Delta IFD9506

Delta IFD9506

Ethernet Communication Devices
  • Combines the most popular Ethernet and industrial products
  • ‧Crosses the boundary of traditional types of transmissions
  • Offers 10/100M bps high-speed transmission and highly efficient monitoring
Features & Benefits :
  • Isolation in RS-485 channel (incl. power supply)
  • Supports Modbus TCP protocol
  • Smart Monitor
  • Supports webpage setup & on-line monitoring
  • Serial Virtual COM available
  • 3 e-mail alarms (DI)
Specifications :
Network Interface
  • Transmission method: IEEE 802.3, IEEE 802.3u
  • Transmission interface: RJ-45 MDI/MDIX, no jumper cable required
  • Baudrate: 10/100M bps, auto-detection
  • Network protocols: ICMP, IP, TCP, UDP, DHCP, SMTP, Modbus TCP
  • Power supply voltage: 24 VDC (-15 to 20%)
  • Power consumption: 3 W
  • Insulation voltage: 500 V
RS-485 Interface
  • Connector 1: RJ-11, 10-pin feed through terminal
  • Connector 2: 3-pin, removable
  • Transmission method: RS-485
  • Serial baudrate: 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 bps
  • Data type: Modbus ASCII/RTU, user-defined

Delta IFD9503


Delta IFD9503

CANopen Communication Devices
  • Flexible configuration
  • Supports CANopen DS301 and DSP402 protocols
  • Conducts multi-axis, high-speed and intricate motion control by max. baudrate 1M bps
Features & Benefits :
  • Supports CANopen protocol
  • Connectable to all Delta@@s industrial automation products
  • Isolation in CANopen channel (incl. power supply)
  • Passed full compatibility test
Specifications :
  • Transmission method: CAN
  • Electrical isolation: 500 VDC
  • Connector: Removable, 5.08mm
  • Transmission cables: 2 communication cables, 2 power cables, 1 shielded cable
  • Serial baudrate: 10k, 20k, 50k, 125k, 250k, 500k, 800k, 1M bps
  • Power supply voltage: 24 VDC (-15 to 20%)
  • Current: 28 mA (typical), 125 mA impulse current (24 DC)

Delta IFD9502


Delta IFD9502

DeviceNet Communication Devices
  • Supports connections with products of other brands
  • Wire-saving network topology
  • Offers 500k bps fieldbus data transmission of high stability and high interference resistance
  • Applicable in intricate industrial sites
Features & Benefits :
  • Supports DeviceNet protocol
  • Connectable to all Delta’s industrial automation products
  • Isolation in DeviceNet channel (incl. power supply)
  • Passed full compatibility test
Specifications :
  • Transmission method: CAN
  • Electrical isolation: 500 VDC
  • Connector: Removable, 5.08mm
  • Transmission cables: 2 communication cables, 2 power cables, 1 shielded cable
  • Serial baudrate: 125, 250, 500k bps
  • Network voltage: 24 VDC (11 to 25 VDC)
  • Current: 28 mA (typical), 125 mA impulse current (24 VDC)

Delta IFD8520


Delta IFD8520

Modbus Serial Communication Devices
  • Supports Modbus serial communication
  • Offers additional RS-232, RS-422 and RS-485 ports and conversions among channels for various on-site demands
Features & Benefits :
  • An addressable serial communication converter
  • Sets up Modbus address
  • Isolation in RS-485 channel (incl. power supply)
Specifications :
  • Power supply: +9 to +35 VDC
  • Power consumption: 1 W
  • Insulation voltage: 3,000 VDC
  • Baudrate: 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 bps
  • Connector: 9-pin D-SUB (receptacle)
  • Terminal: 10-pin, accepts AWG1-#12 to #24 wires
  • Dimensions (L×W×H): 4.65×2.79×0.87in (118×71×22mm

Delta IFD8510-A

Delta IFD8510-A

Isolated RS-485/RS-422 Repeater
We replaced IFD8510 with IFD8510-A. The key function is repeating the RS-485/RS-422 differential signals to get longer communication distance than 1200m or more communication nodes than 32 nodes. Moreover, it supports RS-485 half-duplex, RS-422 full duplex and data flow auto-detect and auto-switch.
Features & Benefits :
  • Detect and configure the communication format automatically
  • Switch-less and fully-isolated design
  • Communication baud rate: up to 115200bps
Specifications :
  • Power supply: +9V ~ +48VDC
  • Power consumption: 0.4 W
  • Insulation voltage: 5,000 VDC
  • Baud rate: Up to 115200 bps (Auto)
  • Terminal: 10-pin, accepts AWG1-#12 to #24 wires
  • Dimensions(L*W*H):4.80*2.79*0.87in (122*71*22mm)
  • Weight: 133g

Delta IFD8500-A


Delta IFD8500-A

Isolated RS-232 to RS-485/RS-422 Converters
We replaced IFD8500 with IFD8500-A. The key function is transferring the RS-232 signals to RS-485/RS-422 differential signals. The RS-232 interface of computer, PLC and other controllers could be converted to RS-485/RS-422 interface for long communication distance and simple multi-points industrial network
Features & Benefits :
  • Detect and configure the communication protocols automatically
  • Switch-less and fully-isolated design
  • Communication baud rate: up to 115200bps
Specifications :
  • Power supply: +9V ~ +48VDC
  • Power consumption: 0.4 W
  • Insulation voltage: 5,000 VDC
  • Baud rate: Up to 115200 bps (Auto)
  • Connector: 9-pin D-SUB (receptacle)
  • Terminal: 10-pin, accepts AWG1-#12 to #24 wires
  • Dimensions (L*W*H):4.65*2.79*0.87in (118*71*22mm)
  • Weight: 122g

Delta IFD6530


Delta IFD6530

Modbus Serial Communication Devices
  • Supports Modbus serial communication
  • Offers additional RS-232, RS-422 and RS-485 ports and conversions among channels for various on-site demandS
Features & benefits :
  • A USB/RS-485 communication converter for C2000 series AC motor drive only
  • Offers 9V power supply
  • Supports keypad (KPC-CC01) for VFD series AC motor drive in conducting parameter storage and page editing in TPEditor software
  • Supports baudrate 75 ~ 115,200 bps
  • No external power supply required
  • Auto-detects the direction of data flow
  • A USB portable device
Specifications :
  • Power supply: No external power supply required
  • Power consumption: 0.6 W
  • Insulation voltage: 1,000 VDC
  • Baudrate: 75, 150, 300, 600, 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 bps
  • USB connector: A type (plug)
  • RS-485 terminal: RJ-45 (8-pin)
  • Dimensions (L×W×H): 3.15×0.89×0.83in (80mm×22.5mm×21.2mm

Delta IFD6503

Delta IFD6503

CANopen Communication Devices
  • Flexible configuration
  • Supports CANopen DS301 and DSP402 protocols
  • Conducts multi-axis, high-speed and intricate motion control by max. baudrate 1M bps
Features & Benefits :
A USB/CAN communication converter
Extracts CAN message (incl. standard & extended frames), decodes and displays following DeviceNet and CANopen protocols.
Filters by set conditions
Sends CAN messages, 1 message by manual mode, 8 messages by auto mode
Max. baudrate: 1M bps
A portable USB device
Specifications :
  • Power supply: No external power supply required
  • Power consumption: 0.6 W
  • Insulation voltage: 500 VDC
  • Baudrate: 10k, 20k, 50k, 100k, 125k, 250k, 500k, 800k, 1M bps
  • USB connector: A type (plug)
  • RS-485 terminal: RJ-45 (8-pin)
  • Dimensions (L×W×H): 3.15×0.89×0.83in (80×22.5×21.2mm)

Delta IFD6500


Delta IFD6500

Modbus Serial Communication Devices
  • Supports Modbus serial communication
  • Offers additional RS-232, RS-422 and RS-485 ports and conversions among channels for various on-site demands
Features & Benefits :
  • A USB/RS-485 communication converter
  • Supports baudrate 75 ~ 115,200 bps
  • No external power supply required
  • Auto-detects the direction of data flow
  • A USB portable device
Specifications :
  • Power supply: No external power supply required
  • Power consumption: 0.4 W
  • Insulation voltage: 2,500 VDC
  • Baudrate: 75, 150, 300, 600, 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 bps
  • USB connector: A type (plug)
  • RS-485 terminal: RJ-45 (8-pin)
  • Dimensions (L×W×H): 3.15×0.89×0.83in (80×22.5×21.2mm)

Delta DVPSCM52-SL

Delta DVPSCM52-SL

BACnet Communication Module
Can be easily installed and applied on building automation to lower the cost of system maintenance
Features & Benefits :
  • Supports BACnet MS/TP slave protocol
  • Easy to be connected and controlled via software of other brands
  • Functions as BACnet MS/TP remote I/O or gateway
  • Supports MODBUS with user-defined protocol
  • High noise immunity
  • High speed module on the left (PLC needed)
Specifications :
  • Transmission method: RS-485/RS-422
  • Type : Feed-through terminals, with spring plugs
  • Terminal resistance : built in 120 ohm with a switch
  • Baudrates : 1,200、2,400、4,800、9,600、19,200、38,400、57,600、76,800,、115,200、230,400、460,800 bps
  • Communication protocol : BACnet MS/TP Slave、MODBUS ASCII/RTU、UD Link

Delta DVPSCM12-SL

Delta DVPSCM12-SL

Modbus Serial Communication Devices
  • Supports Modbus serial communication
  • Offers additional RS-232, RS-422 and RS-485 ports and conversions among channels for various on-site demands
Features & Benefits :
  • PLC extension module to amplify signals for the left-side communication and support uploading and downloading of PLC program and parameters
  • Provides two stand-alone RS-485/RS-422 ports
  • Supports standard MODBUS protocol
  • Supports user-defined communication protocol
  • Fully isolates communication interfaces and highly capable in resisting interferences
Specifications :
  • Transmission method: RS-485/RS-422
  • Connector type: Euro-type terminal blocks with feed-through terminals and spring plugs
  • Terminal resistors: built-in and changed-over by switches
  • Serial baudrates: 1,200、2,400、4,800、9,600、19,200、38,400、57,600、115,200、230,400、460,800 bps
  • Data type: Modbus ASCII/RTU、UD Link (user-defined communication protocol)

Delta DVPPF02-SL

Delta DVPPF02-SL

PROFIBUS Communication Devices
  • Supports max. baudrate 12M bps
  • Applicable for distributed control system in industrial automation
Featuares & Benefits :
  • A Left-side high-speed PROFIBUS DP slave module for DVP-S series PLC only.
  • Supports PROFIBUS DP protocol
  • Auto detection for transmission speed. Max. baudrate: 12Mbps
  • Supports cyclic data transmission between master module.
  • Data transmission: supports up to 100 words of I/O inputs and 100 words of I/O outputs
Specifications :
  • Transmission method: High-speed RS-485
  • Connector: D-SUB 9
  • Serial baudrate: 9.6k, 19.2k, 93.75k, 187.5k, 500k, 1.5M, 3M, 6M, 12M bps
  • Message type: DPV0
  • Power supply voltage: 24 VDC (-15 to 20%)

Delta DVPPF02-H2


Delta DVPPF02-H2

PROFIBUS Communication Devices
  • Supports max. baudrate 12M bps
  • Applicable for distributed control system in industrial automation
Features & Benefits :
  • A PROFIBUS DP slave module for DVP-EH2 series PLC only
  • Supports PROFIBUS DP protocol
  • Max. baudrate: 12M bps
Specifications :
  • Transmission method: High-speed RS-485
  • Connector: DB9
  • Serial baudrate: 9.6k, 19.2k, 93.75k, 187.5k, 500k, 1.5M, 3M, 6M, 12M bps
  • Message type: DPV0
  • Power supply voltage: 24 VDC (-15 to 20%)

Delta DVPPF01-S

Delta DVPPF01-S

PROFIBUS Communication Devices
  • Supports max. baudrate 12M bps
  • Applicable for distributed control system in industrial automation
Features & Benefits :
  • A PROFIBUS DP slave module for DVP-S series PLC only
  • Supports PROFIBUS DP protocol
  • Max. baudrate: 12M bps
  • With RS-485 port, connectable to max. 16 devices
Specifications :
  • Transmission method: High-speed RS-485
  • Connector: DB9
  • Serial baudrate: 9.6k, 19.2k, 93.75k, 187.5k, 500k, 1.5M, 3M, 6M, 12M bps
  • Message type: DPV0
  • Power supply voltage: 24 VDC (-15 to 20%

Delta DVPEN01-SL


Delta DVPEN01-SL

Ethernet Communication Devices
  • Combines the most popular Ethernet and industrial products
  • ‧Crosses the boundary of traditional types of transmissions
  • Offers 10/100M bps high-speed transmission and highly efficient monitoring
Features & Benefits :
For DVP-EH3-L, DVP-MC, DVP-SA2, SE, SV2, SX2 Series PLC only
  • ‧Supports Modbus TCP protocol
  • ‧Max. baudrate: 100M bps
  • ‧Modbus TCP connections
    • Client: 32
    • Server: 16
  • Smart data exchange
  • RTU mapping
  • Simple firewall
  • E-mail alarm

Specifications :
  • Transmission method: IEEE 802.3, IEEE 802.3u
  • Transmission interface: RJ-45 MDI/MDIX, no jumper cable required
  • Baudrate: 10/100 Mbps, auto-detection
  • Network protocols: ICMP, IP, TCP, UDP, DHCP, SMTP, NTP, Modbus TCP
  • Power supply voltage: 24 VDC (-15 to 20%)
  • Power consumption: 1.5 W
  • Insulation voltage: 500 V

Delta DVPDT02-H2


Delta DVPDT02-H2

DeviceNet Communication Devices
  • Supports connections with products of other brands
  • Wire-saving network topology
  • Offers 500k bps fieldbus data transmission of high stability and high interference resistance
  • Applicable in intricate industrial sites
Features & Benefits :
  • Supports DeviceNet protocol
  • For DVP-EH2 series PLC only
  • Max. baudrate: 500k bps
Specifications :
  • Transmission method: CAN
  • Connector: Removable, 5.08mm
  • Message type: Explicit, I/O polled
  • Serial baudrate: 125k, 250k, 500k bps
  • Network voltage: 24 VDC (11 to 25VDC)
  • Electrical isolation: 500 VDC

Delta DVPDT01-S


Delta DVPDT01-S

DeviceNet Communication Devices
  • Supports connections with products of other brands
  • Wire-saving network topology
  • Offers 500k bps fieldbus data transmission of high stability and high interference resistance
  • Applicable in intricate industrial sites
Features & Benefits :
  • Supports DeviceNet protocol
  • For DVP-S series PLC only
  • Max. baudrate: 500k bps
Specifications :
  • Transmission method: CAN
  • Connector: Removable, 5.08mm
  • Message type: Explicit, I/O polled
  • Serial baudrate: 125k, 250k, 500k bps
  • Network voltage: 24 VDC (11 to 25 VDC)
  • Electrical isolation: 500 VDC

Delta DVPDNET-SL

Delta DVPDNET-SL

DeviceNet Communication Devices
  • Supports connections with products of other brands
  • Wire-saving network topology
  • Offers 500k bps fieldbus data transmission of high stability and high interference resistance
  • Applicable in intricate industrial sites
Features & Benefits :
  • For DVP-EH3-L, DVP-MC, DVP-SA2, SE, SV2, SX2 Series PLC only
  • Supports DeviceNet protocol
  • Connectable to 64 slaves
  • Max. baudrate: 500k bps
  • Max. network length: 500m
  • RTU mapping
Specifications :
  • Transmission method: CAN
  • Connector: Removable, 5.08mm
  • Message type: Explicit, I/O polled, bit-strobed, COS/CC
  • Serial baudrate: 125k, 250k, 500k bps
  • Network voltage: 24 VDC (11 to 25 VDC), supplied by power cable on the network
  • Power consumption: 1.7 W
  • Electrical isolation: 500 VDC

Delta DVPCP02-H2


Delta DVPCP02-H2

CANopen Communication Devices
  • Flexible configuration
  • Supports CANopen DS301 and DSP402 protocols
  • Conducts multi-axis, high-speed and intricate motion control by max. baudrate 1M bps
Features & Benefits :
  • For DVP-EH2 series PLC only
  • Supports CANopen protocol
  • Max. baudrate: 1M bps
Specifications :
  • Transmission method: CAN
  • Connector: Removable, 5.08mm
  • Serial baudrate: 10k, 20k, 50k, 125k, 250k, 500k, 800k, 1M bps
  • Message type: PDO, SDO, SYNC, Emergency, NMT
  • Power supply voltage: 24 VDC (-15 to 20%)
  • Power consumption: 1.7 W
  • Electrical isolation: 500 VDC