not conduct the insulation resistance test)
  • Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious
  • Use altitude : It can not be used under an environment pressurized to 2,000 m or less under atmospheric pressure. It may break down.
  • Shipping Weight : 1 Kg

FX3G-2AD-BD


Spesifications

  • Manufacturer: Mitsubishi Electric 
  • Analog input board FX3G-2AD-BD 
  • Analog input Analog input range Voltage input : DC0V ~ 10V (input resistance 198.7kΩ) 
  • Current input : DC4mA ~ 20mA (input resistance 250Ω) 
  • The number of input channels 2 channel 
  • The absolute maximum input Voltage input : -0.5V, + 15V 
  • Current input : -2mA, + 30mA 
  • Input characteristic : And voltage and current inputs, you can use a mix. - Input characteristics can not be adjusted. 
  • Digital output Voltage input : 12bit binary 
  • Current input : 11bit binary 
  • resolution Voltage input : 2.5mV (10V × 1/4000) 
  • Current input : 8μA (16mA × 1/2000) 
  • Overall accuracy Voltage input : Ambient temperature 25 °C ± 5 °C: 0.5% ± with respect to full-scale 10V (± 50mV) ambient temperature 0 °C ~ 55 °C: full scale 10V for ± 1.0% (± 100mV) 
  • Current input : Ambient temperature 25 °C ± 5 °C: 0.5% ± with respect to full-scale 16mA (± 80μA) ambient temperature 0 °C ~ 55 °C: full scale 16mA for ± 1.0% (± 160μA) 
  • A / D conversion time : 180μs (every calculation cycle update of the data) 
  • Insulation method : Analog input and inter-sequencer, non-isolated both between each channel 
  • O occupied points : 0 points (no relation to the maximum input and output points of the sequencer) 
  • Apply sequencer : FX3S, FX3G (V1.10 or later)
    FX3S when connected, it can not be used in conjunction function expansion board and FX3S-CNV-ADP. 
  • Ambient temperature : 0 ~ 55 °C ····· -20 ~ 70 °C ····· during storage operations 
  • Relative humidity : 5 ~ 95% RH (non-condensing) ..... operation 
  • Vibration resistance When the DIN rail mounting Frequency: 10 ~ 57Hz : Half amplitude: 0.035mm X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Frequency: 57 ~ 150Hz : Acceleration: 4.9m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Direct mounting at the time Frequency: 10 ~ 57Hz : Half amplitude: 0.075mm X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Frequency: 57 ~ 150Hz : Acceleration: 9.8m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Impact : 147m / s2, duration of action 11ms, X at half-sine pulse, Y, Z directions 3 times each 
  • Anti-noise : Noise voltage 1,000Vp-p, noise width 1μs, due to rising 1ns, cycle 30 ~ 100Hz of noise simulator 
  • Withstand voltage : Non-isolated between the analog input and the PLC main unit (Please do not withstand voltage test) 
  • Insulation resistance : Non-isolated between the analog input and the PLC main unit (Please do not insulation resistance test) 
  • Use atmosphere : Corrosive, there is no flammable gas, conductive dust (dust) that is not terribly 
  • Advanced use : 2,000m or less can not be used under the pressurized environment to more than atmospheric pressure. There is a possibility of failure.
  • Shipping Weight : 1 Kg

FX3G-485-BD-RJ


Spesifications
Description:FX3S/3G RS 485 board (non isolated, RJ45 connector)
Manufacturer:Mitsubishi
Height (mm):51.2
Width (mm):35
Depth (mm):22
Weight (kg):0.02

FX3G-485-BD


Spesifications

  • Manufacturer: Mitsubishi Electric 
  • RS-485 communication for function expansion board FX3G-485-BD
  • Transmission standard : RS-485 standard, conform to the RS-422 standard 
  • Insulation method : Non-insulated (between the communication line and the CPU) 
  • Transmission distance : Up to 50m 
  • External device connection method : Europe terminal blocks 
  • Communication system : Half-duplex bi-directional 
  • Communication procedure : Non-procedural, computer link (dedicated protocol format 1, dedicated protocol format 4), parallel link, a simple PC-to-PC link, inverter communication
    FX3G is compatible with the inverter communication later Ver.1.10. 
  • communication speed No-protocol, the computer link : 300/600/1200/2400/4800/9600/19200/38400 (bps) 
  • Parallel link : 115200 (bps) 
  • Simple PC-to-PC link : 38400 (bps) 
  • Inverter communication : 4800/9600/19200/38400 (bps) 
  • Display (LED) : RD, SD 
  • O occupied points : 0 points (no relation to the maximum input and output points of the sequencer) 
  • Apply sequencer : FX3S, FX3G
    FX3S when connected, can not be used in conjunction function expansion board and FX3S-CNV-ADP. 
  • Ambient temperature : 0 ~ 55 °C ····· operation, -25 ~ 75 °C ····· during storage 
  • Relative humidity : 5 ~ 95% RH (non-condensing) ...... operation 
  • Vibration resistance When the DIN rail mounting Frequency: 10 ~ 57Hz : Half amplitude: 0.035mm X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Frequency: 57 ~ 150Hz : Acceleration: 4.9m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Direct mounting at the time Frequency: 10 ~ 57Hz : Half amplitude: 0.075mm X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Frequency: 57 ~ 150Hz : Acceleration: 9.8m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Impact : 147m / s2, duration of action 11ms, X at half-sine pulse, Y, Z directions 3 times each 
  • Anti-noise : Noise voltage 1,000Vp-p, noise width 1μs, due to rising 1ns, cycle 30 ~ 100Hz of noise simulator 
  • Withstand voltage : Non-isolated between communication line and the PLC main unit
    (Please do not withstand voltage test) 
  • Insulation resistance : Non-isolated between communication line and the PLC main unit
    (Please do not insulation resistance test) 
  • Use atmosphere : Corrosive, there is no flammable gas, conductive dust (dust) that is not terribly 
  • Advanced use : 2,000m or less (can not be used under the pressurized environment to more than atmospheric pressure. There is a possibility of failure.)
  • Shipping Weight : 1 Kg

FX3G-422-BD


Spesifications

  • Manufacturer: Mitsubishi Electric 
  • FX3G-422-BD 
  • RS-422 communication function expansion board FX3G-422-BD 
  • Transmission standard : It conforms to the RS-422 standard 
  • Insulation method : Non-insulated (between the communication line and the CPU) 
  • Transmission distance : Up to 50m 
  • External device connection method : MINI DIN 8pin (female) 
  • Communication system : Half-duplex bi-directional 
  • Communication procedure : Programming communication 
  • communication speed : 9600/19200/38400/57600/115200 (bps) 
  • O occupied points : 0 points (no relation to the maximum input and output points of the sequencer) 
  • Apply sequencer : FX3S, FX3G
    FX3S when connected, can not be used in conjunction function expansion board and FX3S-CNV-ADP. 
  • Ambient temperature : 0 ~ 55 °C ····· operation, -25 ~ 75 °C ····· during storage 
  • Relative humidity : 5 ~ 95% RH (non-condensing) ...... operation 
  • Vibration resistance When the DIN rail mounting Frequency: 10 ~ 57Hz : Half amplitude: 0.035mm X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Frequency: 57 ~ 150Hz : Acceleration: 4.9m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Direct mounting at the time Frequency: 10 ~ 57Hz : Half amplitude: 0.075mm X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Frequency: 57 ~ 150Hz : Acceleration: 9.8m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes) 
  • Impact : 147m / s2, duration of action 11ms, X at half-sine pulse, Y, Z directions 3 times each 
  • Anti-noise : Noise voltage 1,000Vp-p, noise width 1μs, due to rising 1ns, cycle 30 ~ 100Hz of noise simulator 
  • Withstand voltage : Non-isolated between communication line and the PLC main unit
    (Please do not withstand voltage test) 
  • Insulation resistance : Non-isolated between communication line and the PLC main unit
    (Please do not insulation resistance test) 
  • Use atmosphere : Corrosive, there is no flammable gas, conductive dust (dust) that is not terribly 
  • Advanced use : 2,000m or less
    can not be used under the pressurized environment to more than atmospheric pressure. There is a possibility of failure. 
  • Shipping Weight : 1 Kg

FX3G-232-BD


Spesifications

More Information
Condition:New
Weight (kg):0.02
Our Part Number:FX3G232BD
Height (mm):51.2
Width (mm):35
Depth (mm):17.2
Brand:Mitsubishi
Manufacturer Series:FX3G
Manufacturer Range:FX Series
Short Description:Mitsubishi Fx3s/3g Interface Module Rs232c Number inputs:40 Number Outputs:40
Supply Voltage              :100 to 240 Volt